MSI MS-V046 Schematic 10

1
2
3
4
5
6
7
8
HGFEDCBA
MS-V046 VER 10
1
A A
Base on P295-A00 DESIGN NV43 300/267MHZ 128MB/256MB/512MB DDR2 84-FBGA to modify V046
1
PAGE SUMMARY:
Page1: P295 Overview Page2: PCI EXPRESS, NVVDD, VDD33 Page3: FB BANK A, FBVTT TERMINATIONS, FBVDDQ DECOUPLING Page4: FB BANK C, FBVTT TERMINATIONS Page5: MEMORY PARTITION A 0..31
2
B B
3
C C
4
Page6: MEMORY PARTITION A 32..63 Page7: MEMORY PARTITION C 0..31 Page8: MEMORY PARTITION C 32..63 Page9: GPU GND Page10: DACA - VGA Page11: DACB - TVOUT, VIDEO IN Page12: DACC - VGA Page13: STRAPS, FANSINK, MECHANICALS Page14: GPIO, HDCP ROM, VBIOS ROM, FAN CONTROL Page15: INTERNAL TMDS LINK A/B Page16: INTERNAL TMDS LINK C/D Page17: MIOA, MIOB, NVPLL Page18: Power Supply (Linears) Page19: FBVDD with MS11 HW monitor Page20: NVVDD with MS11 GPIO CTRLer
Page Changed:
Chage FBVDD & NVVDD Power solution for MS11 20050829 Adding DACA _ C R S ET SETTING 20050829 Adding Bridge & termernation resister for DVI 20050829 Pull 3v3 f or GPIO30-33 of GPIO controll er 20050831
-20051031
1.Page 10&15 : Modify DACA RGB Net J4,J502 RGB Net need connect,
2.Page 12&16 : Modify I2CB_SDA and I2CB_SCL Net
3.Page 19 : Memory sence circuit CSP & CSN swap
4.Page 19 : Modify Capacitor 1,2 to C1111,C2222
5.For G73 reserve circuit a.2.5V a.2.5V
Suggestion : r em o ve MS11 FBVDD VI D co ntrol
-20051125
Reserve G73 circuit Reserve FBVTT circuit Reserve HDCP circuit
2
3
4
D D
5
Micro-Star International Co., LTD.
Size Document Number Rev Custom
A B D F H
1
2
3
4
E GC
5
6
Date:
7
MS-V046
P295 Overview
Thursday, December 01, 2005
Sheet of
8
5
120
www.vinafix.vn
1
2
3
4
5
6
7
8
HGFEDCBA
0
NS
5%
PEX_RESET_IN*
PEX_REFFCLK
PEX_REFFCLK*
PEX_TXX0 PEX_TXX0*
PEX_RX0 PEX_RX0*
PEX_TXX1 PEX_TXX1*
PEX_RX1 PEX_RX1*
PEX_TXX2 PEX_TXX2*
PEX_RX2
PEX_RX2*
PEX_TXX3 PEX_TXX3*
PEX_RX3
PEX_RX3*
PEX_TXX4 PEX_TXX4*
PEX_RX4
PEX_RX4*
PEX_TXX5 PEX_TXX5*
PEX_RX5
PEX_RX5*
PEX_TXX6 PEX_TXX6*
PEX_RX6
PEX_RX6*
PEX_TXX7 PEX_TXX7*
PEX_RX7
PEX_RX7*
PEX_TXX8
PEX_RX8
PEX_RX8*
PEX_TXX9 PEX_TXX9*
PEX_RX9
PEX_RX9*
PEX_TXX10
PEX_TXX10*
PEX_RX10 PEX_RX10*
PEX_TXX11
PEX_TXX11*
PEX_RX11 PEX_RX11*
PEX_TXX12
PEX_TXX12*
PEX_RX12 PEX_RX12*
PEX_TXX13
PEX_TXX13*
PEX_RX13 PEX_RX13*
PEX_TXX14
PEX_TXX14*
PEX_RX14 PEX_RX14*
PEX_TXX15
PEX_TXX15*
PEX_RX15 PEX_RX15*
PEX_TXX8*
12V_PEX
Place Close to fingers
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
C814 .01UF
16V 10% X7R 0402 COMMON
1 2
3V3_PEX
C34 .1UF
25V 10% X7R 0603 COMMON
R607
0402
5
4
U505
3
SC70-5 NS
GND
C796
.1UF
10%
X5R 0402COMMON
C788
.1UF
10%COMMON
0402X5R 10V
C779
.1UF
10%X5R 10VCOMMON
0402
C769
.1UF
10%COMMON
0402X5R 10V
C757
.1UF
0402X5R 10% 10V
C748
.1UF
0402X5R 10% 10V
C732
.1UF
0402X5R 10% 10V
C715
.1UF
0402X5R 10% 10V
C682
.1UF
0402X5R 10% 10V
C661
.1UF
0402X5R 10% 10V
C634
.1UF
0402X5R 10% 10V
C609
.1UF
0402X5R 10% 10V
C603
.1UF
0402X5R 10% 10V
C590
.1UF
0402X5R 10% 10V
C581
.1UF
0402X5R 10% 10V
C578
.1UF
0402X5R 10% 10V
12V_PEX
3V3_PEX
3V3AUX
C47
1
A A
.1UF
25V 10% X7R 0603 COMMON
GND
PRSNT
SNN_PE_PRSNT2_A
SNN_PE_RSVD2
2
SNN_PE_PRSNT2_B SNN_PE_RSVD3 SNN_PE_RSVD4 SNN_PE_RSVD5
B B
SNN_PE_PRSNT2_C SNN_PE_RSVD6
3
SNN_PE_RSVD7 SNN_PE_RSVD8
C C
4
D D
5
16X PCIe Interface
CN1
EDGE_PEX_164_FINGER
CON_X16
COMMON
12V_PEX
B1
GND
3V3_PEX
3V3AUX
+12V
B2
+12V
A2
+12V
A3
+12V
B3
+12V/RSVD
B8
+3V3
A9
+3V3
A10
+3V3
B10
+3V3AUX
A1
PRSNT1
B17
PRSNT2
B12
RSVD
B4
GND
A4
GND
B7
GND
A12
GND
B13
GND
A15
GND
B16
GND
B18
GND
A18
GND
GND
B31
PRSNT2
A19
RSVD
B30
RSVD
A32
RSVD
A20
GND
B21
GND
B22
GND
A23
GND
A24
GND
B25
GND
B26
GND
A27
GND
A28
GND
B29
GND
A31
GND
B32
GND
GND
B48
PRSNT2
A33
RSVD
A34
GND
B35
GND
B36
GND
A37
GND
A38
GND
B39
GND
B40
GND
A41
GND
A42
GND
B43
GND
B44
GND
A45
GND
A46
GND
B47
GND
B49
GND
A49
GND
GND
B81
PRSNT2
A50
RSVD
B82
RSVD
A51
GND
B52
GND
B53
GND
A54
GND
A55
GND
B56
GND
B57
GND
A58
GND
A59
GND
B60
GND
B61
GND
A62
GND
A63
GND
B64
GND
B65
GND
A66
GND
A67
GND
B68
GND
B69
GND
A70
GND
A71
GND
B72
GND
B73
GND
A74
GND
A75
GND
B76
GND
B77
GND
A78
GND
A79
GND
B80
GND
A82
GND
END OF X1
END OF X4
END OF X8
END OF X16
TRST* JTAG1
TCLK JTAG2
TDI JTAG3 TDO JTAG4 TMS JTAG5
SMCLK SMDAT
WAKE
PERST
REFCLK REFCLK
PERP0 PERN0
PETP0 PETN0
PERP1 PERN1
PETP1 PETN1
PERP2 PERN2
PETP2 PETN2
PERP3 PERN3
PETP3 PETN3
PERP4 PERN4
PETP4 PETN4
PERP5 PERN5
PETP5 PETN5
PERP6 PERN6
PETP6 PETN6
PERP7 PERN7
PETP7 PETN7
PERP8 PERN8
PETP8 PETN8
PERP9 PERN9
PETP9 PETN9
PERP10 PERN10
PETP10 PETN10
PERP11 PERN11
PETP11 PETN11
PERP12 PERN12
PETP12 PETN12
PERP13 PERN13
PETP13 PETN13
PERP14 PERN14
PETP14 PETN14
PERP15 PERN15
PETP15 PETN15
SNN_PEXJTAG_TRST*
B9
SNN_PEXJTAG_TCLK
A5
PEXJTAG_TDIO
A6
R623
A7
0402
A8
SNN_PEXJTAG_TMS
SNN_PEX_SMCLK
B5
SNN_PEX_SMDAT
B6
SNN_PEX_WAKE*
B11
A11
A13 A14
A16 A17
B14 B15
A21 A22
B19 B20
A25 A26
B23 B24
A29 A30
B27 B28
A35 A36
B33 B34
A39 A40
B37 B38
A43 A44
B41 B42
A47 A48
B45 B46
A52 A53
B50 B51
A56 A57
B54 B55
A60 A61
B58 B59
A64 A65
B62 B63
A68 A69
B66 B67
A72 A73
B70 B71
A76 A77
B74 B75
A80 A81
B78 B79
A B D F H
1
2
C37 1UF
16V 10% X5R 0603 COMMON
GND
0
COMMON
5%
PEX_RESET_BUF_IN*
R606
0402
5%
C798
C795
10V
C786
0402
C776
0402 X5R10%10V
C767 .1UF
0402 X5R10%10V COMMON
C752
0402 X5R10%10V
C745
0402 X5R10%10V
C731
0402 X5R10%10V
C707
0402 X5R10%10V
C677
0402 X5R10%10V
C654
0402 X5R10%10V
C623 .1UF
C604
0402 X5R10%10V
C598
0402 X5R10%10V
C587
0402 X5R10%10V
C579
0402 X5R10%10V
C573
0402 X5R10%10V
3V3_PEX
PEX_REFCLK
COMMON0402 10V 10% X5R
PEX_REFCLK*
U6A
C805
BGA820_P10_33X33MM
1UF
COMMON
16V 10%
1/14 PCI_EXPRESS
X5R 0603 COMMON
GND
AH15
PEX_RST
AG12
RFU
AH13
RFU
AM12
PEX_TSTCLK_OUT
AM11
PEX_TSTCLK_OUT
AH14
PEX_REFCLK
AJ14
PEX_REFCLK
AJ15
PEX_TX0
AK15
PEX_TX0
AK13
PEX_RX0
AK14
PEX_RX0
AH16
PEX_TX1
AG16
PEX_TX1
AM14
PEX_RX1
AM15
PEX_RX1
AG17
PEX_TX2
AH17
PEX_TX2
AL15
PEX_RX2
AL16
PEX_RX2
AG18
PEX_TX3
AH18
PEX_TX3
AK16
PEX_RX3
AK17
PEX_RX3
AK18
PEX_TX4
AJ18
PEX_TX4
AL17
PEX_RX4
AL18
PEX_RX4
AJ19
PEX_TX5
AH19
PEX_TX5
AM18
PEX_RX5
AM19
PEX_RX5
AG20
PEX_TX6
AH20
PEX_TX6
AK19
PEX_RX6
AK20
PEX_RX6
AG21
PEX_TX7
AH21
PEX_TX7
AL20
PEX_RX7
AL21
PEX_RX7
AK21
PEX_TX8
AJ21
PEX_TX8
AM21
PEX_RX8
AM22
PEX_RX8
AJ22
PEX_TX9
AH22
PEX_TX9
AK22
PEX_RX9
AK23
PEX_RX9
AG23
PEX_TX10
AH23
PEX_TX10
AL23
PEX_RX10
AL24
PEX_RX10
AK24
PEX_TX11
AJ24
PEX_TX11
AM24
PEX_RX11
AM25
PEX_RX11
AJ25
PEX_TX12
AH25
PEX_TX12
AK25
PEX_RX12
AK26
PEX_RX12
AH26
PEX_TX13
AG26
PEX_TX13
AL26
PEX_RX13
AL27
PEX_RX13
AK27
PEX_TX14
AJ27
PEX_TX14
AM27
PEX_RX14
AM28
PEX_RX14
AJ28
PEX_TX15
AH27
PEX_TX15
AL28
PEX_RX15
AL29
PEX_RX15
PEX_IOVDD PEX_IOVDD PEX_IOVDD PEX_IOVDD PEX_IOVDD PEX_IOVDD
PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ PEX_IOVDDQ
VDD_LP VDD_LP VDD_LP VDD_LP VDD_LP VDD_LP
VDD_SENSE
GND_SENSE
VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33 VDD33
PEX_PLLAVDD PEX_PLLDVDD
PEX_PLLGND
C807
C806 .1UF
.01UF
16V
10V 10%
10% X7R
X5R
0402
0402
COMMON
COMMON
100
COMMON
R547
0402
PEX_RESET_GPU_IN*
R546 10K
5%
SNN_PD_VDDQ
0402
SNN_PU_GND
COMMON
GND
PEX_TSTCLK
200
PEX_TSTCLK*
PEX_TSTCLK*
NS
1%
C799
.1UF
.1UF
X5R10%
10V0402
COMMON
.1UF
PEX_TX0 PEX_TX0*
COMMON
10%0402 X5R10V
.1UF
PEX_TX1 PEX_TX1*
COMMONX5R10%10 V
.1UF
PEX_TX2 PEX_TX2*
COMMON
PEX_TX3 PEX_TX3*
.1UF
PEX_TX4 PEX_TX4*
COMMON
.1UF
PEX_TX5 PEX_TX5*
COMMON
.1UF
PEX_TX6 PEX_TX6*
COMMON
.1UF
PEX_TX7 PEX_TX7*
COMMON
.1UF
PEX_TX8 PEX_TX8*
COMMON
.1UF
PEX_TX9 PEX_TX9*
COMMON
PEX_TX10 PEX_TX10*
COMMON04 02 X5R10%10V
.1UF
PEX_TX11 PEX_TX11*
COMMON
.1UF
PEX_TX12 PEX_TX12*
COMMON
.1UF
PEX_TX13 PEX_TX13*
COMMON
.1UF
PEX_TX14 PEX_TX14*
COMMON
.1UF
PEX_TX15 PEX_TX15*
COMMON
160mA
Place near balls
C638
C624
.1UF
.1UF
16V
16V
10%
AD23 AF23 AF24 AF25 AG24 AG25
Place near balls
AC16 AC17 AC21 AC22 AE18 AE21 AE22 AF12 AF18 AF21 AF22
K16
VDD
K17
VDD
N13
VDD
N14
VDD
N16
VDD
N17
VDD
N19
VDD
P13
VDD
P14
VDD
P16
VDD
P17
VDD
P19
VDD
R16
VDD
R17
VDD
NV_PLLAVDD
T13
VDD
T14
VDD
T15
VDD
T18
VDD
T19
VDD
U13
VDD
U14
VDD
U15
VDD
U18
VDD
U19
VDD
V16
VDD
V17
VDD
W13
VDD
W14
VDD
W16
VDD
W17
VDD
W19
VDD
Y13
VDD
Y14
VDD
Y16
VDD
Y17
VDD
Y19
VDD
Y20
VDD
P20 T20 T23 U20 U23 W20
N20 M21
GND
VDD33
AC11 AC12 AC24 AD24 AE11 AE12 H7 J7 K7 L10 L7 L8 M10
PEX_PLLVDD
AF15 AE15 AE16
GND
SNN_G3_NC0
AM8
NC
SNN_G3_NC1
AM9
NC
SNN_G3_NC2
B32
NC
SNN_G3_NC3
J6
NC
X7R 0402 COMMON
C663 .1UF
16V 10% X7R 0402 COMMON
Place near balls
C659 .1UF
16V 10% X7R 0402 COMMON
C672 .1UF
16V 10% X7R 0402 COMMON
C699 .1UF
16V 10% X7R 0402 COMMON
0.5
0.2
C692 .1UF
16V 10% X7R 0402 COMMON
10% X7R 0402 COMMON
C641 .1UF
16V 10% X7R 0402 COMMON
Place near balls
20mA
C646 .1UF
16V 10% X7R 0402 COMMON
C666 .1UF
16V 10% X7R 0402 COMMON
C678 .1UF
16V 10% X7R 0402 COMMON
C656 .1UF
16V 10% X7R 0402 COMMON
Place near balls
C700 .1UF
10V 10% X5R 0402 COMMON
C696 .1UF
10V 10% X5R 0402 COMMON
Place near balls
C676 .1UF
X5R 0402 COMMON
C680 4700PF
25V X7R 0402 COMMON
C642 .1UF
16V 10% X7R 0402 COMMON
10%10V
C608 1UF
6.3V 10% X5R 0402 COMMON
10%
C688 .47UF
6.3V 10% X5R 0402 COMMON
C695 .47UF
6.3V 10% X5R 0402 COMMON
C651 .47UF
6.3V 10% X5R 0402 COMMON
C718
C712
4700PF
25V 10% X7R 0402 COMMON
4700PF
25V 10% X7R 0402 COMMON
C653 1UF
6.3V 10% X5R 0402 COMMON
C675 .01UF
16V X7R 0402 COMMON
C691 .01UF
16V X7R 0402 COMMON
C628 .47UF
6.3V 10% X5R 0402 COMMON
Place Close to GPU
C667 1UF
6.3V 10% X5R 0402 COMMON
C686 .47UF
6.3V 10% X5R 0402 COMMON
C687 .47UF
6.3V 10% X5R 0402 COMMON
C729 .022UF
16V 10% X7R 0402 COMMON
C706 .022UF
16V 10% X7R 0402 COMMON
10%
10%
C614
4.7UF
X5R 0603 COMMON
Place Near BGA
Place Near BGA
C644
4.7UF
6.3V 10% X5R 0603 COMMON
10%6.3V
C674 1UF
6.3V 10% X5R 0402 COMMON
Place Close to GPU
NVVDD
C655 10UF
6.3V 20% X5R 0805 COMMON
C703 10UF
6.3V 20% X5R 0805 COMMON
C658 .47UF
6.3V 10% X5R 0402 COMMON
C730
.022UF
16V 10% X7R 0402 COMMON
C616
.022UF
16V 10% X7R 0402 COMMON
E GC
3
4
5
6
C770
4.7UF
6.3V 10% X5R 0603 COMMON
GND
C662
4.7UF
6.3V X5R 0603 COMMON
GND
LB540
220R@100MHz
0603
COMMON
C671 10UF
6.3V 20% X5R 0805 COMMON
GND
GND
10%
C689
4.7UF
6.3V X5R 0603 COMMON
PEX1V2
Place Close to GPU
C612
4.7UF
6.3V 10% X5R 0603 COMMON
C793 22UF
6.3V 20% X5R 0805 COMMON
GND
ADD for G73
PEX1V2
LB541
0603
GND
GND
GND
C683
4.7UF
6.3V 10% X5R 0603 COMMON
GND
LB506
0603
120R@100MHz
C750 1UF
16V 10% X5R 0603 COMMON
LB503
0603 COMMON
180R@100MHz
10%
C698 .01UF
16V 10% X7R 0402 COMMON
PEX1V2
220R@100MHz
COMMON
NVVDD
COMMON
3V3_PEX
C673 .01UF
16V 10% X7R 0402 COMMON
NV_PLLAVDD
C4453
0.1UF
16V 10% X7R 0402 COMMON
NVVDD
GND
C4454
4.7UF
6.3V 20% X5R 0603 COMMON
PEX1V2
C643
4.7UF
6.3V X5R 0603 COMMON
GND
C684 .01UF
16V 10% X7R 0402 COMMON
10%
7
NET RULES
NV_IMPEDANCE
PEX_TX0 PEX_TX0* PEX_TX1 PEX_TX1* PEX_TX2 PEX_TX2* PEX_TX3 PEX_TX3* PEX_TX4 PEX_TX4* PEX_TX5 PEX_TX5* PEX_TX6 PEX_TX6* PEX_TX7 PEX_TX7* PEX_TX8 PEX_TX8* PEX_TX9 PEX_TX9* PEX_TX10 PEX_TX10* PEX_TX11 PEX_TX11* PEX_TX12 PEX_TX12* PEX_TX13 PEX_TX13* PEX_TX14 PEX_TX14* PEX_TX15 PEX_TX15*
PEX_TXX0 PEX_TXX0* PEX_TXX1 PEX_TXX1* PEX_TXX2 PEX_TXX2* PEX_TXX3 PEX_TXX3* PEX_TXX4 PEX_TXX4* PEX_TXX5 PEX_TXX5* PEX_TXX6 PEX_TXX6* PEX_TXX7 PEX_TXX7* PEX_TXX8 PEX_TXX8* PEX_TXX9 PEX_TXX9* PEX_TXX10 PEX_TXX10* PEX_TXX11 PEX_TXX11* PEX_TXX12 PEX_TXX12* PEX_TXX13 PEX_TXX13* PEX_TXX14 PEX_TXX14* PEX_TXX15 PEX_TXX15*
PEX_RX0 PEX_RX0* PEX_RX1 PEX_RX1* PEX_RX2 PEX_RX2* PEX_RX3 PEX_RX3* PEX_RX4 PEX_RX4* PEX_RX5 PEX_RX5* PEX_RX6 PEX_RX6* PEX_RX7 PEX_RX7* PEX_RX8 PEX_RX8* PEX_RX9 PEX_RX9* PEX_RX10 PEX_RX10* PEX_RX11 PEX_RX11* PEX_RX12 PEX_RX12* PEX_RX13 PEX_RX13* PEX_RX14 PEX_RX14* PEX_RX15 PEX_RX15*
PEX_REFCLK PEX_REFCLK* PEX_TSTCLK PEX_TSTCLK* PEX_REFFCLK PEX_REFFCLK*
NET NAME
NET NAME MIN_LINE_WIDTH
DIFFPAIRNET NV_CRITICAL_NET
PEX_TX2 1100DIFF PEX_TX3 1100DIFF PEX_TX3 1100DIFF PEX_TX4 1100DIFF PEX_TX4 1100DIFF PEX_TX5 1100DIFF PEX_TX5 1100DIFF PEX_TX6 100DIFF 1
PEX_TX7 1100DIFF PEX_TX7 100DIFF 1 PEX_TX8 100DIFF 1
PEX_TXX4 100DIFF 1
PEX_TXX8 1100DIFF
PEX_TXX14 100DIFF 1
PEX_RX3 100DIFF 1
PEX_RX5 1100DIFF PEX_RX5 1100DIFF
PEX_RX9 1100DIFF
PEX_RX13 1100DIFF PEX_RX13 1100DIFF
PEX_RX15 100DIFF 1
PEX_TSTCLK 100DIFF 1 PEX_REFFCLK 100DIFF 1
PEX_PLLVDD
12V_PEX
3V3_PEX
MIN_LINE_WIDTH
5.5 12V20
3.0 3.3V20
Micro-Star International Co., LTD.
Size Document Number Rev Custom
Date:
MS-V046
16X PCIe Interface
Friday, December 02, 2005
100DIFFPEX_TX2 1
100DIFF 1PEX_TX10
100DIFF 1PEX_TX11 100DIFF 1PEX_TX11 100DIFFPEX_TX12 1
100DIFFPEX_TX13 1 100DIFFPEX_TX13 1
100DIFFPEX_TXX7 1
100DIFFPEX_TXX13 1
100DIFFPEX_RX1 1 100DIFFPEX_RX2 1 100DIFFPEX_RX2 1
100DIFFPEX_RX4 1 100DIFFPEX_RX4 1
100DIFFPEX_RX6 1
100DIFFPEX_RX14 1 100DIFFPEX_RX14 1 100DIFFPEX_RX15 1
100DIFFPEX_REFCLK 1 100DIFFPEX_REFCLK 1 100DIFF 1PEX_TSTCLK
100DIFF 1PEX_REFFCLK
NET_SPACING_TYPE
1100DIFFPEX_TX0 1100DIFFPEX_TX0 1100DIFFPEX_TX1 1100DIFFPEX_TX1
1100DIFFPEX_TX6
1100DIFFPEX_TX8 1100DIFFPEX_TX9 1100DIFFPEX_TX9
1100DIFFPEX_TX10
1100DIFFPEX_TX12
1100DIFFPEX_TX14 1100DIFFPEX_TX14 1100DIFFPEX_TX15 1100DIFFPEX_TX15
1100DIFFPEX_TXX0 1100DIFFPEX_TXX0 1100DIFFPEX_TXX1 1100DIFFPEX_TXX1 1100DIFFPEX_TXX2 1100DIFFPEX_TXX2 1100DIFFPEX_TXX3 1100DIFFPEX_TXX3 1100DIFFPEX_TXX4
1PEX_TXX5 100DIFF 1100DIFFPEX_TXX5 1100DIFFPEX_TXX6 1100DIFFPEX_TXX6 1100DIFFPEX_TXX7
1PEX_TXX8 100DIFF 1PEX_TXX9 100DIFF 1100DIFFPEX_TXX9 1100DIFFPEX_TXX10 1100DIFFPEX_TXX10 1100DIFFPEX_TXX11 1100DIFFPEX_TXX11 1100DIFFPEX_TXX12 1100DIFFPEX_TXX12 1100DIFFPEX_TXX13
1PEX_TXX14 100DIFF 1100DIFFPEX_TXX15 1100DIFFPEX_TXX15
1100DIFFPEX_RX0 1100DIFFPEX_RX0 1100DIFFPEX_RX1
1PEX_RX3 100DIFF
1100DIFFPEX_RX6 1100DIFFPEX_RX7 1100DIFFPEX_RX7 1100DIFFPEX_RX8 1100DIFFPEX_RX8 1PEX_RX9 100DIFF
1PEX_RX10 100DIFF 1PEX_RX10 100DIFF 1100DIFFPEX_RX11 1100DIFFPEX_RX11 1PEX_RX12 100DIFF 1100DIFFPEX_RX12
10MIL12
VOLTAGENV_NET_MAX_CURRENT
Sheet of
8
1
2
3
4
5
220
www.vinafix.vn
1
2
3
4
5
6
7
8
HGFEDCBA
AD29 AD28
AC28
AM30
AM31
AD30 AC31 AC32
AG27 AH28
AG28 AG29 AD27
AC30 AG30
AH30
AH29
AE29
AB29 AA30
AB30 AF30
AJ31 AJ30 AJ32 AK29
AL30 AE32 AE30 AE31
AB32 AB31
AF28
AF27 AE28
AA29 AK30
AB28 AL32 AF32
AA28
AL31 AF31
2
N27 M27 N28 L29 K27 K28 J29 J28 P30 N31 N30 N32 L31 L30 J30 L32 H30 K30 H31 F30 H32 E31 D30 E30 H28 H29 E29 J27 F27 E27 E28 F28
Y28
M29 M30 G30 F29
L28 K31 G32 G28
M28 K32 G31 G27
E32
U6B
BGA820_P10_33X33MM COMMON
2/14 FBA
FBAD0 FBAD1 FBAD2 FBAD3 FBAD4 FBAD5 FBAD6 FBAD7 FBAD8 FBAD9 FBAD10 FBAD11 FBAD12 FBAD13 FBAD14 FBAD15 FBAD16 FBAD17 FBAD18 FBAD19 FBAD20 FBAD21 FBAD22 FBAD23 FBAD24 FBAD25 FBAD26 FBAD27 FBAD28 FBAD29 FBAD30 FBAD31 FBAD32 FBAD33 FBAD34 FBAD35 FBAD36 FBAD37 FBAD38 FBAD39 FBAD40 FBAD41 FBAD42 FBAD43 FBAD44 FBAD45 FBAD46 FBAD47 FBAD48 FBAD49 FBAD50 FBAD51 FBAD52 FBAD53 FBAD54 FBAD55 FBAD56 FBAD57 FBAD58 FBAD59 FBAD60 FBAD61 FBAD62 FBAD63
FBADQM0 FBADQM1 FBADQM2 FBADQM3 FBADQM4 FBADQM5 FBADQM6 FBADQM7
FBADQS_WP0 FBADQS_WP1 FBADQS_WP2 FBADQS_WP3 FBADQS_WP4 FBADQS_WP5 FBADQS_WP6 FBADQS_WP7
FBADQS_RN0 FBADQS_RN1 FBADQS_RN2 FBADQS_RN3 FBADQS_RN4 FBADQS_RN5 FBADQS_RN6 FBADQS_RN7
FB_VREF1
FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD FBVDD
FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ FBVDDQ
FBA_CMD0 FBA_CMD1 FBA_CMD2 FBA_CMD3 FBA_CMD4 FBA_CMD5 FBA_CMD6 FBA_CMD7 FBA_CMD8
FBA_CMD9 FBA_CMD10 FBA_CMD11 FBA_CMD12 FBA_CMD13 FBA_CMD14 FBA_CMD15 FBA_CMD16 FBA_CMD17 FBA_CMD18 FBA_CMD19 FBA_CMD20 FBA_CMD21 FBA_CMD22 FBA_CMD23 FBA_CMD24 FBA_CMD25 FBA_CMD26
FBA_CLK0 FBA_CLK0 FBA_CLK1 FBA_CLK1
FBA_DEBUG
FBA_REFCLK FBA_REFCLK
FBA_PLLVDD
FBA_PLLAVDD
FBA_PLLGND
SNN_FBVDD0
A12
SNN_FBVDD1
A15
SNN_FBVDD2
A18
SNN_FBVDD3
A21
SNN_FBVDD4
A24
SNN_FBVDD5
A27
SNN_FBVDD6
A3
SNN_FBVDD7
A30
SNN_FBVDD8
A6
SNN_FBVDD9
A9
SNN_FBVDD10
AA32
SNN_FBVDD11
AD32
SNN_FBVDD12
AG32
SNN_FBVDD13
AK32
SNN_FBVDD14
C32
SNN_FBVDD15
F32
SNN_FBVDD16
J32
SNN_FBVDD17
M32
SNN_FBVDD18
R32
SNN_FBVDD19
V32
AA25 AA26 AB25 AB26 G11 G12 G15 G18 G21 G22 H11 H12 H15 H18 H21 H22 L25 L26 M25 M26 R25 R26 V25 V26
P32 U27 P31 U30 Y31 W32 W31 T32 V27 T28 T31 U32 W29 W30 T27 V28 V30 U31 R27 V29 T30 W28 R29 R30 P29 U28 Y32
P28 R28 Y27 AA27
Y30
RFU
AC26
RFU
AC27 D32
D31
G23 G25 G24
GND
3
PLACE BELOW GPU
C596 4700PF
25V 10% X7R 0402 COMMON
C600 4700PF
25V 10% X7R 0402 COMMON
C637 4700PF
25V 10% X7R 0402 COMMON
C645 4700PF
25V 10% X7R 0402 COMMON
C613 4700PF
25V 10% X7R 0402 COMMON
COMMON
FBACMD[25..0]
0 1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
OUT OUT OUT OUT
R526
0
0402
5%
FBACMD0 FBACMD1 FBACMD2 FBACMD3 FBACMD4 FBACMD5 FBACMD6 FBACMD7 FBACMD8 FBACMD9 FBACMD10 FBACMD11 FBACMD11 FBACMD12 FBACMD12 FBACMD13 FBACMD14 FBACMD15 FBACMD16 FBACMD17 FBACMD18 FBACMD19 FBACMD20 FBACMD21 FBACMD22 FBACMD23 FBACMD24 FBACMD25
SNN_FBA_CMD26
FBACLK0 FBACLK0* FBACLK1 FBACLK1*
SNN_FBA_DBI0
SNN_FBA_DBI1
FBA_DEBUG_ODT
FBA_REFCLK
FBA_REFCLK*
FBA_PLLVDD
FBA_PLLAVDD
FBVDDQ
C591
C619
C593
C595 .022UF
16V 10% X7R 0402 COMMON
C597 .022UF
16V 10% X7R 0402 COMMON
C592 .022UF
16V 10% X7R 0402 COMMON
C626 .022UF
16V 10% X7R 0402 COMMON
.1UF
10V 10% X5R 0402 COMMON
C594 .1UF
10V 10% X5R 0402 COMMON
C602 .1UF
10V 10% X5R 0402 COMMON
C664 .1UF
10V 10% X5R 0402 COMMON
4700PF
25V 10% X7R 0402 COMMON
C743 4700PF
25V 10% X7R 0402 COMMON
C681 4700PF
25V 10% X7R 0402 COMMON
C611 4700PF
25V 10% X7R 0402 COMMON
C627 .1UF
10V 10% X5R 0402 COMMON
.022UF
16V 10% X7R 0402 COMMON
C736 .022UF
16V 10% X7R 0402 COMMON
C665 .022UF
16V 10% X7R 0402 COMMON
C704 .022UF
16V 10% X7R 0402 COMMON
C717 .1UF
10V 10% X5R 0402 COMMON
C617 .1UF
10V 10% X5R 0402 COMMON
C629 220PF
50V 5% C0G 0402 COMMON
C615 .1UF
10V 10% X5R 0402 COMMON
C631
4.7UF
6.3V 10% X5R 0603 COMMON
C670
4.7UF
6.3V 10% X5R 0603 COMMON
GND
GND
GND
GND
GND
FBVDDQ
75
COMMON
75
75
COMMON
75
75
COMMON
75
COMMON
75
COMMON
75
COMMON
6
C566 .1UF
16V 10% X7R 0402 COMMON
4 5 3 6 3 6 4 5
FBVDDQ
FBACMD2
FBACMD3
GND
FBVDDQ
FBACMD13
FBACMD14
GND
RP26D
75
RPAK_8P4R_0402X4_20105%COMMON
RP26C
75
RPAK_8P4R_0402X4_2010
COMMON
5%
RP23C
75
RPAK_8P4R_0402X4_2010
COMMON
5%
RP23D
75
RPAK_8P4R_0402X4_2010COMMON
5%
C534 1UF
6.3V 10% X5R 0402 COMMON
DDR2 OPERATION:
1) During initialization CKE and ODT low
2) Runtime .. CKE high and ODT operated by debug state machine
3) No termination rpak for CKE or DEBUG pins
FBVDDQ
GND
C567
C559
C550 .01UF
16V 10% X7R 0402 COMMON
FBA CMD/ADDR TERMINATIONS:
FBACMD0
FBACMD1
FBACMD9
FBACMD10
C551 .01UF
16V 10% X7R 0402 COMMON
RP19A
1 8
RPAK_8P4R_0402X4_2010
RP19B
2 7
RPAK_8P4R_0402X4_20105%COMMON
RP25B
2 7
RPAK_8P4R_0402X4_2010
RP25A
1 8
RPAK_8P4R_0402X4_2010COMMON
RP15A
1 8
RPAK_8P4R_0402X4_2010
RP15B
2 7
RPAK_8P4R_0402X4_2010
RP16B
2 7
RPAK_8P4R_0402X4_2010
RP16A
1 8
RPAK_8P4R_0402X4_2010
FBACMD19
FBACMD20
5%
5%
5%
5%
5%
5%
5%
.1UF
OUT
CKE
RESET
R525
0
NS
0402
5%
C636
C635
.01UF
.1UF
10V
16V
10%
10%
X5R
X7R
0402
0402
COMMON
COMMON
C621
C622
.01UF
.1UF
16V
10V
10%
10%
X7R
X5R
0402
0402
COMMON
COMMON
OUT
R534
10K
PD REQUIRED FOR INITIALIZATION OF DDR2
5%
0402
FBVDDQ
COMMON
R524
10K
GND
5%
0402
NS
FBA_ODT
PD REQUIRED FOR INITIALIZATION OF DDR2
R523
10K
5% 0402
COMMON
GND
PLACE near GPUPLACE close to balls
LB501 180R@100MHz
COMMON0603
LB502
180R@100MHz
COMMON
0603
220R@100MHz
LB542
0603
COMMON
NC For G73
.01UF
16V 10% X7R 0402 COMMON
GND
OUT
A3V3
C73
4.7UF
6.3V 10% X5R 0603 COMMON
GND
NVVDD
PEX1V2
ADD for G73
GND
16V 10% X7R 0402 COMMON
FBVDDQ
R7317
R7318
100
100
5%
5%
0402
0402
COMMON
FBA_REFCLK FBA_REFCLK*
4
R7319 100
5% 0402 COMMON
COMMON
R7320 100
5% 0402 COMMON
GND
E GC
5
FB PARTITION A
1
A A
2
B B
3
C C
FBVDDQ
FBAD[63..0]
BI
FBADQM[7..0]
OUT
FBADQS[7..0]
BI
FBADQSN[7..0]
BI
FBAD0
0
FBAD1
1
FBAD2
2
FBAD3
3
FBAD4
4
FBAD5
5
FBAD6
6
FBAD7
7
FBAD8
8
FBAD9
9
FBAD10
10
FBAD11
11
FBAD12
12
FBAD13
13
FBAD14
14
FBAD15
15
FBAD16
16
FBAD17
17
FBAD18
18
FBAD19
19
FBAD20
20
FBAD21
21
FBAD22
22
FBAD23
23
FBAD24
24
FBAD25
25
FBAD26
26
FBAD27
27
FBAD28
28
FBAD29
29
FBAD30
30
FBAD31
31
FBAD32
32
FBAD33
33
FBAD34
34
FBAD35
35
FBAD36
36
FBAD37
37
FBAD38
38
FBAD39
39
FBAD40
40
FBAD41
41
FBAD42
42
FBAD43
43
FBAD44
44
FBAD45
45
FBAD46
46
FBAD47
47
FBAD48
48
FBAD49
49
FBAD50
50
FBAD51
51
FBAD52
52
FBAD53
53
FBAD54
54
FBAD55
55
FBAD56
56
FBAD57
57
FBAD58
58
FBAD59
59
FBAD60
60
FBAD61
61
FBAD62
62
FBAD63
63
FBADQM0
0
FBADQM1
1
FBADQM2
2
FBADQM3
3
FBADQM4
4
FBADQM5
5
FBADQM6
6
FBADQM7
7
FBADQS0
0
FBADQS1
1
FBADQS2
2
FBADQS3
3
FBADQS4
4
FBADQS5
5
FBADQS6
6
FBADQS7
7
FBADQSN0
0
FBADQSN1
1
FBADQSN2
2
FBADQSN3
3
FBADQSN4
4
FBADQSN5
5
FBADQSN6
6
FBADQSN7
7
4
C588 .1UF
COMMON0402
Rtop
Rbot
D D
5
10V 10%
1%
X5R 0402 NS
R535 1K
C589 .1UF
COMMON
1K
10V 10%
1%
X5R 0402
0402
COMMON
R536
GND
DDR3:
VREF = FBVDD Q * Rbot/(Rtop + Rbot)
VREF = 0.50 * FBVDDQ
0.9V = 1.8V * 1.0K/1.0K + 1.0K)DDR2:
VREF = 0.70 * FBVDDQ
1.26V = 1.8V * 2.7K/()1.15K + 2.7K)
FB_VREF1
A B D F H
1
RP14D 75
4 5
RPAK_8P4R_0402X4_2010COMMON
5%
RP14C
3 6
RPAK_8P4R_0402X4_2010
5%
RP17C
3 6
RPAK_8P4R_0402X4_2010
5%
RP17D
4 5
RPAK_8P4R_0402X4_20105%COMMON
RP21B
2 7
RPAK_8P4R_0402X4_2010
5%
RP21A
1 8
RPAK_8P4R_0402X4_2010
5%
RP24C
3 6
RPAK_8P4R_0402X4_2010
5%
RP24D
4 5
RPAK_8P4R_0402X4_2010
5%
FBACMD21
FBACMD22
NET DIFFPAIR
FBACLK0
FBACLK0*
FBACLK1
FBACLK1*
FBA_PLLVDD
FBA_PLLAVDD
FB_VREF1
FBAD[63..0]
FBADQS0 FBADQSN0
FBADQS1 FBADQSN1
FBADQS2 FBADQSN2
FBADQS3 FBADQSN3
FBADQS4 FBADQSN4
FBADQS5 FBADQSN5
FBADQS6 FBADQSN6
FBADQS7 FBADQSN7
FBADQM[7..0]
FBACMD[25..0]
FBA_ODT
FBVDDQ
75
COMMON
75
COMMON
75
GND
FBVDDQ
FBACMD15
75
COMMON
75
COMMON
75
COMMON
75
COMMON
GND
RP18A
1 8
RPAK_8P4R_0402X4_20105%COMMON
RP18B
2 7
RPAK_8P4R_0402X4_20105%COMMON
RP19C
3 6
RPAK_8P4R_0402X4_20105%COMMON
RP19D
4 5
RPAK_8P4R_0402X4_2010COMMON
5%
12
12
12
FBADQS0 1100DIFF
FBADQS3 1100DIFF
FBADQS4 1100DIFF FBADQS4 100DIFF 1
FBADQS5 100DIFF 1 FBADQS5 100DIFF 1
FBADQS6 1100DIFF
FBVDDQ
FBACMD4
FBACMD5
FBACMD16
75
75
75
75
FBVDDQ
FBACMD23
FBACMD24
GND
RP22B 75
2 7
RPAK_8P4R_0402X4_2010COMMON
RP22A
1 8
RPAK_8P4R_0402X4_2010COMMON
RP22D
4 5
RPAK_8P4R_0402X4_2010
RP22C 75
3 6
RPAK_8P4R_0402X4_2010
RP18D 75
4 5
RP18C
3 6
RPAK_8P4R_0402X4_2010
RP26B 75
2 7
RPAK_8P4R_0402X4_2010
RP26A
1 8
5%
75
5%
75
COMMON
5%
COMMON
5%
COMMONRPAK_8P4R_0402X4_2010
5%
75
COMMON
5%
COMMON
5%
75
COMMONRPAK_8P4R_0402X4_2010
5%
FBACMD6
GND
FBVDDQ
GND
RP23A
1 8
RPAK_8P4R_0402X4_201075COMMON
5%
RP23B
75
2 7
RPAK_8P4R_0402X4_20105%COMMON
RP20C5%75
3 6
COMMONRPAK_8P4R_0402X4_2010
RP20D 75
4 5
COMMON
RPAK_8P4R_0402X4_2010
5%
FBACMD8
FBACMD17
FBACMD18
FBVDDQ
GND
Micro-Star International Co., LTD.
Size Document Number Rev Custom
FB PARTITION A
Date:
Friday, December 02, 2005
7
100DIFF 1FBACLK0
100DIFF 1FBACLK0
100DIFF 1FBACLK1
100DIFF 1FBACLK1
100DIFF 1FBADQS7 100DIFF 1FBADQS7
50OHM 1
50OHM 1
RP21C 75
3 6
RPAK_8P4R_0402X4_201 05%COMMON
RP21D5%75
4 5
COMMONRPAK_8P4R_0402X4_2 010
RP25C
75
3 6
RPAK_8P4R_0402X4_201 05%COMMON
RP25D
75
4 5
RPAK_8P4R_0402X4_201 05%COMMON
RP16D
75
4 5
COMMONRPAK_8P4R_0402X4_2 010
5%
RP16C 75
3 6
RPAK_8P4R_0402X4_201 05%COMMON
RP15C
75
3 6
RPAK_8P4R_0402X4_201 0
COMMON
5%
RP15D 75
4 5
RPAK_8P4R_0402X4_201 0COMMON
5%
FBACMD25
FBACMD7
MS-V046
FBVDDQ
GND
FBVDDQ
GND
RP17A
1 8
RPAK_8P4R_0402X4_2010COMMON
RP17B 75
2 7
RPAK_8P4R_0402X4_2010
RP24A
1 8
RPAK_8P4R_0402X4_20105%COMMON
RP24B
2 7
RPAK_8P4R_0402X4_2010
NV_CRITICAL_NETMIN_LINE_WIDTH NV_IMPEDANCE
150OHM
1FBADQS0 100DIFF
1FBADQS1 100DIFF 1FBADQS1 100DIFF
1FBADQS2 100DIFF 1FBADQS2 100DIFF
1FBADQS3 100DIFF
1100DIFFFBADQS6
150OHM
FBVDDQ
75
5%
COMMON
5%
75
75
COMMON
5%
Sheet of
8
GND
320
1
2
3
4
5
www.vinafix.vn
1
2
3
4
5
6
7
8
HGFEDCBA
FB PARTITION C
C4459 1000PF
50V 10% X7R 0402 COMMON
C535 .1UF
16V 10% X7R 0402 COMMON
FBCCMD[25..0]
CKE
RESET
R544
0402
5%
FBVDDQ
R540
49.9
1% 0402 COMMON
R539
49.9
1% 0402 COMMON
NC For G73
C4461
C4460
1000PF
1000PF
50V
50V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
C693
C669
.1UF
.1UF
16V
16V
10%
10%
X7R
X7R
0402
0402
COMMON
COMMON
OUT
R541
0
NS 0402
5%
Place close t o b alls
C726 .01UF
16V 10% X7R 0402 COMMON
C690 .01UF
16V 10% X7R 0402 COMMON
C4455 .01UF
16V 10% X7R 0402 COMMON
C4462 1000PF
50V 10% X7R 0402 COMMON
FBC_REFCLK FBC_REFCLK*
R545
10K
5%
0402
COMMON
GND
R543
10K
5%
0402
COMMON
Place near GPU
GND
FBVTT
C4456 .01UF
16V 10% X7R 0402 COMMON
C4457
4.7UF
C4463 1000PF
6.3V 10%
50V
X5R
10%
0603
X7R
COMMON
0402 COMMON
FBVDDQ
R7321
R7322
100
100
5%
5%
0402
0402
COMMON
COMMON
R7323
R7324
100
100
5%
5%
0402
0402
COMMON
COMMON
GND
OUT
PD REQUIRED FOR INITIALIZATION OF DDR2
FBVDDQ
R542
10K
5%
0402
NS
FBC_ODT
PD REQUIRED FOR INITIALIZATION OF DDR2
OUT
NC For G73
LB507
0603 COMMON
C721
180R@100MHz
.1UF
10V 10% X5R 0402 COMMON
GND
LB504
0603 COMMON
180R@100MHz
C685 .1UF
10V 10% X5R 0402 COMMON
220R@100MHz
LB543
0603
ADD for G73
GND
NVVDD
A3V3
COMMON
GND
DDR2 OPERATION:
1) During initialization CKE and ODT low
2) Runtime .. CKE high and ODT operated by debug state machine
3) No termination rpak for CKE or DEBUG pins
FBC CMD/ADDR TERMINATIONS:
FBCCMD0
FBCCMD1
RP1A
75
1 8
RPAK_8P4R_0402X4_2010
5%
RP1B
75
2 7
RPAK_8P4R_0402X4_2010
5%
RP8B
75
2 7
RPAK_8P4R_0402X4_2010
5%
RP8A5%75
1 8
COMMON
COMMON
COMMON
COMMONRPAK_8P4R_0402X4_2010
FBVDDQ
FBVDDQ
FBCCMD9
RP5A 75
1 8
COMMON
RPAK_8P4R_0402X4_2010
5%
RP5B 75
2 7
COMMONRPAK_8P4R_0402X4_2010
FBCCMD10
5%
RP7B
75
2 7
RPAK_8P4R_0402X4_2010
COMMON
5%
RP7A
75
1 8
RPAK_8P4R_0402X4_2010COMMON
5%
FBVDDQ
FBCCMD19
FBCCMD20
RP10D 75
4 5
COMMON
RPAK_8P4R_0402X4_20 10
5%
RP10C
75
3 6
COMMON
RPAK_8P4R_0402X4_20 10
5%
RP4C
3 6
RPAK_8P4R_0402X4_20 1075COMMON
5%
RP4D
75
4 5
RPAK_8P4R_0402X4_20 10COMMON
5%
PEX1V2
U6C
BGA820_P10_33X33MM
F10 D12
E12 D11
C10 B10
A10 C11 C12 A11 B11 B28 C27 C26 B26 C30 B31 C29 A31 D28 D27 F26 D24 E23 E26 E24 F23 B23 A23 C25 C23 A22 C22 C21 B22 E22 D22 D21 E21 E18 D19 D18 E19
E11
C28 F24 C24 E20
E10
A29 D25 B25 F20
B29 E25 A25 F21
A28
B7 A7 C7 A2 B2 C4 A5 B5 F9
D9
E8 D8 E7 F7 D6 D5 D3 E4 C3 B4
C8
A4 F5
C9
C5 E5
B8
C6 E9 E6 A8
COMMON
3/14 FBC
FBCD0 FBCD1 FBCD2 FBCD3 FBCD4 FBCD5 FBCD6 FBCD7 FBCD8 FBCD9 FBCD10 FBCD11 FBCD12 FBCD13 FBCD14 FBCD15 FBCD16 FBCD17 FBCD18 FBCD19 FBCD20 FBCD21 FBCD22 FBCD23 FBCD24 FBCD25 FBCD26 FBCD27 FBCD28 FBCD29 FBCD30 FBCD31 FBCD32 FBCD33 FBCD34 FBCD35 FBCD36 FBCD37 FBCD38 FBCD39 FBCD40 FBCD41 FBCD42 FBCD43 FBCD44 FBCD45 FBCD46 FBCD47 FBCD48 FBCD49 FBCD50 FBCD51 FBCD52 FBCD53 FBCD54 FBCD55 FBCD56 FBCD57 FBCD58 FBCD59 FBCD60 FBCD61 FBCD62 FBCD63
FBCDQM0 FBCDQM1 FBCDQM2 FBCDQM3 FBCDQM4 FBCDQM5 FBCDQM6 FBCDQM7
FBCDQS_WP0 FBCDQS_WP1 FBCDQS_WP2 FBCDQS_WP3 FBCDQS_WP4 FBCDQS_WP5 FBCDQS_WP6 FBCDQS_WP7
FBCDQS_RN0 FBCDQS_RN1 FBCDQS_RN2 FBCDQS_RN3 FBCDQS_RN4 FBCDQS_RN5 FBCDQS_RN6 FBCDQS_RN7
FB_VREF2
FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT FBVTT
FBC_CMD0 FBC_CMD1 FBC_CMD2 FBC_CMD3 FBC_CMD4 FBC_CMD5 FBC_CMD6 FBC_CMD7 FBC_CMD8
FBC_CMD9 FBC_CMD10 FBC_CMD11 FBC_CMD12 FBC_CMD13 FBC_CMD14 FBC_CMD15 FBC_CMD16 FBC_CMD17 FBC_CMD18 FBC_CMD19 FBC_CMD20 FBC_CMD21 FBC_CMD22 FBC_CMD23 FBC_CMD24 FBC_CMD25 FBC_CMD26
FBC_CLK0 FBC_CLK0 FBC_CLK1 FBC_CLK1
FBC_DEBUG
FBC_REFCLK FBC_REFCLK
FBC_PLLVDD
FBC_PLLAVDD
FBC_PLLGND
FBCAL_PD_VDDQ
FBCAL_PU_GND
FBCAL_TERM_GND
AA23 AB23 H16 H17 J10 J23 J24 J9 K11 K12 K21 K22 K24 K9 L23 M23 T25 U25
C13 A16 A13 B17 B20 A19 B19 B14 E16 A14 C15 B16 F17 C19 D15 C17 A17 C16 D14 F16 C14 C18 E14 B13 E15 F15 A20
FBCCLK0
E13
FBCCLK0*
F13
FBCCLK1
F18
FBCCLK1*
E17
SNN_FBC_DBI0
C20
RFU
SNN_FBC_DBI1
D1
RFU
FBC_DEBUG_ODT
F12
FBC_REFCLK
B1
FBC_REFCLK*
C1
G8 G10 G9
GND
K26 H26 J26
C4458 1000PF
50V 10% X7R 0402 COMMON
FBVDDQ
C542
C543
1UF
.01UF
6.3V
25V
10%
10%
X5R
X7R
0402
0402
COMMON
COMMON
GND
FBCCMD0 FBCCMD1 FBCCMD2 FBCCMD3 FBCCMD4 FBCCMD5 FBCCMD6 FBCCMD7 FBCCMD8 FBCCMD9 FBCCMD10 FBCCMD11 FBCCMD11 FBCCMD12 FBCCMD12 FBCCMD13 FBCCMD14 FBCCMD15 FBCCMD16 FBCCMD17 FBCCMD18 FBCCMD19 FBCCMD20 FBCCMD21 FBCCMD22 FBCCMD23 FBCCMD24 FBCCMD25
SNN_FBC_CMD26
FBC_PLLVDD
FBC_PLLAVDD
FBCAL_PD
FBCAL_PU
FBCAL_TERM
COMMON
0 1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
OUT OUT OUT OUT
0
R537 0
5% 0402 COMMON
FBCD[63..0]
BI
1
A A
2
B B
3
FBCDQM[7..0]
OUT
FBCDQS[7..0]
BI
C C
FBCDQSN[7..0]
BI
4
D D
5
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
0 1 2 3 4 5 6 7
SNN_FB_VREF2
FBCD0 FBCD1 FBCD2 FBCD3 FBCD4 FBCD5 FBCD6 FBCD7 FBCD8 FBCD9 FBCD10 FBCD11 FBCD12 FBCD13 FBCD14 FBCD15 FBCD16 FBCD17 FBCD18 FBCD19 FBCD20 FBCD21 FBCD22 FBCD23 FBCD24 FBCD25 FBCD26 FBCD27 FBCD28 FBCD29 FBCD30 FBCD31 FBCD32 FBCD33 FBCD34 FBCD35 FBCD36 FBCD37 FBCD38 FBCD39 FBCD40 FBCD41 FBCD42 FBCD43 FBCD44 FBCD45 FBCD46 FBCD47 FBCD48 FBCD49 FBCD50 FBCD51 FBCD52 FBCD53 FBCD54 FBCD55 FBCD56 FBCD57 FBCD58 FBCD59 FBCD60 FBCD61 FBCD62 FBCD63
FBCDQM0 FBCDQM1 FBCDQM2 FBCDQM3 FBCDQM4 FBCDQM5 FBCDQM6 FBCDQM7
FBCDQS0 FBCDQS1 FBCDQS2 FBCDQS3 FBCDQS4 FBCDQS5 FBCDQS6 FBCDQS7
FBCDQSN0 FBCDQSN1 FBCDQSN2 FBCDQSN3 FBCDQSN4 FBCDQSN5 FBCDQSN6 FBCDQSN7
FBCCLK0
FBCCLK0*
FBCCLK1
FBCCLK1*
FBC_PLLVDD
FBC_PLLAVDD
FBC_VREF2
FBCD[63..0]
FBCDQS0 FBCDQSN0
FBCDQS1 FBCDQSN1
FBCDQS2 FBCDQSN2
FBCDQS3 FBCDQSN3
FBCDQS4 FBCDQSN4
FBCDQS5 FBCDQSN5
FBCDQS6 FBCDQSN6
FBCDQS7 FBCDQSN7
FBCDQM[7..0]
FBCCMD[25..0]
FBC_ODT
FBCAL_PD
FBCAL_PU
FBCAL_TERM
FBCDQS0 1100DIFF FBCDQS0 1100DIFF
FBCDQS1 1100DIFF FBCDQS1 1100DIFF
FBCDQS2 1100DIFF
FBCDQS3 1100DIFF
FBCDQS5 1100DIFF
FBVDDQ
FBCCMD2
RP3D
4 5
RPAK_8P4R_0402X4_20 10
RP3C
3 6
RPAK_8P4R_0402X4_20 10
FBCCMD3
RP9C 75
3 6
RPAK_8P4R_0402X4_20 10COMMON
RP9D
4 5
RPAK_8P4R_0402X4_20 10
GND
FBCCMD13
RP12A
1 8
RPAK_8P4R_0402X4_20 105%COMMON
RP12B
2 7
RPAK_8P4R_0402X4_20 10
FBCCMD14
RP6C
3 6
RPAK_8P4R_0402X4_20 10
RP6D 75
4 5
GND
FBCCMD21
RP11A
1 8
RP11B
2 7
RPAK_8P4R_0402X4_2010
FBCCMD22
3 6 4 5
RPAK_8P4R_0402X4_2010
GND
75
COMMON
5%
75
COMMON
5%
5%
75
COMMON
5%
75
75
COMMON
5%
75
COMMON
5%
COMMONRPAK_8P4R_0402X4 _2010
5%
RP1C 75
RP1D
FBCCMD4
RP13A
75
1 8
COMMONRPAK_8P4R_0402X4_2010
5%
RP13B5%75
2 7
FBCCMD23
FBCCMD24
RP13C
75
3 6
RPAK_8P4R_0402X4_2010
5%
RP13D 75
4 5
5%
RP11D 75
4 5
RPAK_8P4R_0402X4_2010
5%
RP11C 75
3 6
RPAK_8P4R_0402X4_2010
5%
RP10B
75
2 7
RPAK_8P4R_0402X4_2010
5%
RP10A 75
1 8
RPAK_8P4R_0402X4_2010
5%
COMMONRPAK_8P4R_0402X4_2010
COMMON
COMMONRPAK_8P4R_0402X4_2010
COMMON
COMMON
COMMON
COMMON
1 8
RPAK_8P4R_0402X4_2010
2 7
RPAK_8P4R_0402X4_2010COMMON
3 6
RPAK_8P4R_0402X4_20105%COMMON
4 5
RPAK_8P4R_0402X4_2010
FBCCMD5
GND
FBVDDQ
FBCCMD15
FBCCMD16
GND
FBVDDQ
75
COMMONRPAK_8P4R_0402X4_2010
5%
75
COMMON
5%
COMMONRPAK_8P4R_0402X4_2010
5%
75
COMMON
5%
GND
GND GND
A B D F H
1
2
3
4
E GC
5
6
7
NV_IMPEDANCE NV_CRITICAL_NETNET DIFFPAIR MIN_LINE_WIDTH
100DIFF 1FBCCLK0
100DIFF 1FBCCLK0
1100DIFFFBCCLK1
1100DIFFFBCCLK1
12
12
12
150OHM
1FBCDQS2 100DIFF
1100DIFFFBCDQS3
1100DIFFFBCDQS4 1FBCDQS4 100DIFF
1FBCDQS5 100DIFF
1100DIFFFBCDQS6 1100DIFFFBCDQS6
1100DIFFFBCDQS7 1100DIFFFBCDQS7
150OHM
150OHM
150OHM
12
12
12
FBVDDQ
FBCCMD6
FBCCMD8
GND
FBVDDQ
FBCCMD17
FBCCMD18
GND
FBVDDQ
RP4A
75
COMMON
5%
RP4B
75
5%
RP2C
75
RP2D
75
COMMON
5%
GND
Micro-Star International Co., LTD.
Size Document Number Rev Custom
FB PARTITION C
Date:
Friday, December 02, 2005
RP12D5%75
4 5
COMMONRPAK_8P4R_0402X4_2010
RP12C
3 6
RPAK_8P4R_0402X4_201075COMMON
5%
RP8C
75
3 6
RPAK_8P4R_0402X4_2010
COMMON
5%
RP8D
75
4 5
RPAK_8P4R_0402X4_20105%COMMON
RP7D
4 5
RPAK_8P4R_0402X4_201075COMMON
5%
RP7C5%75
3 6
COMMONRPAK_8P4R_0402X4_2010
RP5C
75
3 6
RPAK_8P4R_0402X4_2010
COMMON
5%
RP5D 75
4 5
COMMONRPAK_8P4R_0402X4_2010
5%
FBCCMD25
FBCCMD7
MS-V046
FBVDDQ
GND
FBVDDQ
GND
RP9A
1 8
RPAK_8P4R_0402X4_2010
RP9B 75
2 7
RPAK_8P4R_0402X4_2010
RP6A 75
1 8
RPAK_8P4R_0402X4_2010COMMON
RP6B
2 7
RPAK_8P4R_0402X4_2010COMMON
FBVDDQ
75
COMMON
5%
COMMON
5%
5%
75
5%
Sheet of
8
GND
420
1
2
3
4
5
www.vinafix.vn
1
2
3
4
5
6
7
8
HGFEDCBA
16x power/gnd pin pairs per mem 3x 0.022uf - 5.3 to 1 6x 4700uf - 2.7 to 1
FBA MEMORY 1st bank 0..31
PLACE ALL DISCRETE COMPONENTS AS NEAR AS POSSIBLE TO MEMORY
FBACMD[25..0]
IN
1
A A
2
B B
3
C C
4
D D
5
USED ONLY FOR 1GB DEVICES ---->
FBAD[63..0]
BI
FBADQM[7..0]
IN
FBADQS[7..0]
IN
FBADQSN[7..0]
IN
FBACLK0
IN
FBACLK0* FBACLK0*
IN
0
1
2
3
0
1
2
3
0
1
2
3
FBACMD15 FBACMD15
15
FBACMD25 FBACMD25
25
FBACMD9 FBACMD9
9
FBACMD8 FBACMD8
8
FBACMD1 FBACMD1
1
FBACMD3 FBACMD3
3
FBACMD2 FBACMD2
2
FBACMD0 FBACMD0
0
FBACMD24 FBACMD24
24
FBACMD22 FBACMD22
22
FBACMD21 FBACMD21
21
FBACMD23 FBACMD23
23
FBACMD19 FBACMD19
19
FBACMD20 FBACMD20
20
FBACMD17 FBACMD17
17
FBACMD16 FBACMD16
16
FBACMD14 FBACMD14
14
FBACMD10 FBACMD10
10
FBACMD18 FBACMD18
18
FBACMD7 FBACMD7
7
FBACMD11 FBACMD11
11
FBA_ODT FBA_ODT
IN
FBADQM0
FBADQM1
FBADQM2
FBADQM3
FBADQS0 FBADQS0
FBADQS1
FBADQS2
FBADQS3
FBADQSN0
FBADQSN1
FBADQSN2
FBADQSN3
M8 M3 M7 N2 N8 N3 N7
M2 R2
R8 R3 R7
K7 L7 K3 L8
P2 P8 P3
P7
L2 L3 L1
K2 J8 K8
K9
A2 E2
U10C
IC_K4N56163QF_84P COMMON
RAS CAS WE CS
A<0> A<1> A<2> A<3> A<4> A<5> A<6> A<7> A<8> A<9> A<10> A<11> A<12> NC/A<13> NC/A<14> NC/A<15>
BA<0> BA<1> NC/BA<2>
CKE CLK CLK
ODT
NC NC
0 1 2 3 4 5 6 7
8 9 10 11 12 13 14 15
1/2
FBAD0 FBAD1 FBAD2 FBAD3 FBAD4 FBAD5 FBAD6 FBAD7
FBADQM0
FBADQSN0
FBAD8 FBAD9 FBAD10 FBAD11 FBAD12 FBAD13 FBAD14 FBAD15
FBADQM1 FBADQS1 FBADQSN1
FBVDDQ
A1
VDD
E1
VDD
J9
VDD
M9
VDD
R1
VDD
A9
VDDQ
C1
VDDQ
C3
VDDQ
C7
VDDQ
C9
VDDQ
E9
VDDQ
G1
VDDQ
G3
VDDQ
G7
VDDQ
G9
VDDQ
J1
VDDL
A3
VSS
E3
VSS
J3
VSS
N1
VSS
GND
P9
VSS
A7
VSSQ
B2
VSSQ
B8
VSSQ
D2
VSSQ
D8
VSSQ
E7
VSSQ
F2
VSSQ
F8
VSSQ
H2
VSSQ
H8
VSSQ
J7
VSSL
VREF_B VREF_B
J2
Vref
D1 C2 B1 D3 C8 D7 B9 D9
B3 B7 A8
H1 F1 H3 G2 H7 F9 H9 G8
F3 F7 E8
U10B
IC_K4N56163QF_84P COMMON
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
U10A
IC_K4N56163QF_84P COMMON
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
C523 .047UF
16V 10% X7R 0402 COMMON
GND
2/2
2/2
FBVDDQ
USED ONLY FOR 1GB DEVICES ---->
IN IN
R510 1K
1% 0402 COMMON
OUT
R508 1K
1% 0402 COMMON
GND
FBVDDQ
R519 120
5% 0402 NS
FBACLK0
IN
R515 100
R518 120
5% 0402 NS
GND GND
15 25 9 8
1 3 2 0 24 22 21 23 19 20 17 16 14
10 18 7
11
FBACLK0
16
FBAD16
17
FBAD17
18
FBAD18
19
FBAD19
20
FBAD20
21
FBAD21
22
FBAD22
23
FBAD23
FBADQM2 FBADQS2 FBADQSN2
24
FBAD24
25
FBAD25
26
FBAD26
27
FBAD27
28
FBAD28
29
FBAD29
30
FBAD30
31
FBAD31
FBADQM3 FBADQS3 FBADQSN3
R512 120
5% 0402 NS
FBACLK0*
COMMON0603
5%
R511 120
5% 0402 NS
H3 H1 F1 H7 G2 F9 H9 G8
F3 F7 E8
C2 D1 D3 B1 C8 B9 D9 D7
B3 B7 A8
K7 K3
M8 M3 M7 N2 N8 N3 N7 P2 P8 P3 M2 P7 R2 R8 R3 R7
K2 K8
K9
A2 E2
U9A
IC_K4N56163QF_84P COMMON
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
U9C
IC_K4N56163QF_84P COMMON
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
L7 L8
L2 L3 L1
J8
2/2
2/2
IN
U9B
IC_K4N56163QF_84P COMMON
RAS CAS WE CS
A<0> A<1> A<2> A<3> A<4> A<5> A<6> A<7> A<8> A<9> A<10> A<11> A<12> NC/A<13> NC/A<14> NC/A<15>
BA<0> BA<1> NC/BA<2>
CKE CLK CLK
ODT
NC NC
FBVDDQ
1/2
A1
VDD
E1
VDD
J9
VDD
M9
VDD
R1
VDD
A9
VDDQ
C1
VDDQ
C3
VDDQ
C7
VDDQ
C9
VDDQ
E9
VDDQ
G1
VDDQ
G3
VDDQ
G7
VDDQ
G9
VDDQ
J1
VDDL
A3
VSS
E3
VSS
J3
VSS
GND
N1
VSS
P9
VSS
A7
VSSQ
B2
VSSQ
B8
VSSQ
D2
VSSQ
D8
VSSQ
E7
VSSQ
F2
VSSQ
F8
VSSQ
H2
VSSQ
H8
VSSQ
J7
VSSL
J2
Vref
GND
C527 .047UF
16V 10% X7R 0402 COMMON
OUT
5x 220pf - 3.2 to 1 2x 0.047uf - 8 to 1 2x 4.7uf - 8 to 1
FBVDDQ
C565 .01UF
25V 10% X7R 0402 COMMON
GND
FBVDDQ
GND
FBVDDQ
GND
FBVDDQ
C557 .1UF
16V 10% X7R 0402 COMMON
GND
FBVDDQ
C583 1UF
6.3V 10% X5R 0402 COMMON
GND
FBVDDQ
C647 1UF
6.3V 10% X5R 0402 COMMON
GND
Place plane decoupling caps near DQS-DQM pairs.
FBVDDQ
FBVDDQ
GND
C734 .01UF
16V 10% X7R 0402 COMMON
GND
C585 .01UF
25V 10% X7R 0402 COMMON
C632 1UF
6.3V 10% X5R 0402 COMMON
C537 .01UF
25V 10% X7R 0402 COMMON
C733 .1UF
16V 10% X7R 0402 COMMON
C709 .1UF
16V 10% X7R 0402 COMMON
FBVDDQ
FBVDDQ
C533 .1UF
16V 10% X7R 0402 COMMON
C773 .1UF
16V 10% X7R 0402 COMMON
C558 .01UF
25V 10% X7R 0402 COMMON
GND
GND
C679 .1UF
16V 10% X7R 0402 COMMON
C775 .01UF
16V 10% X7R 0402 COMMON
FBVDDQ
C772 .01UF
25V 10% X7R 0402 COMMON
C529 .1UF
16V 10% X7R 0402 COMMON
C781 .01UF
25V 10% X7R 0402 COMMON
C582 1UF
6.3V 10% X5R 0402 COMMON
C792 .1UF
16V 10% X7R 0402 COMMON
C512
4.7UF
6.3V 10% X5R 0603 COMMON
C72
4.7UF
6.3V 10% X5R 0603 COMMON
C728
4.7UF
6.3V 10% X5R 0603 COMMON
1
2
3
C561 .01UF
25V 10% X7R 0402 COMMON
C771
C511
4.7UF
.1UF
16V
6.3V
10%
10%
X7R
X5R 0603
0402
COMMON
COMMON
FBVDDQ
C606 .01UF
16V 10% X7R 0402 COMMON
GND
FBVDDQ
C605
C735
.1UF
.1UF
16V
16V
10%
10% X7R
X7R 0402
0402
COMMON
COMMON
GND
GND
4
5
Micro-Star International Co., LTD.
Size Document Number Rev Custom
A B D F H
1
2
3
4
E GC
5
6
Date:
7
MS-V046
FBA MEMOR Y 1s t bank 0..31
Friday, December 02, 2005
www.vinafix.vn
520
Sheet of
8
1
FBA MEMORY 1st bank 32..63
PLACE ALL DISCRETE COMPONENTS AS NEAR AS POSSIBLE TO MEMORY
2
3
4
5
6
7
8
HGFEDCBA
NAME
VREF_A VREF_B
MIN_LINE_WIDTH
12 12
OUT OUT
1
A A
SUBPARTITION BITS ---->
2
B B
3
C C
4
D D
5
A B D F H
1
IN
USED ONLY FOR 1GB DEVICES ---->
FBACMD[25..0]
FBACMD15 FBACMD15
15
FBACMD25 FBACMD25
25
FBACMD9 FBACMD9
9
FBACMD8 FBACMD8
8
FBACMD1 FBACMD1
1
FBACMD3 FBACMD3
3
FBACMD13 FBACMD13
13
FBACMD4 FBACMD4
4
FBACMD5 FBACMD5
5
FBACMD6 FBACMD6
6
FBACLK1
IN
FBACLK1* FBACLK1*
IN
FBACMD21 FBACMD21
21
FBACMD23 FBACMD23
23
FBACMD19 FBACMD19
19
FBACMD20 FBACMD20
20
FBACMD17 FBACMD17
17
FBACMD16 FBACMD16
16
FBACMD14 FBACMD14
14
FBACMD10 FBACMD10
10
FBACMD18 FBACMD18
18
FBACMD7 FBACMD7
7
FBACMD11 FBACMD11
11
FBA_ODT FBA_ODT
IN
FBAD[63..0]
BI
FBADQM[7..0]
IN
FBADQS[7..0]
IN
FBADQSN[7..0]
IN
2
U12C
IC_K4N56163QF_84P COMMON
1/2
K7
RAS
L7
CAS
K3
WE
L8
CS
M8
A<0>
M3
A<1>
M7
A<2>
N2
A<3>
N8
A<4>
N3
A<5>
N7
A<6>
P2
A<7>
P8
A<8>
P3
A<9>
M2
A<10>
P7
A<11>
R2
A<12>
R8
NC/A<13>
R3
NC/A<14>
R7
NC/A<15>
L2
BA<0>
L3
BA<1>
L1
NC/BA<2>
K2
CKE
J8
CLK
K8
CLK
K9
ODT
A2
NC
E2
NC
FBADQM4
4
FBADQM5
5
FBADQM6
6
FBADQM7
7
FBADQS4
4
FBADQS5
5
FBADQS6
6
FBADQS7
7
FBADQSN4
4
FBADQSN5
5
FBADQSN6
6
FBADQSN7
7
FBVDDQ
A1
VDD
E1
VDD
J9
VDD
M9
VDD
R1
VDD
A9
VDDQ
C1
VDDQ
C3
VDDQ
C7
VDDQ
C9
VDDQ
E9
VDDQ
G1
VDDQ
G3
VDDQ
G7
VDDQ
G9
VDDQ
J1
VDDL
A3
VSS
E3
VSS
J3
VSS
GND
N1
VSS
P9
VSS
A7
VSSQ
B2
VSSQ
B8
VSSQ
D2
VSSQ
D8
VSSQ
E7
VSSQ
F2
VSSQ VSSQ VSSQ VSSQ
VSSL
Vref
32 33 34 35 36 37 38 39
FBADQM4 FBADQS4 FBADQSN4
40 41 42 43 44 45 46 47
FBADQM5 FBADQS5 FBADQSN5
3
FBVDDQ
F8 H2 H8
J7
VREF_A VREF_A
J2
GND
FBAD32 FBAD33 FBAD34 FBAD35 FBAD36 FBAD37 FBAD38 FBAD39
FBAD40 FBAD41 FBAD42 FBAD43 FBAD44 FBAD45 FBAD46 FBAD47
C524 .047UF
16V 10% X7R 0402 COMMON
R517 1K
1% 0402 COMMON
D1 C2 D3 D7
D9 C8
H9 H7
G8 H1 G2 H3
B1
B9
B3 B7 A8
F1 F9
F3 F7 E8
R522 1K
1% 0402 COMMON
GND
C
U11C
IC_K4N56163QF_84P COMMON
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
U12A
IC_K4N56163QF_84P COMMON
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
SUBPARTITION BITS ---->
USED ONLY FOR 1GB DEVICES ---->
OUT
2/2
2/2
15 25 9 8
1
3 13 4 5 6
21
23
19
20
17
16
14
10
18
7
11
FBACLK1
IN IN
FBVDDQ
R521 120
5% 0402 NS
FBACLK1
IN
Place the differential termination resistor at the end of the transmission line.
4
R520 120
5% 0402 NS
GND GND
U11B
IC_K4N56163QF_84P COMMON
1/2
K7
RAS
L7
CAS
K3
WE
L8
CS
M8
A<0>
M3
A<1>
M7
A<2>
N2
A<3>
N8
A<4>
N3
A<5>
N7
A<6>
P2
A<7>
P8
A<8>
P3
A<9>
M2
A<10>
P7
A<11>
R2
A<12>
R8
NC/A<13>
R3
NC/A<14>
R7
NC/A<15>
L2
BA<0>
L3
BA<1>
L1
NC/BA<2>
K2
CKE
J8
CLK
K8
CLK
K9
ODT
A2
NC
E2
NC
A
U11A
IC_K4N56163QF_84P COMMON
F1 H1 G2 H3 G8 H7 F9 H9
F3 F7 E8
D1 D7 C2 B1 D3 B9 C8 D9
B3 B7 A8
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
U12B
IC_K4N56163QF_84P COMMON
DQ<0> DQ<1> DQ<2> DQ<3> DQ<4> DQ<5> DQ<6> DQ<7>
DQM DQS DQS
IN
2/2
2/2
FBAD48
48
FBAD49
49
FBAD50
50
FBAD51
51
FBAD52
52
FBAD53
53
FBAD54
54
FBAD55
55
FBADQM6 FBADQS6 FBADQSN6
FBAD56
56
FBAD57
57
FBAD58
58
FBAD59
59
FBAD60
60
FBAD61
61
FBAD62
62
FBAD63
63
FBADQM7 FBADQS7 FBADQSN7
R514 120
5% 0402 NS
R516
0603
FBACLK1*
100
COMMON
5%
R513 120
5% 0402 NS
E GC
5
FBVDDQ
A1
VDD
E1
VDD
J9
VDD
M9
VDD
R1
VDD
A9
VDDQ
C1
VDDQ
C3
VDDQ
C7
VDDQ
C9
VDDQ
E9
VDDQ
G1
VDDQ
G3
VDDQ
G7
VDDQ
G9
VDDQ
J1
VDDL
A3
VSS
E3
VSS
J3
VSS
GND
N1
VSS
P9
VSS
A7
VSSQ
B2
VSSQ
B8
VSSQ
D2
VSSQ
D8
VSSQ
E7
VSSQ
F2
VSSQ
F8
VSSQ
H2
VSSQ
H8
VSSQ
J7
VSSL
J2
Vref
IN
C526 .047UF
16V 10% X7R 0402 COMMON
GND
6
FBVDDQ
FBVDDQ
FBVDDQ
FBVDDQ
FBVDDQ
FBVDDQ
C531 .1UF
16V 10% X7R 0402 COMMON
GND
C584 .01UF
25V 10% X7R 0402 COMMON
GND
C783 1UF
6.3V 10% X5R 0402 COMMON
GND
C555 .1UF
16V 10% X7R 0402 COMMON
GND
C580 .01UF
25V 10% X7R 0402 COMMON
GND
C789 1UF
6.3V 10% X5R 0402 COMMON
GND
C746 .01UF
25V 10% X7R 0402 COMMON
C749 1UF
6.3V 10% X5R 0402 COMMON
16x power/gnd pin pairs per mem 3x 0.022uf - 5.3 to 1 6x 4700uf - 2.7 to 1 5x 220pf - 3.2 to 1 2x 0.047uf - 8 to 1 2x 4.7uf - 8 to 1
C541 .01UF
25V 10% X7R 0402 COMMON
C574 .01UF
25V 10% X7R 0402 COMMON
C540 1UF
6.3V 10% X5R 0402 COMMON
C575 .01UF
25V 10% X7R 0402 COMMON
7
C790 .01UF
25V 10% X7R 0402 COMMON
C553 .1UF
16V 10% X7R 0402 COMMON
C648
C510
.01UF
4.7UF
25V
6.3V
10%
10%
X7R
X5R
0402
0603
COMMON
COMMON
C791 .01UF
25V 10% X7R 0402 COMMON
C545 .01UF
25V 10% X7R 0402 COMMON
C79
C649 .01UF
4.7UF
25V
6.3V
10%
10%
X7R
X5R
0402
0603
COMMON
COMMON
Micro-Star International Co., LTD.
Size Document Number Rev Custom
Date:
MS-V046
FBA MEMOR Y 1s t bank 32..63
Friday, December 02, 2005
Sheet of
8
1
C764
4.7UF
6.3V 10% X5R 0603 COMMON
2
3
C509
4.7UF
6.3V 10% X5R 0603 COMMON
4
5
620
www.vinafix.vn
Loading...