Page 2 MSI-4300 Porta-Weigh Plus/5 Key User Guide
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
MSI-4300 Porta-Weigh Plus/5 Key User Guide Page 3
TABLE OF CONTENTS
Introduction ............................................................4
Specifications ......................................................... 4
Features...................................................................5
Unpacking...............................................................6
Batteries .................................................................. 6
Type.................................................................. 6
Installing/Changing .......................................... 6
Keyboard Operations.............................................. 7
Keyboard Features ........................................... 7
Power Switch.......................................................... 9
Zero Switch ............................................................ 9
Net/Gross switch .................................................. 10
Tare In/Tare Out Switch ....................................... 10
To remove the Tare Value............................... 11
Test Switch ........................................................... 11
Calibration & Setup .............................................. 12
Switch Functions during Calibration & Setup 12
Enabling Calibration and Setup............................ 12
Calibrate Setup Menu ........................................... 13
Standard Calibration ............................................. 13
Fine Calibration .................................................... 14
Cal with Rcal value (Calibrate with the
Resistor Calibration number) ............................... 14
To Enable/Disable AZM (Auto Zero
Maintenance) ........................................................15
To Set the Legal Standard.....................................15
Other Setup Functions ..........................................16
Filter ...............................................................16
Auto Off .........................................................16
Lighting .......................................................... 16
Remote ........................................................... 16
Setpoint .......................................................... 16
Disable Setpoint .............................................18
Contrast ..........................................................19
To Initialize the Scale ...........................................19
Infrared Remote Control Option .......................... 20
Remote Control Battery Replacement.................. 21
Infrared Remote Comments ................................. 22
Proper Loading Procedures ..................................24
The MSI Limited Warranty ..................................25
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 4 MSI-4300 Porta-Weigh Plus/5 Key User Guide
INTRODUCTION
The Measurement Systems International Porta-Weigh Plus Crane Scale represents a new level of technology and performance in the scale industry. A16 bit microcontroller coupled with an alphanumeric display gives unprec­edented versatility and programmability. Advanced power saving circuitry provides in excess of 2000 hours of operating time from ordinary “D” cell alkaline batteries. The large, backlit alphanumeric display provides precise, unambiguous indication of operating modes such as Net and Gross. Digital calibration simplifies scale maintenance. The single circuit board, fully shock­mounted and marine-proof construction makes for a rugged and reliable overhead scale.
6 Digit Weight Indication
8
Character Message Display
Units
lb, kg, t, METRIC t
International Motion Icon
Motion Indicator
Center of Zero Icon
Low Battery Indicator
METRIC
AUTOREMOTE
0
MOTION
+
-
"Infrared Remote On" Indicator
"Auto-Total On" Indicator
Minus Sign
SPECIFICATIONS
Accuracy: Class III or IIIL Operating Temperature:
14° F to 95° F (-10° C to +35° C) Operating
-40° F to +176° F (-40° C to +80° C) Storage
Enclosure: NEMA IV, Alodined cast aluminum Safe Overload: 200% of rated capacity Capacities - pounds (kilograms):
500 (250) 1000 (500) 2000 (1000) 5000 (2500) 10,000 (5000) 20,000 (10,000) 30,000 (15,000) 50,000 (25,000) 70,000 (35,000) 100,000 (50,000)
Other capacities available by special order or as dictated by standards compli­ance. MSI has designed and manufactured crane scales up to 500 ton capacity. Ultimate Overload:
500% of rated capacity except:
Backlit, transflective LCD provides excellent readability from full sunlight to total darkness. The alphanumeric section prompts the operator through setup and calibration.
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
MSI-4300 Porta-Weigh Plus/5 Key User Guide Page 5
25,000 kg unit is 490% of rated capacity 35,000 kg unit is 430% of rated capacity 70,000 lb unit is 475% of rated capacity 50,000 kg unit is 450% of rated capacity
FEATURES
• Designed to meet or exceed all USA, Canadian, United Kingdom, and International standards.
• Rugged construction throughout. Single printed circuit board is shock mounted to withstand shocks in excess of 50 G’s. Switches are totally sealed and rated for over 10 million operations.
• Precise high resolution 20 bit A/D conversion coupled with advanced 16 bit microcontroller provides world class features and accuracy.
• Six 1.65 inch high (42 mm) digits for clear weight readings from a distance.
• Easy to read annunciation of measurement modes such as NET or GROSS are provided on eight .825 inch (20.9 mm) alphanumeric characters. Also used for menu prompts.
• Display illumination uses rugged, long life, electroluminescent backlighting coupled with a transflective liquid crystal display providing optimum display contrast under all ambient conditions from full sunlight to total darkness. Operation is light-sensing automatic or manually set.
• Exceptional battery life: Typically 2000 hours of continuous use provided by 8 alkaline “D” cell batteries. Maximum battery life is reduced by use of the backlighting; full time low light operation will provide up to 300 hours of operation. A typical operating cycle of 8 hours daylight use and 2 hours night use will provide 10 months of operation on a single battery change. The Porta-Weigh Plus will automatically power down when not in use (this feature can be disabled). A low battery indication appears when approxi­mately 10% of battery life remains.
• Easy to maintain: Full digital calibration assures reliable, repeatable measure­ments.
• Complete marine sealing ensures reliable operations under harsh weather conditions.
• Anti-EMI shielding is standard. Low emissions and susceptibility.
• Easily customized for special applications.
• IR Remote control is available as an option. Adds keyboard tare and other features.
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 6 MSI-4300 Porta-Weigh Plus/5 Key User Guide
UNPACKING
When unpacking the scale from the shipping container, insure that all parts are accounted for. Check the scale for any visible damage and immediately report any damage to your shipper. It is advisable to use the original shipping con­tainer when shipping or transporting the Port-A-Weigh.
BATTERIES
Type
8 Standard “D” cells. Alkaline type is preferred, but standard Carbon-Zinc can also be used. This reduces the available battery life in half. Also Ni-Cad “D” cells work fine. Ni-Cad battery life varies widely, but should be about one quarter the equivalent of Alkaline.
Installing/Changing
1) The batteries must have enough charge to ensure accurate operation. If the batteries are too low, the scale will automatically shut off (8 batteries in series must total more than 5.4 V).
2) Turn the Porta-Weigh Plus off.
3) Remove the battery tubes by turning the knobs counterclockwise. It is not necessary to remove both tubes at once.
4) Replace the batteries with four fresh “D” cells in each tube.
5) Reinstall the battery tubes by inserting the tubes back into the unit and turning the knobs clockwise.
Note: The batteries can be checked with the Test Mode. Power displayed is in relative percent (%) of battery life. If the number with fresh batteries is extremely low (less than 10%), turn off the power, remove the tubes and check that the polarity of all the batteries is correct.
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
MSI-4300 Porta-Weigh Plus/5 Key User Guide Page 7
KEYBOARD OPERATIONS
T
0
ZERO NET/GROSS TAREPOWER TEST
IN / OUT
1 2 3 4 5
1) POWER
Push to turn the scale on or off.
2) ZERO
Used to zero the scale. Zero range depends on standard.
3) NET/GROSS
When in NET mode, pushing this provides a temporary (4 seconds) gross weight reading.
4) TARE IN/OUT
When in GROSS mode, pushing TARE will zero any weight on the scale which causes the scale to go into the NET mode. When in NET mode, pushing TARE will clear the TARE value and the scale will revert to the GROSS mode.
5) TEST
When pushed, this causes a display segment check, and provides battery and RCAL tests.
Keyboard Features
Silicon elastomeric rubber switches provide up to 10 million operations. Far more rugged than mechanical switches that can withstand excessive impact without affecting operation.
Rubber membrane provides watertight and salt spray-proof seal. Addi­tional poly shield on underlay provides second layer of integrity and prevents humidity contamination.
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 8 MSI-4300 Porta-Weigh Plus/5 Key User Guide
This page intentionally left blank.
Loading...
+ 20 hidden pages