Mr Steam MS90E, MS150E, MS225E, MS400E, MS SUPER 1E User Manual

...
Page 1
Installation, Operation and Maintenance Manual
Steambath Generator Systems
Residential
Models: MS90E – MS400E and MSSUPER1E – 6E
____________________
IMPORTANT:
Leave this material with the home owner.
____________________
mr.steam
®
®
Feel Good Inc.
CAUTION
!
installation, operation and maintenance manual supplied with the product must be used for installation, operation and maintenance purposes. Failure to use the installation, operation and maintenance manual supplied with the product may result in a property damage or personal injury.
This installation, operation and maintenance manual is for general reference. The
Page 2
EA D M E F IRS T!
R
WARNING
!
instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installa­tion and operation of this generator. These are types of potential hazards that may occur during installation and operation:
WARNING
!
hazardous situation, which, if not avoided, could result in death or serious injury.
CAUTION
!
ardous situation, which, if not avoided may result in minor or moderate injury or product damage.
IMPORTANT NOTE:
information that is especially relevant to a problem­free installation.
ll information in these instructions is based on
A
he latest product information available at the
t time of publication. Sussman-Automatic Corporation reserves the right to make changes at any time without notice.
As you follow these
Indicates a potentially
Indicates a potentially haz-
his highlights
T
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
.
1
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
2.
!
WARNING
3.
!
injury or death if improperly used. Steam rooms contain steam and elevated temperatures. Please read and observe all warnings in this manual before installing or using a steam room.
WARNING
4.
!
A. The wet surfaces of steam enclosures
may be slippery. Use care when entering or leaving.
B. The steam head is hot. DO NOT touch the
steam head and avoid the steam near the steam head.
C. Prolonged use of the steam system can raise
excessively the internal human body temper­ature and impair the body’s ability to regu­late its internal temperature (hyperthermia). Limit your use of steam to 10-15 minutes until you are certain of your body’s reaction.
Supervise children at all times
Steam is hot and can cause
To reduce the risk of injury:
D. Excessive temperatures have a high
potential for causing fetal damage dur­ing the early months of pregnancy. Pregnancy or possibly pregnant women should consult a physician regarding correct exposure.
E. Obese persons and persons with a his-
tory of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steambath.
F. Persons using medication should con-
sult a physician before using a steam­bath since some medication may induce drowsiness while other medica­tions may affect heart rate, blood pres­sure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
WARNING
!
Not Actual Size
The use of alcohol, drugs, or medication can greatly increase the risk of hyperthermia.
The manual supplied with the generator includes a peel and stick warning label. Its proper use is an essential part of providing a safe environment for steam room users. The peel and stick warning label must be applied to the wall of the shower or steam enclosure, at a point that is visible to all users. Failure to install this sticker may result in serious injury or death. The location where this owner's manual is kept shall be written in the space provided on the label using permanent ink. For a replacement warning label contact MrSteam customer service at 1-800-76-STEAM or hello@mrsteam.com.
a) Failure to perceive heat; b) Failure to recognize the need to exit the steambath; c) Unawareness of impending risk; d) Fetal damage in pregnant women; e) Physical inability to exit the steambath; and f) Unconsciousness.
Designed, Engineered and Assembled in the
# # # #
USA
mr.steam
43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM FAX: 718 472 3256
9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 1 800 72 STEAM FAX: 310 216 2944
®
Sussman-Automatic Corporation®hello@mrsteam.com www.mrsteam.com
PUR 100472A Rev 8.18
Page 3
RESIDENTIAL STEAMBATH GENERATOR SYSTEMS
INSTALLATION, OPERATION & MAINTENANCE MANUAL
MODEL _______________________________
MODELS: MS-90E, MS-150E, MS-225E, MS-400E, MS-SUPER 1E,
S-SUPER 2E, MS-SUPER 3E, MS-SUPER 4E, MS-SUPER 5E, MS-SUPER 6E
M
TABLE OF CONTENTS
Important Safety Instructions . . . . . . . . . . . . . Inside front cover
Select Your MrSteam Model . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Generator Specification Chart . . . . . . . . . . . . . . . . . . . . . . . . . 2
_______________________________________________________________________
INSTALLER SECTION
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Steam Room Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Water Quality Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Locating the Steam Generator . . . . . . . . . . . . . . . . . . . . . . . 4
Typical Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . 5
Installation: Plumbing, Water Supply, Drain, Steam Outlet
Safety Valve, Drip Pan, AromaSteam . . . . . . . . . . 6
Steam Head Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Steam Generator Dimensions . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Specifications & Field Power Wiring . . . . . . . . . . . 9
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
Optional Tandem Cable Diagram . . . . . . . . . . . . . . . . . . . . 11
Initial Start-Up & Checkout . . . . . . . . . . . . . . . . . . . . . . . . . 12
Optional & Accessary Equipment . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
System Status Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Liquid Level Control Board . . . . . . . . . . . . . . . . . . . . . . . . . 13
Optional AutoFlush System . . . . . . . . . . . . . . . . . . . . . . . . . 14
Optional Drip Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Optional Express Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Parts Identification Diagrams. . . . . . . . . . . . . . . . . . . . . . . . 16
Replacement Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
CONTROL INSTALLATION
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Control Rough-In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
_______________________________________________________________________
SERIAL NO. ___________________________
HOMEOWNER SECTION
Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . 19
Setting Steam Bath Temperature & Duration . . . . . . . . . . . 20
Safety & Operating Info. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Care Tips for Controls and Generator Maintenance . . . . . . 20
Using the AromaSteam Essential Oils . . . . . . . . . . . . . . . . . 21
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
®
mr.steam
Feel Good Inc.
Page 4
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
SELECT YOUR MrSteam
MrSteam @ Your Fingertips:
Start working smarter with MrSteam’s mobile sizing app, now available for the iPad
Visit mrsteam.com to size your generator automatically or go directly to: http://isizing.mrsteam.com
Materials of construction, room size and special design features such
s large glass areas, all affect
a
1.
Measure length, width & height in feet of the steam/shower or tub/shower
Multiply the Length ____ x Width_____ x Height _____ =
2.
Construction Materials:
For natural stones: natural marble, Add 110% stone, shale, glass block or concrete
For ceramic or porcelain tile on Add 40% cement board or mortar bed
3.
Ceiling Height: For each foot above 8 feet Add 15%
4. Add all figures above to obtain the Total Room Volume required
Compare your Room Volume to the Chart below
®
, iPod®and most smart phones.
he steam generator model selection.
t
and select the appropriate model.
ROOM VOLUME
WARNING
!
se of this steambath system, please note that if
u
In considering the purchase or
you are pregnant, have a coronary condition, are in poor health, are being treated for any other medical condition, or are using medication or drugs, MrSteam recommends that you obtain the approval of a physician before use. For information about this product and safety issues, please call 1.800.76.STEAM
IMPORTANT NOTES:
or steam rooms constructed of acrylic or
F synthetic materials, select next lower-rated MS model.
The MrSteam Sizing Chart allows for up to 60 feet of insulated steam line from the MS generator to the steam room. If the 60 foot line is exceeded consult with factory. The steam generator control locations must be taken into account. A 30 foot cable is standard. Contact MrSteam to purchase an optional 60 ft. cable PN 103990-60 for
®
iTempo iSteam
and AirTempo®and PN 104117-60 for
®
. The maximum cable length is 60 feet.
R E S I D E N T I A L S T E A M G E N E R AT O R S S P E C I F I C A T I O N C H A R T
Model No. KW 240v/1PH)† Size‡ Room Vol. Gallons†† Dimensions* Wt. (lbs)**
MS90E 5 21 10 100 0.67 14½"L x 14¾"H x 6¾"D 30
MS150E 6 25 8 150 0.80 14½"L x 14¾"H x 6¾"D 30
MS225E 7.5 32 8 225 1.0 14½"L x 14¾"H x 6¾"D 30
MS400E 9 38 8 360 1.2 14½"L x 14¾"H x 6¾"D 30
MS SUPER 1E 10 42 8 475 1.4 17"L x 18½"H x 77⁄8"D 40
MS SUPER 2E 12 50 6 575 1.6 17"L x 18½"H x 77⁄8"D 40
MS SUPER 3E 15 63 4 675 2.0 17"L x 18½"H x 7
MS SUPER 4E 20 84 8 875 2.7 17"L x 18½"H x 77⁄8"D x 2 80
MS SUPER 5E 24 100 6 1075 3.2 17"L x 18½"H x 77⁄8"D x 2 80
MS SUPER 6E 30 125 4 1275 4.0 17"L x 18½"H x 7
IMPORTANT NOTES:
• Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to Model No. for 208V/1Ph.
• Models SUPER 1E-6E must use iTempo/Plus
• All MrSteam MS Models are cULus Listed and CE approved.
NOTES:
All MS Generators available in 240v/1PH, 208v/1PH and other voltages/phases. † Amps are for 240/1PH rated units. ‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors. Refer to the National Electrical Code for other types of conductors. See MrSteam® Installation and Operation Manual for complete dimensional and installation information. MS SUPER 4E includes two MS SUPER 1E steam generators, and require one iTempo/Plus steam generators, and require one iTempo/Plus iTempo/Plus
®
Control, and two matching steamheads.
®
control.
®
Control, and two matching steamheads. MS SUPER 6E includes two MS SUPER 3E steam generators, and require one
Amps (for Wire Total Adj. Water Usage Shipping
®
Control, and two matching steamheads. MS SUPER 5E includes two MS SUPER 2E
2
7
8"D 40
7
8"D x 2 80
*Dimensions are for generator only, without
AutoFlush® or plumbing features.
**Shipping weight and pricing are for generator only,
without control or steamhead.
†† Water usage based on 20 minutes of operation.
Page 5
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
BEFORE INSTALLING
Carefully inspect the Steam Generator and packaging for shipping damage. In the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with any missing or damaged parts.
Read these instructions before installation or service. Although this MS steambath generator has been fully quali­fied for shipment by MrSteam reviewed for proper, safe and enjoyable steam bathing:
1. Verify that the model and accessories specifications are correct for the incoming line voltage.
2. Insure steambath generator has been correctly sized for the steambath room. Pay particular attention to room vol-
®
, the following must be
STEAM ROOM GUIDELINES
1. Steam room must be completely enclosed, with full walls, door, floor and ceiling.
2. It is recommended that a gasketed door is used for steam containment.
WARNING
3. To prevent slip and fall hazards non-skip
!
strips must be installed on the steam room floor.
4. Check the suitability of any materials with the manufacturer. Walls and ceilings must be constructed of water-resistant, non-corrosive surface, such as tile, marble, molded acrylic, or other non-porous material.
5. The ceiling should be sloped to prevent dripping of condensate.
6. Provide a floor drain.
7. No heating, venting or air conditioning devices should be installed inside the steam room.
8. Steam room tile construction information is available from the Tile Council of America, Inc. by purchasing the TCA Handbook for Ceramic Tile Installation. Tel. (864) 646-8453 or www.tileusa.com.
9. Windows that are part of the steam room should be double paned and tempered safety glass.
10. Limit steam room ceiling height to 8 feet. Exceeding
8 feet may require a higher-rated steam generator.
ume and construction. If any questions, please refer to MrSteam sizing and selection guide on page 2.
3. Marble or glass walls or ceilings. “ENLARGE” the room’s size, requiring a generator larger than one based only on the room’s cubic foot (L x H x W) volume.
4. The physical size of the unit, clearance for plumbing servicing, and its distance from the steam room must all be considered before final installation.
5. Consider any controls and accessories before initiating installation. Read the Installation and Operation Manual of all controls and accessories available at www.mrsteam.com technical downloads.
6. Record the serial number of the steam generator in the space provided in the table of contents of this manual.
WARNING
!
manual provided with the steam bath generator is an essential part of providing a safe environment for steam room users. The peel and stick warning label must be applied to the wall of the shower or steam enclosure, at a point that is visible to all users. Failure to install this sticker may result in serious injury or death. The location where this owner's manual is kept shall be written in the space provided on the label using permanent ink. For a replacement warning label contact MrSteam customer service at 1-800-76-STEAM or hello@mrsteam.com
The peel and stick warning label located in the
Not Actual Size
I N S T A L L E R
WARNING
!
result in an inoperative or hazardous installation.
• Discontinue use of the steam generator and control if the steam generator or control are damaged or otherwise not functioning properly. Doing so may result in an inoperative or hazardous installation
• ELECTRICAL SHOCK HAZARD. MrSteam steam generators are connected to 240V line voltage and contain live electrical components. All installation and service to be performed by qualified and licensed electricians and plumbers only. Installation or service by unqualified persons or failure to use MrSteam parts may result in property damage or in a hazardous condition.
• The MS series of steam generators are for residential use only. Commercial or other nonresidential applications void the warran­ty and may adversely affect product performance and may repre­sent a safety hazard.
Never use damaged equipment, doing so may
CAUTION
!
materials are used as part of the steam room enclosure. Consult with the material manufacture and see pg. 7, “Installing the Steamhead" for additional details.
IMPORTANT NOTES:
This document contains important safety, operation and maintenance information. Leave this document with the homeowner. Do not discard this document.
The following general information should be used in conjunction with consultations with an architect, designer and contractor in determining factors necessary in providing a suitable and safe steam room.MrSteam steam generators are intended to be operated with MrSteam iSteam and iGenie®controls only, and are to be installed strictly in accor­dance with the specific instructions contained in this manual and as supplied in the manuals provided with the controls or accessories.
3
If acrylic, fiberglass or other non-heat resistant
®
, AirTempo®, iTempo/Plus®, iTempo®Home Wizard
®
Page 6
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
WATER QUALITY INFORMATION
I N S T A L L E R
For optimum results, the water supply should be tested prior
o installation. If the mineral content exceeds the following
t recommended limits, various external treatment processes are recommended to correct the problem.
NOTE: An analysis of the on-site water must be made by a recognized and reliable water treatment company to ascertain the existing condition and treatment required.
Poor water quality can affect efficiency or result in steam generator damage. Water contains impurities in solution and suspension. These impurities concentrate in the generator. The concentration of these impurities increases as more feedwater is introduced into the generator and steam is produced. If the suspended solids are allowed to concentrate beyond certain limits, a deposit or “scale” will form on the generator internal surfaces. This deposit can interfere with the proper generator operation and cause generator failure. The concentration of these impurities is generally controlled by the water quality and by periodic draining of the generator.
RECOMMENDED FEEDWATER QUALITY
Hardness, ppm 8 – 85 (~0.5 – 5 gpg) P-Alkalinity, ppm 85 – 410 (~5 – 24 gpg) T. Alkalinity, ppm 200 – 500 (~7 – 0 gpg) pH (strength of alkalinity) 8.0 – 11.4
Every 2 months, or more often in “hard” water areas, the manual drain valve should be opened fully flushing out accumulated materials, salts and other particles which are natural by-products of boiling water.
The optional AutoFlush System feature automatical­ly drains the MrSteam generator following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation.
LOCATING THE STEAM GENERATOR
Select a location as near as practical to the steam room. Typical locations include: closet, vanity cabinet,
heated attic or basement.
NOTE:
control must be located accordingly. A 60 foot cable is available as a special order part for iTempo PN 103990-60 and PN 104117-60 for iSteam
IMPORTANT NOTE: The control cable should be run in a dedicated 1" conduit to facilitate installation and service.
together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
The standard length of the cable for connecting the control to the steam generator is 30 feet. The steam generator and
®
.
The maximum cable length is 60 feet.
WARNING
!
DO NOT route iSteam, AirTempo, iTempo/Plus, iTempo, HomeWizard or iGenie control wiring inside conduit
®
and AirTempo®,
WARNINGS
!
1. DO NOT a shock hazard will occur.
2. DO NOT wherever environmental conditions may result in a shock hazard or affect performance of the generator.
3. To prevent damage to the steam generator or a fire hazard DO NOT flammable or corrosive materials or chemicals such as gasoline, paint thinners, or the like. Installation in areas having high concentrations of chlorine (such as pool equipment room) must be avoided.
4. Burn Hazard. Steam line, safety valve, drain valve and plumbing become hot during operation and remain hot after shutdown for a period of time. Provide appropriate protection, including insulating plumbing lines. Avoid plumbing runs and steamhead locations that can come in contact with bathers.
5. Suitable for operation in ambient not exceeding 45 °C (113˚ F). Operation of the steam generator in an ambient temperature above 45 *C (113 *F) may result in a hazardous condition or property damage
CAUTIONS
!
DO NOT
6. unheated attic or any locations where water could freeze and cause pipes to rupture and cause property damage.
(Items 1-5)
install steambath generator inside steam room,
install steambath generator outdoors or
install steambath generator near
(Items 6-8)
install steambath generator or plumbing lines, in
7. Install steambath generator on a solid and level surface. Keyhole slots are provided for wall mounting. Insure the steam generator is properly secured and level when mounting with keyhole slots to prevent damage to the steam generator.
8. Install steambath generator in an upright position only to prevent damage to the generator.
IMPORTANT NOTES: (Items 9-13)
9. Install anti-water hammer device as necessary.
10.Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing. See page 8.
11.
Provide unions as required to facilitate installation and disconnection of piping.
12
. MrSteam controls can be located inside the steam room
or on the outside of the steam room. See the Control Installation Manual for your specific control package for specific details.
13. The MS series of steam generators are for residential use only. Commercial or other nonresidential applications void the warranty and may adversely affect product performance and may represent a safety hazard.
NOTE:
MrSteam Generators (inclusive of the iTempo, AirTempo
and iSteam series controls) are CE and UL listed.
4
Page 7
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
TYPICAL MRSTEAM INSTALLATION
NOTE: Drawings for illustrative purposes only.
Consult with qualified designer, architect or contractor for steam room construction details.
Provide unions as required to facilitate installation and disconnect of piping
Field installed power supply
Steam Generator
Drain Valve must be closed
when the optional
AutoFlush is not installed
When installing the optional AromaSteam, install a down­ward facing 90-degree T in the steam supply line. See the AromaSteam Installation Manual for complete information.
Field installed water supply line
Field installed steam supply pipe
CAUTION
!
temperature sensor. Locate the control in a location representative of the desired steambathing temper­atures. Do not locate the control above or near the steam head or direct steam emissions.
Steam Head (shown with optional acrylic shield) See page 7 for Steam Head Installation information
CAUTION
!
where other controls, accessories, shower heads, valves, body sprays or similar within the shower could cause confusion or interfere with the MrSteam control’s intended use and function.
The control features an integral
Control cable run in 1” conduit (located
behind the wall)
To avoid unintentional steambath operation, do not locate the control
iSteam®, AirTempo or iTempo®Control
Refer to Control Installation Manual for installation information
®
I N S T A L L E R
TYPICAL INSTALLATION INSTRUCTIONS
FOR MODELS MS SUPER 4E, 5E & 6E
1. Install each steam generator as in a single installation. Install genera­tors as close as practical to each other, not exceeding 10 feet. The interconnecting cable length is 12 feet.
WARNING
2. Shock Hazard. Power must be disconnect-
!
ed at the main electrical supply. Remove steam gen­erator covers. Retain screws and covers for reuse.
3. Connect the iSteam
®
or AirTempo®control to either unit as per the Installation Manual supplied with each control.
4. Remove one knock-out on each generator as shown. Insert the ends of interconnecting cable provided (PN 103904) through the knock-outs as shown in diagram. Connect each end to the printed circuit board connector labeled "TANDEM" as shown.
5. Prevent the interconnecting cable from contacting hot surfaces such as steam outlet, safety valve and the like.
6. Connect separate plumbing and power supplies for each unit. Replace covers with cover screws.
7.
Provide unions as required to facilitate installation
and disconnection of piping
NOTE: The secondary unit will de-energize when the steam room reaches steambathing temperature resulting in a more gentle and energy efficient operation.
(shown with optional AutoFlush)
Power
Supply
Secondary Unit
5
Printed Circuit Board Component shown enlarged for illustrative purpose.
iSteam or
AirTempo
Primary Unit
Interconnecting Cable
Control
PN 103904
Optional AutoFlush Installation page 14
Water Feed Line
®
, see AutoFlush
All drawings are for illustrative purposes only
Control Cable
Steam Heads shown with optional acrylic shields
Page 8
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
INSTALLATION
I N S T A L L E R
PLUMBING
All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes.
1. Use unions on all pipe connections.
2. Use only brass piping or rigid copper tubing as permitted by codes.
3. DO NOT use black, galvanized, PVC pipe or PEX except as noted below.
WATER SUPPLY (3⁄8" NPT)
1. Connect to cold water line.
NOTE: Water feed line may be flexible copper tubing, braided hose, PVC or PEX if permissible by local codes.
2. Provide a shut off valve in the water supply line upstream of
the steambath generator.
3. DO NOT overheat inlet solenoid valve with solder connections.
Overheating will damage parts.
4. Flush inlet water line thoroughly before making connection
to unit.
5. Strainer recommended upstream of feed water connection.
6. In order to reduce operating noise, reducing feed water pres-
sure to between 15 - 20 psi is recommended. Optional pres­sure reducing valve part number 104198.
7. Provide anti-water hammer device as required.
8. Install an approved backflow preventer as required
by local codes.
DRAIN (1⁄2" NPT)
CAUTION
!
undersink trap, unless the generator is mounted higher than the sink to prevent damage to the generator if the drain backs up.
NOTE: A drain valve is provided to facilitate servicing. Provide a drain line connection from steambath generator drain valve according to National and local Codes. Check local plumbing code for receptor, trap and vent requirements. Do not connect Drain line and Safety Valve line together. Unit drains by gravity.
NOTE: Do not plumb the generator drain and drip pan drain together in such a way that will cause drain water to back into drip pan.
WARNING
!
location where accidental contact with drain water may occur. In the event of a power failure the AutoFlush System valve will open and may discharge boiling water causing a scalding hazard.
DO NOT connect the drain valve to the steam line
The drain from the generator should not share an
DO NOT drain into a steam enclosure or any
STEAM OUTLET (1⁄2" NPT)
1. DO NOT install any valve in steam line. Flow of steam must be unobstructed.
2. Use 1/2-inch brass pipe or copper tubing from unit to steam head as permitted by codes.
3. Insulate steam line with fiberglass pipe insulation or similar insulation rated 212° F or higher.
4. Pitch steam line 1/4" per foot towards steam head or steam generator to avoid valleys and trapping of condensate.
NOTE: Running the steam line down and then up will create a steam trap blocking the flow of steam.
NOTE: A 1.5" hole in the steam room is required to mount the steamhead.
SAFETY VALVE (3⁄4" NPT)
Where permitted by local codes, provide an outlet plumbing connection for safety valve.
WARNING
!
operation: DO NOT connect a shut off valve or a plug at safety valve outlet. DO NOT connect a shut off valve or any obstruc­tion in steam supply pipe. DO NOT connect the safety-valve output into the steam line.
To insure proper and automatic safety valve
DRIP PAN
MrSteam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Check local plumbing codes for receptor, trap and vent requirements. Drip pans drain by gravity. The drip pan is equipped with an integral3/4" fitting. See page 15 for additional drip pan installation information.
NOTE: Do not plumb the generator drain and drip pan drain together in such a way that will cause drain water to back into drip pan.
AROMASTEAM
If the optional AromaSteam Electronic Oil Delivery System
PN:MS AROMA
( fitting must be installed at a designated location on the steam outlet line. See the MrSteam AromaSteam Operation and Instruction Manual ( before the steam line is installed at the technical downloads section of www.mrsteam.com
) is to be installed, a 90 degree T plumbing
PN
: 100402) for installation information
6
Page 9
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
INSTALLING THE ROUND OR SQUARE AROMASTEAM STEAMHEAD
NOTE: A 1
needed to mount the steamhead.
STEP 1
Locate steam head 6-12 inches above floor, except for:
1. Tub/shower enclosures, install 6 inches above tub top edge.
2. For enclosures with acrylic or other non-heat resistant flooring install Acrylic Shield Part Number MS-103938.
3.To prevent door seals from deteriorating do not locate
the steam head where direct steam emission would contact door seals.
STEP 2
Install steamhead with the oil well facing up as shown. Hand tightening is sufficient when teflon or equal pipe thread sealing compound is used.
STEP 3
Secure a bronze drop ear fitting to a header and run a copper steam line from the steam generator to the drop ear fitting. Install a temporary nipple (6" or longer) in the drop ear fitting to locate the steamhead after the wall is finished.
STEP 4
After the wall has been finished, mark on the nipple where the surface of the wall is. Remove the nipple and measure the portion that was in the wall (the end to your mark). Subtract from that dimension and select a brass nipple of that length to finish the installation.
1
" clearance hole around the steam pipe is
2
(1⁄2" NPT)
1
"
2
1
4"
Use Teflon®or
equal sealant on
pipe threads
Apply with silicone or equal
sealant as required for
moisture seal.
Oil Well
Steam Supply Pipe
STEP 3
1/8" minimum clearance required when Acrylic Shield is used.
See installation instructions provided with the Acrylic Shield.
End of pipe to be recessed 1/4"
(without Acrylic Shield)
1/8" (with Acrylic Shield)
Drop Ear Fitting
I N S T A L L E R
STEP 5
Wrap teflon tape around the threads of the new nipple and screw the nipple into the steamhead. Do not use wrenches or tools which would damage the steamhead's finish.Wrap teflon tape around the threads of the nipple and screw the nipple and steamhead assem­bly you just made into the drop ear fitting in the wall. The steam­head should be flush with the wall and the well must be facing up.
__________________________________________________________
IMPORTANT NOTE: DO NOT disassemble steamhead. MrSteam’s steamhead is shipped fully assembled and requires no additional assembly.
To preserve steam head finish, DO NOT use wrench or other tools to tighten. DO NOT use abrasive cleansers or chemicals. Use only water with mild soap and a non-abrasive sponge.
CAUTION
!
Because the steam head and direct steam emissions are very hot, locate the steam head where incidental contact by bather with the steam head or direct steam emission cannot occur.
Consult with supplier of acrylic, fiberglass and other non-heat resistant enclosures for recommended steamhead location. Use Acrylic Shield PN MS-103938 (round) or PN MS-103938SQ (square). See instructions provided with steam shield.
STEP 4
STEP 5
Steamhead
(shown with optional acrylic shield
)
Locating Nipple
All drawings are for illustrative purposes only
7
Page 10
””
for servicing
D
I N S T A L L E R
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
GENERATOR DIAGRAM
Water Inlet
Control &
Accessory
Connections
team Outlet
S
Safety Valve
Optional AutoFlush
Manual Drain Valve
J
IMPORTANT NOTES:
Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing. Alternately, provide unions as required to facilitate installation and dis­connection of the steam generator.
The minimum clearance from combustible surfaces is zero all around.
Side View Showing Element Access Panel
TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS !!!
All drawings are for illustrative purposes only
MS 90E- MS 400E MS Super 1E-3E
_______________________________________
3
8” NPT
1
2” NPT
3
4” NPT
1
2” NPT
1
2” NPT
1
4 (184)
1
4 (57)
7
8 (124)
A
5 (127) 7
1
B
8
8 (206) 97⁄8 (251)
1
C
11
4 (392) 151⁄2 (394)
1
D
14
4 (392) 183⁄4 (476)
7
E
1
8 (48) 11⁄4 (32)
F
2 (51) 2
7
G
5
8 (149) 6 (152)
H
5 (127) 4
7
I
6
8 (175) 77⁄8 (200)
J
2 (51) 2 (51)
1
K
14
2 (368) 17 (432)
1
L
2
2 (64) 21⁄2 (64)
3
M
6
8 (162) 63⁄8 (162)
NOTES
:
1. M= Optional AutoFlush
2. All units in inches (MM)
3. MS Super 4E includes (2) MS Super 1E units
4. MS Super 5E includes (2) MS Super 2E units
5. MS Super 6E includes (2) MS Super 3E units
WATER INLET
STEAM OUTLET
SAFETY VALVE
MANUAL DRAIN VALVE
AUTOFLUSH VALVE
8
Page 11
Transformer
Liquid Level Control Board
Water Feed
Solenoid
Water Feed
Liquid
Level Probe
AutoFlush
®
Plug and
Play Connection
(see page 14)
Fuses
Contactor
Power Block
Power Supply
Knock-Out
Steam Outlet
Field
Wiring
Transformer
Liquid Level Control Board
Water Feed
Solenoid
Steam Outlet
Liquid
Level Probe
AutoFlush
®
Plug and
Play Connection
(see page 14)
Contactor
Power Supply
Knock-Out
Field
Wiring
Water Feed
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
EL E CT R IC A L C HA R T
ol Max Room Wire Size Wire Size
V
KW
Volts†Phase Amps
208 1 24 10 8
240 1 21 10 10
3 12 12 12
208 1 29 88
240 1 25 88
3 14 12 12
208 1 36 88
240 1 32 88
3 18 10 10
208 1 44 8 6
240 1 38 88
3 22 10 10
208 1 49 66
3 24 88
208 1 58 64
3 29 88
208 1 73 43
3 36 88
AWG)for 40˚ C (AWG) for 45˚ C
(
Ambient Ambient
ELECTRICAL
WARNING
!
a qualified licensed electrician in accordance with National Electrical Code and local electrical code.
POWER WIRING
See “Field Power Wiring” Diagrams (below)
1. Check power voltage. Use 240V rated unit when supply is greater than 208V. (Most homes have 240V, 1PH service). Use 208V rated unit for 208V power.
2. Use minimum 90˚ C/300V rated insulated copper conductors only, sized in accordance with National Electrical Code and local electrical code for the current in Ampere Chart. If allowed by codes, NM cable may require a larger wire size than as listed on the chart.
3. Connect suitably sized equipment grounding wire to ground terminal provided.
4. Install a separate circuit breaker between supply and unit. Provide a power supply disconnect within sight of the steam generator or one that is capable of being locked in the open position.
5.
For single phase units, use two-wire supply source and
equipment grounding wire. Neutral (white) wire is not required.
WARNING
!
All electrical wiring to be installed by
PROVIDE A POWER SUPPLY DISCONNECT WITHIN SIGHT OF THE STEAM GENERATOR OR ONE THAT IS CAPABLE OF BEING LOCKED IN THE OPEN POSITION AS REQUIRED BY CODE.
________________________________________________________________________________________________________
Model No.
________________________________________________________________________________________________________
MS-90E 100 5.0 3 14 12 12
_______________________________________________________________________________________________________
_
MS-150E 150 6.0 3 17 10 10
________________________________________________________________________________________________________
MS-225E 225 7.5 3 21 10 10
________________________________________________________________________________________________________
MS-400E 360 9.0 3 25 88
_______________________________________________________________________________________________________
_
MS-Super 475 10.0 3 28 88
________________________________________________________________________________________________________
MS-Super 575 12.0 3 34 88
_______________________________________________________________________________________________________
_
MS-Super 675 15.0 3 42 86
________________________________________________________________________________________________________
*See page 2 for room sizing.
All specifications shown are for 208V and 240V Consult factory for other voltage specifications.
(Cu. Ft.*)
1E 240 1 42 86
2E 240 1 50 66
3E 240 1 63 44
I N S T A L L E R
FIELD POWER WIRING
1. TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS!!!
2. L1, L2, Ground to be field wired
3. Super 1E 240/1 models are not supplied with internal fusing.
4. All Drawings are for illustrative purposes only. Consult with qualified licensed electrician for electrical installation.
Models MS 90E–MS 400E
(single phase wiring shown)
Models MS Super 1E-6E
(single phase wiring shown)
9
Page 12
FAC TOR Y WIR ING
FIE LD WIR ING
L E G EN D
(All Diagrams)
C
ONTACTOR
HEATING ELEMENT
TO PROBE
CONTROL BOARD
AutoFlush
S
teamGenie or
iGenie
(optional)
iSteam, AirTempo i
Tempo/Plus or
i
Tempo Control
T
RANSFORMER
P
OWER INPUT
GROUND
WATER
FEED
S
OLENOID
VALVE
CONTACTOR
HEATING ELEMENT
TO PROBE
CONTROL BOARD
AutoFlush
SteamGenie or iGenie
(optional)
iSteam, AirTempo iTempo/Plus or iTempo Control
TRANSFORMER
P
OWER INPUT
GROUND
W
ATER
F
EED
SOLENOID
VALVE
F
USES
POWER INPUT
TRANSFORMER
CONTROL BOARD
CONTACTOR
GROUND
HEATING ELEMENT
TO PROBE
WATER
FEED
SOLENOID
VALVE
AutoFlush
(optional)
SteamGenie or iGenie (optional)
iSteam, AirTempo iTempo/Plus or iTempo Control
I N S T A L L E R
mr.steam
Installation, Operation & Maintenance Manual
__________________________________________________________________________
SINGLE PHASE 208/240 VOLT WIRING DIAGRAMS
MODELS MS90E, MS150E, MS225E, MS400E
®
MODELS MS SUPER-1E, MS SUPER-2E, MS SUPER-3E
(Note: Super 1E 240V does not have fuses)
THREE PHASE 208/240 VOLT WIRING DIAGRAM
MODELS MS90E, MS150E, MS225E, MS400E, MS SUPER-1E, MS SUPER-2E, MS SUPER-3E
10
Page 13
AutoFlush
(optional)
iTempo/Start
(optional)
iSteam, AirTempo or iTempo/Plus
AutoFlush
(optional)
Do Not Connect Control
FAC TO RY WIR IN G
FIE LD WIR IN G
L E G EN D
(All Diagrams)
{
C
ONTACTOR
PRIMARY UNIT SECONDARY UNIT
AutoFlush
(optional)
Steam Genie
(optional)
iSteam, AirTempo or iTempo/Plus
AutoFlush
(optional)
PLUG THIS END TO MASTER UNIT
PRIMARY UNIT
SECOND UNIT
TO THIRD UNIT
TO FOURTH UNIT
TO FIFTH UNIT
Optional Tandem Cable for 2-5 Generators
Length is 30 ft. PN: 103917
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
INSTALLATION INSTRUCTIONS FOR MODELS: MS-SUPER 4E, MS-SUPER 5E AND MS-SUPER 6E
1.
Install each unit as in a single installation. Install the two generators as close to each other as possible.
2.
WARNING
!
steam generator covers.
3. Connect the iSteam
4. Remove one knock-out on each generator as shown. Insert the ends of interconnecting cable provided (PN 103904) through the knock-outs as shown in the Diagram on page 5. Connect each end to the printed circuit board as shown.
5. Connect separate plumbing and power supplies for each unit.
Wiring Diagram: MS-Super 4E, MS-Super 5E, MS-Super 6E
Shock Hazard.
®
, AirTempo®or iTempo/Plus®control to either generator per the control instructions..
Power must be disconnected at the main electrical supply before removing
I N S T A L L E R
OPTIONAL TANDEM CABLE
For connecting more than 2 steam generators in tandem
11
Page 14
I N S T A L L E R
1
2
4
7
8
9
3
6
5
Transformer
Liquid Level Control Board
Water Feed
Solenoid
Ste Ou
Liquid
Level Probe
AutoFlush and Play Connectio
Contactor
Power Supply Knock-Out
Field Wiring
Water Feed
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
INITIAL START-UP AND CHECKOUT
1. Turn on control. Follow specific instructions provided with controls.
2. Steam will begin to appear in approximately 5 minutes (unless equipped with factory-installed Express Steam option) at the steam head. Steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point.
3. Steam will shut off automatically when control counts down to zero. To shut steam off manually, turn control OFF. To clear steam from enclosure area, turn shower on before opening door.
4. If unit does not start and control does not turn ON (control display does not light up) then turn breaker off for 20 seconds and try again.
5. Check all internal and external plumbing fittings for leaks while the steam is on.
OPTIONAL & ACCESSORY EQUIPMENT
Refer to specific instruction manual for installation, operation and maintenance of optional equipment and accessories such as iSteam
®
, AirTempo®, iTempo/Plus®, iTempo®, Home Wizard®, iGenie®and MSTS.
TROUBLESHOOTING
IMPORTANT NOTE: The model and serial number is printed on
the data plate on the front of the steam bath generator.
Step 1 Check main incoming power to the unit.
Step 2 Ensure the black wires from the pri-
mary side of the transformer are connected to the quick connect tabs on the line side of the contactor.
Step 3 Verify that you have 24VAC coming out of the transformer, WHT & WHT/BLU wires, into the board.
Step 4 Verify that you have the green light on the PC board.
Step 5 Push the white test button to run the generator for 10 minute test cycle. Make sure the steam room is empty.
Step 6 Verify that you have 24 VAC to the water feed solenoid, GRY & WHT/GRY wires (will fill when needed).
Step 7 Temporarily short out the WLS (Purple wire) and GND (Green wire) ter­minals and verify the contactor engages.
Step 8 When the red light is on, verify 24 VAC, RED & WHT/RED wires, to the contactor.
WARNING
!
All electrical troubleshooting to be performed by a qualified licensed electrician
Step 9 Check main voltage on the
load side of the contactor when it is engaged.
Step 10 If all steps on the power path were verified, turn off power to the unit and pull the heating element via the left hand access panel for inspection.
DO NOT disassemble internal components, internal components contain no serviceable parts.
12
All drawings are for illustrative purposes only
Page 15
mr.steam
R
ED
(
H
eater)
Y
ELL
OW
(
Water Lev
el)
GR
EEN
(
Po
wer
)
Force On Test Button
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
SYSTEM STATUS CODES
The control (either iSteam®, AirTempo®, iTempo®or iTempo/Plus®) may display a status code if the steam generator is not functioning properly.
Code Code Meaning Probable Cause Suggested Remedy
H20 Water level is not Water Supply is off Turn on Water Supply
satisfied within 5 min.
Prr1 Temperature Probe Error Control cable/MSTS cable cut Replace control cable/MSTS or Prr2
Err1 Incorrect Field Supply Voltage Incorrect voltage supplied Supply steam generator with the correct
(green light on liquid level to Generator voltage noted on the data plate label. control board will be off)
Err2 Button on control is pressed Control cover misalignment Remove and reinstall control cover
for more than 5 minutes
Defective water feed solenoid Check/replace water solenoid valve
Water feed probe not functioning Check/clean probe.
Check probe wiring.
Drain Valve Open Check/Close drain valve
AutoFlush not functioning Check/Replace AutoFlush
Internal problem with control/MSTS Replace control / MSTS
Debris behind control cover Remove control cover and clean cover,
control and keypad with a damp cloth
I N S T A L L E R
Errb Water level not satisfied in a tandem set up - Check secondary generators, see H20.
Err7 Liquid Level Control Board malfunction Memory error in LLCB Press ON/OFF to clear.
Replace control if code remains.
LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators
______________________________________________________________________________________________________________________________________
GREEN LED is ON when there is 208/240 Volt incoming power connected,
______________________________________________________________________________________________________________________________________
YELLOW Water level indicator–LED is OFF when no water is detected (for more that 5 seconds). ON when
______________________________________________________________________________________________________________________________________
RED Contactor relay indicator–LED is ON when relay is closed and sending 24 Volts to the
______________________________________________________________________________________________________________________________________
FORCE ON Press this button to operate the generator. This button is for trouble shooting only and will operate TEST BUTTON
Liquid Level Control Board PN 103975
(shown without wiring)
24 Volt transformer secondary output and on-board 5 Volt DC control power are present.
water level is satisfactory. For units with AutoFlush, if more than five hours have elapsed since last usage and this LED is ON it is indicative of an AutoFlush or water level probe circuit malfunction.
contactor coil. (This LED comes ON if the generator is ON.)
if a control is connected or not. Pressing the button again will shut the generator OFF. The test button will only allow the generator to operate for 10 minutes.
All drawings are for illustrative purposes only
13
Page 16
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
OPTIONAL AUTOFLUSH
®
Box Contents
AutoFlush Valve with Cord Installation Instructions.
OPERATION
The optional AutoFlush System feature automatically drains the MrSteam generator following each use. A time delay allows the water to cool down (about two hours) before it
I N S T A L L E R
drains by gravity for a safe and gentle operation.
NOTE:
If the Express Steam®option has been installed, the AutoFlush will drain for ten minutes then refill with fresh water to begin the pre-heat cycle.
INSTALLATION INSTRUCTIONS
1. Plumbing to be performed by a qualified plumber and shall be in
accordance with applicable national and local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush must be available. The AutoFlush System valve outlet is Check plumbing code for receptor, trap and vent requirements.
2. Use copper or brass nipple
to connect AutoFlush valve (end "B") to the Drain Valve (valve end “A” and “B” are indicated on bottom of AutoFlush Valve)
1
2“ NPT x 31⁄2“ or longer (not supplied)
®
assembly
1
2“ NPT.
Steam Generator
Drain Valve
shown in the correct
( open position)
O NOT REMOVE
D
HIS DRAIN VALVE
T
3 Pin Connector for AutoFlush
AutoFlush Cord Connector
AutoFlush Cord
ipplecopper or brass
N
1
nipple
⁄2" NPT x 31⁄2" or
not supplied)
(
onger
l
End "B"
Arrow indicates correct direction of flow
E "A"
nd
AutoFlush
Valve
lumb to
P Drain Line
CAUTION
!
DO NOT REMOVE THE DRAIN VALVE Removal may cause equipment and property damage. If there is not enough room for the valve, an elbow and a short nipple (not provided) can be added.
3. Open Drain Valve (handle must be aligned with brass nipple).
4. Connect the AutoFlush System cord connector to the three pin
connector as shown.
WARNING
!
DO NOT drain into a steam enclosure or any location where accidental contact with drain water may occur. In the event of a power failure the AutoFlush System valve will open and may dis­charge boiling water causing a scalding hazard.
SWEAT FITTINGS
When using sweat fittings use only tin base solder with a melting point below 600 degrees F. DO NOT overheat. Ends of water supply tubing must be thoroughly clean for a minimum distance of 1" from ends. DO NOT remove valve cover.
TO CHECK OPERATION
1. Turn on MrSteam and allow tank to fill with water.
2. Turn off MrSteam control. Water should stay in tank.
3. Turn off power at the panel box. Water should
discharge from tank.
4. Turn on power at panel box.
5. Repeat
Steam Generator
Drain Valve
DO NOT TURN OR REMOVE
THE DRAIN VALVE
(shown in the correct open
position)
AutoFlush Shown Fully Assembled
AutoFlush Valve
Nipple
Plumb to Drain Line
CAUTION
!
PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL CODES. PLUMB AS REQUIRED FOR AUTOFLUSH SYSTEM.
All drawings are for illustrative purposes only
14
Page 17
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
OPTIONAL DRIP PAN
MrSteam strongly recommends the use of a drip pan
n the unlikely event of a plumbing leak.
i
Locate the drip pan on a solid level surface and place the steam generator inside the drip pan. Insure the steam generator is level (see page 4 for locating the steam generator).
All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes. Check local plumbing code for receptor, trap and vent requirements. Drip pans drain by gravity.
The drip pan is equipped with an integral female
3
4" NPT fitting.
NOTE: Do not plumb the generator drain and drip pan drain together in such a way that will cause drain water to back into drip pan.
I N S T A L L E R
OPTIONAL EXPRESS STEAM
(only available factory installed)
Available for all MS Models. Express Steam genera­tors are equipped with a low power heating element and thermostat to keep the water in the tank warm enough to bring up steam quicker. All Express Steam components and wiring are installed at the factory. No additional wiring or plumbing is required by installers.
®
All drawings are for illustrative purposes only
15
Page 18
Transformer
Liquid Level Control Board
Water Feed
Solenoid
Water Inlet
Safety Valve
AutoFlush
Valve
(optional)
Stainless Steel Tank
Heating Element
Express Steam
heater (optional)
Element
Access Cover
Liquid Level Probe
Plug and Play Connection
(see page 13)
Power Block
Power Supply
Knock-Out
Contactor
Steam Outlet
Fuses
Nipple
(not included)
Manual Drain Valve
Transformer
D
rain Line
Nipple
(not included)
L
iquid Level
C
ontrol Board
W
ater Feed
S
olenoid
Water Inlet
S
afety Valve
AutoFlush
Valve
(optional)
Stainless Steel Tank
H
eating Element
Access Cover
Liquid Level Probe
P
lug and Play
C
onnection (see page 13)
C
ontactor
Power Supply
Knock-Out
S
team Outlet
Express Steam
H
eater (optional)
Manual D
rain Valve
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
PARTS IDENTIFICATION DIAGRAMS
MS REGULAR MODELS MS65E - MS400E
(with AutoFlush®) shown with cover removed
I N S T A L L E R
NOTE: FOR ILLUSTRATIVE PURPOSES ONLY.
Some components may be omitted or altered for clarity. DO NOT use for wiring, repair or other purposes not related to
component identification.
MS SUPER MODELS - MS SUPER 1E- MS SUPER 6E
(with AutoFlush®)
shown with cover removed
NOTE: Super 1E 240/1 models are not supplied with internal fusing.
NOTE: FOR ILLUSTRATIVE PURPOSES ONLY.
Some components may be omitted or altered for clarity. DO NOT use for wiring, repair or other purposes not related to
component identification.
16
Page 19
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
REPLACEMENT PARTS LIST
_________________________________________________________________________________________________
Part No. Description Generator
_________________________________________________________________________________________________
99178MS Drain Valve All Models 99297 Safety Valve 15PSI All Models 100479 Water Feed Solenoid Valve w/filter All Models 10477-3 Transformer 24VAC All Models 103975 Liquid Level Control Board All Models 103904 Tandem Cable for 2 generators (12 ft.) All Models 103917 Tandem Cable for up to 5 generators (30 ft.) All Models 103990-60 Cable for iTempo®Control (60 ft.) All Models 104117-30 Cable for iSteam®, AirTempo®and iTempo (30 ft.) All Models 104117-60 Cable for iSteam (60 ft) All models MSTS Remote Temperature Probe All Models
for iTempo/Plus and AirTempo iMSTS Remote Temperature probe for iSteam All Models 100476-2 Contactor 50A 2-pole MS 90E-400E, Single phase 99012 Contactor 50A 3-pole All 3-Phase Models 103453 Contactor 50A 4-pole MS Super-1E – Super-6E 100471-2 Probe Assembly All Models 99096MS Heating Element Gasket All Models 103938 Round Acrylic Shield iTempo & iTempo/Plus All Models 103938 Square Acrylic Shield iTempo & iTempo/Plus All Models 99314 Power Fuse 60A 250V MS-Super 1E–6E Single phase 29051BMS Heating Element 5 KW 208V MS 90E 29051CMS Heating Element 5 KW 240V MS 90E 29061BMS Heating Element 6 KW 208V MS 150E 29061CMS Heating Element 6 KW 240V MS 150E 29071BMS Heating Element 7.5 KW 208V MS 225E 29071CMS Heating Element 7.5 KW 240V MS 225E 29091BMS Heating Element 9 KW 208V MS 400E 29091CMS Heating Element 9 KW 240V MS 400E 29101BMS Heating Element 10 KW 208V MS SUPER-1E & MS Super-4E 29101CMS Heating Element 10 KW 240V MS SUPER-1E & MS Super-4E 29121BMS Heating Element 12 KW 208V MS SUPER-2E & MS Super-5E 29121CMS Heating Element 12 KW 240V MS SUPER-2E & MS Super-5E 29151BMS Heating Element 15 KW 208V MS SUPER-3E & MS Super-6E 29151CMS Heating Element 15 KW 240V MS SUPER-3E & MS Super-6E 104058 iGenie All Models 104059 iGenie Interface Module All Models 104060 iGenie Interface Cable (5 ft.) All Models
I N S T A L L E R
17
Page 20
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
CONTROL INSTALLATION
Refer to Control Manual for specific installation requirements
BEFORE INSTALLING
Turn power to the steam generator OFF before connecting the control to the generator. Failure to turn the power off will result in an inoperable control.
CAUTION
!
DO NOT locate the control where other controls, acces-
I N S T A L L E R
sories, shower heads, valves, body sprays or similar within the shower could cause confusion or interfere with the MrSteam control’s intended use and function.
CAUTION
!
iTempo/Plus without reading and understanding its own manual and the MrSteam steam generator Installation and Operation Manual. Failure to read and understand these instructions may result in an inoperative or hazardous installation.
WARNING
!
and permanently affixed in a conspicuous location near the steam room. Failure to read and affix this warning sticker in a conspicuous location may result in serious injury or death. .
Install the iSteam, AirTempo, iTempo or iTempo/Plus controls according to installation instructions. Failure to install accord­ing to instructions will result in an inoperative control or haz­ardous overheating or inadequate heating of the steam room.
If an iSteam, AirTempo, iTempo or iTempo/Plus control is installed outside the steam room a Remote Temperature Probe (PN MSTS or iMSTS) must be installed inside the steam room per installation instructions supplied with the Remote Temperature Probe. Failure to install according to instructions will result in an inoperative control and overheat­ing of the steam room.
o avoid unintentional steambath operation,
T
DO NOT use any iSteam
®
, iTempo®, HomeWizard®or iGenie®controls
A peel and stick warning sticker must be read
®
, AirTempo®,
WARNING
!
iTempo, HomeWizard or iGenie control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
DO NOT alter or modify any MrSteam product. Doing so may result in an inoperative or hazardous installation and will void the UL listing and warranty.
IMPORTANT NOTES:
1. Turn power to the steam generator OFF before connect­ing the control to the generator. Failure to turn the power off will result in an inoperable control.
2. DO NOT operate iSteam, AirTempo,iTempo/Plus, iTempo, HomeWizard or iGenie controls with other than a MrSteam iSteam, AirTempo, or iTempo compatible steam generator. MrSteam residential steam generators with serial numbers lower than 900000, or any other brand of steam generator are not to be operated with iTempo controls. Doing so may result in an inoperative or hazardous installation. If iSteam is used with a generator having serial number 900000 through 930030, contact MrSteam technical sup­port for an upgraded PC board.
3. This document contains important safety, operation and maintenance information. Leave this document with the homeowner. Do not discard this document.
4. Discontinue use of the steam generator or control if the steam generator is damaged or otherwise not functioning properly. Operating a damaged steam generator may result in an inoperative or hazardous installation
DO NOT route iSteam,
AirTempo,
iTempo/Plus,
CONTROL ROUGH IN
Refer to Installation Instructions for the specific control
IMPORTANT NOTE: The control cable should be run in a dedicated 1” conduit to facilitate installation and service.
1.
Determine the desired installation location of the con­trol. The iSteam controls are designed to be installed inside or outside the steam room as a matter of personal preference. If the con­trol is in-stalled inside the steam room the control must be located:
2. 4-5 feet above the floor near the bather seating area
3. The control features an integral temperature sensor.
Locate the control in a location representative of the desired steambathing temperatures.DO NOT locate the control above or near the steam head or direct steam emissions.
4. on a vertical wall
The iSteam and iTempo control cable length is 30 feet. Insure that the control and/or steam generator are locat­ed accordingly. An optional 60 foot cable is available, PN
®
,
AirTempo®,
iTempo®and iTempo/Plus
103990-60 for AirTempo and iTempo and PN 104117-60 for iSteam. Contact a MrSteam technical service representative if a 60 foot cable is required. Excess control cable should be neatly coiled and twisted into a figure 8. The AirTempo dongle
®
is provided with a 3 foot cable. The maximum cable length is 60 feet.
IMPORTANT NOTES:
• If the control is installed outside the steam room a Remote Temperature Probe Part Number MSTS or iMSTS must be installed inside the steam room, depending on the control.
• Insure MrSteam steam generator is iSteam, AirTempo or iTempo compatible and has a serial number 900000 or high­er. If iSteam is used with a generator having serial number 900000 through 930030, contact MrSteam technical support for an upgraded PC board.
See instructions for the MSTS or iMSTS Temperature Probe (located in the Control Installation Manual related to your spe­cific control package) before rough-in or installation of control.
18
Page 21
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
H O M E O W N E R S E C T I O N
RE A D M E FI R ST !
WARNING
!
instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of this generator. These are types of potential hazards that may occur during installation and operation:
WARNING
!
hazardous situation, which, if not avoid­ed, could result in death or serious injury.
CAUTION
!
hazardous situation, which, if not avoid­ed may result in minor or moderate injury or product damage.
IMPORTANT NOTE:
highlights information that is especially relevant to a problem-free installation.
All information in these instructions is based on the latest product information available at the time of publication. Sussman-Automatic Corporation reserves the right to make changes at any time without notice.
As you follow these
Indicates a potentially
Indicates a potentially
This
When using this steam bath equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS
WARNING
2.
!
WARNING
3.
!
injury or death if improperly used. Steam rooms contain steam and elevated tempera­tures. Please read and observe all warnings in this manual before installing or using a steam room.
WARNING
4.
!
A. The wet surfaces of steam enclosures
may be slippery. Use care when entering or leaving.
B. The steam head is hot. DO NOT touch the
steam head and avoid the steam near the steam head.
C. Prolonged use of the steam system can raise
excessively the internal human body tempera­ture and impair the body’s ability to regulate its internal temperature (hyperthermia). Limit your use of steam to 10-15 minutes until you are certain of your body’s reaction.
D. Excessive temperatures have a high potential
Supervise children at all times..
Steam is hot and can cause
To reduce the risk of injury:
for causing fetal damage during the early months of pregnancy. Pregnancy or possibly pregnant women should consult a physician regarding correct exposure.
E. Obese persons and persons with a his-
tory of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steambath.
F. Persons using medication should con-
sult a physician before using a steam­bath since some medication may induce drowsiness while other med­ications may affect heart rate, blood pressure and circulation.
SAVE THESE
INSTRUCTIONS
HYPERTHERMIA
nal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The symp­toms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and faint­ing. The effects of hyperthermia include:
a) Failure to perceive heat; b) Failure to recognize the need to exit
the steambath; c) Unawareness of impending risk; d) Fetal damage in pregnant women; e) Physical inability to exit the steambath
and
f) Unconsciousness
WARNING
!
drugs, or medication can greatly increase the risk of hyperthermia.
occurs when the inter-
.
The use of alcohol,
WARNING
!
stick warning label located in the manual provided with the steam bath generator is an essential part of providing a safe environment for steam room users. The peel and stick warning label must be applied to the wall of the shower or steam enclosure, at a point that is visible to all users. Failure to install this sticker may result in serious injury or death.
The location where this owner's manual is kept shall be written in the space provided on the label using permanent ink.
For a replacement warning label contact MrSteam customer service at 1-800-76-STEAM or hello@mrsteam.com
The peel and
19
Not Actual Size
Page 22
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
H O M E O W N E R
SETTING THE STEAM BATH TEMPERATURE AND DURATION
WARNING
!
ing to personal preference, however it is highly recom­mended to begin steam bathing at a low temperature set-
ing to gauge comfort and safety levels. Set duration to a
t maximum of 10 minutes to gauge comfort and safety lev­els. This will allow the steam generator to heat up and begin producing steam.
Set the steam bathing temperature accord-
SAFETY AND OPERATING INFORMATION
WARNING
!
AirTempo
®
iGenie MrSteam steam generator Installation and Operation Manual. Failure to read and understand these instructions may result in an inoperative or hazardous installation.
WARNING
!
the manual provided with the steam bath generator must be read and permanently affixed in a conspicuous location near the steam room. Failure to read and affix this warning sticker in a conspicuous location may result in serious injury or death.
If an iSteam, AirTempo, iTempo or iTempo/Plus control is installed outside the steam room a Remote Temperature Probe (PN MSTS or iMSTS) must be installed inside the steam room per installation instructions supplied with the Remote Temperature Probe. Failure to install according to instructions will result in an inoperative control and overheating of the steam room.
WARNING
!
strips must be installed on the steam room floor.
DO NOT install or use any iSteam®,
®
, iTempo/Plus®, iTempo®, HomeWizard®or
controls without reading and understanding the
The peel and stick warning label located in
To prevent slip and fall hazards non-skip
CARE TIPS FOR ALL CONTROLS AND STEAMHEADS
1. Use only mild soap and water on a soft cloth to clean the control and steamhead.
2. DO NOT use abrasive cleansers.
3. If the decorative cover is damaged on the iTempo
r iTempo/Plus call MrSteam technical service for
o
replacement parts.
NOTE: Replacement of the decorative covers requires removal and reinstallation of the control from the mounting surfaces.
STEAM GENERATOR MAINTENANCE
MrSteam steambath generators require little maintenance. Other than periodic draining, maintenance procedures are mini­mal. Every 2 months, or more often in “hard” water areas, the manual drain valve should be opened fully flushing out accumu­lated materials, salts and other particles which are natural by­products of boiling water.
CAUTION
!
trol has been turned off to insure that the water has cooled.
WARNING
!
expose PVC and other piping to high temperature water. Check local codes. The unit will refill automatically when the control is activated again. In areas of hard water, a MrSteam AutoFlush system is recommended for generator longevity.
WARNING
!
equipment and user to scalding water and cause property and personal injury.
IMPORTANT NOTE: The model and serial number is printed on the data plate on the front of the steam bath generator.
Flush a minimum of two-three hours after the con-
Draining immediately after a steam cycle may
®
Failure to allow the water to cool will expose the
WARNING
!
product. Doing so may result in an inoperative or hazardous installation and will void the UL listing and warranty.
IMPORTANT NOTES:
lightning, fire, freezing or flooding is not covered under the warranty.
Discontinue use of the steam generator or control if the steam generator is damaged or otherwise not functioning properly. Doing so may result in an inoperative or hazardous condition.
DO NOT alter or modify any MrSteam
Malfunction due to power spikes,
20
Page 23
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
USING MRSTEAM®ESSENTIAL OILS
Enjoy AromaSteam essential oils by placing a drop or two
into an unheated AromaSteam steamhead as shown in the illustration. Only use MrSteam AromaSteam essential oils in
he MrSteam AromaSteam steamhead.
t
AromaSteam 10ml bottle with integrated dropper
WARNING
!
cause inflammation, burns, headache, nausea and allergic reactions. Consult a physician before using aroma therapy.
CAUTIONS
!
1. Use essential oils with caution. Essential oils are for exter­nal use only. Keep out of reach of children. Essential oils are highly concentrated and are potent substances and should not be applied directly to the skin as they can be irritants. Use essential oils with caution.
Place the drops into the MrSteam AromaSteam steamhead
2. recess prior to turning on the steambath. DO NOT place drops in a hot steam head as serous injury can result if you do not follow this warning.
3. Start with one drop to gauge strength and suitability. Limit to a maximum of a few drops for a steambathing session.
4. The bather should exit the steambath IMMEDIATELY if dizziness occurs. If skin irritation occurs stop using the oils immediately. Remove any excess oil by washing in mild soap and water. If ingested, rinse mouth with water. Administer water or milk to dilute. Contact a physician immediately.
CAUTION
!
turning on the steambath unit. DO NOT add oil
before during steambathing or when the steam head is heated.
Essential oils and/or aroma therapy can
Aromatic oils should be added to steamhead
Recess for essential oil
Steam emission slot
AromaSteam steamhead (install per instructions on pg.7)
H O M E O W N E R
Tightly close bottles when storing oils. Keep bottles away from sources of ignition.
All drawings are for illustrative purposes only
WARRANTY
To view or download the MrSteam Residential Generator Warranty and register your Product go to:
blog.mrsteam.com/wr
21
Page 24
®
mr
steam
.
®
Feel Good Inc.
www.mrsteam.com
Products, information and specifications are subject to change without notice.
Please call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information.
mr.steam
43-20 34th Street, Long Island City, NY 11101
TEL: 1 800 76 STEAM FAX: 718 472 3256
2018 © Sussman-Automatic Corporation I MrSteam and des., A Lifetime of Pleasure, AirTempo, AromaFlo, AudioWizard, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean Steam...Every Time, Club Therapy, CT Day Spa, Digital 1, Express Steam, Feel Good Inc., From Bathroom to Spa, HomeWizard, iButler, iGenie, iSpa Package, iSteam, iTempo, iTempo/Plus, Linear Steamhead, Making Wellness a Way of Life, Music Therapy, My Steam, SmartSizing, Spa Package, Steam Genie, Steam on Demand, Steam in a Box, Steam@Home, SteamStart, SteamTherapy, Sussman, Tala, Tala Bath & Body, Tempo, The Intelligent Steambath, Valet Package, and Virtual Spa System are registered trademarks of Sussman-Automatic Corporation.
®
Sussman-Automatic Corporation
®
hello@mrsteam.comIwww.mrsteam.com
I
9410 S. La Cienega Blvd. Inglewood CA 90301
TEL: 1 800 72 STEAM FAX: 310 216 2944
PUR 100472A 8.18
Loading...