Advantage® 200 LS, 420
and 3200 Respirators
Advantage 200 LS Half-Mask Respirator
Comfortable Fit and Balance
Mask can be adjusted to the wearer for a
pressure points throughout the day.
Swept back cartridge design helps to provide
stability and weight distribution on the face.
Lower Total Cost of Ownership
The Advantage 200LS keeps replacement, and
maintenance costs down by only having 4 main
components.
1. Facepiece blank
2. 4-point yoke
3. Inhalation/exhalation valves
4. Head harness
4
3
1
2
Advantage 420 Half-Mask Respirator
Simplicity, Comfort and Flexibility
An important characteristic of the Advantage 420
is user-friendliness.
The innovative patent-pending single loop head
harness outshines the competition. It grants the
user an intuitional operation and oers high
comfort and exibility. The unique one-piece
over-molded silicone nose cup is soft and
pleasant to wear and extremely robust.
Advantage 3200 Full-Facepiece Respirator
Comfortable Fit and Balance
The Advantage 3200 design includes a nosecup, to help
reduce fogging in low temps or high humidity, so that
you are able to focus on the task at hand.
The wrap around scratch-resistant face piece
high-impact performance requirements.
Reduce Respirator Downtime
All components of the Advantage 3200 can be replaced
without special tools - for quick maintenance and limited
downtime of your respirator.
Advantage 200 LS, 420 and 3200 Respirators
Advantage® Respirator Cartridges
+
The Advantage® line of particulate, chemical
and combination cartridges provides
Advantage 420 and 3000 Full-Facepiece
Advantage® Respirators.
MSA Cartridge
Description
A2 430371 2,3
A2 P3 430372
A2 B2 E1 K1 430373
A2 B2 E1 K1 P3
Low-Prole P3
P2 Snap-On
Re-Order Part
Number
430374
430375
10011347
Pack of 20 + Covers
Colour
Coding
Brown
Brown
Mustard
Mustard
White
A2 Acid Gases B2E1 K1
Organic Vapour
Chloride
Sulfur Diodixe
Chloride Dioxide
Hydrogen
Chloride
OV CL SD CD HC HS* AM MA FM HF MV P100
Brown
White
Mustard
White
White
Ammonia
Methylamine
Formaldehyde
Hydrogen
Fluoride
Mercury Vapor
P3 P2
See
Notes
Below
2,3,4
2,3,4
2,3
1,4
D
particulate aerosols free of oil; time use restrictions may apply. (P1)
against all particulate aerosols. (P2)
* Escape only. + Only with Full Facepiece
Notes 1. Do not use in atmospheres containing less than 19.5 percent oxygen, in atmospheres
containing gases or vapors or in atmospheres immediately dangerous to life and health.
2. Do not use in atmospheres containing less than 19.5 percent oxygen, or in atmospheres
immediately dangerous to life and health.
3. Do not wear for protection against organic vapors with poor warning properties or
those which generate high heats of reaction with the sorbent material in the cartridge.
4.
+ P3 with Full Facemask only.
An appropriate cartridge change-out schedule must be developed by a quali ed professional, unless the cartridge/ canister utilizes an
end-of-service-life indicator. The change-out schedule must take into account all factors that may inuence respiratory protection including
specic work practices and other conditions unique to the worker’s environment. If using against substances having poor warning properties,
there is no secondary means of knowing when to replace the cartridges/canister. In such cases, take appropriate additional precautions to prevent
overexposure, which may include a more conservative change-out schedule or using an air-supplied respirator or SCBA. Failure to follow this
warning can result in serious personal injury or death. As a reference, below is a partial list of substances having poor warning properties:
Acrolein
Aniline
Arsine
Bromine
Carbon monoxide
Diisocyanates
Dimethyl sulfate
Hydrogen cyanide
Hydrogen selenide
Methanol
Methyl bromide
Methyl chloride
Methylene chloride
Nickel carbonyl
Nitric acid
Nitro compounds
Nitrogen oxides
Nitroglycerin
Nitromethane
Phosgene
Phosphine
Phosphorus trichloride
Stibine
Sulfur chloride
Urethane or other diisocyanatecontaining paints
Vinyl chloride
MSAsafety.com