MSI MS-v067 Schematic 10

MS-V067 VER 10
REV HISTORY
P501-A01 DESIGN -- G73, 256 MB DDR2, VGA, DVI-I, HDTV
PAGE SUMMARY:
Page 1: TABLE OF C ON TEN TS & REVISION HISTORY Page 2: PCI EXPRESS 16X, NVVDD DECOUPLING CAPS,PEX_IOVDD/Q DECOUPLING CAPS Page 3: FBA MEMORY INTERFACE, GPU FBVDD/Q DECOUPLING CAPS, FBVTT TERMINATION Page 4: FBA 16Mx16 DDR2 MEMORIES, BANK 0..31 Page 5: FBA 16Mx16 DDR2 MEMORIES, 1ST BANK 32..63 Page 6: FBC MEMORY INTERFACE, GPU FBVTT, FBVDDQ Page 7: FBC 16MX16 DDR2 MEMORIES, 2ND BANK 0..31 Page 8: FBC 16Mx1 6 DDR2 MEMORIES, 2ND BANK 32..63 Page 9: DACA FILTERS, DACA SYNC BUFFERS & DB15 SOUTH Page 10: DACC FILTERS, DACC SYNC BUFFERS & DB15 MID Page 11: TMDS LINK A & PU's, DVI CONNECTOR SOUTH Page 12: TMDS LINK C Page 13: MIO A & MIO B
Page 14: DACB FILTERS, SYNC STRIPPER, MINIDIN CONNECTOR NORTH,HDTV HEADER Page 15: GPU GND CONNECTION, XTAL Page 16: JTA G , BIOS ROM, HDCP ROM, FAN CONTROL, GPIO Page 17: BIOS S TRAPS & MECHANICALS Page 18: POWER SUPPLY: TMDS IOVDD,5V,A3V3 Page 19: PowerS upplyI: NVVDD, A2V5 Page 20: PowerSupplyIII: FBVDDQ, PL L VD D
Base on P501_A01 modify
- 4/13/2006:
1.PAGE:12 INTERNAL TMDS LINK C/D Add DVI circuit
2.PAGE:19/20 :Power modify 6549 circuit pin to pin RT9259/9259A
3.PAGE:11/12 :TMDS Link Add EMI solution
- 4/14/2006:
1.PAGE:12 INTERNAL TMDS LINK C/D Add DVI dual link circuit
2.PAGE:19/20 :Power modify 6549 circuit reserve C840/C841 High side gate to phase
- 4/17/2006:
1.PAGE:19/20 :Power modify 6549 circuit Change 6549 Footprint SSOP16 to SOP14
2.Change IC,L footprint to MSI Data Base
- 4/20/2006:
1.PAGE:18 : Add FM1~FM6 for ME Add C884~C850 for EMC suggestion reserve
2.PAGE:19 :Remove D9/R18 SC2621A Only
- 5/24/2006:
1.PAGE:12 : Revise TMDS A2V5 power for Link C/D
2.PAGE:20 : Add R640/R641 NVVDD conect to PEX1V2 Change C13 SMD to DIP footprint
3.PAGE:12/13 : Remove DVI EMI commom choke
VARIANT ASSEMBLY
SKU
B
0000
1
0001
2
<UNDEFINED>
3
<UNDEFINED>
4
<UNDEFINED>
5
<UNDEFINED>
6
<UNDEFINED>
7
<UNDEFINED>
8
<UNDEFINED>
9
<UNDEFINED>
10
<UNDEFINED>
11
<UNDEFINED>
12
<UNDEFINED>
13
<UNDEFINED>
14
<UNDEFINED>
15
<UNDEFINED> <UNDEFINED>
NVPN
600-10501-0000-100 600-10501-0001-100 <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED>
www.vinafix.vn
G73 400/350MHz 256MB 128bit DDR2 16MX16 DVI-I+VGA+HDTVOUT G73-V 375/350MHZ 256MB 128bit <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED> <UNDEFINED>
DDR2 16MX16 DVI-I+VGA+HDTVOUT
Micro-Star International Co., LTD.
MS-V067
Size Document Number Rev Custom
Date:
P501 Overview
Tuesday, June 06, 2006
Sheet of
120
0A
16X PCIe Interface
3V3_PEX
3V3AUX
C41 .01UF
25V 10% X7R 0402 COMMON
GND
C47 .1UF
25V 10% X7R 0603 COMMON
Place Close to fingers
C40 .1UF
16V 10% X7R 0402 COMMON
GND
12V_PEX
3V3_PEX
3V3AUX
SNN_PE_PRSNT2_A
SNN_PE_RSVD2
SNN_PE_PRSNT2_B SNN_PE_RSVD3 SNN_PE_RSVD4 SNN_PE_RSVD5
SNN_PE_PRSNT2_C SNN_PE_RSVD6
PRSNT SNN_PE_RSVD7 SNN_PE_RSVD8
C773 10UF
16V 20% X5R 1206 COMMON
GND
12V_PEX
C779
C780
.01UF
25V 10% X7R 0402
END OF X1
END OF X4
END OF X8
COMMON
TRST* JTAG1
TCLK JTAG2
TDI JTAG3 TDO JTAG4 TMS JTAG5
SMCLK SMDAT
PERST
REFCLK REFCLK
PERP0 PERN0
PETP0 PETN0
PERP1 PERN1
PETP1 PETN1
PERP2 PERN2
PETP2 PETN2
PERP3 PERN3
PETP3 PETN3
PERP4 PERN4
PETP4 PETN4
PERP5 PERN5
PETP5 PETN5
PERP6 PERN6
PETP6 PETN6
PERP7 PERN7
PETP7 PETN7
PERP8 PERN8
PETP8 PETN8
PERP9 PERN9
PETP9 PETN9
PERP10 PERN10
PETP10 PETN10
PERP11 PERN11
PETP11 PETN11
PERP12 PERN12
PETP12 PETN12
PERP13 PERN13
PETP13 PETN13
PERP14 PERN14
PETP14 PETN14
PERP15 PERN15
PETP15 PETN15
B9 A5 A6 A7 A8
B5 B6
B11
WAKE
A11
A13 A14
A16 A17
B14 B15
A21 A22
B19 B20
A25 A26
B23 B24
A29 A30
B27 B28
A35 A36
B33 B34
A39 A40
B37 B38
A43 A44
B41 B42
A47 A48
B45 B46
A52 A53
B50 B51
A56 A57
B54 B55
A60 A61
B58 B59
A64 A65
B62 B63
A68 A69
B66 B67
A72 A73
B70 B71
A76 A77
B74 B75
A80 A81
B78 B79
CN1
CON_FINGER_PEX_164
CON_X16
COMMON
B1
+12V
B2
+12V
A2
+12V
A3
+12V
B3
+12V/RSVD
B8
+3V3
A9
+3V3
A10
+3V3
B10
+3V3AUX
A1
PRSNT1
B17
PRSNT2
B12
RSVD
B4
GND
A4
GND
B7
GND
A12
GND
B13
GND
A15
GND
B16
GND
B18
GND
A18
GND
GND
B31
PRSNT2
A19
RSVD
B30
RSVD
A32
RSVD
A20
GND
B21
GND
B22
GND
A23
GND
A24
GND
B25
GND
B26
GND
A27
GND
A28
GND
B29
GND
A31
GND
B32
GND
GND
B48
PRSNT2
A33
RSVD
A34
GND
B35
GND
B36
GND
A37
GND
A38
GND
B39
GND
B40
GND
A41
GND
A42
GND
B43
GND
B44
GND
A45
GND
A46
GND
B47
GND
B49
GND
A49
GND
GND
B81
PRSNT2
A50
RSVD
B82
RSVD
A51
GND
B52
GND
B53
GND
A54
GND
A55
GND
B56
GND
B57
GND
A58
GND
A59
GND
B60
GND
B61
GND
A62
GND
A63
GND
B64
GND
B65
GND
A66
GND
A67
GND
B68
GND
B69
GND
A70
GND
A71
GND
B72
GND
B73
GND
A74
GND
A75
GND
B76
GND
B77
GND
A78
GND
A79
GND
B80
GND
A82
GND
END OF X16
C791
.1UF
10UF
16V
25V 10%
20%
X7R
X5R 1206
0603 COMMON
COMMON
GND
SNN_JT_TRST*
SNN_JT_TCLK
SNN_JT_TMS
SNN_PEX_SMCLK SNN_PEX_SMDAT
SNN_PEX_WAKE*
PEXJT_TDIO
MAKE THIS TRACE CUTTABLE
SNN_PEXCAPD_VDDQ SNN_PEXCALPD_GND
R512
200
COMMON
C690
C666
C667
C647
C650
C630
C628
C609
C592
C584
C581
PEX_TEST_PLLCLK_OUT PEX_TEST_PLLCLK_OUT_N
.1UF
10% X7R
.1UF
10% X7R
.1UF
10% X7R
.1UF
10% X7R
.1UF
.1UF
10% X7R
.1UF
16V 10% X7R
.1UF
.1UF
10% X7R
.1UF
10% X7R
.1UF
10% X7R
.1UF
16V 10% X7R
.1UF
10% X7R
.1UF
10% X7R
.1UF
.1UF
10% X7R
0402
5%
PEX_TX0 PEX_TX0*
COMMON0402 16V
PEX_TX1 PEX_TX1*
COMMON0402 16V
PEX_TX2 PEX_TX2*
COMMON0402 16V
PEX_TX3 PEX_TX3*
COMMON0402 16V
PEX_TX4 PEX_TX4*
COMMON0402 16V 10% X7R
PEX_TX5 PEX_TX5*
COMMON0402 16V
PEX_TX6 PEX_TX6*
COMMON0402
PEX_TX7 PEX_TX7*
COMMONX7R16V 10%04 02
PEX_TX8 PEX_TX8*
COMMON0402 16V
PEX_TX9 PEX_TX9*
COMMON0402 16V
PEX_TX10 PEX_TX10*
COMMON0402 16V
PEX_TX11 PEX_TX11*
COMMON0402
PEX_TX12 PEX_TX12*
COMMON0402 16V
PEX_TX13 PEX_TX13*
COMMON0402 16V
PEX_TX14 PEX_TX14*
COMMON0402 16V 10% X7R
PEX_TX15 PEX_TX15*
COMMON0402 16V
PEX_RST*
PEX_REFCLK
PEX_REFCLK*
PEX_TXX0 PEX_TXX0
PEX_TXX0* PEX_TXX0*
PEX_RX0
PEX_RX0*
PEX_TXX1
PEX_TXX1*
PEX_RX1
PEX_RX1*
PEX_TXX2
PEX_TXX2*
PEX_RX2
PEX_RX2*
PEX_TXX3
PEX_TXX3*
PEX_RX3
PEX_RX3*
PEX_TXX4
PEX_TXX4*
PEX_RX4
PEX_RX4*
PEX_TXX5
PEX_TXX5*
PEX_RX5
PEX_RX5*
PEX_TXX6
PEX_TXX6*
PEX_RX6
PEX_RX6*
PEX_TXX7
PEX_TXX7*
PEX_RX7
PEX_RX7*
PEX_TXX8
PEX_TXX8*
PEX_RX8 PEX_RX8
PEX_RX8* PEX_RX8*
PEX_TXX9
PEX_TXX9*
PEX_RX9
PEX_RX9*
PEX_TXX10
PEX_TXX10*
PEX_RX10
PEX_RX10*
PEX_TXX11
PEX_TXX11*
PEX_RX11
PEX_RX11*
PEX_TXX12
PEX_TXX12*
PEX_RX12
PEX_RX12*
PEX_TXX13
PEX_TXX13*
PEX_RX13
PEX_RX13*
PEX_TXX14
PEX_TXX14*
PEX_RX14
PEX_RX14*
PEX_TXX15
PEX_TXX15*
PEX_RX15
PEX_RX15*
C696
COMMON X7R 10% 0402 16V
C669
COMMON X7R 10% 0402 16V
C675
COMMON X7R 10% 0402
C655
COMMON X7R 10% 0402 16V
C656
COMMON X7R 10% 0402 16V
C638
COMMON X7R 10% 0402 16V
C634
COMMON X7R 10% 0402 16V
C620
COMMON 10%X7R 0402 16V
C612
COMMON X7R 10% 0402 16V
C602
COMMON X7R 10% 0402 16V
C590
COMMON X7R 10% 0402 16V
C586
COMMON X7R 10 % 0402 16V
C583
COMMON X7R 10% 0402 16V
C582
COMMON X7R 10% 0402 16V
C571
COMMON X7R 10% 0402 16V
C572
COMMON X7R 10% 0402 16V
.1UF
.1UF
.1UF
16V
.1UF
.1UF
.1UF
.1UF
.1UF
C604
.1UF
.1UF
.1UF
C585
.1UF
.1UF
.1UF
C580
.1UF
C568
C570
.1UF
AH15
AG12 AH13
AM12 AM11
AH14
AJ14 AJ15
AK15 AK13
AK14 AH16
AG16 AM14
AM15 AG17
AH17
AL15 AL16
AG18 AH18
AK16 AK17
AK18
AJ18 AL17
AL18 AJ19
AH19 AM18
AM19 AG20
AH20 AK19
AK20 AG21
AH21
AL20 AL21
AK21
AJ21
AM21 AM22
AJ22
AH22 AK22
AK23 AG23
AH23
AL23 AL24
AK24
AJ24
AM24 AM25
AJ25
AH25 AK25
AK26 AH26
AG26
AL26 AL27
AK27
AJ27
AM27 AM28
AJ28 AH27
AL28 AL29
G1A
BGA_0820_P100_330X330_G3_128B COMMON
1/14 PCI_EXPRESS
PEX_RST
RFU RFU
PEX_TSTCLK_OUT PEX_TSTCLK_OUT
PEX_REFCLK PEX_REFCLK
PEX_TX0 PEX_TX0
PEX_RX0 PEX_RX0
PEX_TX1 PEX_TX1
PEX_RX1 PEX_RX1
PEX_TX2 PEX_TX2
PEX_RX2 PEX_RX2
PEX_TX3 PEX_TX3
PEX_RX3 PEX_RX3
PEX_TX4 PEX_TX4
PEX_RX4 PEX_RX4
PEX_TX5 PEX_TX5
PEX_RX5 PEX_RX5
PEX_TX6 PEX_TX6
PEX_RX6 PEX_RX6
PEX_TX7 PEX_TX7
PEX_RX7 PEX_RX7
PEX_TX8 PEX_TX8
PEX_RX8 PEX_RX8
PEX_TX9 PEX_TX9
PEX_RX9 PEX_RX9
PEX_TX10 PEX_TX10
PEX_RX10 PEX_RX10
PEX_TX11 PEX_TX11
PEX_RX11 PEX_RX11
PEX_TX12 PEX_TX12
PEX_RX12 PEX_RX12
PEX_TX13 PEX_TX13
PEX_RX13 PEX_RX13
PEX_TX14 PEX_TX14
PEX_RX14 PEX_RX14
PEX_TX15 PEX_TX15
PEX_RX15 PEX_RX15
OTHER NV43/NV44
NV_PLLAVD D VDD
OTHER NV43/NV44
PEX_IOVDD PEX_IOVDD PEX_IOVDD PEX_IOVDD PEX_IOVDD PEX_IOVDD
PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ
VDD_SENSE GND_SENSE
PEX_PLLAVDD PEX_PLLDVDD
PEX_PLLGND
SPDIF NC
VDD_LP VDD_LP VDD_LP VDD_LP VDD_LP VDD_LP
VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33
600mA
AD23 AF23 AF24 AF25 AG24 AG25
AC16 AC17 AC21 AC22 AE18 AE21 AE22 AF12 AF18 AF21 AF22
K16
VDD
K17
VDD
N13
VDD
N14
VDD
N16
VDD
N17
VDD
N19
VDD
P13
VDD
P14
VDD
P16
VDD
P17
VDD
P19
VDD
R16
VDD
R17
VDD
T14
VDD
T15
VDD
T18
VDD
T19
VDD
U13
VDD
U14
VDD
U15
VDD
U18
VDD
U19
VDD
V16
VDD
V17
VDD
W13
VDD
W14
VDD
W16
VDD
W17
VDD
W19
VDD
Y13
VDD
Y14
VDD
Y16
VDD
Y17
VDD
Y19
VDD
Y20
VDD
P20 T20 T23 U20 U23 W20
NVVDD_SENSE
N20
SNN_GND_SENSE
M21
AC11 AC12 AC24 AD24 AE11 AE12 H7 J7 K7 L10 L7 L8 M10
AF15 AE15 AE16
GND
NV_PLLAVDD
T13
C676 1UF
16V 10% X5R 0603 COMMON
SNN_GPU_AM10_NC
AM8
NC
SNN_GPU_AM8_NC
AM9
NC
SNN_GPU_AM9_NC
B32
NC
J6
240R@100MHz
GND
SPDIF
C657 .022UF
16V 10% X7R 0402 COMMON
C649 .022UF
16V 10% X7R 0402 COMMON
VDD33
PEX_PLL_VDD
COMMONIND_SMD_0402
C684 .1UF
16V 10% X7R 0402 COMMON
VALUES TBD
Place near balls
C693 .47UF
6.3V 10% X5R 0402 COMMON
C639 .1UF
16V 10% X7R 0402 COMMON
C688 .47UF
6.3V 10% X5R 0402 COMMON
C626 .47UF
6.3V 10% X5R 0402 COMMON
VALUES TBD
PEX1V2
LB503
16,16
IN
C643 .022UF
16V 10% X7R 0402 COMMON
C611 .022UF
16V 10% X7R 0402 COMMON
C660 .1UF
16V 10% X7R 0402 COMMON
C668 .1UF
16V 10% X7R 0402 COMMON
C644 .1UF
16V 10% X7R 0402 COMMON
C674 .1UF
16V 10% X7R 0402 COMMON
180mA
Place near balls
C591 .022UF
16V 10% X7R 0402 COMMON
VALUES TBD
Place near balls
C623 .01UF
25V 10% X7R 0402 COMMON
Place near balls
Place near balls
C718 .1UF
16V 10% X7R 0402 COMMON
C694 .1UF
16V 10% X7R 0402 COMMON
Place near balls
C680 .1UF
16V 10% X7R 0402 COMMON
20mA
C678 .47UF
6.3V 10% X5R 0402 COMMON
C648 .47UF
6.3V 10% X5R 0402 COMMON
C673 .1UF
16V 10% X7R 0402 COMMON
C679 .1UF
16V 10% X7R 0402 COMMON
C689 4700PF
25V 10% X7R 0402 COMMON
C697 4700PF
25V 10% X7R 0402 COMMON
C665 4700PF
25V 10% X7R 0402 COMMON
Place Close to GPU
C632 .01UF
25V 10% X7R 0402 COMMON
IN
C664 .01UF
25V 10% X7R 0402 COMMON
C635 .1UF
16V 10% X7R 0402 COMMON
C616 .47UF
6.3V 10% X5R 0402 COMMON
C645 .47UF
6.3V 10% X5R 0402 COMMON
19,19
C646 .47UF
6.3V 10% X5R 0402 COMMON
C670 470PF
50V 10% X7R 0402 COMMON
C703 .022UF
16V 10% X7R 0402 COMMON
C728 .022UF
16V 10% X7R 0402 COMMON
C598 1UF
6.3V 10% X7R 0603 COMMON
C681 .01UF
25V 10% X7R 0402 COMMON
C627 1UF
6.3V 10% X7R 0603 COMMON
C653 .47UF
6.3V 10% X5R 0402 COMMON
C625 .1UF
16V 10% X7R 0402 COMMON
C654 .47UF
6.3V 10% X5R 0402 COMMON
C692 .1UF
16V 10% X7R 0402 COMMON
C599 .022UF
16V 10% X7R 0402 COMMON
C709 .022UF
16V 10% X7R 0402 COMMON
Place Near BGA
C663 1UF
6.3V 10% X7R 0603 COMMON
Place Near BGA
C595
4.7UF
6.3V X5R 0603 COMMON
Place Close to GPU
C698 1UF
6.3V 10% X7R 0603 COMMON
C686 1UF
6.3V 10% X7R 0603 COMMON
C629 1UF
6.3V 10% X7R 0603 COMMON
C677 .47UF
6.3V 10% X5R 0402 COMMON
A3V3
GND
GND
180R@100MHz
LB502
PEX1V2
10%
GND
LB505 180R@100MHz
COMMON IND_SMD_0603
C613 1UF
6.3V 10% X7R 0603 COMMON
COMMONIND_SMD_0603
GND
BI BI BI BI
BI BI BI BI BI BI
GND
PEX1V2
C52
4.7UF
6.3V 10% X5R 0805 COMMON
NVVDD
C661 10UF
6.3V 20% X5R 0805 COMMON
C662 1UF
6.3V 10% X7R 0603 COMMON
C691 .1UF
16V 10% X7R 0402 COMMON
GND
GND
300 mA
PEX1V2
GND
GND
GND
C640
4.7UF
6.3V X5R 0603 COMMON
BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI
BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI
BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI BI
BI
BI
12V_PEX 3V3_PEX
10%
3V3_PEX
12V_PEX
PEX_TX0 PEX_TX0* PEX_TX1 PEX_TX1* PEX_TX2 PEX_TX2* PEX_TX3 PEX_TX3* PEX_TX4 PEX_TX4* PEX_TX5 PEX_TX5* PEX_TX6 PEX_TX6* PEX_TX7 PEX_TX7* PEX_TX8 PEX_TX8* PEX_TX9 PEX_TX9* PEX_TX10 PEX_TX10* PEX_TX11 PEX_TX11* PEX_TX12 PEX_TX12* PEX_TX13 PEX_TX13* PEX_TX14 PEX_TX14* PEX_TX15 PEX_TX15*
PEX_TXX1 PEX_TXX1* PEX_TXX2 PEX_TXX2* PEX_TXX3 PEX_TXX3* PEX_TXX4 PEX_TXX4* PEX_TXX5 PEX_TXX5* PEX_TXX6 PEX_TXX6* PEX_TXX7 PEX_TXX7* PEX_TXX8 PEX_TXX8* PEX_TXX9 PEX_TXX9* PEX_TXX10 PEX_TXX10* PEX_TXX11 PEX_TXX11* PEX_TXX12 PEX_TXX12* PEX_TXX13 PEX_TXX13* PEX_TXX14 PEX_TXX14* PEX_TXX15 PEX_TXX15*
PEX_RX0 PEX_RX0* PEX_RX1 PEX_RX1* PEX_RX2 PEX_RX2* PEX_RX3 PEX_RX3* PEX_RX4 PEX_RX4* PEX_RX5 PEX_RX5* PEX_RX6 PEX_RX6* PEX_RX7 PEX_RX7*
PEX_RX9 PEX_RX9* PEX_RX10 PEX_RX10* PEX_RX11 PEX_RX11* PEX_RX12 PEX_RX12* PEX_RX13 PEX_RX13* PEX_RX14 PEX_RX14* PEX_RX15 PEX_RX15*
NET
NET
PEX_REFCLK
PEX_REFCLK*
GPU_PEX_REFCLK
GPU_PEX_REFCLK*
PEX_PLL_VDD
NV_PLLAVDD
NV_SOURCE_POWER
NV_CRITICALNET
1
1 100DIFF
1 PEX_TXX1100DIFF
1 1
1
1
1
1
1
1
1
1 1
1
1
VOLTAGE
1.20000
NV_IMPEDENCE
100DIFF1 100DIFF1 100DIFF1
100DIFF1
100DIFF1
100DIFF1 100DIFF1 100DIFF1 100DIFF
100DIFF1
100DIFF1 100DIFF1 100DIFF1 100DIFF1 100DIFF1
100DIFF1
100DIFF
100DIFF1
100DIFF
100DIFF PEX_RX4
100DIFF
100DIFF 100DIFF
100DIFF
100DIFF
MIN_LINE_WIDTH
10.01.20000
10.0
MAX_CURRENTVOLTAGE
Micro-Star International Co., LTD.
MS-V067
Size Document Number Rev Custom
16X PCIe Interface
Date:
Tuesday, June 06, 2006
DIFFPAIR
PEX_REFCLK100DIFF1
PEX_REFCLK100DIFF1 GPU_PEX_REFCLK1 100DIFF GPU_PEX_REFCLK100DIFF1
PEX_TX0100DIFF1
PEX_TX0
PEX_TX1
PEX_TX1
PEX_TX2100DIFF1
PEX_TX2100DIFF1
PEX_TX31 100DIFF
PEX_TX3100DIFF1
PEX_TX4100DIFF1
PEX_TX4
PEX_TX5100DIFF1
PEX_TX5
PEX_TX6100DIFF1
PEX_TX6
PEX_TX7
PEX_TX7
PEX_TX8100DIFF1
PEX_TX8
PEX_TX9
PEX_TX9100DIFF1
PEX_TX10
PEX_TX10
PEX_TX11
PEX_TX11
PEX_TX12
PEX_TX12100DIFF1
PEX_TX13
PEX_TX131 100DIFF
PEX_TX14
PEX_TX14100DIFF1
PEX_TX15100DIFF1
PEX_TX15100DIFF1
PEX_TXX0100DIFF1
PEX_TXX0100DIFF1
PEX_TXX11 100DIFF
PEX_TXX2100DIFF1
PEX_TXX2100DIFF1 PEX_TXX3100DIFF1 PEX_TXX3100DIFF1 PEX_TXX4100DIFF1 PEX_TXX4100DIFF1 PEX_TXX5100DIFF1
PEX_TXX5100DIFF1 PEX_TXX6100DIFF1 PEX_TXX61 100DIFF
PEX_TXX7100DIFF1
PEX_TXX7100DIFF1
PEX_TXX8100DIFF1
PEX_TXX8100DIFF1
PEX_TXX9100DIFF1
PEX_TXX9100DIFF1
PEX_TXX10100DIFF1
PEX_TXX10100DIFF1
PEX_TXX11100DIFF1
PEX_TXX11100DIFF1
PEX_TXX12100DIFF1
PEX_TXX12100DIFF1
PEX_TXX131 100DIFF
PEX_TXX13100DIFF1
PEX_TXX14100DIFF1
PEX_TXX14100DIFF1
PEX_TXX15100DIFF1
PEX_TXX15100DIFF1
PEX_RX0
PEX_RX0100DIFF1
PEX_RX1100DIFF
PEX_RX1100DIFF1
PEX_RX2100DIFF
PEX_RX2100DIFF1
PEX_RX3100DIFF1
PEX_RX3100DIFF
PEX_RX4
PEX_RX5
PEX_RX5100DIFF1
PEX_RX6
PEX_RX6100DIFF
PEX_RX7100DIFF1
PEX_RX7100DIFF1
PEX_RX8100DIFF1
PEX_RX8100DIFF1
PEX_RX9100DIFF1
PEX_RX9100DIFF
PEX_RX10
PEX_RX10
PEX_RX11100DIFF1
PEX_RX11100DIFF1
PEX_RX12100DIFF1
PEX_RX12100DIFF1
PEX_RX13
PEX_RX13100DIFF1
PEX_RX14100DIFF1
PEX_RX14
PEX_RX15100DIFF1
PEX_RX15100DIFF1
MIN_WIDTH
Sheet of
35.05.512V12V
25.03.03.3V3.3V
220
0A
www.vinafix.vn
GPU: FB-Interface A
3,4,5
3,4,5
3,4,5
3,4,5
FBAD[63..0]
BI
FBAD0
0
FBAD1
1
FBAD2
2
FBAD3
3
FBAD4
4
FBAD5
5
FBAD6
6
FBAD7
7
FBAD8
8
FBAD9
9
FBAD10
10
FBAD11
11
FBAD12
12
FBAD13
13
FBAD14
14
FBAD15
15
FBAD16
16
FBAD17
17
FBAD18
18
FBAD19
19
FBAD20
20
FBAD21
21
FBAD22
22
FBAD23
23
FBAD24
24
FBAD25
25
FBAD26
26
FBAD27
27
FBAD28
28
FBAD29
29
FBAD30
30
FBAD31
31
FBAD32
32
FBAD33
33
FBAD34
34
FBAD35
35
FBAD36
36
FBAD37
37
FBAD38
38
FBAD39
39
FBAD40
40
FBAD41
41
FBAD42
42
FBAD43
43
FBAD44
44
FBAD45
45
FBAD46
46
FBAD47
47
FBAD48
48
FBAD49
49
FBAD50
50
FBAD51
51
FBAD52
52
FBAD53
53
FBAD54
54
FBAD55
55
FBAD56
56
FBAD57
57
FBAD58
58
FBAD59
59
FBAD60
60
FBAD61
61
FBAD62
62
FBAD63
63
FBADQM[7..0]
OUT
FBADQS[7..0]
BI
FBADQSN[7..0]
BI
FBADQM0
0
FBADQM1
1
FBADQM2
2
FBADQM3
3
FBADQM4
4
FBADQM5
5
FBADQM6
6
FBADQM7
7
FBADQS0
0
FBADQS1
1
FBADQS2
2
FBADQS3
3
FBADQS4
4
FBADQS5
5
FBADQS6
6
FBADQS7
7
FBADQSN0 FBADQSN0
0
FBADQSN1
1
FBADQSN2
2
FBADQSN3
3
FBADQSN4
4
FBADQSN5
5
FBADQSN6
6
FBADQSN7
7
SNN_FBA_VREF
G1B
BGA_0820_P100_330X330_G3_128B COMMON
N27
FBAD0
M27
FBAD1
N28
FBAD2
L29
FBAD3
K27
FBAD4
K28
FBAD5
J29
FBAD6
J28
FBAD7
P30
FBAD8
N31
FBAD9
N30
FBAD10
N32
FBAD11
L31
FBAD12
L30
FBAD13
J30
FBAD14
L32
FBAD15
H30
FBAD16
K30
FBAD17
H31
FBAD18
F30
FBAD19
H32
FBAD20
E31
FBAD21
D30
FBAD22
E30
FBAD23
H28
FBAD24
H29
FBAD25
E29
FBAD26
J27
FBAD27
F27
FBAD28
E27
FBAD29
E28
FBAD30
F28
FBAD31
AD29
FBAD32
AE29
FBAD33
AD28
FBAD34
AC28
FBAD35
AB29
FBAD36
AA30
FBAD37
Y28
FBAD38
AB30
FBAD39
AM30
FBAD40
AF30
FBAD41
AJ31
FBAD42
AJ30
FBAD43
AJ32
FBAD44
AK29
FBAD45
AM31
FBAD46
AL30
FBAD47
AE32
FBAD48
AE30
FBAD49
AE31
FBAD50
AD30
FBAD51
AC31
FBAD52
AC32
FBAD53
AB32
FBAD54
AB31
FBAD55
AG27
FBAD56
AF28
FBAD57
AH28
FBAD58
AG28
FBAD59
AG29
FBAD60
AD27
FBAD61
AF27
FBAD62
AE28
FBAD63
M29
FBADQM0
M30
FBADQM1
G30
FBADQM2
F29
FBADQM3
AA29
FBADQM4
AK30
FBADQM5
AC30
FBADQM6
AG30
FBADQM7
L28
FBADQS_WP0
K31
FBADQS_WP1
G32
FBADQS_WP2
G28
FBADQS_WP3
AB28
FBADQS_WP4
AL32
FBADQS_WP5
AF32
FBADQS_WP6
AH30
FBADQS_WP7
M28
FBADQS_RN0
K32
FBADQS_RN1
G31
FBADQS_RN2
G27
FBADQS_RN3
AA28
FBADQS_RN4
AL31
FBADQS_RN5
AF31
FBADQS_RN6
AH29
FBADQS_RN7
E32
FB_VREF1
2/14 FBA
FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD
FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ
FBA_CMD0 FBA_CMD1 FBA_CMD2 FBA_CMD3 FBA_CMD4 FBA_CMD5 FBA_CMD6 FBA_CMD7 FBA_CMD8
FBA_CMD9 FBA_CMD10 FBA_CMD11 FBA_CMD12 FBA_CMD13 FBA_CMD14 FBA_CMD15 FBA_CMD16 FBA_CMD17 FBA_CMD18 FBA_CMD19 FBA_CMD20 FBA_CMD21 FBA_CMD22 FBA_CMD23 FBA_CMD24 FBA_CMD25 FBA_CMD26
FBA_CLK0 FBA_CLK0 FBA_CLK1 FBA_CLK1
FBA_DEBUG
FBA_REFCLK FBA_REFCLK
FBA_PLLVDD
FBA_PLLAVDD
FBA_PLLGND
SNN_GPU_A12
A12
SNN_GPU_A15
A15
SNN_GPU_A18
A18
SNN_GPU_A21
A21
SNN_GPU_A24
A24
SNN_GPU_A27
A27
SNN_GPU_A3
A3
SNN_GPU_A30
A30
SNN_GPU_A6
A6
SNN_GPU_A9
A9
SNN_GPU_AA32
AA32
SNN_GPU_AD32
AD32
SNN_GPU_AG32
AG32
SNN_GPU_AK32
AK32
SNN_GPU_C32
C32
SNN_GPU_F32
F32
SNN_GPU_J32
J32
SNN_GPU_M32
M32
SNN_GPU_R32
R32
SNN_GPU_V32
V32
AA25 AA26 AB25 AB26 G11 G12 G15 G18 G21 G22 H11 H12 H15 H18 H21 H22 L25 L26 M25 M26 R25 R26 V25 V26
FBACMD0
P32
FBACMD1
U27
FBACMD2
P31
FBACMD3
U30
FBACMD4
Y31
FBACMD5
W32
FBACMD6
W31
FBACMD7
T32
FBACMD8
V27
FBACMD9
T28
FBACMD10
T31
FBACMD11
U32
FBACMD12
W29
FBACMD13
W30
FBACMD14
T27
FBACMD15
V28
FBACMD16
V30
FBACMD17
U31
FBACMD18
R27
FBACMD19
V29
FBACMD20
T30
FBACMD21
W28
FBACMD22
R29
FBACMD23
R30
FBACMD24
P29
FBACMD25
U28
SNN_FBA_CMD<26>
Y32
FBACLK0
P28
FBACLK0*
R28
FBACLK1
Y27
FBACLK1*
AA27
SNN_FBA_DBI0
Y30
RFU RFU
SNN_FBA_DBI1
AC26
FBA_DEBUG
AC27
SNN_FBA_REFCLK
D32
SNN_FBA_REFCLK*
D31
SNN_FBA_PLLVDD
G23
FBA_PLLAVDD
G25 G24
GND
PLACE BELOW GPU
C574 4700PF
25V 10% X7R 0402 COMMON
C726 4700PF
25V 10% X7R 0402 COMMON
C594 4700PF
25V 10% X7R 0402 COMMON
C610 4700PF
25V 10% X7R 0402 COMMON
C576 4700PF
25V 10% X7R 0402 COMMON
C597 .022UF
16V 10% X7R 0402 COMMON
C600 .022UF
16V 10% X7R 0402 COMMON
C732 .022UF
16V 10% X7R 0402 COMMON
C575 .022UF
16V 10% X7R 0402 COMMON
C578 .1UF
16V 10% X7R 0402 COMMON
C651 .1UF
16V 10% X7R 0402 COMMON
C631 .1UF
16V 10% X7R 0402 COMMON
C573 .1UF
16V 10% X7R 0402 COMMON
C707 4700PF
25V 10% X7R 0402 COMMON
C606 4700PF
25V 10% X7R 0402 COMMON
C683 4700PF
25V 10% X7R 0402 COMMON
C567 4700PF
25V 10% X7R 0402 COMMON
C579 .1UF
16V 10% X7R 0402 COMMON
C622 .022UF
16V 10% X7R 0402 COMMON
C671 .022UF
16V 10% X7R 0402 COMMON
C577 .022UF
16V 10% X7R 0402 COMMON
C596 .022UF
16V 10% X7R 0402 COMMON
C615 .1UF
16V 10% X7R 0402 COMMON
C614 .1UF
16V 10% X7R 0402 COMMON
C652 220PF
50V 5% C0G 0402 COMMON
C743 1UF
6.3V 10% X7R 0603 COMMON
FBVDDQ
C569 1UF
6.3V 10% X7R 0603 COMMON
C603 .1UF
16V 10% X7R 0402 COMMON
C659 1UF
6.3V 10% X7R 0603 COMMON
C617 1UF
6.3V 10% X7R 0603 COMMON
GND
GND
GND
GND
GND
FBACMD[25..0]
0 1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
3,4,4
OUT
3,4,4
OUT
3,5,5
OUT
3,5,5
OUT
TP501
FBACMD11
3,4,5
OUT
CKE
R67 10K
PD REQUIRED F O R INITIALIZA T ION OF DDR2
5%
0402
COMMON
GND
FBVDDQ
R502
10K
5%
0402
FBACMD12
COMMON
R503
10K
5%
0402
PD REQUIRED F O R INITIALIZA T ION OF DDR2
COMMON
GND
PLACE close to balls
C607 .01UF
25V 10% X7R 0402 COMMON
C608 .1UF
16V 10% X7R 0402 COMMON
C619 1UF
6.3V 10% X5R 0402 COMMON
LB501
COMMONIND_SMD_0603
180R@100MHz
FBA CMD/ADDR TERMINATIONS:
FBACMD22
FBACMD1
FBACMD9
FBACMD10
FBACMD19
FBACMD20
3,4,5 3,4,5
C642
4.7UF
6.3V 10% X5R 0603 COMMON
GND
PEX1V2
RP13A
1 8
RP13B
2 7
RP23B
FBACMD1
2 7
RP23A
1 8
RP14A
FBACMD9
1 8
RP14B
2 7
RP15B
FBACMD10
2 7
RP15A
1 8
RP24D
FBACMD19
4 5
RP24C
3 6
RP21C
FBACMD20
3 6
RP21D
4 5
BI BI
DDR2 OPERATION:
1) During initialization CKE and ODT low
2) Runtime .. CKE h ig h and O DT operated by FBACMD<12> state machine
3) No termination rpak for F BACMD<11> or FBACMD<12> pins
FBVDDQ
150
FBACMD24
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
FBACMD3
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
FBACMD5
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
FBACMD14
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
150
FBACMD21
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
FBACMD0
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
RP20A
FBACMD24
1 8
RP20B
2 7
RPAK_PAR_4_2010
RP16C
FBACMD3
3 6
RP16D
4 5
RP19B
2 7
RP19A
1 8
RP22C
FBACMD14
3 6
RP22D
4 5
RP17A
FBACMD21
1 8
RP17B
2 7
RP13C
FBACMD0
3 6
RP13D
4 5
FBVDDQ
FBACMD6
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMON
+/-5%
FBACMD4
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
FBACMD15
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
FBACMD16
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
150
FBACMD23
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
FBACMD2
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
RP18B
FBACMD6
2 7
RP18A
1 8
RP18D
4 5
RP18C
3 6
RP17D
FBACMD15
4 5
RP17C
3 6
RP24B
FBACMD16
2 7
RP24A
1 8
RP21A
1 8
FBACMD23
RP21B
2 7
RP20C
FBACMD2
3 6
RP20D
4 5
FBVDDQ
FBACMD13
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
FBACMD8
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
FBACMD17
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
FBACMD18
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
FBACMD25
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
FBACMD7
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
RP19C
FBACMD13
3 6
RP19D
4 5
RP23C
FBACMD8
3 6
RP23D
4 5
RP15D
FBACMD17
4 5
RP15C
3 6
RP14C
FBACMD18
3 6
RP14D
4 5
RP16A
FBACMD25
1 8
RP16B
2 7
RP22A
FBACMD7
1 8
RP22B
2 7
FBVDDQ
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
3,4,4
3,5,5
FBADQS[7..0]
FBADQSN[7..0]
3,4,5
C503 .01UF
25V 10% X7R 0402 COMMON
GND
FBACLK0
3,4,4
FBACLK0*
IN
FBACLK1
IN
3,5,5
FBACLK1*
IN IN
FBA_PLLAVDD
FBA_VREF
IN
FBAD[63..0]
IN
3,4,5
FBADQS0
BI
0
0
FBADQS1
1
FBADQSN1
1
FBADQS2
2
FBADQSN2
2
FBADQS3
3
FBADQSN3
3
FBADQS4
4
FBADQSN4
4
FBADQS5
5
FBADQSN5
5
FBADQS6
6
FBADQSN6
6
FBADQS7
7
FBADQSN7
7
FBADQSN7
FBADQM[7..0] FBACMD[25..0]
IN
3,4,5
IN
C505
C504
.01UF
.01UF
25V
25V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
PLACE CLOSE TO
TERMINATION RISISTORS
DIFFPAIRNET
C727 .01UF
25V 10% X7R 0402 COMMON
12.0
12.0
C501
C506
1UF
.01UF
25V
6.3V
10%
10%
X7R
X7R 0603
0402
COMMON
COMMON
50OHM 1
NV_CRITICAL_NETNV_IMPEDANCEMIN_LINE_WIDTH
1100DIFFFBACLK0 1100DIFFFBACLK0 1100DIFFFBACLK1 1100DIFFFBACLK1
150OHM 1100DIFFFBADQS0 1100DIFFFBADQS0 1100DIFFFBADQS1 1100DIFFFBADQS1 1100DIFFFBADQS2 1100DIFFFBADQS2 1100DIFFFBADQS3 1100DIFFFBADQS3 1100DIFFFBADQS4 1100DIFFFBADQS4
1100DIFFFBADQS5 1100DIFFFBADQS5 1100DIFFFBADQS6 1100DIFFFBADQS6 1100DIFFFBADQS7 1100DIFFFBADQS7
156OHM
www.vinafix.vn
Micro-Star International Co., LTD.
MS-V067
Size Document Number Rev Custom
GPU: FB-Interface A
Date:
Tuesday, June 06, 2006
Sheet o f
320
0A
FBA MEMORY 1st bank 0..31
PLACE ALL DISCRETE COMPONENTS AS NEAR AS POSSIBLE TO MEMORY
3,3,5
3,3,5
3,3,5
3,3,5
3,3,5
FBACMD[25..0]
IN
USED ONLY FOR 1 G B DEVICES ---->
3,3,4 3,3,4
FBAD[63..0]
BI
FBADQM[7..0]
IN
FBADQS[7..0]
IN
FBADQSN[7..0]
IN
15 25 9 8
1 3 2 0 24 22 21 23 19 20 17 16 14
SNN_U8_FBAA<13> SNN_U8_FBAA<14> SNN_U8_FBAA<15>
10 18 7
11
FBACLK0
IN
FBACLK0*
IN
FBACMD12
12
SNN_U8_A2 SNN_U8_E2
FBADQM0
0
FBADQM1
1
FBADQM2
2
FBADQM3
3
FBADQS0 FBADQS0
0
FBADQS1
1
FBADQS2
2
FBADQS3
3
FBADQSN0
0
FBADQSN1
1
FBADQSN2
2
FBADQSN3
3
FBACMD15 FBACMD25 FBACMD9 FBACMD8
FBACMD1 FBACMD3 FBACMD2 FBACMD0 FBACMD24 FBACMD22 FBACMD21 FBACMD23 FBACMD19 FBACMD20 FBACMD17 FBACMD16 FBACMD14
FBACMD10 FBACMD18 FBACMD7
FBACMD11
K7 L7 K3 L8
M8 M3 M7 N2 N8 N3 N7 P2 P8 P3 M2 P7 R2 R8 R3 R7
L2 L3 L1
K2 J8 K8
K9
A2 E2
M6C
BGA_0084_P080_140X120 COMMON
1/2
RAS CAS WE CS
A<0> A<1> A<2> A<3> A<4> A<5> A<6> A<7> A<8> A<9> A<10> A<11> A<12> NC/A<13> NC/A<14> NC/A<15>
BA<0> BA<1> NC/BA<2>
CKE CLK CLK
ODT
NC NC
0
FBAD0
1
FBAD1
2
FBAD2
3
FBAD3
4
FBAD4
5
FBAD5
6
FBAD6
7
FBAD7
FBADQM0
FBADQSN0
8
FBAD8
9
FBAD9
10
FBAD10
11
FBAD11
12
FBAD12
13
FBAD13
14
FBAD14
15
FBAD15
FBADQM1 FBADQS1 FBADQSN1
A1
VDD
E1
VDD
J9
VDD
M9
VDD
R1
VDD
A9
VDDQ
C1
VDDQ
C3
VDDQ
C7
VDDQ
C9
VDDQ
E9
VDDQ
G1
VDDQ
G3
VDDQ
G7
VDDQ
G9
VDDQ
J1
VDDL
A3
VSS
E3
VSS
J3
VSS
N1
VSS
P9
VSS
A7
VSSQ
B2
VSSQ
B8
VSSQ
D2
VSSQ
D8
VSSQ
E7
VSSQ
F2
VSSQ
F8
VSSQ
H2
VSSQ
H8
VSSQ
J7
VSSL
J2
Vref
M6B
BGA_0084_P080_140X120 COMMON
D1 C2 B1 D3 C8 D7 B9 D9
B3 B7 A8
M6A
BGA_0084_P080_140X120 COMMON
H1 F1 H3 G2 H7 F9 H9 G8
F3 F7 E8
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
FBVDDQ
FBVDDQ
M5B
BGA_0084_P080_140X120
H3 H1 F1 H7
F9 H9
F3 F7 E8
C2 D1 D3 B1 C8 B9 D9 D7
B3 B7 A8
K7 L7 K3 L8
M8 M3 M7 N2 N8 N3 N7
P2 P8 P3
M2
P7 R2 R8 R3 R7
L2
L3
L1
K2
J8
K8
K9
A2
E2
M5A
BGA_0084_P080_140X120 COMMON
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
M5C
BGA_0084_P080_140X120 COMMON
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
COMMON
1/2
RAS CAS WE CS
A<0> A<1> A<2> A<3> A<4> A<5> A<6> A<7> A<8> A<9> A<10> A<11> A<12> NC/A<13> NC/A<14> NC/A<15>
BA<0> BA<1> NC/BA<2>
CKE CLK CLK
ODT
NC NC
2/2
2/2
3,3,4
IN
FBACMD15
15
FBACMD25
25
FBACMD9
9
FBACMD8
8
FBACMD1
1
FBACMD3
3
FBACMD2
2
FBACMD0
0
FBACMD24
24
FBACMD22
22
FBACMD21
21
FBACMD23
23
FBACMD19
19
FBACMD20
20
FBACMD17
17
FBACMD16
16
FBACMD14
14
SNN_U7_FBAA<13> SNN_U7_FBAA<14> SNN_U7_FBAA<15>
FBACMD10
10
FBACMD18
18
FBACMD7
GND
FBVDDQ
VREF_B
C510 .047UF
16V 10% X7R 0402 COMMON
GND
2/2
2/2
3,3,4
USED ONLY FOR 1 G B DEVICES ---->
R64 1K
1% 0402 COMMON
IN
4,5
OUT
R63 1K
1% 0402 COMMON
GND
FBACLK0 FBACLK0*
R501
0603
7
FBACMD11
11
FBACLK0 FBACLK0*
FBACMD12
12
SNN_U7_A2 SNN_U7_E2
16
FBAD16
17
FBAD17
18
FBAD18
19
FBAD19
20
FBAD20 FBAD21 FBAD22 FBAD23
FBADQM2 FBADQS2 FBADQSN2
FBAD24 FBAD25 FBAD26 FBAD27 FBAD28 FBAD29 FBAD30 FBAD31
FBADQM3 FBADQS3 FBADQSN3
G2
G8
21 22 23
24 25 26 27 28 29 30 31
475
COMMON
1%
FBVDDQ
A1
VDD
E1
VDD
J9
VDD
M9
VDD
R1
VDD
A9
VDDQ
C1
VDDQ
C3
VDDQ
C7
VDDQ
C9
VDDQ
E9
VDDQ
G1
VDDQ
G3
VDDQ
G7
VDDQ
G9
VDDQ
J1
VDDL
A3
VSS
E3
VSS
J3
VSS
GND
N1
VSS
P9
VSS
A7
VSSQ
B2
VSSQ
B8
VSSQ
D2
VSSQ
D8
VSSQ
E7
VSSQ
F2
VSSQ
F8
VSSQ
H2
VSSQ
H8
VSSQ
J7
VSSL
VREF_B
J2
Vref
C512 .047UF
16V 10% X7R 0402 COMMON
GND
4,5
OUT
FBVDDQ
GND
GND
FBVDDQ
GND
FBVDDQ
GND
FBVDDQ
GND
Place plane decoupling caps near DQS-DQM pairs.
C672 .1UF
16V 10% X5R 0402 COMMON
C54
C51
.1UF
.1UF
16V
16V
10%
10%
X5R
X5R
0402
0402
COMMON
COMMON
C542 .01UF
25V 10% X7R 0402 COMMON
C545 .1UF
16V 10% X7R 0402 COMMON
C541 1UF
6.3V 10% X5R 0402 COMMON
FBVDDQ
C530
C554
.1UF
.1UF
16V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
C532 .1UF
16V 10% X7R 0402 COMMON
C517 .01UF
25V 10% X7R 0402 COMMON
C621 .01UF
25V 10% X7R 0402 COMMON
GND
C687 .1UF
16V 10% X5R 0402 COMMON
C515 .01UF
25V 10% X7R 0402 COMMON
C55 .1UF
16V 10% X5R 0402 COMMON
C560 .1UF
16V 10% X5R 0402 COMMON
FBVDDQ
16V 10% X7R
COMMON
.01UF
25V 10% X7R
COMMON
.01UF
25V 10% X7R
COMMON
GND
16V 10% X5R
COMMON
C527
C531
1UF
.01UF
6.3V 25V
10%
10%
X7R
X7R
0603
0402
COMMON
COMMON
C548
C516 .1UF
.1UF
16V 10% X7R 0402
0402
COMMON
C529
C526 1UF
6.3V 10% X7R
0402
0603 COMMON
C519
C514
.01UF
25V 10% X7R 0402
0402
COMMON
C521
C685
.1UF
.01UF
25V
16V
10%
10%
X7R
X5R
0402
0402
COMMON
COMMON
C59
C57
.1UF
.1UF
16V 10% X5R 0402
0402
COMMON
C507 .1UF
16V 10% X5R 0402 COMMON
C60 .1UF
16V 10% X5R 0402 COMMON
FBVDDQ
C553 .01UF
25V 10% X7R 0402 COMMON
C547 1UF
6.3V 10% X5R 0402 COMMON
C518
C540
.1UF
.1UF
16V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
C765 .01UF
25V 10% X7R 0402 COMMON
GND
C58 .1UF
16V 10% X5R 0402 COMMON
www.vinafix.vn
Micro-Star International Co., LTD.
MS-V067
Size Document Number Rev Custom
FBA MEMORY 1st bank 0..31
Date:
Tuesday, June 06, 2006
Sheet o f
420
0A
FBA MEMORY 1st bank 32..63
PLACE ALL DISCRETE COMPONENTS AS NEAR AS POSSIBLE TO MEMORY
FBACMD[25..0]
3,3,4
SUBPARTITION BITS ---->
USED ONLY FOR 1 G B DEVICES ---->
3,3,4
3,3,4
IN
FBACMD15 FBACMD15
15
FBACMD25 FBACMD25
25
FBACMD9 FBACMD9
9
FBACMD8 FBACMD8
8
FBACMD1 FBACMD1
1
FBACMD3 FBACMD3
3
FBACMD13 FBACMD13
13
FBACMD4 FBACMD4
4
FBACMD5 FBACMD5
5
FBACMD6 FBACMD6
6
FBACLK1
3,3,5
IN
FBACLK1* FBACLK1*
3,3,5
IN
3,3,4
3,3,4
FBAD[63..0]
BI
FBADQM[7..0]
IN
FBADQS[7..0]
IN
FBADQSN[7..0]
IN
FBACMD21 FBACMD21
21
FBACMD23 FBACMD23
23
FBACMD19 FBACMD19
19
FBACMD20 FBACMD20
20
FBACMD17 FBACMD17
17
FBACMD16 FBACMD16
16
FBACMD14 FBACMD14
14
SNN_U10_FBAA<13> SNN_U10_FBAA<14> SNN_U10_FBAA<15>
FBACMD10 FBACMD10
10
FBACMD18 FBACMD18
18
FBACMD7 FBACMD7
7
FBACMD11 FBACMD11
11
FBACMD12
12
SNN_U10_A2 SNN_U10_E2
FBADQM4
4
FBADQM5
5
FBADQM6
6
FBADQM7
7
FBADQS4
4
FBADQS5
5
FBADQS6
6
FBADQS7
7
FBADQSN4
4
FBADQSN5
5
FBADQSN6
6
FBADQSN7
7
K7 L7 K3 L8
M8 M3 M7 N2 N8 N3 N7 P2 P8 P3 M2 P7 R2 R8 R3 R7
L2 L3 L1
K2 J8 K8
K9
A2 E2
M8C
BGA_0084_P080_140X120 COMMON
1/2
RAS CAS WE CS
A<0> A<1> A<2> A<3> A<4> A<5> A<6> A<7> A<8> A<9> A<10> A<11> A<12> NC/A<13> NC/A<14> NC/A<15>
BA<0> BA<1> NC/BA<2>
CKE CLK CLK
ODT
NC NC
32 33 34 35 36 37 38 39
40 41 42 43 44 45 46 47
FBADQM4 FBADQS4 FBADQSN4
FBADQM5 FBADQS5 FBADQSN5
FBAD32 FBAD33 FBAD34 FBAD35 FBAD36 FBAD37 FBAD38 FBAD39
FBAD40 FBAD41 FBAD42 FBAD43 FBAD44 FBAD45 FBAD46 FBAD47
M7B
F1 H1 G2 H3 G8
H7 F9 H9
F3 F7 E8
D1 D7 C2 B1 D3 B9 C8 D9
B3 B7 A8
BGA_0084_P080_140X120 COMMON
K7
RAS
L7
CAS
K3
WE
L8
M8 M3 M7
N2 N8 N3 N7 P2 P8 P3
M2
P7 R2 R8 R3 R7
L2 L3 L1
K2 J8 K8
K9
A2 E2
A
M7A
BGA_0084_P080_140X120 COMMON
2/2
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
M8B
BGA_0084_P080_140X120 COMMON
2/2
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
CS
A<0> A<1> A<2> A<3> A<4> A<5> A<6> A<7> A<8> A<9> A<10> A<11> A<12> NC/A<13> NC/A<14> NC/A<15>
BA<0> BA<1> NC/BA<2>
CKE CLK CLK
ODT
NC NC
1/2
FBVDDQ
A1
VDD
E1
VDD
J9
VDD
M9
VDD
R1
VDD
A9
VDDQ
C1
VDDQ
C3
VDDQ
C7
VDDQ
C9
VDDQ
E9
VDDQ
G1
VDDQ
G3
VDDQ
G7
VDDQ
G9
VDDQ
J1
VDDL
A3
VSS
E3
VSS
J3
VSS
GND
N1
VSS
P9
VSS
A7
VSSQ
B2
VSSQ
B8
VSSQ
D2
VSSQ
D8
VSSQ
E7
VSSQ
F2
VSSQ VSSQ VSSQ VSSQ
VSSL
Vref
FBVDDQ
F8 H2 H8
J7
VREF_A VREF_A
J2
GND
C
M7C
BGA_0084_P080_140X120 COMMON
B1
DQ<0>
D1
DQ<1>
C2
DQ<2>
D3
DQ<3>
D7
DQ<4>
B9
DQ<5>
D9
DQ<6>
C8
DQ<7>
B3
DQM
B7
DQS
A8
DQS
M8A
BGA_0084_P080_140X120 COMMON
F1
DQ<0>
H9
DQ<1>
F9
DQ<2>
H7
DQ<3>
G8
DQ<4>
H1
DQ<5>
G2
DQ<6>
H3
DQ<7>
F3
DQM
F7
DQS
E8
DQS
C513 .047UF
16V 10% X7R 0402 COMMON
2/2
2/2
R66 1K
1% 0402 COMMON
GND
SUBPARTITION BITS ---->
R65 1K
1% 0402 COMMON
USED ONLY FOR 1 G B DEVICES ---->
5,5
OUT
FBACLK1
15 25 9 8
1
3 13 4 5 6
21
23
19
20
17
16
14
SNN_U9_FBAA<13> SNN_U9_FBAA<14> SNN_U9_FBAA<15>
10
18
7
11
FBACMD12
12
SNN_U9_A2 SNN_U9_E2
FBAD48
48
FBAD49
49
FBAD50
50
FBAD51
51
FBAD52
52
FBAD53
53
FBAD54
54
FBAD55
55
FBADQM6 FBADQS6 FBADQSN6
FBAD56
56
FBAD57
57
FBAD58
58
FBAD59
59
FBAD60
60
FBAD61
61
FBAD62
62
FBAD63
63
FBADQM7 FBADQS7 FBADQSN7
NAME
VREF_A VREF_B
FBVDDQ
A1
VDD
E1
VDD
J9
VDD
M9
VDD
R1
VDD
A9
VDDQ
C1
VDDQ
C3
VDDQ
C7
VDDQ
C9
VDDQ
E9
VDDQ
G1
VDDQ
G3
VDDQ
G7
VDDQ
G9
VDDQ
J1
VDDL
A3
VSS
E3
VSS
J3
VSS
GND
N1
VSS
P9
VSS
A7
VSSQ
B2
VSSQ
B8
VSSQ
D2
VSSQ
D8
VSSQ
E7
VSSQ
F2
VSSQ
F8
VSSQ
H2
VSSQ
H8
VSSQ
J7
VSSL
J2
Vref
GND
C511 .047UF
16V 10% X7R 0402 COMMON
5,5
IN
FBVDDQ
FBVDDQ
FBVDDQ
FBVDDQ
MIN_LINE_WIDTH
12.0
12.0
C520
C550
C534 .1UF
16V 10% X7R 0402 COMMON
GND
C537 .01UF
25V 10% X7R 0402 COMMON
GND
C538 .1UF
16V 10% X7R 0402 COMMON
GND
C549 .01UF
25V 10% X7R 0402 COMMON
GND
.01UF
25V 10% X7R 0402 COMMON
C552 .01UF
25V 10% X7R 0402 COMMON
C536 1UF
6.3V 10% X5R 0402 COMMON
C551
10% X7R 0402
.01UF
25V
COMMON
C522 .01UF
25V 10% X7R 0402 COMMON
C523 .01UF
25V 10% X7R 0402 COMMON
C533 .01UF
25V 10% X7R 0402 COMMON
C528 1UF
6.3V 10% X5R 0402 COMMON
.1UF
16V 10% X7R 0402 COMMON
C525 1UF
6.3V 10% X7R 0603 COMMON
C546 .1UF
16V 10% X7R 0402 COMMON
C535 .1UF
16V 10% X7R 0402 COMMON
C544 .1UF
16V 10% X7R 0402 COMMON
C543 .1UF
16V 10% X7R 0402 COMMON
C539 .1UF
16V 10% X7R 0402 COMMON
C524 1UF
6.3V 10% X7R 0603 COMMON
5,5
OUT
4,4
OUT
FBACLK1
3,3,5
IN
R504
FBACLK1*
475
COMMON0603
1%
3,3,5
IN
www.vinafix.vn
Micro-Star International Co., LTD.
MS-V067
Size Document Number Rev Custom
FBA MEMORY 1st bank 32..63
Date:
Tuesday, June 06, 2006
Sheet o f
520
0A
GPU: FB-Interface C
FBCCMD23
FBCCMD16
RP1A
FBCCMD24
1 8
RP1B
2 7
RP7B
FBCCMD1
2 7
RP7A
1 8
RP4A
FBCCMD9
1 8
RP4B
2 7
RP6B
FBCCMD10
2 7
RP6A
1 8
RP9D
FBCCMD16
4 5
RP9C
3 6
RP3B
FBCCMD23
2 7
RP3A
1 8
6,7,8
IN
6,7,8
IN
C750
4.7UF
6.3V 10% X5R 0603 COMMON
GND
DDR2 OPERATION:
1) During initialization CKE and ODT low
2) Runtime .. CK E high and ODT operated by debug state machine
3) No termination rpak for CKE or DEBUG pins
FBVDDQ
FBCCMD22
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
FBVDDQ
FBCCMD22
FBCCMD3
FBCCMD3
GND
FBCCMD13
FBCCMD13
FBCCMD14
FBCCMD14
GND
FBVDDQ
FBCCMD21
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
+/-5%
+/-5%
PEX1V2_F
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
FBCDQS[7..0]
FBCDQSN[7..0]
FBCCMD2
GND
6,7,7 6,7,7 6,8,8 6,8,8
6,7,8 6,7,8
6,7,8
RP2A
1 8
RPAK_PAR_4_2010
+/-5%
RP2B
2 7
+/-5%
RP8C
3 6
+/-5%
RP8D
4 5
+/-5%
RP12A
1 8
+/-5%
RP12B
2 7
+/-5%
RP5C
3 6
+/-5%
RP5D
4 5
+/-5%
RP10A
FBCCMD21
1 8
RP10B
2 7
RP1C
FBCCMD2
3 6
RP1D
4 5
IN IN IN IN IN
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
IN IN IN IN IN IN
150
COMMON
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
+/-5%
+/-5%
+/-5%
+/-5%
FBCCLK0 FBCCLK0*
FBCCLK1
FBCCLK1* FBC_PLLAVDD FBCDQS0 FBCDQSN0 FBCDQS1
FBCDQS2 FBCDQSN2 FBCDQS3 FBCDQSN3 FBCDQS4 FBCDQSN4 FBCDQS5 FBCDQSN5 FBCDQS6 FBCDQSN6 FBCDQS7 FBCDQSN7
FBCAL_PD FBCAL_PU FBCAL_TERM FBCDQM[7..0] FBCCMD[25..0] FBCD[63..0]
FBVDDQ
FBVDDQ
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
GND
GND
FBVDDQ
FBVDDQ
FBCCMD4
FBCCMD5
FBCCMD15
FBCCMD19
RP11A
FBCCMD4
1 8
RP11B
2 7
RP11C
FBCCMD5
3 6
RP11D
4 5
RP10D
FBCCMD15
4 5
RP10C
3 6
RP9B
FBCCMD19
2 7
RP9A
1 8
+/-5%
+/-5%
+/-5%
+/-5%
+/-5%
+/-5%
+/-5%
+/-5%
FBCCMD6
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
FBCCMD8
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
GND
FBVDDQ
FBCCMD17
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
FBCCMD18
150
COMMONRPAK_PAR_4_2010
150
COMMONRPAK_PAR_4_2010
GND
FBVDDQ
FBCCMD20
RP3D
150
FBCCMD20
4 5
COMMONRPAK_PAR_4_2010
+/-5%
RP3C
150
3 6
COMMONRPAK_PAR_4_2010
RP2C
FBCCMD0
3 6
RP2D
4 5
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
12.0
12.0
12.0
12.0
FBCCMD0
GND
RP12D
FBCCMD6
4 5
RP12C
3 6
RP7C
FBCCMD8
3 6
RP7D
4 5
RP6D
FBCCMD17
4 5
RP6C
3 6
RP4C
FBCCMD18
3 6
RP4D
4 5
FBCCMD25
FBCCMD7
FBVDDQ
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
150
COMMONRPAK_PAR_4_2010
+/-5%
GND
FBVDDQ
RP8A
150
FBCCMD25
1 8
COMMONRPAK_PAR_4_2010
+/-5%
RP8B
150
2 7
COMMONRPAK_PAR_4_2010
+/-5%
RP5A
150
FBCCMD7
1 8
COMMONRPAK_PAR_4_2010
+/-5%
RP5B
150
2 7
COMMONRPAK_PAR_4_2010
+/-5%
GND
NV_CRITICAL_NETNV_IMPEDANCEMIN_LINE_WIDTHDIFFPAIRNET
1100DIFFFBCCLK0 1100DIFFFBCCLK0 1100DIFFFBCCLK1 1100DIFFFBCCLK1
1100DIFFFBCDQS0 1100DIFFFBCDQS0 1100DIFFFBCDQS1 1100DIFFFBCDQS1 1100DIFFFBCDQS2 1100DIFFFBCDQS2 1100DIFFFBCDQS3 1100DIFFFBCDQS3 1100DIFFFBCDQS4 1100DIFFFBCDQS4 1100DIFFFBCDQS5 1100DIFFFBCDQS5 1100DIFFFBCDQS6 1100DIFFFBCDQS6 1100DIFFFBCDQS7 1100DIFFFBCDQS7
150OHM 156OHM 150OHM
Micro-Star International Co., LTD.
MS-V067
Size Document Number Rev Custom
GPU: FB-Interface C
Date:
Tuesday, June 06, 2006
Sheet o f
0A
620
6,7,8
6,7,8
6,7,8
6,7,8
FBCD[63..0]
BI
FBCD0
0
FBCD1
1
FBCD2
2
FBCD3
3
FBCD4
4
FBCD5
5
FBCD6
6
FBCD7
7
FBCD8
8
FBCD9
9
FBCD10
10
FBCD11
11
FBCD12
12
FBCD13
13
FBCD14
14
FBCD15
15
FBCD16
16
FBCD17
17
FBCD18
18
FBCD19
19
FBCD20
20
FBCD21
21
FBCD22
22
FBCD23
23
FBCD24
24
FBCD25
25
FBCD26
26
FBCD27
27
FBCD28
28
FBCD29
29
FBCD30
30
FBCD31
31
FBCD32
32
FBCD33
33
FBCD34
34
FBCD35
35
FBCD36
36
FBCD37
37
FBCD38
38
FBCD39
39
FBCD40
40
FBCD41
41
FBCD42
42
FBCD43
43
FBCD44
44
FBCD45
45
FBCD46
46
FBCD47
47
FBCD48
48
FBCD49
49
FBCD50
50
FBCD51
51
FBCD52
52
FBCD53
53
FBCD54
54
FBCD55
55
FBCD56
56
FBCD57
57
FBCD58
58
FBCD59
59
FBCD60
60
FBCD61
61
FBCD62
62
FBCD63
63
FBCDQM[7..0]
OUT
FBCDQS[7..0]
BI
FBCDQSN[7..0]
BI
FBCDQM0
0
FBCDQM1
1
FBCDQM2
2
FBCDQM3
3
FBCDQM4
4
FBCDQM5
5
FBCDQM6
6
FBCDQM7
7
FBCDQS0
0
FBCDQS1
1
FBCDQS2
2
FBCDQS3
3
FBCDQS4
4
FBCDQS5
5
FBCDQS6
6
FBCDQS7
7
FBCDQSN0
0
FBCDQSN1 FBCDQSN1
1
FBCDQSN2
2
FBCDQSN3
3
FBCDQSN4
4
FBCDQSN5
5
FBCDQSN6
6
FBCDQSN7
7
SNN_FBC_VREF
G1C
BGA_0820_P100_330X330_G3_128B COMMON
3/14 FBC
B7
FBCD0
A7
FBCD1
C7
FBCD2
A2
FBCD3
B2
FBCD4
C4
FBCD5
A5
FBCD6
B5
FBCD7
F9
FBCD8
F10
FBCD9
D12
FBCD10
D9
FBCD11
E12
FBCD12
D11
FBCD13
E8
FBCD14
D8
FBCD15
E7
FBCD16
F7
FBCD17
D6
FBCD18
D5
FBCD19
D3
FBCD20
E4
FBCD21
C3
FBCD22
B4
FBCD23
C10
FBCD24
B10
FBCD25
C8
FBCD26
A10
FBCD27
C11
FBCD28
C12
FBCD29
A11
FBCD30
B11
FBCD31
B28
FBCD32
C27
FBCD33
C26
FBCD34
B26
FBCD35
C30
FBCD36
B31
FBCD37
C29
FBCD38
A31
FBCD39
D28
FBCD40
D27
FBCD41
F26
FBCD42
D24
FBCD43
E23
FBCD44
E26
FBCD45
E24
FBCD46
F23
FBCD47
B23
FBCD48
A23
FBCD49
C25
FBCD50
C23
FBCD51
A22
FBCD52
C22
FBCD53
C21
FBCD54
B22
FBCD55
E22
FBCD56
D22
FBCD57
D21
FBCD58
E21
FBCD59
E18
FBCD60
D19
FBCD61
D18
FBCD62
E19
FBCD63
A4
FBCDQM0
E11
FBCDQM1
F5
FBCDQM2
C9
FBCDQM3
C28
FBCDQM4
F24
FBCDQM5
C24
FBCDQM6
E20
FBCDQM7
C5
FBCDQS_WP0
E10
FBCDQS_WP1
E5
FBCDQS_WP2
B8
FBCDQS_WP3
A29
FBCDQS_WP4
D25
FBCDQS_WP5
B25
FBCDQS_WP6
F20
FBCDQS_WP7
C6
FBCDQS_RN0
E9
FBCDQS_RN1
E6
FBCDQS_RN2
A8
FBCDQS_RN3
B29
FBCDQS_RN4
E25
FBCDQS_RN5
A25
FBCDQS_RN6
F21
FBCDQS_RN7
A28
FB_VREF2
FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT
FBC_CMD0 FBC_CMD1 FBC_CMD2 FBC_CMD3 FBC_CMD4 FBC_CMD5 FBC_CMD6 FBC_CMD7 FBC_CMD8
FBC_CMD9 FBC_CMD10 FBC_CMD11 FBC_CMD12 FBC_CMD13 FBC_CMD14 FBC_CMD15 FBC_CMD16 FBC_CMD17 FBC_CMD18 FBC_CMD19 FBC_CMD20 FBC_CMD21 FBC_CMD22 FBC_CMD23 FBC_CMD24 FBC_CMD25 FBC_CMD26
FBC_CLK0 FBC_CLK0 FBC_CLK1 FBC_CLK1
FBC_DEBUG
FBC_REFCLK FBC_REFCLK
FBC_PLLVDD
FBC_PLLAVDD
FBC_PLLGND
FBCAL_PD_VDDQ
FBCAL_PU_GND
FBCAL_TERM_GND
SNN_GPU_AA23
AA23
SNN_GPU_AB23
AB23
SNN_GPU_H16
H16
SNN_GPU_H17
H17
SNN_GPU_J10
J10
SNN_GPU_J23
J23
SNN_GPU_J24
J24
SNN_GPU_J9
J9
SNN_GPU_K11
K11
SNN_GPU_K12
K12
SNN_GPU_K21
K21
SNN_GPU_K22
K22
SNN_GPU_K24
K24
SNN_GPU_K9
K9
SNN_GPU_L23
L23
SNN_GPU_M23
M23
SNN_GPU_T25
T25
SNN_GPU_U25
U25
FBCCMD0
C13
FBCCMD1
A16
FBCCMD2
A13
FBCCMD3
B17
FBCCMD4
B20
FBCCMD5
A19
FBCCMD6
B19
FBCCMD7
B14
FBCCMD8
E16
FBCCMD9
A14
FBCCMD10
C15
FBCCMD11 FBCCMD11
B16
FBCCMD12
F17
FBCCMD13
C19
FBCCMD14
D15
FBCCMD15
C17
FBCCMD16
A17
FBCCMD17
C16
FBCCMD18
D14
FBCCMD19
F16
FBCCMD20
C14
FBCCMD21
C18
FBCCMD22
E14 B13 E15 F15 A20
FBCCLK0
E13
FBCCLK0*
F13
FBCCLK1
F18
FBCCLK1*
E17
C20
RFU
D1
RFU
F12 B1
C1
G8 G10 G9
GND
K26 H26 J26
FBCCMD23 FBCCMD24 FBCCMD25 SNN_FBC_CMD<26>
SNN_FBC_DBI0 SNN_FBC_DBI1
FBC_DEBUG
SNN_FBC_REFCLK SNN_FBC_REFCLK*
SNN_FBC_PLLVDD
FBC_PLLAVDD
FBCAL_PD
FBCAL_PU
FBCAL_TERM
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
R509
R507
0402
FBVDDQ
C56 .01UF
25V 10% X7R 0402 COMMON
GND
PLACE CLOSE TO
TERMINATION RISISTORS
FBCCMD[25..0]
0 1 2 3 4 5 6 7 8 9
6,7,8
OUT
CKE
R60 10K
5%
0402
COMMON
C706
C633
.01UF
.01UF
25V
25V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
PD REQUIRED F O R INITIALIZA T ION OF DDR2
C502 .01UF
25V 10% X7R 0402 COMMON
C682 1UF
6.3V 10% X7R 0603 COMMON
FBC CMD/ADDR TERMINATIONS:
FBCCMD24
FBCCMD1
FBCCMD9
FBCCMD10
GND
6,7,7
OUT
6,7,7
OUT
6,8,8
OUT
6,8,8
OUT
TP502
FBCCMD12
COMMON
R510
10K
5%
0402
FBCCMD12
PD REQUIRED F O R INITIALIZA T ION OF DDR2
COMMON
FBVDDQ
R511
10K
5%
0402
GND
FBVDDQ
40.2
COMMON0402
1%
40.2
COMMON0402
1%
R508
0
COMMON
5%
GND GND
Place clos e to bal ls
C711 .01UF
25V 10% X7R 0402 COMMON
C702 .1UF
16V 10% X7R 0402 COMMON
C716 1UF
6.3V 10% X5R 0402 COMMON
LB506
180R@100MHz
COMMONIND_SMD_0603
www.vinafix.vn