MSA Safety 815179, 489353, 464046, 464032, 816662 User Manual

...
Comfo® Twin-Cartridge Respirators
Protection against a variety of respiratory hazards
Because every life has a purpose...
MSA Comfo Twin-Cartridge Respirators provide protection against a variety of respiratory hazards. The respirators use chemical cartridges, aerosol lters, or a combination of the two, to remove specic contaminants from the inhaled air. The cartridges are interchangeable among all MSA Comfo Twin-Cartridge Respirators and are constructed of high-strength metal.
The respirators are available in a half-mask facepiece version (Comfo Classic®) and two full-facepiece styles (Ultra-Twin® and Ultra Elite®). In addition, with the Twin-Cartridge Adapter, the user can convert any demand-style Ultravue® or Ultra Elite Full-Facepiece into a twin-cartridge respirator.
All MSA Comfo Twin-Cartridge Facepieces are available in hycar rubber or silicone, which has a unique sealing surface designed to reduce facepiece slippage. All are formulated to maximize comfort and minimize the possibility of skin irritation, yet are resistant to chemicals and facial oils. They all come in small, medium and large sizes.
Parts can be quickly connected and
disassembled for ease of maintenance.
Applications
Applications for MSA Comfo Twin-Cartridge Respirators include welding, smelting, construction and hazardous waste remediation, as well as others in the chemical, oil and gas, marine, and pulp and paper industries. These comfortable respirators are ideal for both intermittent and extended exposure situations.
Limitations
As an air-purifying device, all MSA twin-cartridge respirators must not be used in atmospheres containing less than 19.5 percent oxygen, or in atmospheres immediately dangerous to life and health (IDLH).
Twin-cartridge respirators must not be worn for protection against gases or vapors with poor warning properties.
Twin-cartridge respirators must not be used in atmospheres containing more than 100 times the exposure limit for the contaminant present.
MSA Comfo Twin-Cartridge Respirators
www.MSAsafety.com
3
See page 5 for threaded Comfo cartridges and lters.
Small Medium Large
COMFO CLASSIC
RESPIRATOR
808075 808074 808076 Comfo Classic Facepiece,
SoftFeel hycar
808072 808071 808073 Comfo Classic Facepiece,
SoftFeel silicone
Comfo Classic Half-Mask Respirator
SoftFeel rubber and Silicone facepieces enhance softness, increasing wearer comfort
Face seal design provides secure, comfortable t
Ultra-Twin Full-Facepiece Respirator
Feature an inturned lip, large chin cup, and 5 headstraps with roller buckles for secure, comfortable t
Wide polycarbonate lens is coated for scratch and chemical resistance
Speaking diaphragm provides clear communications
Nosecup reduces lens fogging
See page 5 for threaded Comfo lters and cartridges.
Small Medium Large
ULTRATWIN
FACEPIECES
471298 471286 471310 Ultra-Twin Facepiece, hycar
480263 480259 480267 Ultra-Twin Facepiece, silicone
Comfo Respirator Cartridges
Users can choose from a complete line of cartridges that protect against a wide variety of contaminants. Filter cartridges protect against dusts, particles and mists. Chemical cartridges protect against gases and vapors. Combination cartridges deliver protection from both particulate and gaseous contaminants.
The GME and GME-P100 Cartridges from MSA are designed to be used for any applications where GMA, GMB, GMC, or GMD cartridges are currently being used.
The GME-P100 Cartridge is NIOSH-approved for 16 specic compounds including gases, vapors, toxic dusts and mists.
The GME Cartridge provides protection from 10 specic gases and vapors. Adding a prelter to the GME adds protection against paints, pesticides, dusts, mists and fumes.
Designed for easy installation, Comfo Cartridges thread directly to the cartridge receptacles on Comfo and other twin­cartridge respirators. All cartridges are interchangeable and are color-coded to indicate the type of protection oered.
The cartridges are made of metal, which allows for easy detection of damage. The cartridge holders securely retain the screw-in cartridges and resist damage from impact, corrosion and most chemicals. The color of each cartridge indicates the type of protection for which it is approved.
The complete Comfo line of particulate, chemical and combination cartridges is approved under 42 CFR Part 84.
Ultra Elite/Ultravue Twin-Cartridge Respirators
Ultra Elite Facepiece
State-of-the-art mask provides excellent comfort and protection
Distortion-free lens allows wide eld-of-view
5-point harness allows easy on/o
Models include Hycar rubber and silicone versions
Unique airow prevents lens fogging
Ultravue Facepiece
5-point harness allows easy on/o
Models include Hycar rubber and silicone versions
See page 5 for threaded Comfo lters and cartridges. Note: Ultra Elite and Ultravue Facepieces must be tted with a Twin-Cartridge Adapter P/N 803622 to be used as a twin-cartridge respirator.
TWINCARTRIDGE
ADAPTER
803622 Twin-Cartridge Adapter, converts any demand
Ultra Elite or Ultravue Facepiece to a twin-cartridge respirator
Small Medium Large
ULTRA ELITE FACEPIECES
with twin-cartridge adapter
10016758 10016759 10016770 Ultra Elite Facepiece,
SoftFeel hycar
10016755 10016756 10016757 Ultra Elite Facepiece,
SoftFeel silicone
ULTRA ELITE FACEPIECES
less twin-cartridge adapter
493064 493020 493108 Ultra Elite Facepiece,
SoftFeel hycar
493072 493928 493116 Ultra Elite Facepiece,
SoftFeel silicone
ULTRAVUE FACEPIECES
less twin-cartridge adapter
471218 457126 471230 Ultravue Facepiece,
hycar
480251 480247 480255 Ultravue Facepiece,
silicone
Ultra Elite Facepiece, shown with Twin-Cartridge Adapter and Comfo P100 Cartridges
Ultravue Facepiece, shown without Twin-Cartridge Adapter or cartridges
MSA Comfo Twin-Cartridge Respirators
www.MSAsafety.com
5
Comfo Respirator Cartridges
Acid Gases
The Comfo line of particulate, chemical and combination cartridges is NIOSH-certied (to 42 CFR, Part 84). Cartridges t Comfo Classic, Ultra-Twin, Ultra Elite Twin-Cartridge and Duo-Twin Respirators, and certain half-mask and full-face Advantage Respirators with Adapter (P/N 809999).
Organic Vapor
Chlorine
Sulfur Dioxide
Chlorine
Dioxide
Hydrogen
Chloride
Hydrogen
Sulde
Ammonia
Methylamine
Formaldehyde
Hydrogen
Fluoride
Mercury Vapor
Filter Type & Eciency
See
Denitions
below
MSA Cartridge
Description
Re-Order Part Number
Color Coding
OV CL SD CD HC HS AM MA FM HF MV P100 R95 N95
See
Notes
below
Organic Vapor (GMA) 464031 (10 in pkg.) 2,3,5
Organic Vapor/P100 (GMA) 815178 (6 in pkg.) 2,3,4
Organic Vapor/P100 Short Stack (GMA) 815186 (6 in box) 2,3,4
Acid Gas (GMB) 464032 (10 in box) 2,5
Acid Gas/P100 (GMB) 815179 (6 in box) 2,4
Organic Vapor/Acid Gas (GMC) 464046 (10 in pkg.) 2,3,5
Organic Vapor/Acid Gas/P100 (GMC) 815180 (6 in box) 2,3,4
Organic Vapor/Acid Gas/P100 Short Stack (GMC) 815188 (6 in box) 2,3,4
Ammonia/Methylamine (GMD) 464033 (10 in box) 2,3,5
Ammonia/Methylamine/P100 (GMD) 815181 (6 in box) 2,3,4
Multigas (GME) 492790 (10 in box) 2,3,5
Multigas/P100 (GME) 815182 (6 in box) 2,3,4
Iodine Vapor/P100 (GMI)* 815184 (6 in box) 2,4
Chlorine/Mercury Vapor/P100 (Mersorb) 815185 (6 in box) 2,4
P100 815175 (10 in box) 1,4
Sparkfoe® P100 815176 (10 in box) 1,4
Low-Profile P100 815177 (10 in box) 1,4
Stand-alone and cover
N95 and covers required
for Comfo Respirators
816662 N95 (10 in pkg.) 816661 N95 (50 in box) 489353 Reusable snap-on cover (1 in pkg.; 2 req.)
1
Prefilter and Cover N95
816662 N95 (10 in pkg.) 816661 N95 (50 in pkg.) 489353 Reusable snap-on cover (1 in pkg.; 2 req.)
1
Prefilter and Cover R95
816287 R95 (20 in box) 489219 R95 Reusable snap-on cover (1 in pkg.; 2 req.)
1
* Ef fec tive against, but not NIOSH- ap proved for Io dine Va por.
Definitions
N95-Par tic u late Filter (95% filter efficiency level)
effective against particulate aerosols free of oil; time use restrictions may apply.
R95-Par tic u late Filter (95% filter efficiency level)
effective against all par tic u late aerosols; time use restrictions may apply.
P100-Par tic u late Filter (99.97% filter efficiency level)
effective against all par tic u late aerosols.
Notes
1. Do not use in atmospheres containing less than 19.5 percent oxygen, in atmospheres containing gases or vapors or in at mo spheres immediately dan ger ous to life and health.
2. Do not use in atmospheres containing less than 19.5 percent oxygen, or in at mo spheres im me di ate ly dan ger ous to life and health.
3. Do not wear for protection against organic vapors with poor warning properties or those which generate high heats of reaction with the sorbent material in the cartridge.
4. 99.97 percent efficient against 0.3 micron DOP.
5. Both a prefilter and cover must be used with the cartridge in order to obtain R95 or N95 particulate protection.
An appropriate cartridge change-out schedule must be developed by a qualified professional, unless the cartridge/canister utilizes an end-of-service-life indicator. The change-out schedule must take into account all factors that may influence respiratory protection including specific work practices and other conditions unique to the worker’s environment. If using against substances having poor warning properties, there is no secondary means of knowing when to replace the cartridges/canister. In such cases, take appropriate additional precautions to prevent overexposure, which may include a more conservative change-out schedule or using an air-supplied respirator or SCBA. Failure to follow this warning can result in serious personal injury or death. As a reference, below is a partial list of substances having poor warning properties:
Acrolein Hydrogen cyanide Nitric acid Phosphorus trichloride Aniline Hydrogen selenide Nitro compounds Stibine Arsine Methanol Nitrogen oxides Sulfur chloride Bromine Methyl bromide Nitroglycerin Urethane or other diisocyanate­Carbon monoxide Methyl chloride Nitromethane
containing paints
Diisocyanates Methylene chloride Phosgene Vinyl chloride Dimethyl sulfate Nickel carbonyl Phosphine
Carrying Pouch
Belt-mounted carrying pouch with Velcro closures.
Nosecup to Reduce Fogging
Molded from a soft rubber compound that is resistant to facial oils, the optional nosecup helps reduce the possibility of lens fogging. The nosecup is particularly eective under con di tions of high humidity and/or low temperatures by inhibiting contact of moist ex ha la tion with the facepiece lens. A nosecup can be easily axed to the facepiece without tools, and any size nosecup may be installed in any size MSA facepiece, resulting in a cus tom ized facepiece for more comfortable use.
MSA Condence Plus® Germicidal Cleaner
Mix with warm water for a germicidal cleaner that is eective against various micro-organisms including immunodeciency virus Type 1 (HIV-1, associated with AIDS). EPA-approved for use on safety equipment.
Personal Safety Equipment Towelettes
Provides an excellent method for wiping and refreshing respirators, hard hats and other safety equipment between full cleaning periods.
Cover Lens for Full Facepiece Respirators
Lens covers protect the facepiece lens from scratches during storage, handling and use. The self-adhesive covers can be easily installed and removed when necessary. Tinted versions are intended for applications in direct sunlight.
Spectacle Kits for Full Facepiece Respirators
For use by workers who must wear corrective lenses, the Spectacle Kit can be easily inserted into the facepiece. The kit includes a wire support, rubber guide and pair of metal-frame spectacles. Desired adjustment is obtained by moving the spectacles in and out of the rubber guide and up and down the wire support. One size of spectacle frame is used (S-7 shape, 44-mm lens size) with Universal Bridge Corrective Lenses that can be obtained from local sources. The Spectacle Kit can be used in conjunction with a nosecup. There are two kits for the Ultra Elite facepiece; one uses a side wire support to hold the lenses in the facepiece while the other uses a center support to position the unit (spectacle adjustments are similar).
CARRYING
POUCH
468730 Carrying pouch for Comfo half-mask
respirators
817040 Carrying pouch for Comfo full facepiece
respirators
NOSECUP 813138 Ultravue/Ultra-Twin, black, small
813139 Ultravue/Ultra-Twin, black, medium
813140 Ultravue/Ultra-Twin, black, large
CONFIDENCE
PLUS CLEANER
10009971 MSA Condence Plus Germicidal Cleaner,
32 oz bottle
TOWELETTES 697382 Canister with 220 towelettes
697383 Box of 100 individually wrapped towelettes
SPECTACLE
KITS
804638 Ultra Elite Spectacle Kit (side wire support)
493581 Ultra Elite Spectacle Kit (center support)
454819 Ultravue/Ultra-Twin Facepiece Spectacle Kit
COVER LENS 491500 Cover lens for Ultra Elite, clear, 25/pkg
805456 Cover lens for Ultra Elite, smoke tint, 25/pkg
456975 Cover lens for Ultravue, clear, 25/pkg
480326 Cover lens for Ultravue, smoke tint, 25/pkg
Twin-Cartridge Respirator Accessories
Welder’s Adapter
For eye protection in welding applications where respiratory protection is required, a welder’s adapter can be installed easily over an Ultravue Facepiece lens. The clip-on style adapter can be easily removed as necessary, whereas the integral adapter model is used in place of the facepiece lens. Both models are made of polycarbonate and feature a ip-up lens with large 4 1/2" x 5 1/4" (11.4 cm x 13.3 cm) vision area.
WELDER’S
ADAPTER
AND
FILTER PLATES
472859 Clip-On Welder’s Adapter for Ultravue and
Ultra Twin Facepieces; with cover lens, less lter plate
806482 Clip-On Welder’s Adapter for Ultra Elite
Facepiece; with cover lens, less lter plate
38347 Rayfoe Filter Plate, shade 10, heat-treated,
4-1/2 x 5-1/4
38277 Rayfoe Filter Plate, shade 12, heat-treated,
4-1/2 x 5-1/4
696095 Cover Lens
486328 Welder’s Hood, Kevlar
www.MSAsafety.com
7
QuikChek™ II Adapter
The QuikChek II Fit Test Adapter allows quantitative t testing of any Comfo Classic, Duo-Twin or Ultra-Twin Respirator.
Qualitative Fit Test Kits
The Occupational Safety and health Administration (OSHA) requires t tests to ensure proper t for workers who use respirators. The Qualitative Fit Test Kits allows you to qualitatively check the t of MSA respirators. NOTE: Qualitative testing methods rely on objective data to determine a proper t, are subjective in nature and rely on the judgment of the test subject.
Bitrex and Saccharin Qualitative Fit Test Kits
Both the Bitrex and Saccharin Qualitative Fit-Test Kits contain everything needed to implement a qualitative respirator t-test program in accordance with OSHA requirements. The kits include a test hood, two nebulizer bulbs, t-test solution, sensitivity solution and two sets of replacement nebulizer inserts. Also included is a 10-minute instructional DVD.
Banana Oil Fit Test Kit
MSA’s Banana Oil Fit-Test Kit relies on a test subject’s ability to detect a 95% pure solution of Isoamyl Acetate (banana oil).
Probed Respirator Facepieces for Fit Testing
All Models Available
To make it easy for you to perform quan ti ta tive t tests, MSA oers a full line of specially-modied facepiece assemblies. Each probed facepiece is equipped with a built-in probe assembly, sampling line, and a clothing clip to hold the sampling line. The probes are made of solid brass. In all MSA half-facepiece models, the probe is attached to the body of the res pi ra tor. Full-facepiece respirators are probed through the lens and sealed with a neoprene washer and brass ttings.
MSA also oers probed lenses for use with existing Ultravue facepieces. These lenses come completely assembled with the same brass probe, sealing hardware, and sampling line as the probed full­facepieces. All respirators use standard MSA high-eciency lters for tests.
Cradle Conversion Kit
For simple, snap-on replacement of elastic headstraps with a cradle headband and/or neckstrap.
Comfo Cartridge Adapter for Advantage® Respirators
This adapter allows for the use of threaded Comfo Cartridges on the Advantage 200 LS or 420 Half-mask Respirator or Advantage 2000, 3000, or 4000 Full-face Respirator.
MSA
RESPIRATOR
FIT TEST KITS
697287 Saccharin Qualitative Fit Test Kit
697444 Bitrex Qualitative Fit Test Kit
697285 Replacement (Saccharin) Sensitivity Test
697445 Solution, 55 ml bottle (Bitrex)
697286 Replacement Fit-Test (Saccharin) Solution,
55 ml bottle
697446 Replacement Fit-Test (Bitrex) Solution,
55 ml bottle
697447 #1 Sensitivity Nebulizer
697459 #2 Fit-Test Nebulizer
697448 Test Hood (Same for Both)
697325 “Using the Qualitative (Saccharin) Fit Test
Kit” DVD
697449 “Using the Qualitative (Bitrex) Fit Test Kit”
DVD
801628 Banana Oil Qualitative Fit Test Kit
QUIKCHECK II
ADAPTER
812022 QuikChek II Fit Test Adapter
803196 Replacement Kit with 25 feet of
sampling tubing and 25 connectors, clips and suction cups
Small Medium Large
COMFO CLASSIC 808253 808247 808259
ULTRATWIN 471683 465457 471684
ULTRAVUE 471681 465425 471682
ULTRA ELITE 813210 813208 813212
Hycar Rubber Facepieces
Small Medium Large
COMFO CLASSIC 808258 808252 808264
ULTRATWIN 482025 482024 482026
ULTRAVUE 482009 482008 482010
ULTRA ELITE 813211 813209 813213
Silicone Facepieces
CRADLE
CONVERSION KIT
479875 Cradle headband only
ADVANTAGE
ADAPTER
809999 Advantage adapter
for threaded cartridges
www.MSAsafety.com
Note: This Bulletin contains only a general description of the products shown. While uses and performance capabilities are described, under no circumstances shall the products be used by untrained or unqualified individuals and not until the product instructions including any warnings or cautions provided have been thoroughly read and understood. Only they contain the complete and detailed information concerning proper use and care of these products.
ID 10-00-03-MC / Dec 2013
© MSA 2013 Printed in U.S.A.
MSA Corporate Center
1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Phone 724-776-8600
www.MSAsafety.com
U.S. Customer Service Center
Phone 1-800-MSA-2222 Fax 1-800-967-0398
MSA Canada
Phone 1-800-672-2222 Fax 1-800-967-0398
MSA Mexico
Phone 01 800 672 7222 Fax 52 - 44 2227 3943
MSA International
Phone 724-776-8626 Toll Free 1-800-672-7777 Fax 724-741-1559
Offices and representatives worldwide
For further information:
Twin-Cartridge Respirator Accessories
Training Aids
MSA oers DVD training aids on the proper care, use and main tenance of MSA Twin-Cartridge Respirators.
MSA Response® Guide
Available at www.MSAsafety.com/responseguide
Has chemical database with exposure limit, respirator type selector, and gas detectors
Has a cartridge service life calculator
Has information on managing a respiratory protection program
TRAINING AIDS 697282 Proper Care and Use
of the Comfo Classic Respirator
696820 Proper Care and Use
of the Ultra-Twin Respirator
MSA-U® Training Center
MSA‐U is a feature‐rich online training center that oers courses anytime, anywhere to maximize the users’ competencies on MSA products, product technologies, and safety industry standards.
Benets
Complete training, anytime, anywhere
Easy course navigation
Link to 'New' Training from the home page
Select certicates achieved, from the home page
From the home page, view courses you accessed
Immediate feedback on test performance
Detailed training reports available for managers
Receive feedback on incorrect test answers
www.msasafety.com/msau
www.msasafety.com/msau
Loading...