MS Sedco MICRO, WALK Users Manual

MicroStar blue Motion and Presence Sensor Installation Instructions
FCC Compliance
This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Warning Statement
Product Description
The microStar blue is the combination motion and presence sensor that provides superior activation and safety for automatic sliding doors in a single device. The microStar blue uses patented microwave technology to create two seamless zones within its detection pattern. The activation zone provides selectable unidirectional or bidirectional motion detection. The safety zone provides contiguous presence detection at the threshold and through it when the door is open. The microStar blue’s proprietary software will learn the movement of the door and then ignore it when opening and closing thus allowing the safety zone to provide protection through the threshold area of the door. Two relay outputs are standard. Relay output #1 is for the activation (motion) zone and Relay output #2 is for the threshold safety (presence) zone.
Insert sensor component pictures here
Installation Preparation
Prior to installing this sensor verify you have the correct version microStar for the type of door it is being installed on. Match the color-coded microStar logo on the sensor cover to Chart A below.
(A) microStar Applications Chart
Sliding Folding Swinging Revolving Doors Doors Doors Doors microStar red X-safety microStar white X-approach X-approach microStar blue X-approach/safety microStar green X-approach/safety
Warning w/symbol: Remember to follow these safety precautions:
Shut off power to the automatic door before wiring sensor.
Always ensure wiring is located clear of any moving door parts to avoid
damage.
Always be aware of pedestrian traffic. Keep p eople clear of the work area when setting up or testing the door.
Comply with all applicable building codes and safety standards (ANSI A156.10).
Sensor Mounting:
1. Remove the cover of the microStar by placing the blade of a small screwdriver in the notch in the right side of the cover as shown (B). Once the sensor is attached to the header always remove the cover in this same manner.
(B) Cover Removal Diagram
2. Attach the mounting template as shown (C) flush with the bottom edge of the header. Drill 3 holes noted on template (1 wire passage hole, 2 screw pilot holes)
(C) Mounting Template Diagram
3. Insert mounting screws partially into holes. Route the wire harness along sensor backplate as shown (D). Feed the stripped end of the wire harness through the wire passage hole. Install the microStar onto the mounting screws and tighten.
(D) Wire Harness Diagram
Sensor Wiring:
With power OFF, connect sensor wiring to the operator control as shown (E). Two
wiring options are available. The activation relay output and safety relay output wires of the microStar can be connected to the activation input of the operator control (safety will be on at all times) OR the microStar’s activation relay output can be connected to the activation input of the operator control and the microStar’s safety relay output can connect to the safety input of the operator control (safety will be off when door is closed).
(E) Wiring Diagrams
Wiring to operator control’s activation input only:
Wiring to operator control’s activation and safety inputs:
Warning w/symbol: DO NOT APPLY POWER TO THE SENSOR!
Sensor Settings and Adjustments:
All settings and adjustments can be made via the microStar main circuit board so there is no need for costly or confusing proprietary set up devices.