MRV TERESCOPE TS700/100, TS700/155, TS700/G, TS800/155, TereScope700 User Manual

...
Page 1
TereScope700 and TereScope800
Wireless Optical Communication Links
Models TS700/100, TS700/155, TS700/G, TS800/155
Page 2
WIRELESS OPTICAL COMMUNICATIONS
User Manual
Document Number ML48237 (4703700), Rev. 4.0
February 2006
MRV Communications, Inc.
Web site: www. mrv.com
Page 3
MRV Communications, Inc. – Installation Manual
Table of Contents
STANDARDS
Standards Compliance ............................................................................i
FCC Notice ...............................................................................................i
CE Mark ...................................................................................................i
Other Standards .....................................................................................ii
MRVTM Laser Safety Certification........................................................ii
ABOUT THIS USER MANUAL
Audience .................................................................................................iii
Qualifications ......................................................................................... iii
Training .................................................................................................. iii
Experience .............................................................................................. iii
Authorization .........................................................................................iii
SAFETY REQUIREMENTS
Before Installing ....................................................................................iv
Before Powering On ..............................................................................iv
When Installing ......................................................................................iv
Servicing .................................................................................................. v
INTRODUCTION ...............................................................................vi
CHAPTER 1 - THE PRODUCT
Models.......................................................................................................1
General Description ................................................................................ 2
Front.........................................................................................................2
Back ..........................................................................................................3
A. TS700/155 (Standard Model)............................................................3
B. TS800/155 (Standard Model)............................................................5
C. TS800/155-F (Standard Model including Fusion option)..............8
D. TS700/100 (Fast Ethernet)..............................................................11
E. TS700/G (Gigabit Ethernet)............................................................13
Monitoring & Management Options...................................................15
Typical Connection................................................................................16
CHAPTER 2 - SITE SURVEY
Line of Sight........................................................................................... 17
Orientation.............................................................................................17
Location & Range.................................................................................. 17
Mounting Environment & Stability.....................................................20
Transmitting through a Window.........................................................22
CHAPTER 3 - INFRASTRUCTURE
Power......................................................................................................24
Page 4
MRV Communications, Inc. – Installation Manual
Data/Signal Cabling .............................................................................. 24
For TS700/155, TS700/G, TS800/155, TS800/155-F............................24
For TS700/100.........................................................................................25
CHAPTER 4 - BENCH TEST
TS700/155, TS800/155, and TS800/155-F............................................ 26
TS700/100............................................................................................... 27
TS100/G..................................................................................................28
Display and Results...............................................................................29
TS700/155, TS800/155, and TS800/155-F............................................ 29
TS700/100............................................................................................... 30
TS700/G..................................................................................................30
CHAPTER 5 - INSTALLATION
Accessories .............................................................................................31
Mounting................................................................................................34
TS Detachement from the JMP-L ..............................................34
Mounting the Accessories............................................................35
Special Mounting.........................................................................36
Attachment of the Transceiver (TereScope Head) ...................38
CHAPTER 6 - AIMING PROCEDURE
Powering on the TereScope ..................................................................39
Transceiver Alignment..........................................................................40
Coarse Alignment.........................................................................40
Fine Alignment.............................................................................41
Link Operating Test..............................................................................44
Installation Log......................................................................................44
Installation Completion ........................................................................ 44
CHAPTER 7 - MAINTENANCE
Periodic Visits........................................................................................40
APPENDIX A: Product specifications AP PE NDIX B: Digital Readout vs. Distance AP PE ND IX C: Unpacking Instructions for TereScope AP PE N DIX D: Tool Kit, Equipment, and Materials AP PE ND IX E: TereScope Bench Test Procedure AP PE N D IX F: Effect of wi nd on TereScopes APPENDIX G: FSO Chaining AP PE NDI X H: Installation Log APPENDIX I: Power over Ethernet
Page 5
MRV Communications, Inc. – Installation Manual
i
Standards
Standards Compliance
UL 1950; CSA 22.2 No 950; FCC Part 15 Class B; CE-89/336/EEC, 73/23/EEC
FCC Notice
WARNING: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in the manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct for the interference at the user’s own expense. The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user’s authority to operate this equipment.
It is suggested that the user use only shielded and grounded cables when appropriate to ensure compliance with FCC Rules.
CE Mark
The CE mark symbolizes compliance with the EMC directive of the European Community. Such marking is indicative that the specified equipment meets or exceeds the following technical stand ard s:
EN 55022 - Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment
EN 50081-1- Electromagnetic compatibility - of Radio Interference Characteristics of Information Technology Equipment Generic Emission standard Part 1 – Residential commercial and light industry environment
EN 50082-1 - Electromagnetic compatibility -- Generic immunity standard Part 1: Residential, commercial and light industry environment
EN61000-4-2 (previously IEC 1000-4-2) - Electromagnetic compatibility for industrial­process measurement and control equipment Part 4: Section 2 - Electrostatic discharge requirements
EN61000-4-3 (previously IEC 1000-4-3) - Electromagnetic compatibility for industrial­process measurement and control equipment Part 4: Section 3 - Radiated electromagnetic field requirements
EN61000-4-4 (previously IEC 1000-4-4) - Electromagnetic compatibility for industrial­process measurement and control equipment Part 4: Section 4 - Electrical fast transient/burst requirements
EN61000-4-5 - Electromagnetic compatibility for industrial-process measurement and control equipment Part 4: Section 5 – Surge Immunity requirements
EN61000-4-6 - Electromagnetic compatibility for industrial-process measurement and control equipment Part 4: Section 6 – Immunity to conducted disturbances induces by radio frequency fields
EN61000-4-8- Electromagnetic compatibility for industrial-process measurement and control equipment Part 4: Section 8– Power frequency magnetic field immunity requirements
EN61000-4-11 – Electromagnetic compatibility for industrial-process measurement and control equipment Part 4: Section 11 – Voltage dips short interruptions and voltage variations immunity requirements
EN61000-3-2 – Harmonic standard
EN61000-3-3 – Voltage Fluctuation and Flicker standard
CISPR 22 - Radiated and Line-conducted Class B
EN 60950 - ITE Safety
Page 6
MRV Communications, Inc. – Installation Manual
ii
Other Standards
1. CISPR 22: 1993 AS/NZS 3548: 1995, Class B Joint Amendment No. 1: 1997, Joint Amendment No. 2: 1997
2. EN 60950+A1+A2+A3+A4+A11 ACA TS001-1997 AS/NZS 3260: 1993 A4: 1997
3. ITU G.703, G.704, G.706,G.736, G.737, G.738, G739, G740, G.775, G.823.
MRV  Laser Safety Certification
The TereScope is designed, built, and tested to be eyesafe, even if the output beams are viewed directly, provided that no magnifying optics are used. This product is Class 1M according to the American National Standard for Safe Use of Lasers, A N SI Z136.1-1993, provided that there is not a reasonable probability of accidental viewing with optics in the direct path of the beam where the TereScope is installed. This product is Class 1M according to the Int ernat ional Standard of the International Electrotechnical Commision IEC 60825-1, Amendment 2, January 2001 entitled “Safety of laser products.” The following explanatory label is applicable to these products:
LASER RADIATION
DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS
(BINOCULARS OR TELESCOPES)
CLASS 1M LASER PRODUCT
This product complies with United States FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 50 as published in June, 2001, which allows for the use of the IEC 60825-1 classification standard. Under this standard, these products are Class 1M. A ‘Declaration of Conformity’, in accordance with the above standards, has been made and is on file at MRV.
Disclaimer
MRV
reserves the right to modify the equipment at any time and in any way it sees fit in order to improve it.
MRV provides this document without any warrant y of any kind, either expressed or implied, including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose.
The customer is advised to exercise due discretion in the use of the contents of this document since the customer bears sole responsibility.
Trademarks
All trademarks are the property of their respective holders.
Copyright © 2004 by MRV
All rights reserved. No part of this document may be reproduced without the prior permission of MRV. This document and the information contained herein are proprietary to M RV and are furnished to the recipient solely for use in operating, maintaining and repairing M RV
equipment. The information within may not be utilized for any purpose except as stated herein, and may not be disclosed to third parties without written permission from MRV. MRV
reserves the right to make changes to any technical
specifications in order to improve reliability, function, or design.
Page 7
MRV Communications, Inc. – Installation Manual
iii
About this User Manual
Audience
This manual is intended for the user who wishes to install, operate, manage and troubleshoot the TereScope700 and TereScope800.
Qualifications
Users of this guide are expected to have:
Working knowledge of Electro-optical equipment
Working knowledge of LAN equipment (Layer 2 and 3)
A License to install equipment on buildings/elevated structures
A License to work with power line (mains) voltages 110/230 Vac
Training
Installers are required to do a training course on MRV TereScopes that includes:
IR links (site survey, installation equipment, alignment, etc.)
Indoors and outdoors installation
On-the-job-training
Proficiency tests
Experience
Installers are required to have experience in coax cable TV home pass installation, PTT home pass installation, LAN installation, IR equipment installation, and home electrical wiring.
Authorization
After all the requirements specified above (namely, Qualifications, Training, and Experience) have been met, the installer must receive authorization from MRV certifying eligibility.
Page 8
MRV Communications, Inc. – Installation Manual
iv
Safety Requirements
All requirements stipulated in the safety laws of the country of installation must be abided by when installing the TereScopes.
Caution!
In addition, ensure that the requirements noted in this chapter are met in order to reduce risk of electrical shock and fire and to maintain proper operation.
Before Installing
Power: Ensure that all power to the TereScope is cut off. Specifically,
disconnect all TereScope power cords from the power line (mains).
Inspection: Ensure by inspection that no part is damaged.
Before Powering On
Line Power: Ensure that the power from the line (mains) is as specified on
the TereScope.
Power Cord: The power cord of The TereScope must have the following
specifications: Flexible 3-conductor power cord approved by the cognizant safety organization of the country. The power cord must be Type HAR (harmonized), with individual conductor wire having cross-sectional area 0.75 sq. mm. min. The power cord terminations should be a suitably rated earthing-type plug at one end and 3 terminal cord forks for M3 screws (1 for each wire) at the other end. Both of the power cord terminations must carry the certification label of the cognizant safety organization of the country.
When Installing
Ensure, by visual inspection, that no part of the TereScope is damaged.
Avoid eye contact with the laser beam at all times.
Ensure that the system is installed in accordance with ANSI Z136.1
control measures (engineering, administrative, and procedural controls).
Ensure that the system is installed in accordance with applicable
building and installations codes.
Install the TereScope in a restricted location as defined in this manual
since it is a Class 1M FSOCS transmitter and receiver. A restricted location is a location where access to the transmission equipment and exposed beam is restricted and not accessible to the general public or
Figure A: 3 terminal cord
forks
Page 9
MRV Communications, Inc. – Installation Manual
v
casual passersby. Examples of restricted locations are: sides of buildings at sufficient heights, restricted rooftops, and telephone poles. This definition of a restricted location is in accordance with the proposed IEC 60825-I Part 12 requirements.
Avoid using controls, adjustments, or procedures other than those
specified herein as they may result in hazardous radiation exposure.
Avoid prolonged eye contact with the laser beam (maximum 10 sec.).
Servicing
All servicing must be carried out only by qualified service personnel. Before servicing, ensure that all power to the TereScope is cut off!
Page 10
MRV Communications, Inc. – Installation Manual
vi
Introduction
CAREFULLY READ THE ENTIRE MANUAL BEFORE INSTALLING
n InfraRed (IR) link allows connection without any cable between two distant sites. For that, two identical transceivers, each installed on one site and aligned to face each other, provide point-to-point connectivity. This
configuration makes possible data transfer from one terminal to the other through the air over an optical wavelength carrier, the IR link – see picture in Figure B, below.
Figure B: IR Link
The installation of such a link can be summarized as 4 stages:
Site survey
Installation of the infrastructure
Mounting of the equipment
Aiming (alignment) procedure
Always use appropriate safety equipment and procedures when working with electrical equipment and when working on roofs
.
A
!
!!
!
Page 11
MRV Communications, Inc. – Installation Manual
1
The Product
Caution!
When handling the TereScope, take special care not to damage the polycarbonate window!
Models
Table 1: Models of the TereScope1
Models
Part Number
Description
TS700/100 TS100/A/FET/VS TereScope700 for Fast Ethernet
100Base-TX connectivity up to a distance of 360 m + Power-over-Ethernet option.
TS700/155 TS155/A/YUW/VS TereScope700 for 1-155 Mbps
connectivity up to a distance of 360 m.
TS700/G TS1000/A/YUW/VS TereScope700 for Gigabit Ethernet and
FiberChannel (1.0625) connectivity up to a distance of 400 m
TS800/155 TS155/C2/YUW/VS TereScope800 for 1-155 Mbps
connectivity up to a distance of 550 m + Fusion option.
Using the Part Number for Ordering
To place an order for a TereScope model having a specific configuration, use the Part Number format shown in Table 1, noting the following:
‘155’ represents link operation speed in the range 1 to 155 Mbps. ‘A’ represents TereScope700. ‘C2’ represents TereScope800. ‘Y’ represents Optical Fiber Mode. Instead of Y use one of the following:
M (for MultiMode)
1
TereScope700 or TereScope800.
Chapter
1
Page 12
MRV Communications, Inc. – Installation Manual
2
S (for SingleMode) ‘U’ represents operating wavelength. Instead of U use one of the following:
8 (for 850 nm)
3 (for 1310 nm)
5 (for 1550 nm) ‘W’ represents connector type. Instead of W use one of the following:
C (for SC)
T (for ST) ‘FET’ (Fast ethernet) represents 100Base-TX with RJ45 connector ‘V’ represents existence/absence of Fusion. Instead of V use one of the following:
V designates no built-in Fusion option.
F designates built-in Fusion option (only in TS800). ‘S’ represents power supply type. Instead of S use one of the following:
S (for input to the power supply in the range 100-240 VAC)
3 (for input to the power supply in the range 24-60 VDC)
Examples
1 - TS155/A/M3C/VS means TS700/155 :1-155Mbps link, Multimode, 1310 nm, SC interface, 100-240 VAC power supply.
2 - TS155/C2/S3T/F3 : TS800/155 :1-155Mbps link, Singlemode, 1310 nm, ST interface, built-in Fusion option, 24-60 VDC power supply.
General Description and explanations
1. Front
Each TereScope head comprises a receiver, 1 transmitter and an interface on the rear panel for connection to the peripheral equipment see Figure 1.1.
Figure 1.1: Front View
Front view Showing the receiver side, the transmitters and the telescope
Telescope
Transmitter
Receiver
CAUTION!
AVOID EXPOSURE – INVISIBLE LASER RADIATION IS EMITTED FROM THIS APERTURE
Page 13
MRV Communications, Inc. – Installation Manual
3
HIGH
VOLT.
LOW
VOLT.
MRV
Switch
Ip
Address
Fast
Etherne t
Position
Data Rate
UP
Norma l
DOWN
Local Loopback
1 23
Mode of
Defau l t IP
ATM
OC3
E3 T3
4,5
4
5
Norma l
Align ment
-
4,5
-
4
5
TX RX
TELESCOPE
TORQUE VALUE 7 Lb-Inch
L G N
+/~ -/~
USE COPPER CONDUCTORS ONLY
POWER
OPTICAL POWER
SYNC
FLAG
FIBER OPTIC
NOT IN
USE
MANAGEMENT
1762310-SC
SYNC
FLAG
AIR RX
F/O RX
G
2. Back
All models of the TereScope are SNMP manageable. SNMP monitoring can be performed using MRV’s MegaVision SNMP management application.
A. TS700/155 (Standard Model)
The TS700 supports Fast Ethernet, OC3, STM1, E3, and T3 protocols in the 34­155 Mbps range. A special type of TS700 can be ordered that can be used for
Open Protocol applications which ensures complete transparency (including all data in the range of 1-155 Mbps.) In this type, less than 2 dB of the budget is
lost.
Figure 1.2b: Rear View of TS700/155
Main Data: SC or ST Connector
DIP Switch Toggles 6,7,8 positions are not used.
Figure 1.2a: TS700/155 Standard Model Panel Schematic
If you need to install the SNMP card into the TereScope, after installing the card and before closing the back panel, carefully punch out this piece of metal.
Page 14
MRV Communications, Inc. – Installation Manual
4
Back Panel Description
Table 2: TS700/155 Standard Model Back Panel Controls, Interfaces, and Indicators
Air RX Flag LED
Green LED indicates data received by the Airlink
receiver. Turns ON at the threshold level.
Air RX Sync LED Yellow LED. Turns ON if the rate of the received
Data matches the Data Rate set on the Data Rate DIP switch.
F/O RX Flag LED Green LED indicates Data received by the Fiber
Optic receiver. Turns ON at the threshold level.
F/O RX Sync LED Yellow LED. Turns ON if the rate of the received
Data matches the Data Rate set on the Data Rate DIP switch.
Indicators (7-segment display, LEDs)
Optical Power 7­segment display
Digital readout indicates the Optical Power level received by the Airlink receiver.
Alignment Telescope
For fine alignment.
Connectors
Power
Power source Termina l Block (Main or UPS) AC power supply (100 to 240 Vac) or DC power supply (24 to 60 Vdc)
Fiber optic
Fiber Optic interface for connection to the peripheral equipment. The standard interface is MM 1310nm SC connector; other interfaces are available upon request.
Management
(Optional)
Connection to 10base-T SNMP management interface. (To be ordered separately)
Mode of Operation
(Toggles 1 and 2)
Set the Operating Mode ALIGNMENT = Idle transmitted automatica lly NORMAL = Signal received through the F/O port is transmitted through the Airlink TX. Signal received through the Airlink RX is transmitted through the F/O TX. LOOPBACK=The Data received by the F/O RX is directly returned through the F/O TX.
IP address set up
(for Mgt. option)
(Toggle 3)
Used only with the management option. Whe n the Switch toggle is on OFF position, the TereScope’s IP address is the default one (shown on the back panel label: 10.0.0.101). To set a new IP address please refer to the “IP address setting procedure for TereScope management c ard” file in the Manuals CD. The new IP address is valid only after the TereScope is powered off and on.
Selectors (DIP Switch Toggles)
--
shown in Figure
1.3
Data Rate
(
Toggles 4 and 5)
Set the transmission rate of the transc eiver (internal clock).
- Fast Ethernet: 4,5 OFF
- ATM/OC3/STM1:155 Mbps: 4,5 ON
- E3: 34.368 Mbps: 5 OFF, 4 ON
- T3: 44.736 Mbps: 4 OFF, 5 ON
Page 15
MRV Communications, Inc. – Installation Manual
5
B. TS800/155 Standard Model
The TS800/155 supports most of the prevalent protocols in the 34-155 Mbps range. Support for a special protocol, which is not on the list, can be ordered after coordination with the factory. This model can be used for Open Protocol
applications which ensures complete transparency (including all data in the range of 1-155 Mbps.) In this case, a maximum 2 dB of the power budget is lost.
Back Panel Description
Table 3: TS800/155 Standard Model Back Panel Controls, Interfaces, and Indicators
Power
Power source Termina l Block (Main or UPS). AC power supply (100 to 240 Vac) or DC power supply (24 to 60 Vdc)
Fiber optic
Fiber Optic interface for connection to the peripheral equipment. The standard interface is MM 1310nm SC connector; other interfaces are available upon request. In model TS800/155-F with the fusion option, there are two fiberoptic interface ports for connection to the Fusion system; one primary and the other redundant.
Remote monitor Connection to the RSM. (The RSM has to be
ordered separately)
Connectors
Management
Connection to 10Base-T SNMP mana gement interface.
Pins 1,2: TX and 3,6 RX. Pins (4,5) and (7,8) of this connector can be used for dry contact purposes, for Airlink flag and F/O fla
g
alarms respectivel
y
Figure 1.3: TS800/155 Standard Model Panel Schematic
Page 16
MRV Communications, Inc. – Installation Manual
6
Note:
Pins (4,5) and (7,8) of the management RJ45 connector can be used for dry
contact purposes, for Airlink flag and F/O flag alarms r espectively.
Selectors (DIP Switch DS1 Toggles)
-- shown in Figure 1.3and
1.4
Data Rate (Toggles 1,2,3,4)
Set the transmission rate of the transc eiver (internal clock).
- Fast Ethernet: 1,2,3,4 OFF
- ATM/OC3/STM1:155 Mbps: 2,3,4 OFF, 1 ON
- SMPTE 143 Mbps: 3,4 OFF, 1,2 ON
- E3: 34.368 Mbps1,2,4 OFF, 3 ON
- T3: 44.736 Mbps: 2,4 OFF, 1,3 ON
- OC1/STM0: 51.840 Mbps: 1,4 OFF, 2,3 ON
- Customized 1 : 4 OFF, 1,2,3 ON
- Customized 2 : 1,3,4 OFF, 2 ON
- Open Protocol: 1,2,3 OFF, 4 ON.
Mode Select (Toggles 1, 2, 3)
Set the Operating Mode ALIGNMENT = Idle transmitted automatica lly NORMAL = Signal received via the F/O port is transmitted through the Airlink TX. Signal received via the Airlink RX is transmitted through the F/O TX. LOOPBACK= Data received by the F/O RX is directly returned through the F/O TX. REMOTE LOOP = Loops the electrical RX to the electrical TX and optical RX to the optical TX of the remote unit. ATTENUATION: The alignment signal is attenuated (~20db) when the DIP switch toggle #3 is moved to ON position.(to use when the installation distance is less than 200m only for alignment mode). Switch back to OFF position for normal mode.
Laser Power Off (Toggle 4)
Turning off laser TX when the DIP switch toggle is moved to ON
Fusion (Toggle 5)
This switch toggle enables working with MRV’s Fusion system (Built-in fusion option or switch option). For additional information, see page 7. Switch toggle 5 OFF: Fusion not Active (Disabled) Switch toggle 5 ON: Fusion active (Enabled).
Window Heater (Optional) (Toggle 6)
Used only with the heating option (To be spe cified in the PO). Switch toggle 6 OFF: The heater is disabled Switch toggle 5 ON: The heater is enabled.
IP address set up (Toggle 7)
When the Switch toggle is on OFF position, the TereScope’s IP address is the default one (shown on the back panel label: 10.0.0.101). To set a new IP address please refer to the “IP addre ss setting procedure for TereScope management card ” f ile in the Manuals CD. The new IP address is valid only after the TereSc ope is powered off and on.
Selectors (DIP Switch DS2 Toggles)
-- shown in Figure 1.3 and
1.4
Control Mode (Toggle 8)
When the Dip Switch toggle #8 is on OFF position, the TereScope is in the HARDWARE mode, i.e. the TereScope is controlled only by the TereScope itself by means of the switches on its back panel. When the Dip Switch toggle is on ON position, the TereScope is in the SOFTWARE mode i.e. the TereScope is controlled by the management Software and vari ous functions can be activa ted by means of this management Software.
Page 17
MRV Communications, Inc. – Installation Manual
7
Air RX Flag LED
Green LED indicates data received by the Airlink
receiver. Turns ON at the threshold level.
Air RX Sync LED Yellow LED. Turns ON if the rate of the received
Data matches the Data Rate set on the Data Rate DIP switch.
F/O Main, RX Flag LED
Upper green LED indicates Data received by the Fiber Optic receiver. Turns ON at the threshold level.
F/O Main, RX Sync LED
Lower green LED. Turns ON if the rate of the received Data matches the Data Rate set on the Data Rate
DIP switch.
F/O Redundant, RX Flag LED (Optional)
Upper green LED indicates Data received by the Fiber Optic receiver. Turns ON at the threshold level.
F/O Redundant, RX Sync LED (Optional)
Lower green LED. Turns ON if the Fusion is active and there is sy nchronisation with the received Data
.
Optical Power 7­segment display
Digital readout indicates the Optical Power level received by the Airlink receiver.
Alignment LED Yellow LED. Turns ON if the Alignment
Operating Mode is selected.
Loopback LED Yellow LED. Turns ON in LOOPBACK mode.
Flashing in Remote Loop mode.
Fusion LED Yellow LED. Turns ON if the Fusion mode is
enabled. Flashing when the Fusion (radio back-up system) is active.
SW Mode LED Red LED. Turns ON if the SW Mode
(SOFTWARE) Operating Mode is selected.
Laser Status Shining Red LED: Turns ON when the Laser is
ON and turns OFF when the laser is powered off by pushing the DS toggle #4 ON.
Management TX Flashing when the RSM-SNMP is connected and
the TereScope is transmitting manage ment Data. (There is no Link indication)
Indicators (7-segment display and LEDs)
Management RX Flashing when the RSM-SNMP is connected and
the TereScope is receiving management Data. (There is no Link indication)
Alignment Telescope
For fine alignment.
Page 18
MRV Communications, Inc. – Installation Manual
8
C. TS800/155-F (Standard Model including Fusion option)
This special TS800/155-F model can be connected to the back-up radio system without a special MRV switch and card supporting Fusion. This TereScope can be connected to any switch (supporting 10/100 Mbps data rate) via a standard converter that should be connected to the optical port of the TereScope labeled “Redundant”, while the back-up radio system is connected to the same Switch.
As an alternative, the TereScope can be directly connected to a Media Converter of type 10/100 TX-100 FX (for example, MRV’s media converter MC102F). When the TereScope stops operating, the connectivity from the main optical module to the air channel stops and starts flowing into the second optical module designated for radio.
Figure 1.4: TS800/155-F Standard Model Panel Schematic
Page 19
MRV Communications, Inc. – Installation Manual
9
That’s what happens when the air channel is interrupted.
F/O
Network
RF T
ransceiver
10/100TX-100FX Media Converter
Switch
10/100 Base-T
MC
10 Base-T
STP
F/O
Main
TS
TS
IR = 100 Mbps
Network
Main
RF T
ransceiver
RF = 2-10 Mbps
F/O
F/O
10 Base-T
STP
Redundant
Redundant
Figure 1.5a: TereScope800/155 F - & Fusion System Connection
For a description of the Back Panel and all the functions, see Paragraph B table 3, and Paragraph C Figure 1.4 – TS800 with Fusion model, page 8.
Fusion Operation Mode
When at least one of the air channels (IR) is cut for more than one second or drops to approximately 60 mV at the display readout:
1. TereScope switches to Fusion mode
2. Data is transmitted from Main module to Redundant module without passing through the air channel
3. The signal is converted to 10Base-T by the Switch and the data Rate decreases to 2-10 Mbps
The system switches back to IR channel (TereScope) only when the display readout on both sides increases to approximately 150 mV.
Note: To activate the Fusion option, set DIP Switch toggle 5 to the ON position.
Page 20
MRV Communications, Inc. – Installation Manual
10
Fusion
Maximizing Link Availability in All Weather Conditions.
The TereScope Fusion was designed to combine the best features of two transport mediums, laser light and radio waves, to form a single, seamless, wireless communication link between network devices. By leveraging both technologies, we can provide the 99.999% availability that your network requires.
The TereScope Fusion has been specifically constructed to maximize link availability between network nodes. These systems use the internationally unlicensed, 2.4 GHz ISM band and are used as a backup for a number of TereScope systems.
TereScope Fusion systems have an optical wireless link that provides Fast Ethernet connectivity as the primary link and Ethernet RF as the backup link. These systems operate in most weather conditions, including heavy rain, snow, and fog with nearly 100% link availability. Ease of installation and freedom from licensing make these systems very simple to deploy.
Protocol: 10Base-T (IEEE 802.1 1 b) Frequency: 2.4 - 2.4835 GHz
ISM band (ETSI, FCC
2.4 – 2.497 GHz (Japan) Output Power: -4 to 24 dBm Sensitivity: -85 dBm Operating Power: 110/220 VAC, 500/250 mA Interface: Shielded RJ45
Specifications are subject to change at any time without notice.
Figure 1.5b: TS & Fusion
Page 21
MRV Communications, Inc. – Installation Manual
11
D. TS700/100 - Fast-Ethernet System
Figure 1.6: TS700/100 Model Back Panel
Back Panel Description
Table 4: TS700/100 Back Panel Controls, Interfaces, and Indicators
Power
Power source Termina l Block (Main or UPS) AC power supply (100 to 240 Vac) or DC power supply (24 to 60 Vdc).
100Base-TX
Copper interface (RJ 4 5) for STP cables. MDI-X connection (TX: pins 3,6 and RX: pins 1,2). Connection to the periphera l equipment. This connector can be used for Power-over-Ethernet (PoE) but only with the Low Voltage TereScope version (TS100/A/FET/V3). The standard power for PoE is 36-57 Vdc. However, the TS700/100 can operate with 20-60 Vdc. See appendix I.
Management (Optional)
Connection to 10Base-T SNMP mana gement interface. (To be ordered separately)
Connectors
Dry Contacts There are 2 pairs of dry contact indicators available,
one for Air RX Link LED (Pins 1 and 2), and the other for 100BaseT LED (Pins 3 and for). Dry contacts are normally cl osed (25 ohms), and open in an alarm condition
Page 22
MRV Communications, Inc. – Installation Manual
12
Air RX Link LED
Green LED indicates signal received by the Airlink receiver. Turns ON at the threshold level.
Air RX Data LED
Yellow LED blinking indicates Data transfer via the Airlink receiver to the interface.
TP RX Link LED
Green LED indicates Link established at the 100Base-T receiver. Turns ON when connected to peripheral equipment.
TP RX Data LED
Yellow LED blinking indicates Data transfered via the 100Base-TX interface.
Indicators (7-segment display, LEDs)
Optical Power 7­segment display
Digital readout indicates the Optical Power level received by the Airlink receiver.
Alignment Telescope
For fine alignment.
Mode of Operation (Toggles 1, 2)
Set the Operating Mode ALIGNMENT = Idle transmitted automatica lly NORMAL = Signal received through the TP port is transmitted through the Airlink TX. Signal received through the Airlink RX is transmitted through the TP TX. LOOPBACK=The Data received by the TP RX is directly returned through the TP TX
IP address set up (for Mgt. option) (Toggle 3)
Used only with the management option. Whe n the Switch toggle is on OFF position, the TereScope’s IP address is the default one (shown on the back panel label: 10.0.0.101). To set a new IP address please refer to the “IP address setting procedure for TereScope management c ard” file in the Manuals CD. The new IP address is valid only after the TereScope is powered off and on.
Selectors (DIP Switch Toggles)
--
shown in Figure
1.6
Speed (Toggle 4)
Sets the TereScope to Au to-negotiation mode or to forced 100 mode:
OFF :
Auto-negotiation, ON: Forced 100
Page 23
MRV Communications, Inc. – Installation Manual
13
E. TS700/G - Gigabit-Ethernet System
The TereScope 700/G supports Gigabit Ethernet and FiberChannel protocols. The physical design and configuration of the TS700/G is similar to the other members of the series, and its operational principles are essentially the same. However, The TS700/G only offers a duplex fiber interface. The standard is 850nm SC multimode. (850nm ST multimode, 1310nm and 1550nm SC singlemode are available on request).
HIGH
VOLT.
LOW
VOLT.
MRV
Switch
Ip
Address
Not
Used
Data
Rate
4
Gigabit
Ethernet
Default
Attenuated
Normal
IP
Software IP
Fiber
Channel
1.0625
Position
UP
DOWN
1 23
Mode
Transmitte r
TX RX
TELESCOPE
TORQUE VALUE 7 L b-Inch
L G N
+/~ -/~
USE COPPER CONDUCTORS ONLY
POWER
AIR
FLAG
F/O
FLAG
LASER
ENABLED
POWER
OPTICAL POWER
DRY-CONTACT
LASER
ENABLED
FLAG
FIBER OPTIC
MANAGEMENT
1762318-SC
FLAG
AIR RX
F/O RX
G
Figure 1.7: TS700/G Model Back Panel
Table 5: TS700/155 Standard Model Back Panel Controls, Interfaces, and Indicators
Power
Power source Termina l Block (Main or UPS) AC power supply (100 to 240 Vac) or DC power supply (24 to 60 Vdc)
Fiber optic
Fiber Optic interface for connection to the peripheral equipment. The standard interface is MM 850nm SC connector; other interfaces are available upon request.
Management (Standard)
Connection to 10base-T SNMP management interface.
Connectors
Dry Contact There are 4 pairs of dry contact indicators available:
#
Power
#
Air RX Link LED
#
F/O Flag LED
#
Laser Enabled Dry contacts are normally closed (25 ohms), and open in an alarm condition
Page 24
MRV Communications, Inc. – Installation Manual
14
Air RX Flag LED
Green LED indicates signal received by the Airlink
receiver. Turns ON at the threshold level.
Laser Enabled LED Red LED. Turns ON to indicate that laser in
enabled to transmit light.
F/O RX Flag LED Green LED indicates Data received by the Fiber
Optic receiver. Turns ON at the threshold level.
Pins 1,2 Closed (25 ohm) = Internal DC power functional
Open = internal DC voltage not present in circuit
Pins 3,4 Air Rx alarm
Closed (25 ohm) = airlink optical power received above threshold Open = received optical signal below threshold
Pins 5,6 F/O Rx alarm
Closed (25 ohm) = received signal at fiber interface above threshold open = signal received at fiber receiver below threshold
Pins 7,8 Laser Enabled Alarm
Closed (25 ohm) laser is enabled Open = laser is disabled due to malfunction
Indicators (7-segment display, LEDs),Dry Contact Alarms
Optical Power 7­segment display
Digital readout indicates the Optical Power level received by the Airlink receiver.
Alignment Telescope
For fine alignment.
Transmitter Mode (Toggle 1)
ON position (up) for links above 150m distance. OFF position (down) is for under 170m distance
Not Used (Toggle 2)
Not used. (No internal loopback function. For a complete loop test, far-end loopback of airlink data can be performed externally with fiber from Tx to Rx)
IP Address (Toggle 3)
When the Switch toggle is on OFF position, the TereScope’s IP address is the default one (shown on the back panel label: 10.0.0.101). To set a new IP address please refer to the “IP addre ss setting procedure for TereScope management card ” f ile in the Manuals CD. The new IP address is valid only after the TereScope is powered off and on.
Selectors (DIP Switch Toggles)
--
shown in Figure
1.7
Data rate (Toggle 4)
ON position (up) for Gigabit Ethernet, OFF position (down) for 1.0625Gb/s FiberChannel
Page 25
MRV Communications, Inc. – Installation Manual
15
Monitoring and Management options
1 – Management
2 - Dry contact
(Only TS800)
3 – RSM
(Only TS800)
The TS is manageable by using SNMP option. SNMP monitoring can be performed via MegaVision, MRV’s SNMP software.
The TS can be connected to dry contact box (RSM-DC). The RSM-DC is directly attached to TS at "Remote Monitor" connector.
RJ45 Connection f or SMNP Interface
RSM-DC
The TS can be connected t o monitoring unit: RSM. The connection between the TS and the RSM is made with 7 wires twisted cable.
RSM connection
Figure 1.8: SNMP + TS
Figure 1.9: RSM-DC + TS
Figure 1.10: RSM + TS
Page 26
MRV Communications, Inc. – Installation Manual
16
Typical Connection
1 - Fiber Connection
In order to implement a connection, each transceiver must be connected to the peripheral/testing equipment through fiber optic cables. A correct connection is indicated by the display on the back panel of the transceiver (see the section Display and Results pages 29 and 30).
IT IS A CROSS CONNECTION:
TX $$$$RX AND RX $$$$ TX
Peripheral/Testing
Equipment
UWIN
RX
TX
TX RX
Peripheral/Testing
Equipment
UWIN
RX
TX
TXRX
IR link
Figure 1.11: Typical Connection for Models 155 and 155-F
2 - Copper Connection
In order to implement a connection, each transceiver must be connected to the peripheral/testing equipment with an STP cable. A correct connection is indicated by the display on the back panel of the transceiver (see the section Display and Results pages 29).
IR link
Peripheral/Testing
Equipment
UWIN
10BaseT
10BaseT
STP
cable
Peripheral/Testing
Equipment
UWIN
10BaseT
10BaseT
STP
cable
Figure 1.12: Typical Connection for Model TS700/100
Scheme of the Connection to peripheral equipment
Scheme of the Connection to the peripheral equipment
TS
TS
TS
TS
100Base-TX
100Base-TX
100 BaseT
100 BaseT
Page 27
MRV Communications, Inc. – Installation Manual
17
Site Survey
The first step before every installation is to visit the sites to be linked. in order to make sure that the connection is feasible, to find out potential obstacles or difficulties and to decide on the location and mounting points of the transceivers.
Line of Sight
A necessary condition for linking two distant buildings is that the two mounting sites must be within clear sight of each other.
Pay attention to:
%
Growing vegetation and increasing foliage during spring
%
Building sites (cranes movements, etc.)
%
Chimneys (intervening smoke can interrupt the beam from time to time).
Orientation
Direct sunlight can overload the airlink receiver to saturation level. Avoid, as far as possible, the East-West direction for the link.
Note
In case this is not possible, the surrounding buildings could shield the transceiver from the direct sunlight otherwise outages lasting several minutes (depending on the time of the year and the angle of the sun) could occur. The system will fully recover once the sun is out of the receiver field-of-view.
Location & Range
1. The mounting of the transceiver must be very rigid (preventing the installation from twists of even as little as 1 mrad). The key to the required rigidity is to attach the mounting accessories on strong mounting points such as:
- Stiff building structures
- Concrete or reinforced concrete surfaces
Chapter
2
Page 28
MRV Communications, Inc. – Installation Manual
18
Prefer Avoid Pay attention to
Concrete Parapet Structural wall or column
Old constructions Soft material (asphalt, etc.) Non-uniform surfaces Wooden and metal structures
Colored windows Double glazing The proximity of powe
r
radio antennas
For reasons of convenience, it is always preferable to install the units indoors as long as all the required conditions previously described are met and the customer/building owner allows it. However, when windows are present in the beam path, the attenuating factor of the glass must be considered regarding the distance and the required fade margin.
2. Referring to the data in Appendix A: Product Specifications, set and record the distance between the two TereScopes of the link. (You can use any of the following equipment to determine the distance: rangefinder laser binoculars, GPS receiver, maps, etc.)
3. Noting that two TereScope units are required per link, record the quantity of each model of the TereScope required.
4. Record the bearing to the opposite site by compass.
5. Record the number of links to be installed at the site.
6. Note whether additional sheltering is needed for the TereScope, for e.g., against strong winds (120km/h or more)
CONSULT FACTORY IN CASE OF DOUBT !
Figure 2.1 and Figure 2.2 show optimal and acceptable locations for the TereScope links. Notice that in both figures the TereScopes are mounted on rooftop edges and high enough above the ground.
(1)
In case such situations cannot be avoided, special mounting accessories and techniques must be designed and considered (see section Particular Figure Cases\Techniques page 37)
&
&&
&
TereScope mounted at corner of leading edge of structure.
Page 29
MRV Communications, Inc. – Installation Manual
19
Figure 2.1: Optimal Mounting
Figure 2.2: Acceptable Mounting
Figure 2.3 shows an unrecommended TereScope link location because of interference by IR. Notice that the TereScopes are mounted far from the rooftop edges or are too close to the ground.
Figure 2.3: Unrecommended Mounting
TereScope not at edge of roof.
TereScope not at edge of roof.
Beam path p asses too close to ground. Heat rising causes scintillation. Allow 4.5 m (15 ft) between ground and beam path.
Less than 4.5 m (15 ft) between beam path and heat-emitting surface.
Beam path more than
4.5 m (15 ft) above surface to avoid traffic and rising heat.
TereScope at edge of roof so that heat rising from roof surface does not affect beam
Page 30
MRV Communications, Inc. – Installation Manual
20
Figure 2.4 shows an unacceptable TereScope link location because of interference by passing vehicles. Notice that the TereScopes are mounted far from the rooftop edges and not high enough above the ground.
Figure 2.4: Unacceptable Mounting
Mounting Environment & Stability
1. When deciding the mounting location, you should look on the rooftop for vibration sources such as compressors, elevators, motors, and try to avoid them.
2. Photograph the mounting location so as to select the best mounting option. Figure 2.5 shows mounting locations on a rooftop in descending order of preference. Location 1 is the best; location 7 is the worst.
Figure 2.5: Mounting Locations in Order of Preference
Page 31
MRV Communications, Inc. – Installation Manual
21
Note:
If the only option to mount the TereScope is at points 5, 6 or 7, it has to be mounted at least 2 m above the rooftop to avoid roof scintillations and people crossing the link beam (If possible, avoid placing the TereScope on a mast).
3. Avoid surfaces with high reflectivity (e.g., white walls) behind the TereScope so as to reduce interference with the optical signal.
4. Get customer approval for the exact positions where the TereScopes will be mounted. Using paint, mark these positions.
5. Note the height that each TereScope will be above or aside the rooftop.
6. Identify the floor or wall type and dimensions of the location at which it is planned to mount the TereScope.
7. For each TereScope head, select one of the following mounting options2 and record it.
a. Parapet/Ledge Mounting (Figure 2.6) – This is
a standard mounting option that uses only the Plate (JMP).
b. Wall Mounting (Fig. 2.8) – This is a standard
mounting option that uses the Plate (JMP) as well as the two Brackets (JMB).
c. Floor Pedestal Mounting (Figure 2.7) – This is
a non-standard mounting option that uses the Plate (JMP) as well as a Floor Pedestal (e.g., M015C).
d. Wall Pedestal Mounting (Figure 2.9) – This is a
non-standard mounting option that uses the Plate (JMP) as well as a Wall Pedestal (e.g., M054C).
e. Extended Wall Mounting (Figure 2.10) – This is
a non-standard mounting option that uses the Plate (JMP) as well as an Extended Wall (e.g., M062C).
f. Angle Bracket Mounting (Figure 2.11) – This is
a non-standard mounting option that uses the Plate (JMP) as well as an Angle Br acket (e.g., M001).
Figure 2.6: Parapet/Ledge Mounting (using JMP only)
Figure 2.7: Floor Pedestal Mounting (using JMP and MO15C)
2
For more information on these mounting options, refer to
TereScope Installation Guide
(Publication No.
46366).
Page 32
MRV Communications, Inc. – Installation Manual
22
Figure 2.8: Wall Mounting (using JMP and JMB)
Figure 2.9: Wall Pedestal Mounting (using JMP and MO54C)
Figure 2.10: Extended Wall Mounting (using JMP and MO62C)
Figure 2.11: Angle Bracket Mounting (using JMP and M001)
Transmitting through a Window
1. Determine the number of surfaces the beam transits or is reflected from, the reflectivity of each surface, and condensation/precipitation collection areas.
2. Use the data below to determine whether the light beam attenuation is acceptable.
4% attenuation for each surface of light
reflection.
15% attenuation for a double pane window. Attenuation due to tint in windowpane must be
taken into consideration in choosing the right TereScope model. (The % attenuation depends on the tint and must be measured.)
3. Ensure that the angle of incidence3 of the beam striking the windowpane is between 1º and 45º.
Note
On high buildings, for indoor window installation, the user should consider that occasionally the window-cleaning elevator might block the link beam.
2
Angle which the light beam makes with the perpendicular to the windowpane
Page 33
MRV Communications, Inc. – Installation Manual
23
Figure 2.12 shows the arrangement for transmitting through a window
Figure 2.12: Arrangement for transmitting through a window.
Page 34
MRV Communications, Inc. – Installation Manual
24
Infrastructure
The only infrastructure required for operating the transceiv er and linking the sites is Power and Data/Signal connection to the peripheral networking equipment. This must be ready prior to the airlink installation
.
IN OUTDOOR INSTALLATIONS, USE SHIELDED AND WEATHERPROOF MATERIALS (CABLES, INLETS, AND CONNECTORS) COMPLIANT TO THE SAFETY STANDARD IN FORCE.
Power
Source
The power requirement for standard units is 100-240VAC @
50/60Hz - 10W.
Note: Units requiring low Voltage: 24-60 VDC - 10W can be factory set upon request.
It is recommended to use a Surge Suppression System to avoid damage to the equipment when power supply is unstable. Protection should be at least 25,000A.
Cabling
Standard 3-conductor power cords are required. (See Safety
requirements, Page iv)
Data/Signal Cabling
1. For TS700/155 , TS700/G, TS800/155 , TS800/155-F
Type For connecting the Transceiver to the peripheral equipment, a dual­fiber cable is required (one fiber for transmission, the other for reception). The standard recommended cable is MM 62.5/125 µm fiber or SM 9/125 µm for fiber.
Connectors Each fiber should be terminated with the ordered type of connector on the transceiver end (SC, ST).
Optical Fiber testing.
The cabling installer must specify the attenuation of each fiber installed.
Chapter
3
!
!!
!
Page 35
MRV Communications, Inc. – Installation Manual
25
A simple power loss test can inform us about the condition of the fibers. This test consists in measuring (with an optical power meter) the output power at one end of the tested fiber when a fiber source is connected at the other end. If the values are in dBm, the difference between the input power and the output power gives the power attenuation of the fiber (in dB).
Optical Power Meter
dBm
Peripheral
Equipment
or
Optical Source
F/O
TX
Fiber Optic
Cable
In case the above equipment is not available, a simple visual test may be performed to locate and reject badly damaged fibers. Place a light source at one end of the fiber and intermittently block it and observe the light coming out of the other end. (This procedure does not guarantee that a fiber is acceptable)
A standard 62.5µµµµm fiber optic cable is characterized by an attenuation factor of about 3 to 5 dB/km. A loss value of more than 3 dB for runs up to 200m indicates that the fiber may be faulty.
Note
The fiberoptic cables must be installed by a qualified person.
HANDLE THE FIBERS VERY CAREFULLY.
2. For TS700/100
Type For connecting the Transceiver to the peripheral equipment, 2-pair
STP Category 5 cable is required (one pair for transmission, the other for reception). This cable must be a straight one when the peripheral has an MDI-X 100Base-TX interf ace and a Cross one otherwise.
For PoE (Power over Ethernet), 2 more pairs ST P Category 5 cable are required. (Use only for the Low Voltage version: TS100/A/FET/V3)
Connectors The cable should be terminated with an RJ-45 connector at the Transceiver end.
(
!
Figure 3.1: F/O cable test.
Page 36
MRV Communications, Inc. – Installation Manual
26
Bench T est
It is always easier and more convenient to locate a failure and solve a problem in a lab on a bench than on a roof under bad conditions. Accordingly , it is strongly recommended to perform a bench test with all the modules prior to installation in order to check the equipment compatibility and to v alidate the configuration.
See Unpacking Instructions in Appendix C.
1 – TS700/155, TS800/155, and TS800/155-F
Compatibility
Peripheral equipment
Check the operation of the peripheral equipment connected with cables (see Configuration 1 below).
Interfaces
Check the specifications compatibility (type, wavelength, receiver range, output power, data rate) between the TereScope and the peripheral equipment interfaces.
Test equipment
Chose an appropriate Bit Error Rate (BER) tester for checking the physical link quality. A portable one is preferable since it is more convenient for use in the field.
For example: the OC3 port plus SONET and ATM analyser manufactured by Fluke.
A ping test or a file transfer between two workstations - connected to the networking equipment - is useful and easy to do for testing the performance of the whole configuration.
Setup
Data Rate DIP Switch Toggle According to the application in use, set the switch toggles as indicated in the following table: (In TS800/155 and TS800/155-F set the DS1 toggles)
Chapter
4
Page 37
MRV Communications, Inc. – Installation Manual
27
Table 6: DIP Switch Setting for TereScope
TS700/155 TS800/155
Function
OFF ON OFF ON
Fast Ethernet
4,5 – 1,2,3,4 –
ATM/OC3/STM1: 155 Mbps
4,5
2,3,4
1
SMPTE 143 Mbps
– 3,4
1,2
E3:34.368 Mbps 5 4
1,2,4 3
T3:44.736 4 5
2,4 1,3
OC1/STMO:51.840 Mbps
1,4 2,3
Customized 1
4 1,2,3
Customized 2
1,3,4 2
Open Protocol
1,2,3 4
Mode Select DIP switch toggle Set DIP switch toggles 1 and 2 to the OFF position for normal operation. (In TS800/155 and TS800/155-F set the DS2 1, 2, 3 and 4 toggles to OFF position)
2 – TS700/100 (Fast ethernet)
Compatibility
Peripheral equipment
Check the operation of the peripheral equipment connected with cables (see Configuration 1 below).
Interfaces
Check the specifications compatibility (type, data rate) between the TereScope and the peripheral equipment interfaces.
Test equipment
Chose an appropriate Bit Error Rate (BER) tester for checking the physical link quality. A portable one is preferable since it is more convenient for use in the field.
A ping test or a file transfer between two workstations - connected to the networking equipment - is useful and easy to implement for testing the performance of the whole configuration.
Setup
DIP Switch Set DIP switch toggles 1 and 2 to the OFF position for normal operation.
Set DIP switch toggle 4 for the speed. Usually with Cisco Switches set the TS to Auto-negociation mode.
Page 38
MRV Communications, Inc. – Installation Manual
28
3 – TS700/G
Compatibility
Peripheral equipment
Check the operation of the peripheral equipment connected with cables (see Configuration 1 below).
Interfaces
Check the specifications compatibility (type, data rate) between the TereScope and the peripheral equipment interfaces.
Test equipment
Chose an appropriate Bit Error Rate (BER) tester for checking the physical link quality. A portable one is preferable since it is more convenient for use in the field.
A ping test or a file transfer between two workstations - connected to the networking equipment - is useful and easy to implement for testing the performance of the whole configuration.
Setup
DIP Switch Set DIP switch 1 to OFF (attenuated transmitter) in order to enable short range operation with minimal extra attenuation. Set DIP switch 4 to appropriate protocol – ON for Gigabit Ethernet, OFF for FiberChannel.
Bench test
To learn more about TereScope Bench Test, please refer to Appendix E.
Configuration 1: (App licab le to all m o dels)
Peripheral/Testing
Equipment
RX TX
Peripheral/Testing
Equipment
TXRX
Cables
Configuration 2: (App licab le to all m o dels)
BER Tester
TX RX
UWIN
RX
TX
UWIN
RX
TX
IR link
Peripheral equipment and cable testing
1-way Airlink BER test
TS
TS
Page 39
MRV Communications, Inc. – Installation Manual
29
Or F/O Cable
Or F/O Cable
Configuration 3: (App licab le to all m o dels)
UWIN
RX
TX
UWIN
RX
TX
IR link
BER Tester
TXRX
Configuration 4: (App licab le to all m o dels)
Peripheral
Equipment
UWIN
RX
TX
TX RX
Peripheral
Equipment
UWIN
RX
TX
TXRX
IR link
WorkstationWorkstation
Configuration 5: (App licab le to all m o dels)
Peripheral/
Testing
Equipment
Peripheral/
Testing
Equipment
IR link
TereScope
STP
cable
TereScope
STP
cable
Display and Results
1. TS700/155, TS800/155 & TS800/155-F
Proper Display
1.
Indicators
Indicator
AIR RX F/O RX
Position
Flag Sync Flag Sync
Alignment Loopback
ON
x x x x
OFF
x x
Table 7: Indicators
Loop-back Airlink BER test
Whole configuration operating test (Ping test or File transfer) for Ethernet or Fast Ethernet systems
Whole configuration operating test for all models
TS
TS
TS TS
Page 40
MRV Communications, Inc. – Installation Manual
30
2.
Received power
100 < OPTICAL POWER < 1000
Expected Results
The BER must be less than 10E-12 (10
-12
) for on-going tests and error-free for
short tests.
2. TS700/100
Proper Display
2.
Indicators
Indicator
AIR RX 100baseT
Position
Flag TX Flag TX
Alignment Loopback
ON
x x x x
OFF
x x
Table 8: Indicators
3.
Received power
100 < OPTICAL POWER < 1000
Expected Results
The BER must be less than 10E-12 (10
-12
) for on-going tests and error-free for
short tests. The PING test and file transfer procedure should not post any TIME OUT alarm
or last too long time so long as the cabling connection is OK.
3. TS700/G
Proper Display
3.
Indicators
Indicator
AIR RX Electrical
Position
Flag Laser Enabled Flag
ON
x x x
OFF
Table 8: Indicators
4.
Received power
100 < OPTICAL POWER < 1000
Expected Results
The BER must be less than 10E-12 (10
-12
) for on-going tests and error-free for
short tests. The PING test and file transfer procedure should not post any TIME OUT alarm
or last too long time so long as the cabling connection is OK.
Page 41
MRV Communications, Inc. – Installation Manual
31
Figure 5.1a: JMP-L
Installation
This chapter shows how to mount the TereScope and and accessories at the site (see Appendix D for the required material).
See Unpacking Instructions in Appendix C.
CAUTION: TereScope must be mounted in the horizontal position only; max angle 45o
Accessories
The standard mounting accessories are supplied with the transceivers (TereScope heads) in the kit. They are designed for typical mounting on horizontal and vertical surfaces.
Description
The accessories kit (supplied by MRV) consists of:
o The Mounting Plate for TS700 and TS800
series (JMP-L)
o The Aiming Head o The Installer Tool Kit (JITK-L)
The JMP-L is used for mounting the transceiver on the support surface, i.e., a horizontal concrete surface/plate only.
Chapter
&
&&
&
JMP-L Mounting Plate (Dimensions in
mm)
Dimensions in mm
Screw for grounding
Figure 5.1b: JMP-L scheme
Page 42
MRV Communications, Inc. – Installation Manual
32
Fig. 5.3a: Rear door fixation
Fig. 5.3b: Rear door fixed
Figure 5.2: TereScope Parts – External view
Table 9: TereScope Parts
Part Description Part Description
A Screw for Grounding H(x5) Door lock Captive Screws B Right-Left Fine Alignment Screws I Door Axis C Up-Down Fine Alignment Screws J Cable Duct
I (Axis)
H (x5)
C
B
A
J
Rear Door
JMP-L
Aiming Head
O: Anchoring hole for the rear door
Rear door anchored
Page 43
MRV Communications, Inc. – Installation Manual
33
Fig. 5.4: Mountin
g
kit
Fig. 5.5: Mountin
g
kit – Top view
Fig. 5.6: Mountin
g
kit – Back view
Fig. 5.7: Mountin
g
kit – Side view
Figures 5.7a – 5.7b: Mountin
g
kit – detailed views
Fig. 5.8a
Fig. 5.8b
Fig. 5.8c
AIMING HEAD ADJUSTMENT AND LOCKS:
B: Right-Left (Horizontal) Fine Alignment Scre ws (2)
C: Up-Down (Vertical) Fine Alignment Screw s (2) D: Fine Vertical Aiming Locking Bolts (2) E1/E2: Aiming Lug (2) F1: Horizontal Aiming Locking Bolts (after aiming is completed) F2: Vertical Aiming Locking Bolt (after aiming is completed) (one on
the right side and one on the left side).
G1: Horizontal Aiming Axis G2: Vertical Aiming Axis (two screws – one on each side) K: Fine Horizontal Aiming Locking Bolts (2) L1/L2: Aiming anchor (L1 for Horizontal aiming , L2 for Vertical aiming)
Alignment Kit
B
F1
G1
E1
K
E2
L1
C
D
F2
G2
L1
L2
Page 44
MRV Communications, Inc. – Installation Manual
34
The Installer Tool Kit (JITK-L)
The JITK-L tool kit includes the work tools required for opening and closing nuts and screws of the TereScope for optimal installation. It is recommended that these tools be used. MRV supplies this tool kit with each TereScope head. In addition to the tool kit, screws are supplied for mounting the JMP-L on a pedestal that is supplied by MRV as an option.
Fig. 5.9: JITK: Installer Tool Kit
Mounting
1- Detachment of the TS from the JMP-L
The TereScope Head, Aiming Head, and JMP-L are shipped connected to one another. Before mounting, in order to make installation on the mounting surface easier, the JMP-L must first be detached and connected to the fixation surface. Next, the TereScope Head and Aiming Head can be mounted. To detach the JMP-L, screws ‘B’ should be loosened and screws ‘F1’ and ‘G1’ only should be removed. Do not remove the ‘G2’ screws !
If the TereScope head is to be detached (e.g., for servicing, but we recommend to send the entire unit TS + Aiming head to the manufactory), remove the four ‘G2’ and ‘F2’ screws (Fig 5.11).
JITK: Installer Tool Kit
Figure 5.10a: Mounting TS on JMP
G2 (x2)
G1
F1 (x2)
Figure 5.10b and 5.10c: Screws to be removed G1 and F1
B
Page 45
MRV Communications, Inc. – Installation Manual
35
2- Mounting the accessories
) Horizontal surfaces (parapet, ...):
Figure 5.11: TereScope Detached from the Aiming Head
G2 (x2)
JMP-L
Aiming Head
Figure 5.12: Aiming Head Cradle for TereScope Head
CAUTION! Do not loosen Screws M (x8).
F2 (x2)
N: Grounding screw on TS
T
here are three directional positions for the TereScope mounting on the JMP-L plate: It is possible to mount the TereScope at -60 or +60 degrees from the standard position
Standard position
: A
+
-
`
C
B
Aiming Anchor (L)
Additional possible location for Aiming Anchor
Additional
possible location
for Aiming
Anchor
Figure 5.13a: JMP-L mounting positions
L2
Page 46
MRV Communications, Inc. – Installation Manual
36
THE JMP-L SHOULD BE ORIENTED IN SUCH A WAY THAT THE GROUNDING SCREW IS LOCATED ON THE BACK (CLOSE TO THE INSTALLER) AND THE FRONT FACING THE OPPOSITE SITE.
)
Vertical surfaces (wall, rectangular column, ...):
Note
For more convenience it is suggested to assemble the 3 parts of the JMB before mounting it on the surface.
Special Mounting
1- Mounting on the floor
In some cases the only place where the installation is acceptable, possible, or authorized is on the floor. Avoid installation on roofs with a metallic parapet or without a parapet by drilling holes in the roof floor.
&
&&
&
*These bolts and nuts are included in the kit
Figure 5.13b: JMP-L on the fixation surface
JMP-L
JMB Left
JMB Right
M8 (25mm)* 6places
Use a JMB (To be ordered separately, not included in the standard kit)
Figure 5.14: JMP-L on JMB
Page 47
MRV Communications, Inc. – Installation Manual
37
To use the floor, a very stable tower standing on the floor is required. The transceiver will be fixed on the top of the tower.
Two techniques using a small concrete block are suggested for stabilizing the tower on the floor.
The concrete slab material is poured directly on the base of the tower
Four bolts are inserted in the concrete slab placed on the floor. The tower
mount is fixed on the slab with the inserted bolts using nuts.
TAKE CARE TO REMOVE ANY INTE RVENING SOFT MATERIAL, SUCH AS ASPHALT, BETWEEN THE SLAB/TOWER BASE AND THE F LOOR. ONCE T HE INST ALL ATION IS COMPLETED, RESTORE THE ROOF WATER-TIGHTNESS WITH SEALING MATERIAL AROUND THE SLAB.
2- Mounting on a fragile/crumbly wall
On sites on which the installation on fragile (pre-fab) or crumbly (old building) walls is unavoidable, the best way to strongly fix the JMB is to use a metallic clamping plate on the other side of the wall as sketched below. In this technique a large section of the wall is clasped providing higher rigidity and stability.
!
!!
!
Floor
Concrete Slab
JMP-L
JAH
Transceiver
Tower Mount
Figure 5.15: Mounting on a concrete slab
Clamping Plate
Fragile Wall
Figure 5.16: Mounting on a Fragile wall
Page 48
MRV Communications, Inc. – Installation Manual
38
Note
The Tower Mount and the Clamping Plate are not provided with the equipment and should be supplied by the installer.
3- Attachment of the Transceiver (TereScope Head)
After securely attaching JMP-L to the mounting surface choose one of the three possible directions for installation of the Alignment Kit (Standard A, B or C) depending on the location of the transceiver at the opposite side. Mount the aiming anchor (I) in accordance with the chosen direction.
Mount the Transceiver attached to the mounting bracket front face oriented towards the opposite site using the provided screws (F1, G1). Tighten firmly these screws.
Bolt for the attachment of the Alignment Bracket to the JMP
Figure 5.17: Alignment kit mountedon JMP-L – Back view
Page 49
MRV Communications, Inc. – Installation Manual
39
1 – Make sure that the power cable is disconnected from the electrical power source. 2 – Undo the five screws H -- see Figure 6.1. Holding the Rear Door, Pull the door, turn it clockwise ¼ of a turn around the axis (I), so that a screw will be opposite hole ”O”. Fixe the door on the hole ”O” with the screw.
3 – Connect the wires of the power cable (see Figure 6.4) to the Terminal Block (see Figure 6.5) paying attention to L=Line, G=Ground & N=Neutral.
4 – After connecting the power cables to corresponding sockets, tightly close the screws of the Terminal block – see Figure 6.5. Gently jerk the cable to check that it stays connected. Cover the Terminal Block with a plastic cover (if available).
Fig. 6.5: Power Terminal Block Locked
6 – Rotate and push the Back Door up, and tighten the five H screws.
7 – Connect the power cable to the electrical power source to power on the TereScope.
Captive Screws H
5 – Cover the Terminal Block with the power supply cover.
Fig. 6.6: Power Cable and Fiberoptic Cable
Aiming Procedure
Point to point connections require the orientation face to face of both “transceiving” ends of the link. Concerning wireless optical links, this should be done as accurately as possible in order to position the beam symmetrically all around the remote receiv er
.
Powering on the TereScope
Chapter
6
Fig. 6.1: Screws H and door axis
Fig. 6.4: Power cable & Terminal block
Fig. 6.2: Back Door Rotated ¼ of a turn
Door axis I
Fi
g
. 6.3: View on Door axis
Fig. 6.7: Power Supply Cover
Power Supply Cover
Fiberoptic Cable
Power Cable
Door axis I
Back Door
Hole “O” and the opposite screw
Door axis I
Page 50
MRV Communications, Inc. – Installation Manual
40
Fig. 6.8a and 6.8b: Screws for coarse alignment
Transceiver Alignment
General
Point-to-point connections require face-to-face orientation of both transceiving ends of the link. With wireless optical links, the beam spot should be positioned symmetrically on the remote receiver, as accurately as possible.
Successful installation of the TereScope depends primarily on precise and accurate optical alignment. Carefully follow the instructions below!!!
Tools and Equipment
Note
The customer can order patch cables and high-outpu t portable source from MRV.
The following tools and equipment are required at each link end:
A communication device (mobile phone or walkie-talkie)
Optical-power meter, giving readings in milliwatts/microwatts or
dBm. (The Optical power meter is convenient though not necessary.)
JITK-L.
Procedure
Turn on the power to the TereScope heads from the power source. Models TS700/155 ,TS700/100 and TS800/155: Set DIP switch toggles 1, 2 to the “Alignment” position (indicated on the back panel). In TS800 models set the SD2 DIP switch. In TS700/100 only DIP switch toggle 1. Model TS700G: Even if the data port is left unconnected, the TereScope transmits an Idle Signal which can be used to perform alignment. The transceiver alignment procedure is implemented in two stages:
# Coarse Alignment # Fine Alignment
Coarse Alignment
1. Make sure that both axes (horizontal ‘G1’ and vertical ‘G2’) can
turn freely (but you should’nt loosen or open the ‘G2’ screws). Loosen bolts F1 and K at least two turns and G1 aiming axis loosen slightly. Loosen bolts D and bolts F2 on both sides of the transceiver.
F1
G1
C
D
F2
G2
K
B (x2)
Page 51
MRV Communications, Inc. – Installation Manual
41
Fig. 6.9: Telescope crosshair on the opposite TereScope
2. While looking (see fig 6.9 below) through the telescope, rotate and tilt the TereScope to bring the telescope crosshairs on the left side (your right side) of the opposite TereScope.
3. Tighten firmly 4 Bolts K and D in such a way that the aiming anchors (L1&L2) will be between the screws C and B.
Fine Alignment
The purpose of fine alignment is to position the center of the transmitted beam spot on the center of the TereScope receiver – in both directions (Fig
6.10). This is achieved by adjusting the horizontal and vertical motion screws (shown in Figure 6.11) until maximum power is received at the opposite TereScope.
Transceiver
Beam Cross Section
H1
H2
V2
V1
Figure 6.10: Front view – Transceiver at the middle of the beam cross section
Figure 6.11: Fine Alignment Motion Screws
Fine Alignment Vertical Motion Screws
Fine Alignment Horizontal Motion Screws
Page 52
MRV Communications, Inc. – Installation Manual
42
Fine Alignment Vertical Motion Screws – Two screws (‘C’). Used for fine rotation of the TereScope in the vertical plane. Fine Alignment Horizontal Motion Screws – Two screws (‘B’). Used for fine rotation of the TereScope in the horizontal plane..
Note
# Two installers are required for fine alignment, one
at each TereScope site.
#
The installers should each have a walkie-talkie, a mobile phone or any other equipment to enable each to talk to the other working at the opposite site.
The fine alignment procedure is as follows:
1. Find the horizontal and vertical Beam edges (H1, H2, V1, V2) by obtaining a reading between 50 and 80 on the 7-segment display. (between 250 and 300 for the TS700/G)
2. Set successively the remote transceiver in the middle of the two segments [H1,H2] and [V1,V2].
H1 H2
V1
V2
Important: Do not in any case select the head position for which the DVM reading is maximum! The best position of alignment is the beam center.
To determine the horizontal beam edges H1 and H2, move the local transceiver slowly left and right until the digital readout on the remote transceiver becomes 50. (250 for the TS700/G) Identify these two points relative to reference points on the opposite site by looking through the telescope. By moving the local transceiver, set the remote transceiver at the middle of these two reference points.
H1 H2
V1
V2
Figure 6.12: Position at the beginning (after the coarse alignment)
Figure 6.13: Position after the horizontal a i ming
Page 53
MRV Communications, Inc. – Installation Manual
43
Fig. 6.15a and 6.15b: Alignment screws
Repeat this process for the vertical positioning (middle of segment [V1,V2]).
H1
H2
V1
V2
Once the position is reached, tighten firmly the 4 Fine Locking Screws (2xF2, 2xF1 and G1).
Repeat this procedure interchanging roles with the second installer at the opposite site, i.e., the second installer will move the remote transceiver while the first installer will report the digital readout at his end).
After finishing the alignment process it’s possible to remove the alignment kit (2 Aiming Lugs E1, E2 and Bolts K and D and screws B and C).
At the end of the procedure, t he digital readout should be approxi mately the same on both transceivers (see Appendix B page 44 for expected readings).
(
Figure 6.14: Final position after the ver tical aiming
F1
G1
C
D
F2
K
B (x2)
E2 (and 2 screws ‘C’and 2 bolt s ‘D’) can be removed after finishing the alignment process.
E1 (and 2 screws ‘B’ and 2 bolts ‘K’) can be removed after finishing the alignment process.
Page 54
MRV Communications, Inc. – Installation Manual
44
Captive Screws H
Link Operating Test
Set back the Mode Select Dip-Switch on the Normal position (the Alignment indicator should switch OFF (if exists depending on the model)).
At both sites, connect with fiberoptic or STP cables coming from the peripheral equipment to the fiberoptic or copper port of the transceiver.
IT IS A CROSS CONNECTION:
TX $RX AND RX $ TX
The F/O RX Flag and Sync. (Electrical flag and Rx on TS700/100) indicators should turn ON as soon as the peripheral equipment is powered ON.
A BER test is recommended. In case this is not possible at least check with the customer/user the performance of the whole link (see the chapter Bench T est).
Installation Log
Write down all the information about the installation (including digital readout and the setup of the transceivers) in an installation log. This information is a valuable reference for future maintenance or troubleshooting visits.
An example of an installation form is shown in Appendix H.
Before Closing the Rear Door
1. Ensure that the Power Supply Cover is fastened in place.
2. All cables are properly held in position.
Visual Inspection
Visually check that all parts and cables are connected.
Closing the rear door
Rotate the Rear Door around the axis (I) and push it. Close the five screws H -
- see Figure 6.16., .
Installation Completion
Check that the heads appear as shown in the photographs below.
Fig. 6.16: Screws H and door axis
Door axis I
Page 55
MRV Communications, Inc. – Installation Manual
45
Fig. 6.17: Mounted TereScope – Left View
Fig. 6.18: Mounted TereScope – Back View
Fig. 6.19: Mounted TereScope – Front View
Page 56
MRV Communications, Inc. – Installation Manual
46
Maintenance
Periodic Visits
Periodic visits (every three/six months, depending on the installation environment) should be planned for:
Checking the display
Checking the mounting
Cleaning the optical aperture of the transceivers
Cleaning the building windows for indoors installations.
At cleaning time, the reading of the digital readout should be noted in a service log book. If after the optical aperture is cleaned the reading is substantially lower than that noted at installation time, the aiming accuracy should be examined and restored if necessary.
Note
Aiming accuracy should be checked looking through the telescope and comparing the present scene sighting to the one sketched in the Installation Log at installation time.
Chapter
(
Page 57
MRV Communications, Inc. – Installation Manual
47
Product Specifications
)high speed Light (700/155TS
Part Number
Model
TS155/A/YUW/VS
TS700/155
Application /
Data Protocol
T3, E3, Fast Ethernet and ATM
Performance
Rate 1-155 Mbps
Range
(1)
@ 3dB/km 880 m @ 5dB/km 770 m
@ 10dB/km 600 m @ 17dB/km 480 m @ 30dB/km 360 m
Minimum Range 10 m
Bit Error Rate Less than 1E-12 (unfaded)
MTBF 10 years
Transmitter
Light source 1 VCSEL
Wavelength 830-860 nm
Total Output power 5 mW
Beam divergence 3-4 mrad
Receiver
Detector Silicon Photodiode
Field of view 14 mrad
Sensitivity -34 dBm
Interface
Type
Fiber Optic Transceiver - Multimode (Singlemode available
upon request)
Connectors SC (other connectors available)
Wavelength 1300 nm (other wavelength available)
Output power -17 ± 3 dBm
Receiver
Operating range
-14 to –30 dBm
Power Supply
Factory set: 100-240 VAC @ 50/60 Hz
or
24-60 VDC
(10 W)
Environmental
Operating Temp. -50 °C to +60 °C
Information
Storage Temp. -50 °C to +70 °C
Humidity 95% non-condensing
Housing Weatherproof – IP 66
Eye safety Class 1M
Mechanical
Dimensions [mm] 470 X 282 X 390
Design
Weight Unit 5 kg
Accessories 3.5 kg
Diagnostics
Indicators Airlink: Flag, Sync. Fiber Optic: Flag, Sync.
Indicators /
Receive Signal Strength (Digital Display)
Selectors
Selectors Data Rate, Alignment, Loopback (local)
Management SNMP Protocol – Optional
(1)
3dB/Km: Light rain (5 - 10mm/hr) - Light Haze 5dB/Km: Light to medium rain (15 - 20mm/hr) - Haze 10dB/Km: Medium to Heavy rain (45mm/hr)-Light snow-Thick fog 17dB/Km: Cloudburst (100mm/hr)-Medium snow-Light snow 30dB/Km: Rain (up to 180mm/hr)-Blizzard-Moderate fog
A
PPENDIX A
Notes:
Page 58
MRV Communications, Inc. – Installation Manual
48
TS700/100 (Fast-Ethernet Light)
Part Number
Model
TS100/A/FET/VS
TS700/100
Application /
Data Protocol
Fast Ethernet
Performance
Rate 100 Mbps
Range
(1)
@ 3dB/km 880 m @ 5dB/km 770 m
@ 10dB/km 600 m @ 17dB/km 480 m @ 30dB/km 360 m
Minimum Range 10 m
Bit Error Rate Less than 1E-12 (unfaded)
MTBF 10 years
Transmitter
Light source 1 VCSEL
Wavelength 830-860 nm
Total Output power 5 mW
Beam divergence 3-4 mrad
Receiver
Detector Silicon Photodiode
Field of view 14 mrad
Sensitivity -32 dBm
Interface
Type Electrical – 100Base Tx
Connectors RJ45
Cable STP
Power Supply
Factory set: 100-240 VAC @ 50/60 Hz or
24-60 VDC
(10 W)
PoE (Power over Ethernet) in DC (low Voltage) models (V3)
Environmental
Operating Temp -50 °C to +60 °C
Information
Storage Temp -50 °C to +70 °C
Humidity 95% non-condensing
Housing Weatherproof – IP 66
Eye safety Class 1M
Mechanical
Dimensions [mm] 470 X 282 X 390
Design
Weight Unit 5 kg
Accessories 3.5 kg
Diagnostics
Indicators Airlink: Link Flag, Data, 100Base-T: Link Flag, Data
Indicators /
Receive Signal Strength (Digital Display)
Selectors
Selectors Loopback (local), Ip address
Management SNMP Protocol – Optional
(1)
3dB/Km: Light rain (5 - 10mm/hr) - Light Haze 5dB/Km: Light to medium rain (15 - 20mm/hr) - Haze 10dB/Km: Medium to Heavy rain (45mm/hr)-Light snow-Thick fog 17dB/Km: Cloudburst (100mm/hr)-Medium snow-Light snow 30dB/Km: Rain (up to 180mm/hr)-Blizzard-Moderate fog
Notes:
Page 59
MRV Communications, Inc. – Installation Manual
49
TS800/155 (high speed Light)
Part Number
Model
TS155/C2/YUW/VS or TS155/C2/YUW/FS
TS800/155 or TS800/155-F
Application /
Data Protocol
Fast Ethernet, ATM, OC3,STM1, SMPTE, E3, T3, OC1/STM0
& Open Protocol
Performance
Rate 1-155 Mbps
Range
(1)
@ 3dB/km 1900 m @ 5dB/km 1600 m
@ 10dB/km 1150 m @ 17dB/km 850 m @ 30dB/km 600 m
Minimum Range 10 m
Bit Error Rate Less than 1E-12 (unfaded)
MTBF 10 years
Transmitter
Light source 1 Laser
Wavelength 830-860 nm
Total Output power 28 mW
Beam divergence 3 mrad
Receiver
Detector Silicon Photodiode
Field of view 14 mrad
Sensitivity -37 dBm
Interface
Type
Fiber Optic Transceiver - Multimode (Singlemode available
upon request)
Connectors SC (other connectors available)
Wavelength 1300 nm (other wavelength available)
Output power -17 ± 3 dBm
Receiver
Operating range
-14 to –30 dBm
Power Supply
Factory set: 100-240 VAC @ 50/60 Hz
or
24-60 VDC - (10 W)
Environmental
Operating Temp. -50 °C to +60 °C
Information
Storage Temp. -50 °C to +70 °C
Humidity 95% non-condensing
Housing Weatherproof – IP 66
Eye safety Class 1M
Mechanical
Dimensions [mm] 470 X 282 X 390
Design
Weight Unit 5 kg
Accessories 3.5 kg
Diagnostics
Indicators
Airlink: Flag, Sync. Fiber Optic: Flag, Sync., Alignment mode,
Loopback mode, Remote LoopBack mode,Fusion mode and
activity, Software mode,Laser status, Management Tx and RX,
F/O Redundant Link and Sync., Receive Signal Strength (Digital
Display)
Selectors
Selectors
Data Rate, Alignment, Loopback (local), Remote LoopBack,
Alignment Signal Attenuation, Laser power off, Fusion, Window
Heater (if exists), Ip address , Control Mode.
Management 2 Dry Contacts (AirLink and FO Link)
SNMP Protocol Built in
(1)
3dB/Km: Light rain (5 - 10mm/hr) - Light Haze 5dB/Km: Light to medium rain (15 - 20mm/hr) - Haze 10dB/Km: Medium to Heavy rain (45mm/hr)-Light snow-Thick fog 17dB/Km: Cloudburst (100mm/hr)-Medium snow-Light snow 30dB/Km: Rain (up to 180mm/hr)-Blizzard-Moderate fog
Notes:
Page 60
MRV Communications, Inc. – Installation Manual
50
TS700/G (Giga-Light)
Part Number
Model
TS1000/A/YUW/VS
TS700/G
Application /
Data Protocol
Gigabit-Ethernet, Fiber Channel
Performance
Rate 1.0625Gbps & 1.25 Gbps
Range
(1)
@ 3dB/km 1000 m @ 5dB/km 900 m
@ 10dB/km 690 m @ 17dB/km 540 m @ 30dB/km 400 m
Minimum Range 40 m
Bit Error Rate Less than 1E-12 (unfaded)
MTBF 10 years
Transmitter
Light source 1 VCSEL
Wavelength 830-860 nm
Total Output power 15 mW
Beam divergence 3.5 mrad
Receiver
Detector APD
Field of view 8 mrad
Sensitivity -33 dBm
Interface
Type
Fiber Optic Transceiver - Multimode (Singlemode available
upon request)
Connectors SC (other connectors available)
Wavelength 850 nm (other wavelength available)
Cable Up to 220m length @ 62.5um
&
Up to 500m length @ 50um
Output power -4 to -9.5 dBm
Receiver
operating range
0 to –17 dBm
Power Supply
Factory set: 100-240 VAC @ 50/60 Hz
or
24-60 VDC - (10 W)
Environmental
Operating Temp. -30 °C to +50 °C
Information
Storage Temp. -50 °C to +70 °C
Humidity 95% non-condensing
Housing
Weatherproof – IP 66
Eye safety Class 1M
Mechanical
Dimensions [mm] 470 X 282 X 390
Design
Weight Unit 5 kg
Accessories 3.5 kg
Diagnostics
Indicators Airlink: Flag, Fiber Optic: Flag, Laser enabled.
Indicators /
Receive Signal Strength (Digital Display)
Selectors
Selectors
Data Rate, Power attenuator (for short distance), IP address
setting
Diagnostic
4 dry contacts for: Airlink Flag, Fiber Optic Flag, Laser enabled
and Power
Management
SNMP Protocol – Built-in
(1)
3dB/Km: Light rain (5 - 10mm/hr) - Light Haze 5dB/Km: Light to medium rain (15 - 20mm/hr) - Haze 10dB/Km: Medium to Heavy rain (45mm/hr)-Light snow-Thick fog 17dB/Km: Cloudburst (100mm/hr)-Medium snow-Light snow 30dB/Km: Rain (up to 180mm/hr)-Blizzard-Moderate fog
Notes:
Page 61
MRV Communications, Inc. – Installation Manual
51
Digital Readout vs. Distance
These tables are only intended to give you an idea of what digital r eadout you could expect according to the distance to link.
D= Distance [m] R= Reading (Digital readout)
D 50 100 150 200 250 300 350 400 450 500 550 600 650 700 R 560 520 420 360 300 240 180 140 120 100 80 60 40 30
D 50 100 200 400 500 600 800 900 1000 1100 1300 1500 1700 1900 R 960 760 520 410 380 330 210 170 130 100 70 40 35 25
Actual reading may be greater or up to 15% lower.
D 50 100 150 200 250 300 350 400 450 500 550 600 680 1000 R 1150 1150 1110 1020 940 880 800 730 640 580 520 470 400 250
Actual reading may be greater or up to 15% lower. NOTE: with the Transmitter in “Attenuated” mode for distances under 150m
(DIP switch toggle 1 OFF), the DVM should show readings varying from 800 to 1150.
A note on the Digital Readout Charactersitics of the TS700/G
The digital readout of the TS700G works under a different principle from previous TereScopes in the series. The readout level is derived from the actual light level at the photodetector, much like a standard optical power meter. For this reason, background light entering the lens will also contribute to the reading. A typical reading with no signal on a sunny day would be 030 to 080. This will sum with the signal strength, so outside the reading at the minimum threshold would be higher than the reading for the corresponding signal in a bench test. Due to the AGC function, for higher signals the offset in the reading gradually becomes negligible. All this has no effect on the actual link performance. Please note, however, that the Air Rx LED is not affected by background light, and is purely a function of the received data level. So even with high background light reading, the Air Rx LED will not light in the absence of signal.
TS700/155 TS700/100
TS800/155
TS700/G
APPENDIX B
Page 62
MRV Communications, Inc. – Installation Manual
52
Unpacking Instructions for TereScope
The TereScope is shipped pre-assembled. See fig.C2
1. Unpack all the accessories.
2. .Before mounting, in order to make installation on the mounting surface easier, the JMP-L must first be detached and connected to the fixation surface.
To detach the JMP-L, screws ‘B’ should be loosened and screws ‘F1’ and ‘G1’ only should be removed, shown in Fig: C2, C3a and C3b. Do not remove the
‘G2’ screws !
KEEP IN SECURE PLACE ALL THE BOLTS AND SCREWS. YOU WILL NEED THEM FOR THE INSTALLATION.
APPENDIX C
&
The packing box contains:
# 2 x TereScope Transceivers
mounted
# JITK-L : Installer tools kit
and screws
# CD manuals # Flexible ducts x 2 # Flange x 2
Fig C.1: TereScope as is packed
Figure C2: Detach JMP-L from TS
G2 (x2)
G1
F1 (x2)
Figure C3ab and C3b: Screws to be removed G1 and F1
B
Page 63
MRV Communications, Inc. – Installation Manual
53
Tool Kit, Equipment, and Materials
TOOLS
1. Electric drill (impact for masonry), reversible, with speed control and 0-13mm chuck
2. Drills set High Speed Steel (HSS) 3-13mm.
3. Concrete carbide .bit drills 6,8,9 and 10mm (regular and long shank).
4. Adjustable (crescent) wrench 6”, 10”.
5. Open-ring wrenches (spanners), standard and metric.
6. Vice grip pliers 10-12”
7. Cutter, long nose pliers, electrician’s pliers (insulated).
8. Pen, Pencil, Permanent markers.
9. Lens cleaning clothes.
10. Screwdrivers (flat and Philips), sizes 1, 2, 3 + power screwdriver bits.
11. 50m extension cable + 3 outlet multiple electrical tap
12. 200g hammer.
13. Blade knife.
14. Ratchet handle driver.
15. Socket wrenches 8mm, 10mm, 11mm, 13mm, 14mm, ½” .
16. Allen 8mm and Allen 2.5mm.
MATERIALS
1. Anchors (wall plugs) “UPAT” 13mm diameter
2. Hex-head screws to fit wall plugs 40, 60, 75mm length.
3. Assortment of screws, nuts, washers, spring washers.
4. Electric insulation tape.
5. Super glue, tie wraps (Panduit™).
6.
20 mm fuse SB, 125mA, 160mA, 250mA, 500mA, 1A
ELECTRONIC & GENERAL
EQUIPMENT
1. Digital voltmeter (DVM)
2. 2 Walkie Talkies or cellular phones.
3. Binoculars
4. Four STP cables (two cross and two straight) terminated with RJ-45 connectors each end.
OPTICAL EQUIPMENT
(if relevant)
1. Optical Power Meter (Fotec, Noyes, Acterna…) with fiber so ckets.
2. 2 sets of multimode (62.5 µm) and Singlemode (15µm) optical fibers with SC terminations.
LAB EQUIPMENT
E1/ETH/ATM/Fast Ethernet BER Test equipment- depending on TS model.
APPENDIX D
Page 64
MRV Communications, Inc. – Installation Manual
54
A LIST OF THE TOOLS SUPPLIED BY MRV COMMUNICATIONS
WITH EVERY TereScope HEAD
Description Qty Where to use
a. WRENCH #8 for Aiming
Head, (M5 nut)
1 N: Grounding screw on
TereScope (see page 29) (Also for rear door axe : I)
b
BALLDRIVER L, WRENCH 5mm for Allen Screw M6
1 F1 and F2: Screws for Vertical and
Horizontal coarse Aiming
c
BALLDRIVER L, WRENCH 3mm for Allen Screw M5
1 H: Rear Door lock captive screws
d
WRENCH #13 (M8 Hexa. Screws)
1
A: JMP-L - Grounding screw Screws between JMP-L and JMB
(if needed) Screws between JMP-L and
pedestals (if needed)
e
BALLDRIVER L, WRENCH 8mm for Allen Screw M10
1 G1: Horizontal axis and locking
screw for horizontal aiming
f M8 SCREWS, WASHERS,
SPRINGS, NUTS
4 of each Optional. To mount JMP-L on
standard pedestal
g INSTALLATION TOOL
CASE
1 Tool case
Wrenches Kit for TS I nst allat ion
Page 65
MRV Communications, Inc. – Installation Manual
55
TereScopes Bench Test Procedure
Introduction
All TS Products are bench tested indoors prior to outdoor installation to ensure that the system is fully functional. The bench test is a simple procedure whereby a link pair is aligned on the table and activated to simulate a channel of communication (see fig.1).
2 Points to Remember
1. Since the link distance during the bench test is very short (i.e. the devices activated are very close), the receivers will go into saturation unless the signal is attenuated. (NOTE: In the 700/G, deep into
saturation the DVM reading may actually drop back down, giving the false impression that the link is misaligned. It is therefore vital to place the attenuator in the link path before optimizing alignment.)
To avert entering saturation, the transmit signal must be physically attenuated. We recommend the simple procedure of inserting a piece of paper or the like into the beam path, or concealing a portion of the beam with an opaque (non-transparent) material. This will reduce the signal power entering the receiver. Make sure to attenuate the signal enough so that the receiver’s optical power meter value falls below the saturation estimate of the device. See table below for saturation estimate.
2. An additional derivative of the short link distance is the presence of reflections. The signal will reflect off the front window of the receiver back at the transmitting device and may be mistaken as part of the opposite transmission. This interference is commonly called “cross talk”. To avoid cross talk during the bench test, it is advisable to check whether interfering reflections exist by shutting off power to one device and verifying that the optical power meter reading in the other (active) device is zero. This should be repeated for the opposite device. Alternatively, a practical setup for bench testing the 4” series (models B, C and D) and Light series (models A and C2) is presented in Figure 1; the bench test setup for the 10” series (models E and F) is presented in Figures 2a,2b. In the 4”/Light setup, a thin physical barrier, such as a piece of cardboard, is used as a wall to divide between the beam paths, thus ensuring that no cross talk occurs. In the 10” setup, the two devices are not centrally aligned; instead, only one corner of each device faces the opposite device. This
APPENDIX E
Page 66
MRV Communications, Inc. – Installation Manual
56
allows for testing each transmitter separately. By rotating the devices 45 degrees, the next pair of transmitters is tested. Hence, testing all 8 transmitters in the link pair requires only 4 rotations. In the 8” setup, the two devices are not centrally aligned; instead, only one corner of each device faces the opposite device. This allows for testing each transmitter separately. By rotating the devices 45 degrees, the next pair of transmitters is tested. Hence, testing all 6 transmitters in the link pair requires only 3 rotations. With opaque masking tape, cover all transmitters that are not under test.
Table 1: Bench Test Information for TS Products
Product name
Opt. Power M. “Sub-Saturation”
value
Potential for
Interference TSxxxx 1100 Low TSxxx/ETH 1200 Med TSxxx/E1 1200 High TSxxxx/ST 1200 Med TS2000/XXX 1100 High TS4000/XXX 1200 High TSx00/XXX 1000 High
Figure E.1: Bench Test setup for 4”/Light TS models.
Figure E.2a: Bench Test setup for 10” TS model; transmitter aligned opposite receiver marked with arrows.
Page 67
MRV Communications, Inc. – Installation Manual
57
Figure E.3: Active Transmitters (Shown Darkened).
Figure E.2b: Bench Test setup drawing
for 10” TS model. Note that one device is higher tha n the other and shifted over to the side so that only one transmitter from each device is facing opposite the other device’s receiver.
Telescopes
Page 68
Page 69
MRV Communications, Inc. – Installation Manual
59
Effect of Wind on Ter escopes
Introduction
The outdoor environment in which our devices are normally placed exposes the link to wind pressures that may affect the accuracy of the link’s alignment.
Several factors play a role in the determination of the extent to which the directionality of a TS device may be affected by the wind: Wind speed Wind direction Surface area of device perpendicular to wind Mechanical stability of aiming head – device system.
For example, the mechanical stability is greatest along the side-side axis of the device. Although the surface area along the side of the device is greatest, the resultant wind force – even at very high wind speeds – will barely have an impact on the beam’s direction, due to the rigid mechanics along the side-side axis.
Wind Limits for TS Devices
All TS devices have been tested in “worst-case” scenario of the above four factors. The force necessary to deviate beam was measured from different direction. From here1, the minimum wind speed with maximum effect on beam deviation was determined. The following table lists the minimum wind speeds for different TS products that may cause: A momentary lapse in the communication. An extended lapse requiring mechanical repair.
TS Device Momentary Extended
10” (E&F models)
110 km/hr 200 km/hr
10” with Windproof-L
Accessory
Over 180 km/hr Over 250 km/hr
4” (B,C, D models)
150 km/hr Over 250 km/hr
4” with Windproof-S
220 km/hr Over 300 km/hr
Light (A&C2 models)
150 km/hr Over 250 km/hr
PAL (TS1)
180 km/hr Over 250 km/hr
8” (Models D2, E2, G)
150 km/hr
1
We include here the formula for calculating the effective wind force on a flat surface, given a known wind
speed:
Wind Force = 0.79 x (Wind Speed)2 x (Area of Surface)
For instance, assuming a wind speed of 27.78 m/s (equal to 100Km/hr) on a surface area of 0.04m2 (400cm2), the force is equal to 24.4 Newtons.
APPENDIX F
Page 70
MRV Communications, Inc. – Installation Manual
60
Appendix G
FSO Chaining
What is Chaining?
The Chaining of FSO is required when the two sites are connected by more than one link using at least one additional building as a mid-point.
When is the Chaining required?
The Chaining of FSO links is required in the following cases:
a) When there is no direct line of sight between the sites; b) When the distance between the sites is too long; c) When the distance between the sites is reachable with one link but the customer wants much
more Power Budget for higher reliability.
C
Fig G.1:
As there is no line of sight from A to B, we are using C as a repeater point. On C rooftop we used “ Direct Chaining connectivity
A
B
Page 71
MRV Communications, Inc. – Installation Manual
61
Indirect Chaining
Direct Chaining
Chaining Limits
The number of links that can be chained is limited due to the Jitter parameter. Sensitivity to jitter is different for every protocol and can vary with different manufacturers. The typical number is 3-4 chained links. If more chains are required, please consult your MRV representative.
Indirect Chaining is required for connecting FSO units not including clock recovery circuits. In cases of indirect connectivity, the connection between the two FSO units on the same roof must be done through the Switch or Router or another means of connection that is located inside the building. For example, in Fig. 2, we use the indoor switch in building C for the chaining.
A
B
C
Direct Chaining is the capability to directly connect two FSO units on the same roof (used as repeaters ) i.e.. direct crossing between Rx and TX of the two units. For example, in Fig. 3 connection is achieved on rooftop of building C without the need to enter the building.
Direct connection is possible for FSO that include clock recovery circuits. The clock recovery regenerates the signal and enables smooth direct chaining.
A
B
C
Fig. G.2
Indirect chaining
Fig. G.3
Direct chaining
Page 72
MRV Communications, Inc. – Installation Manual
62
FSO products & Chaining Product series
Chaining No of chained links
TS155-PS (34-155 Mbps)
Direct 3-4
TS 34 (Open Protocol, 1-34 Mbps) Indirect 3-4
TS 10 (Ethernet)
Direct 3-4
TS Mux (Mux 4E1, 4T1)
Direct No Limits*
TS 2 (E1, T1)
Direct No Limits*
*No Limits – it refers to Networking extentions. If the extentions are of TDM type (E1,E3,STM-1, STM-3 ), after some chains we might face some “jitter”problems. Therefore,in such cases, chaining should be considered on a case by case basis.
Page 73
MRV Communications, Inc. – Installation Manual
63
APPENDIX H
Installation Log
D.1. Client / Dealer details
Customer Dealer
Company Name
Address City Country Contact Person Tel Fax e-mail
D.2. Application details
Type of network E1 , Ethernet , Token Ring , Fast Ethernet ,
FDDI , ATM , Other (Specify) Product Evaluated distance by customer Address of installation (site A) Address of installation (site B)
D.3. Sketch of the area
Page 74
MRV Communications, Inc. – Installation Manual
64
D.4. Site survey
Done by Customer representative Distance Date
Site A Site B Location Floor Orientation (NSEW) Installation site scheme
Indoor / Outdoor Plate JMP / Bracket JMB Window attenuation On-line UPS Voltage required (110V / 230V) Ground earthing Radio antenna field
Associated interface equipment
Site A Site B
Manufacturer Type Model number Interface type
Page 75
MRV Communications, Inc. – Installation Manual
65
D.5. Installation
Done by Customer representative Date
Site A Site B System model Serial number Location : Same as site survey, if not provide details
Accessories : Same as site survey, if not provide details
Digital readout Telescope calibration : if cannot , sketch the telescope view
BER test BER equipment type Loopback location Error type (random, burst) Brief interruption test
Page 76
MRV Communications, Inc. – Installation Manual
66
D.6. System failure
Visit made by Customer representative Date
Site A Site B Sketch of telescope view
Digital readout Failure detail
Action items
Visit made by Customer representative Date
Site A Site B Sketch of telescope view
Digital readout Failure detail
Action items
Page 77
MRV Communications, Inc. – Installation Manual
67
APPENDIX I
Power over Ethernet
The Power-over-Ethernet (PoE) option is available only for Low Voltage TereScope model 700/100. PoE eliminates a separate DC power supply cable at each Access Point (AP) location, i.e., it allows f or a single Ethernet cable providing both data and power to be run to each AP instead of two separate cables, one for power and the other for data. There are two types of PoE connections. One type utilizes all 8 wires of the Ethernet cable. The wires that are connected to pins 1, 2, 3, and 6 carry both power as well as data. T he other type utilizes the four wires that are connected to pins 1, 2, 3, and 6 for carrying data, and the four other wires that connect to pins 4, 5, 7, and 8 for carrying power. Pin 4 is shorted to pin 5 and these are connected to the (+) terminal of the power supply. Pin 7 is shorted to pin 8 and these are connected to the (-) terminal of the power supply. Both are floating isolated voltage as is usual for a -48V Telecom supply. TereScope model 700/100 with PoE option supports this second option only (as required per IEEE 802.3af standard) so proper connection to this pins should be provided. The TereScope model 700/100 can be connected by any of the following three methods:
1. TereScope model 700/100 with PoE option is connected directly to PoE-enabled equipment –The only needed part is a straight (non-cross) Category 5 jr 5e cable, which will also supply power to the AP.
2. TereScope model 700/100 with PoE option connected to non-PoE-enabled equipment through an external PoE adapter. The PoE adapter couples an Ethernet Line and DC Power (usually -48 VDC – see low voltage power requirement in Appe n d i x A : s p e c i f i c ations) o n t o a n 8 - w i r e straight (non-cross) Category 5 or 5e cable, as shown in Figure I.1. The other end of the PoE cable is connected directly to the TereScope model 700/100 with the PoE option. Adapters to be used with the TereScope are required to meet the IEEE 802.3af standard. Examples of brands of such adapters are: HyperLink Technologies BT-CAT5-P1, PowerDsine 6001. These two types of adapters are commercially available. This connection is illustrated on Figure I.1.
TereScope model 700/100 with PoE option connected to non-PoE-enabled equipment. In this case 8-wire straight (non-cross) Category 5 or 5e cable at the equipment side should be split on two wires groups. One group with standard pins 1, 2, 3, and 6 and carrying data to non-PoE enabled equipment. The other should be with four wires that connect to pins 4, 5, 7, and 8 for carrying power using external 48V power supply. Pin 4 is shorted to pin 5 and these are connected to the (+) terminal of the power supply. Pin 7 is shorted to pin 8 and these are connected to the (-) terminal of the power supply.
Figure I.1: Power-over-Ethernet Interconnection with external PoE adapter