Installation, Operation and Maintenance Manual
Broadway Collection Electric Towel Warmers
Models: W216, W219, W228, W236, W248
®
mr.steam
_______________________________________________
Model
_______________________________________________
Serial No.
W216C W219C W228C W236C W248C
Feel Good Inc.
TABLE OF CONTENTS
__________________
General Information ........................ 2
Specifications .................................. 2
Wall Preparation .............................. 3
Mounting Dimensions ..................... 3
Installation (Brass brackets) ............. 4
Installation (Plastic brackets) ............ 5
Electrical Connections ..................... 6
Junction Box Connection ............. 6
General......................................... 7
Optional Programmable Timer ....... 7
Installing Optional Accessories ....... 8
Using Essential Oils ......................... 8
Warranty .......................................... 8
IMPORTANT NOTE: As you follow these instructions, you will notice warning and caution symbols. This
blocked information is important for the safe and efficient installation and operation of this Towel Warmer.
These are types of potential hazards that may occur during this installation and operation:
WARNING
states a hazard
!
may cause serious injury or death if
precautions are not followed.
CAUTION
signals a situation where
!
minor injury or product damage may
occur if you do not follow instructions.
IMPORTANT NOTE:
information that is especially relevant to a
problem-free installation.
This highlights
pur
100425 rev 6.15
![](/html/af/af57/af57c81200ff476f66218ca3ca55f7936439cd99ea6dadb090e35dbb839aef59/bg2.png)
mr.steam
®
Broadway Collection Towel Warmers Installation, Operation & Maintenance Instructions
_______________________________________________________________
HOMEOWNER:
__________________________________________________
THANK YOU for selecting Mr.Steam Towel Warmer, the
perfect addition to bathrooms, family spas, and exercise
rooms within your home. Our products have been a standard for quality and comfort, and we are sure that you will
experience continued enjoyment from the Towel Warmer
you have purchased by following these instructions.
WARNING
!
TOWEL WARMERS ARE HOT! The
Towel Warmer is an electrical heating appliance, intended
only for indoor residential applications and, as such, should
be installed and used with certain precautions for your
safety.
1. INSTALLATION PROCEDURES FOR PERMANENTLYWIRED WALL-MOUNTED UNITS MUST BE
ACCOMPLISHED BY QUALIFIED PERSONNEL IN
STRICT ACCORD WITH APPLICABLE NATIONAL AND
LOCAL BUILDING AND ELECTRICAL CODES.
2. DO NOT place TOWEL WARMER units inside a shower,
sauna or steam room enclosure or any other wet location or with elevated temperature because the towel
warmer may be an electrocution hazard.
3. CAUTION is advised when a Towel Warmer is accessible
to children because the towel warmer is hot and represents a burn hazard.
4. A dedicated wall switch or timer should be used to control the TOWEL WARMER unit. Contact Mr.Steam for
an in-wall 24-hour/7day timer (PN 103588DIG) Note: All
switches and control devices must be installed on the
load (black) side of the Towel Warmer circuit in compliance with the National Electrical Code (NEC) and local
code. (see page 7 for installation instructions)
IMPORTANT:
protected and maintained by an occasional wiping with a
soft, non-abrasive, damp cloth and lightly polished, thereafter, with a soft dry cloth when the Towel Warmer is cold.
Under no circumstances should abrasive cleaning powders,
metal polish or chlorine-based cleaners be used on any
part of this product.
IMPORTANT:
only. DO NOT use this appliance to dry wet towels.
IMPORTANT:
The finish of your Towel Warmer can be
This appliance is for warming towels
This appliance is intended for towels
washed in water. Fabrics that contain soap or detergent
residue may show what appears to be scorch marks.
However this may be the discoloration of the residue.
Mr.Steam is not responsible for discoloring or damage
of any fabrics. Refer to the Mr.Steam
towel warmer warranty for additional
terms and conditions.
INSTALLER:
_____________________________________________________
READ THIS ENTIRE INSTRUCTION MANUAL THOROUGHLY
BEFORE BEGINNING INSTALLATION. LEAVE THESE
INSTRUCTIONS WITH HOMEOWNER.
!
• BE CERTAIN ELECTRICITY IS SHUT OFF AT MAIN PANEL
BEFORE ATTEMPTING TO WIRE OR SERVICE THE TOWEL
WARMER. Follow instructions to make certain the Towel
Warmer is properly mounted and secured to the wall. FAILURE
TO FOLLOW THESE STEPS COULD RESULT IN HAZARDOUS
CONDITIONS INCLUDING ELECTROCUTION.
• To avoid possible fire hazard, the Towel Warmer must remain in
its intended position. MOUNT THIS UNIT ONLY AS SHOWN IN
THESE INSTRUCTIONS.
• Do Not alter or modify any Mr.Steam products. Doing so may
result in an inoperable or hazardous installation and will void the
warranty.
!
1. Install in accordance with
National and local codes.
2. Do not locate in shower
stall, tub or near water
spray.
3. Do not locate within
the shower or tub zone.
See illustration.
4. All models are to be protected by dedicated
and suitably rated GFCI circuit breaker or equal.
TO ENSURE CORRECT OPERATION OF YOUR TOWEL WARMER,
PLEASE FOLLOW ALL INSTRUCTIONS CAREFULLY, OBSERVING
THE “CAUTION” and “WARNING” NOTATIONS FOR EACH STEP.
INSPECT TOWEL WARMER
Unpack the Towel Warmer carefully to avoid any damage or
loss of any part. When opening the box be sure that the parts
are not accidentally discarded. Towel Warmers are shipped in
specially designed shipping cartons. The entire surface of the
Towel Warmer is hand-wrapped to protect the finish. It is your
responsibility to immediately inspect for any damage.
TOWEL WARMER SPECIFICATIONS
______________________________________________________________
Model No. Dimensions (inches) Amps Volts/Phase Weight (lbs.)
W x H x D
______________________________________________________________
W216C 15.76 x 20 x 4.375 0.83 120/1 23
______________________________________________________________
W219C 20 x 20 x 4.25 1.67 120/1 24
______________________________________________________________
W228C 20 x 28 x 4.25 3.33 120/1 30
______________________________________________________________
W236C 20 x 36 x 4.25 3.33 120/1 37
______________________________________________________________
W248C 20 x 48 x 4.25 3.33 120/1 45
______________________________________________________________
Note: Dimensions are approximate
WARNING
WARNING
Shower/Tub
Zone
Do not locate the
towel warmer within
the shower/tub zone
For illustrative purposes only
This picture shows the recommended method of draping a towel on a towel warmer. Ensure as
much as possible of the towel’s surface is touching the towel warmer for optimum towel warming.
2
![](/html/af/af57/af57c81200ff476f66218ca3ca55f7936439cd99ea6dadb090e35dbb839aef59/bg3.png)
mr.steam
Upper Header (Z)
Lower Header (Z)
Wiring
Box
Finished
wall surface
Towel Warmer
Y
®
Broadway Collection Towel Warmers Installation, Operation & Maintenance Instructions
_______________________________________________________________
WALL PREPARATION
CAUTION
!
• DO NOT mount the Towel Warmer without providing structurally secure upper and lower headers as
shown.
• DO NOT mount the Towel Warmer directly to
sheet rock or any other non-structural surface.
• Use longer fasteners as required if the finished
wall surface prevents adequate mounting with the
screws provided.
• Provide a clearance hole in the lower header as
required to route field wiring to the Towel Warmer
wiring box.
IMPORTANT NOTE:
instructions on page 6.
IMPORTANT NOTE:
small dimensional variations and must be measured
prior to installation. Do not use dimensions to determine location of mounting holes.
MOUNTING DIMENSIONS (inches)
MODEL X
W216C 12 13 3⁄8 2 x 6
W219C 16 13
W228C 16 21
W236C 16 29
W248C 16 413⁄8 2 x 6
MOUNTING DIMENSIONS (inches)
MODEL A B C D
W216C 4 5⁄16 1 3⁄8 11 13
W219C 4
W228C 4
W236C 4 5⁄16 1 3⁄8 15 29 1⁄2
W248C 4 5⁄16 1 3⁄8 15 41 3⁄8
WARNING
!
Install Towel Warmers in upright position only. Locate wir-
ing box with indicator light on bottom as shown. Failure to
install properly may result in overheating and a hazardous
condition.
IMPORTANT NOTE:
dimensional variations and must be measured prior to
installation. Do not use dimensions to determine location
of mounting holes.
See electrical rough-in
Towel Warmers may have
(min)
(Header horizontal length) (Header vertical length) (Header size)
Y Z
3
⁄4 2 x 6
5
⁄8 2 x 6
1
⁄2 2 x 6
5
⁄16 1 3⁄8 15 13
5
⁄16 1 3⁄8 15 21 5⁄8
3
3
(min)
⁄4
⁄4
Towel Warmers may have small
For Technical Service Assistance:
East Coast Tel: 1-800-767-8326
West Coast Tel: 1-800-727-8326