Technical Specifications
______________________________________________________ Model SAH6000
Ideal for starter homes and guest baths
• Ideal for ceramic, porcelain, glass tiles & acrylic enclosures
• Rugged stainless steel generator with electronic printed circuit board available in 208V or 240V 1 Phase
• Uses less than one gallon of water for a 20-minute session
• 23% more compact than standard MS steam generators
• Integral safety time-out feature
• Built-in drain valve
• Made in the USA
Safety Features
• Built-in, low-voltage 24-volt control
• ASME safety valve
• 60-minute electronic countdown shutdown with 75-minute limiting safety back-up
Locating and Installing the Steam Generator Unit
• Select a location as near as practi­cal to the steam room, within 60 feet. Typical locations include: closet, vanity cabinet, heated attic or basement
• Do not install steambath generator inside the steam room.
• Do not install steambath generator outdoors or wherever environ­mental conditions may affect the safety and/or performance of the generator
• Do not install steambath generator or plumbing lines in un­heated attic or any locations where water could freeze
• Do not install steambath generator near flammable or corrosive materi­als or chemicals or in areas having a high concentration of chlorine
• Install steambath generator on a solid and level surface or securely mounted to a wall using the key­hole slots provided.
• Install steambath generator in an upright position only
Provide a minimum of (12) inches at
both ends and top of the steam gen­erator or as required for servicing
• Provide unions as required to facili­tate installation and disconnection of the steam generator.
Required Plumbing
Steam Outlet (3/8" NPT) Safety Valve (3/4" NPT) Drain (1/4" NPT) Steam Head (1/2" NPT) Water Supply (3/8" NPT)
Water Inlet
SteamStart
Connection
S
team Outlet
Safety Valve
Manual
Drain Valve
Electrical
All electrical wiring to be installed by a qualified licensed electrician in accordance with National Electrical Code and local electrical code.
Power Wiring
1. Check power voltage. Use 240V rated unit when
supply matches rating of unit before installation.
2. Use minimum 90˚ C/300 V rated insulated copper conductors only, type THHN or equal sized in accordance with National Electrical Code and local electrical code for the Amps in Ampere Chart.
If allowed by code, NM cable may require a larger
wire size than as listed on the chart.
3. Connect suitably sized equipment grounding wire to ground terminal provided.
4. Install a separate circuit breaker between supply and unit. Provide a power supply disconnect within sight of the steam generator or one that is capable of being locked in the open position.
A M P E R E C H A R T
MODEL NO. VOL. CU.FT. KW 1 PH PHASE AMPS (AWG)*
SAH6000 150 6.0 208 1 29 8
MAX ROOM VOLTS WIRE SIZE
240 1 25 8
* for up to 45˚C ambient
FOR ILLUSTRATIVE PURPOSES ONLY.
IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
MODEL VOLTAGE* PROJECT INFORMATION
SAH6000
*
Steam@Home units are only available in single phase
 
B=208
C=240
Location:
Architect:
Engineer:
Notes: