2. Do not leave any objects which may move in the
detection pattern.
3. Do not mount where rain or snow will fall directly on
unit.
4. Do not mount in a place where reflection of sunlight
will shine on unit.
5. Do not mount in a humid or steamy environment.
6. Do not mount five devices in proximity to each other.
When using from 2 to 4 devices in proximity, use
alternate frequency settings as shown below.
(Maximum 4 sensors)
1
456
23
10Ft.
Use Alternate Frequency.
H/MH/ML/L
Connector
Mounting Holes
DIP Switches
A
Sensitivity
tterdt
Template
Mounting
Connection Cable
5 ft. (1.5m)
Instructions
ountin
Screws
Section 4
Mounting and Wiring
1. Using the mounting template provided, drill mounting
and wire holes.
8701 Castle Park Drive Indianapolis, Indiana 46256
Page 1
(82A042) DH97v0504
DH97
4-Row Active Infrared Presence Detector for Automatic Door Control INSTALLATION INSTRUCTIONS
Mounting and Wiring (continued)
5. Set desired sensor parameters as noted in Sections
5 & 7.
5. DIP Switch Settings
>
7. Adjusting Detection Pattern
>
6. Place cover on sensor and clean the sensor.
NOTE: For maximum pattern depth and width,
mount the DH97 at 10 feet and use the
!
maximum pattern angle (10º).
NOTE: The DH97 can be mounted using the
optional DH97-BDB or DH97-MP mounting
!
brackets when more flexible mounting is
required (See Page 5).
Section 5
Dip Switch Settings
ON
DEFAULT
SETTINGS
12345678
heavy snowfall or other extreme conditions.
8 Self-Monitoring: "ON"=When power is first
supplied to the DH97, the sensor automatically
performs a Self Diagnosis (See Section 9).
Section 6
Power
BEFORE APPLYING POWER, READ AND FOLLOW THESE
INSTRUCTIONS:
When power is applied, the sensor will read and store the
environmental optical parameters. This is necessary for
Presence Detection to work properly.
1. CLEAR THE AREA OF ANY UNNECESSARY OBJECTS.
2. Apply POWER.
3. Vacate the Detection Pattern immediately. While the
sensor sees ANY moving objects in its DETECTION
PATTERN, it will not proceed to the following step.
4. DO NOT enter DETECTION PATTERN for 10 seconds
(Presence Detection Setting).
5. TEST the presence feature, especially near the door.
When carrying out the following work, TURN OFF THE
POWER:
1. When the floor conditions change.
2. Adjusting pattern or sensitivity.
Presence
Timer
2 Sec
15 Sec
60 Sec
180 Sec
12
Pattern Depth
4 R
3 R
2 R
1 R
34
(Rows)
R
1R2R3R4
Freq uency
H
MH
ML
L
56
Monitor
mode
Snow
7
Normal
Self
Monitoring
ON
8
OFF
1&2 Presence Timer: Timer is adjustable using switches 1 and 2. 1 to 4 Rows will detect a
stationary object for the time period set by the
Presence Timer. The timer will reset and begin if
any movement is detected.
3&4 Pattern Depth (Rows): To adjust the pattern depth, set switches 3 & 4 as shown.
5&6 Frequency: When more than two sensors are used in close proximity to each other, to prevent
interference use alternate frequency settings.
(H + MH + ML + L = Maximum 4 sensors).
7 Monitor Mode: A Snow Mode is available. Snow
Mode should only be used in environments with
8701 Castle Park Drive Indianapolis, Indiana 46256
Adjust the detection pattern according to the following
diagrams:
1. Pattern Angle Adjustment.
SIDE VIEW/DETECTION PATTERN
Maximum Angle
( 10 º )
Max AreaMin Area
11.5' 9.8' 8.2' 6.6' 4.9' 3.3' 1.6' 0'
3.5m 3.0m 2.5m 2.0m 1.5m 1.0m 0.5m 0
Presence
8.2' 6.6' 4.9' 3.3' 1.6' 0'
2.5m 2.0m 1.5m 1.0m 0.5m 0m
0
1.6'
0.5m
3.3'
1.0m
4.9'
1.5m
6.6'
2.0m
8.2'
2.5m
9.9'
3.0m
1R2R3R4R
• The body of the sensor can be rotated from 0º to
10º (5 steps).
Minimum Angle
( 0º )
10
°
3R
2R 1R
4R
Presence
(82A042) DH97v0504
Page 2
DH97
4-Row Active Infrared Presence Detector for Automatic Door Control INSTALLATION INSTRUCTIONS
2. Pattern Width Adjustment.
Pattern Adjustments for single and/or double doors by
Side Lever.
FRONTAL VIEW/DETECTION PATTERN
15432
L
4R4
L
8.2' 6.6' 4.9' 3.3' 1.6' 1.6' 3.3' 4.9' 6.6' 8.2'
2.5 2.0 1.5 1.0 0.5 0.5 1.0 1.5 2.0 2. 5
WIDE
Side lever Adjustment
Do not use Position 5
1.6'
0.5m
3.3'
1.0m
4.9'
1.5m
6.6'
2.0m
8.2'
2.5m
9.9'
3.0m
0
15432
R
1
1
L
11.2
NARROW
5
°
8.2' 6.6' 4.9' 3.3' 1.6' 1.6' 3.3' 4.9' 6.6' 8.2'
2.5 2.0 1.5 1.0 0.5 0.5 1.0 1.5 2.0 2. 5
R
°
5
.2
11
Detection pattern will vary according to
!
objects, material, color and speed.
Section 8
Verification of Operation
1. After mounting, setting parameters and applying
power, walk test unit to verify detection pattern.
2. If the door does not operate properly, recheck the dip
switch settings and pattern adjustments.
3. After rechecking, if there is still a problem, adjust the
sensitivity.
• Adjust high (clockwise) to increase sensitivity.
• Adjust low (counter-clockwise) to decrease
sensitivity.
APPLY ONLY SMALL TORQUE
!
Sensitivity
the Indicator LED will switch continuously between RED
and GREEN. The door will remain in an Open position
throughout.
ON
OFF
Relay Output Timing Chart
(When no reflection)
12 sec
60 sec
1 cycle
12 sec
*****EXTREMELY IMPORTANT*****
After final set-up, test unit(s) completely to ensure that
proper coverage has been achieved (width, depth and
location of the pattern must be tested).
After the installation and operational check of the
system:
1. Place the proper labels on the door per ANSI/BHMA
A156.10 & BS 7036.
2. Instruct the owner of the door system operation and
how to test it. This should be checked on a daily
basis.
3. Instruct the owner on what to do if the door or any of
its components become damaged.
4. Strongly recommend to the owner that the complete
entry be inspected twice a year as part of the service
agreement.
Section 10
Troubleshooting
PROBLEM 1: Door does not open
CAUSE 1: Sensor Connector
SOLUTION 1: Tighten connector or reconnect
CAUSE 2: Power Supply
SOLUTION 2: Check that the power supply is properly
connected and 12V to 24V AC or DC
PROBLEM 2: Door operates intermittently
CAUSE 1: Sensor is very dusty or covered in water
drops, etc.
SOLUTION 1: Clean the sensor (do not use thinner or
alcohol to clean sensor)
Section 9
Self Monitoring
Infrared beams are received on the receiver side of the
DH97, then the following occurs. For 12 seconds, the
relay starts chattering ON/OFF (4 times in 12 seconds).
Then the relay remains in the ON condition for 60
seconds. The cycle then repeats itself. At the same time,
CAUSE 2: Sensitivity too low
SOLUTION 2: Turn up sensitivity
CAUSE 3: Detection pattern in the wrong position
SOLUTION 3: Alter the detection pattern by changing
sensor angle, dip switch settings and/or
pattern width adjustments
8701 Castle Park Drive Indianapolis, Indiana 46256
Page 3
(82A042) DH97v0504
s
DH97
4-Row Active Infrared Presence Detector for Automatic Door Control INSTALLATION INSTRUCTIONS
PROBLEM 3: Door operates by itself
CAUSE 1: Sensitivity too high
SOLUTION 1: Turn down sensitivity
CAUSE 2: Another sensor is too close by
SOLUTION 2: Change the frequency to each sensor
CAUSE 3: Sensor detects the door movement
SOLUTION 3: If the indicator LED is an Orange color,
adjust the pattern depth angle away
from the door
CAUSE 4: There is a cloth mat in the detection
pattern
SOLUTION 4: Turn the sensor power off and then on
again, and allow it 10 seconds to
reprogram
CAUSE 5: Detection pattern too far in front of the
door, detecting people passing by
SOLUTION 5: Adjust the detection pattern - move it
closer to the door
CAUSE 6: The condition of the monitored area is
varying (i.e., dusty, dirty, snow)
SOLUTION 6: The condition of the detection zone can
change due to heavy dust or dirty, heavy
snow or footprints being left in fresh
snow. This will cause the door to open
sometimes. Set the Presence Timer to a
short time. (See Section 5)
Presence Timer................. Limits of 2, 15, 60 and 180
MS SEDCO guarantees this product to be free from manufacturing
defects for 3 years from date of installation. Unless MS SEDCO is
notified of the date of installation, the warranty will be in effect for
3 years from the date of shipment from our factory. If, during the
first 3 years, our motion detector or support device fails to operate
and has not been tampered with our abused, the unit can be
returned prepaid to factory and it will be repaired free of charge.
After 3 years, the unit will be repaired for a nominal service
charge. This limited warranty is in lieu of all other warranties
expressed or implied, including any implied warranty of
merchantability, and no representative or person is authorized
to assume for MS SEDCO any other liability in connection with
the sale of our products. All warranties are limited to the
duration of this written warranty. In no event shall MS SEDCO
be liable for any special, incidental, consequential or other
damages arising from any claimed breach of warranty as to its
products or services.
Page 4
(82A042) DH97v0504
DH97
4-Row Active Infrared Presence Detector for Automatic Door Control INSTALLATION INSTRUCTIONS
Section 14
DH97-BDB Backplate/Bracket and DH97-MP
Mounting Plate
The DH97-BDB is an optional bracket for the DH97
sensor. It allows universal aim adjustment and adapts
the DH97 for unique mounting requirements.
DH97-BDB
The DH97-MP is an optional mounting plate that adapts
the DH97 sensor for mounting to a 1 3/4" door header. It
can also be field prepped for a variety of unique mounting
applications.