
WE KNOW YOU’RE TIRED OF...
“HAVING TO PULL SO MUCH WIRE AT EVERY
GAS DETECTOR INSTALLATION...”
“NEEDING TO DISCONNECT POWER
BEFORE CHANGING A SENSOR”
“REMEMBERING HOW TO
CALIBRATE THIS THING”
“WONDERING IF THE GAS DETECTOR
IS WORKING”
“LOSING MY MAGNET...
I HAVE BIGGER THINGS
TO WORRY ABOUT”
YOU HAVEN’T BEEN ABLE
TO DO ANYTHING ABOUT IT...
UNTIL NOW.

ALL NEW DESIGN
BLUETOOTH®
CONNECTION STATUS
ACTIVE
OPERATION
INDICATOR
INSTRUMENT STATUS INDICATORS
GAS READING
GAUGE AND
PROGRESS BAR
BRIGHT
STATUS LED
Power Fault Alarm
STAY CONNECTED.
WORK SMARTER.
• Bluetooth wireless technology
• Check status and get alerts up to 75 ft. (23 m) away
• Modify settings/setpoints/alarms
• Initiate calibration and view progress
• Reduce setup time by at least 50%
MSAsafety.com/detection

ADVANCING SENSOR TECHNOLOGY
Up to 2 YEARS between calibrations!
MSA Industry Average
Longer Sensor Life
5 years
O
2 years
Toxic
Comb.
5 years
2.5 years
5 years
3.5 years
Longer Warranties
3 years
1 year
Higher Temperature
+ 60°C
+ 50°C
10x Better Resolution for HS & SO
0.1 ppm
1 ppm
* Data may vary for dierent gases and congurations

RE-CALIBRATE YOUR EXPECTATIONS
TECHNOLOGY
Adaptive Environmental Compensation (AEC)
Longer Sensor Life Longer Calibration Cycles Better Stability (Lower Drift)
Automatically self-checks 4x/day
SPEAKER &
SPEAKER PORT
UNOBSTRUCTED
SENSOR OPENING
24 months
4.5 months
MSA Industry Average
Diusion Supervision (DS)
XCELL
SENSOR
XCELL
SENSOR
MSA
Industry Average50%
(% Original Output)
Months
MEASUREMENT
MICROPHONE
BLOCKED SENSOR
OPENING
Diusion Supervision warns if the sensor inlet becomes blocked and unable to detect gas. It employs a proprietary acoustic
mechanical design and algorithms to measure sound across the sensor’s inlet. If the inlet is blocked with a material, like ice, the
dierence in the sound is detected and the unit is put into fault. When the obstruction is removed, Diusion Supervision detects the
clearance and returns to normal operation. H
calibration cycles of 24 months reducing maintenance costs and allowing resources to be utilized elsewhere!
S and CO Sensors congured with Diusion Supervision technology allow extended
2
MSAsafety.com/detection

2” (50.8 mm) integral
pipe mount bracket
DO MORE WITH LESS
SIMPLE RETROFITS
Identical footprint and wiring
as ULTIMA X Series
3/4” (19 mm) NPT
or M25 threads
Dual sensors and
analog outputs
Touch interface
for tool-free operation
Dual sensing capability for any
combination of sensors
Tag attachment
Multilingual text
menu options
Combustible, toxic,
or oxygen digital sensors
POWERED BY
WITH
TECHNOLOGY
Safely and quickly replace sensors
without turning o the instrument

IT MAKES SENSE... NO EXCEPTIONS
EXPECTED LIFE WARRANTY PATENTS
We’re going to help you save*
Installation
Annual
maintenance
Over the life
of the product
Request a Cost of Ownership comparison.
30% ~$7,000
50% ~$1,500
75% ~$15k
Questions about sensor placement?
MSA’s gas and ame mapping service combines 160 years
of gas detection experience with 3D technology to help you
maximize the eectiveness of every sensor.
Check out the link or scan for more information:
MSAsafety.com/gas-mapping
* Based on 10 sensors and 2 sensors/transmitter
MSAsafety.com/detection

ULTIMA X5000 Gas Monitor
Specications
Product Specications
COMBUSTIBLE GAS
SENSOR TYPE
TOXIC GAS
& OXYGEN
SENSOR TYPE
Catalytic Bead (XCell combustible)
Infrared (XIR Plus)
XIR PLUS Carbon Dioxide (CO)
XCell Toxic Ammonia (NH
),
3
Carbon Monoxide (CO),
Carbon Monoxide (CO) H-resistant,
INPUT POWER 11 to 30 VDC, 3 wire, <5 W nominal
SIGNAL OUTPUT Dual 4-20 mA current source, HART
BLUETOOTH
OPTIONAL
RELAY RATINGS 5 A @ 30 VDC; 5 A @ 220 VAC
Hydrogen Sulde (HS),
Chlorine (Cl), Sulfur Dioxide (SO)
XCell O Oxygen (O)
Electrochem. Ammonia (NH
), Hydrogen (H2),
3
Hydrogen Chloride (HCl),
RELAY MODES Common, discrete, horn
NORMAL MAX
POWER
Hydrogen Cyanide (HCN),
Nitric Oxide (NO),
SENSOR
MEASURING
RANGES
Nitrogen Dioxide (NO
Sulfur Dioxide (SO
Combustible 0-100% LEL
CO 0-2%, 0-5% Vol
CO 0-100, 0-500, 0-1000 ppm
),
2
)
2
CO, H-resistant 0-100 ppm
Cl 0-5, 0-10, 0-20 ppm
H 0-1000 ppm
HCl 0-50 ppm
EMC DIRECTIVE Complies with EN 50270, EN 61000-6-4,
HCN 0-50 ppm
HS 0-10, 0-50, 0-100, 0-500 ppm
NH
0-100, 0-1000 ppm
3
NO 0-100 ppm
DISPLAY Organic LED (multi-lingual) with contrast ratio of
HART HART 7, HART device description language available
NO 0-10 ppm
TYPICAL SENSOR
LIFE
APPROVALS
CLASSIFICATION
DIVISIONS US/CAN
ZONES GLOBAL
O 0-25%
SO 0-25, 0-100 ppm
XCell Sensors 5 years
Infrared 10 years
Markings vary by component.
See manual for specic component markings.
Class I, II, III; Div 1 & 2, T4/T5/T6
Ex db nA IIC T5 Gb (Class I, Zone 1/Zone2)
FAULT S
MONITORED
CABLE
REQUIREMENTS
Ex tb IIIC T85°C Db (Class II, Zone 21)
ENCLOSURE RATING
Type 4X, IP66
WARRANTY X5000 transmitter 2 years
XIR PLUS 10 years source,
5 years electronics
XCell Sensors 3 years
Electrochemical Sensors Varies by gas
APPROVALS CSA, FM*, ATEX, IECEx, INMETRO, DNV-GL Marine,
CE Marking.
Complies with C22.2 No. 152, FM 6320
RED, FCC, Suitable for SIL 2
Environmental Specications**
OPERATING
TEMPERATURE
STORAGE
** May dier by gas type, see data sheet
XCell -40°C to +60°C
RANGE
XIR PLUS -40°C to +60°C
-40°C to +60°C
TEMPERATURE
RANGE
RELATIVE HUMIDITY
NONCONDENSING
XCell toxics & O 10-95%
XCell combustible 0-95%
* See manual for FM approved sensors.
XIR PLUS 15-95%
Note: This Bulletin contains only a general description of the products shown. While product uses and performance capabilities
are generally described, the products shall not, under any circumstances, be used by untrained or unqualied individuals. The
products shall not be used until the product instructions/user manual, which contains detailed information concerning the proper
use and care of the products, including any warnings or cautions, have been thoroughly read and understood. Specications are
subject to change without prior notice.
0720-175-MC / 03.2021
© MSA 2021
Mechanical Specications
Bluetooth Low Energy (BLE) v4.3 or higher
(3X) SPDT - fault, warn, alarm
Relays Relays
Without With
XIR PLUS 5.7 W 6.7 W
XCell combustible 3.9 W 4.9 W
XCell Toxic & O 1.8 W 2.8 W
XIR PLUS & XCell combustible 9.9 W 10.9 W
XIR PLUS & XCell toxic or O 6.0 W 7.0 W
Dual XIR PLUS 10.6 W 11.6 W
Dual XCell toxic & O 2.6 W 3.6 W
Dual XCell combustible 9.6 W 10.6 W
Dual XCell comb. & XCell toxic or O 4.3 W 5.3 W
EN 61000-6-3
2000:1 and view angle of 160°
Low supply voltage, RAM checksum error, ash
checksum error, EEPROM error, internal circuit error,
relay, invalid sensor conguration, sensor faults, general
system
3-wire shielded cable for single sensor and 4-wire
shielded cable for dual sensor congurations.
Accommodates up to 12 AWG or 4 mm2
Refer to manual for mounting distances.
Dimensions
MSA operates in over 40 countries
worldwide. To nd an MSA oce near you,
please visit MSAsafety.com/oces.
MSAsafety.com/detection