Mr Steam MS90E, MS150E, MS225E, MS400E, MS SUPER 1E User Manual

...
Installation, Operation and Maintenance Manual
Steambath Generator Systems
Residential
Models: MS90E – MS400E and MSSUPER1E – 6E
____________________
IMPORTANT:
Leave this material with the home owner.
____________________
mr.steam
®
®
Feel Good Inc.
CAUTION
!
installation, operation and maintenance manual supplied with the product must be used for installation, operation and maintenance purposes. Failure to use the installation, operation and maintenance manual supplied with the product may result in a property damage or personal injury.
This installation, operation and maintenance manual is for general reference. The
EA D M E F IRS T!
R
WARNING
!
instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installa­tion and operation of this generator. These are types of potential hazards that may occur during installation and operation:
WARNING
!
hazardous situation, which, if not avoided, could result in death or serious injury.
CAUTION
!
ardous situation, which, if not avoided may result in minor or moderate injury or product damage.
IMPORTANT NOTE:
information that is especially relevant to a problem­free installation.
ll information in these instructions is based on
A
he latest product information available at the
t time of publication. Sussman-Automatic Corporation reserves the right to make changes at any time without notice.
As you follow these
Indicates a potentially
Indicates a potentially haz-
his highlights
T
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
.
1
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
2.
!
WARNING
3.
!
injury or death if improperly used. Steam rooms contain steam and elevated temperatures. Please read and observe all warnings in this manual before installing or using a steam room.
WARNING
4.
!
A. The wet surfaces of steam enclosures
may be slippery. Use care when entering or leaving.
B. The steam head is hot. DO NOT touch the
steam head and avoid the steam near the steam head.
C. Prolonged use of the steam system can raise
excessively the internal human body temper­ature and impair the body’s ability to regu­late its internal temperature (hyperthermia). Limit your use of steam to 10-15 minutes until you are certain of your body’s reaction.
Supervise children at all times
Steam is hot and can cause
To reduce the risk of injury:
D. Excessive temperatures have a high
potential for causing fetal damage dur­ing the early months of pregnancy. Pregnancy or possibly pregnant women should consult a physician regarding correct exposure.
E. Obese persons and persons with a his-
tory of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steambath.
F. Persons using medication should con-
sult a physician before using a steam­bath since some medication may induce drowsiness while other medica­tions may affect heart rate, blood pres­sure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
WARNING
!
Not Actual Size
The use of alcohol, drugs, or medication can greatly increase the risk of hyperthermia.
The manual supplied with the generator includes a peel and stick warning label. Its proper use is an essential part of providing a safe environment for steam room users. The peel and stick warning label must be applied to the wall of the shower or steam enclosure, at a point that is visible to all users. Failure to install this sticker may result in serious injury or death. The location where this owner's manual is kept shall be written in the space provided on the label using permanent ink. For a replacement warning label contact MrSteam customer service at 1-800-76-STEAM or hello@mrsteam.com.
a) Failure to perceive heat; b) Failure to recognize the need to exit the steambath; c) Unawareness of impending risk; d) Fetal damage in pregnant women; e) Physical inability to exit the steambath; and f) Unconsciousness.
Designed, Engineered and Assembled in the
# # # #
USA
mr.steam
43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM FAX: 718 472 3256
9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 1 800 72 STEAM FAX: 310 216 2944
®
Sussman-Automatic Corporation®hello@mrsteam.com www.mrsteam.com
PUR 100472A Rev 8.18
RESIDENTIAL STEAMBATH GENERATOR SYSTEMS
INSTALLATION, OPERATION & MAINTENANCE MANUAL
MODEL _______________________________
MODELS: MS-90E, MS-150E, MS-225E, MS-400E, MS-SUPER 1E,
S-SUPER 2E, MS-SUPER 3E, MS-SUPER 4E, MS-SUPER 5E, MS-SUPER 6E
M
TABLE OF CONTENTS
Important Safety Instructions . . . . . . . . . . . . . Inside front cover
Select Your MrSteam Model . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Generator Specification Chart . . . . . . . . . . . . . . . . . . . . . . . . . 2
_______________________________________________________________________
INSTALLER SECTION
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Steam Room Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Water Quality Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Locating the Steam Generator . . . . . . . . . . . . . . . . . . . . . . . 4
Typical Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . 5
Installation: Plumbing, Water Supply, Drain, Steam Outlet
Safety Valve, Drip Pan, AromaSteam . . . . . . . . . . 6
Steam Head Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Steam Generator Dimensions . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Specifications & Field Power Wiring . . . . . . . . . . . 9
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
Optional Tandem Cable Diagram . . . . . . . . . . . . . . . . . . . . 11
Initial Start-Up & Checkout . . . . . . . . . . . . . . . . . . . . . . . . . 12
Optional & Accessary Equipment . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
System Status Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Liquid Level Control Board . . . . . . . . . . . . . . . . . . . . . . . . . 13
Optional AutoFlush System . . . . . . . . . . . . . . . . . . . . . . . . . 14
Optional Drip Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Optional Express Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Parts Identification Diagrams. . . . . . . . . . . . . . . . . . . . . . . . 16
Replacement Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
CONTROL INSTALLATION
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Control Rough-In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
_______________________________________________________________________
SERIAL NO. ___________________________
HOMEOWNER SECTION
Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . 19
Setting Steam Bath Temperature & Duration . . . . . . . . . . . 20
Safety & Operating Info. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Care Tips for Controls and Generator Maintenance . . . . . . 20
Using the AromaSteam Essential Oils . . . . . . . . . . . . . . . . . 21
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
®
mr.steam
Feel Good Inc.
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
SELECT YOUR MrSteam
MrSteam @ Your Fingertips:
Start working smarter with MrSteam’s mobile sizing app, now available for the iPad
Visit mrsteam.com to size your generator automatically or go directly to: http://isizing.mrsteam.com
Materials of construction, room size and special design features such
s large glass areas, all affect
a
1.
Measure length, width & height in feet of the steam/shower or tub/shower
Multiply the Length ____ x Width_____ x Height _____ =
2.
Construction Materials:
For natural stones: natural marble, Add 110% stone, shale, glass block or concrete
For ceramic or porcelain tile on Add 40% cement board or mortar bed
3.
Ceiling Height: For each foot above 8 feet Add 15%
4. Add all figures above to obtain the Total Room Volume required
Compare your Room Volume to the Chart below
®
, iPod®and most smart phones.
he steam generator model selection.
t
and select the appropriate model.
ROOM VOLUME
WARNING
!
se of this steambath system, please note that if
u
In considering the purchase or
you are pregnant, have a coronary condition, are in poor health, are being treated for any other medical condition, or are using medication or drugs, MrSteam recommends that you obtain the approval of a physician before use. For information about this product and safety issues, please call 1.800.76.STEAM
IMPORTANT NOTES:
or steam rooms constructed of acrylic or
F synthetic materials, select next lower-rated MS model.
The MrSteam Sizing Chart allows for up to 60 feet of insulated steam line from the MS generator to the steam room. If the 60 foot line is exceeded consult with factory. The steam generator control locations must be taken into account. A 30 foot cable is standard. Contact MrSteam to purchase an optional 60 ft. cable PN 103990-60 for
®
iTempo iSteam
and AirTempo®and PN 104117-60 for
®
. The maximum cable length is 60 feet.
R E S I D E N T I A L S T E A M G E N E R AT O R S S P E C I F I C A T I O N C H A R T
Model No. KW 240v/1PH)† Size‡ Room Vol. Gallons†† Dimensions* Wt. (lbs)**
MS90E 5 21 10 100 0.67 14½"L x 14¾"H x 6¾"D 30
MS150E 6 25 8 150 0.80 14½"L x 14¾"H x 6¾"D 30
MS225E 7.5 32 8 225 1.0 14½"L x 14¾"H x 6¾"D 30
MS400E 9 38 8 360 1.2 14½"L x 14¾"H x 6¾"D 30
MS SUPER 1E 10 42 8 475 1.4 17"L x 18½"H x 77⁄8"D 40
MS SUPER 2E 12 50 6 575 1.6 17"L x 18½"H x 77⁄8"D 40
MS SUPER 3E 15 63 4 675 2.0 17"L x 18½"H x 7
MS SUPER 4E 20 84 8 875 2.7 17"L x 18½"H x 77⁄8"D x 2 80
MS SUPER 5E 24 100 6 1075 3.2 17"L x 18½"H x 77⁄8"D x 2 80
MS SUPER 6E 30 125 4 1275 4.0 17"L x 18½"H x 7
IMPORTANT NOTES:
• Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to Model No. for 208V/1Ph.
• Models SUPER 1E-6E must use iTempo/Plus
• All MrSteam MS Models are cULus Listed and CE approved.
NOTES:
All MS Generators available in 240v/1PH, 208v/1PH and other voltages/phases. † Amps are for 240/1PH rated units. ‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors. Refer to the National Electrical Code for other types of conductors. See MrSteam® Installation and Operation Manual for complete dimensional and installation information. MS SUPER 4E includes two MS SUPER 1E steam generators, and require one iTempo/Plus steam generators, and require one iTempo/Plus iTempo/Plus
®
Control, and two matching steamheads.
®
control.
®
Control, and two matching steamheads. MS SUPER 6E includes two MS SUPER 3E steam generators, and require one
Amps (for Wire Total Adj. Water Usage Shipping
®
Control, and two matching steamheads. MS SUPER 5E includes two MS SUPER 2E
2
7
8"D 40
7
8"D x 2 80
*Dimensions are for generator only, without
AutoFlush® or plumbing features.
**Shipping weight and pricing are for generator only,
without control or steamhead.
†† Water usage based on 20 minutes of operation.
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
BEFORE INSTALLING
Carefully inspect the Steam Generator and packaging for shipping damage. In the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with any missing or damaged parts.
Read these instructions before installation or service. Although this MS steambath generator has been fully quali­fied for shipment by MrSteam reviewed for proper, safe and enjoyable steam bathing:
1. Verify that the model and accessories specifications are correct for the incoming line voltage.
2. Insure steambath generator has been correctly sized for the steambath room. Pay particular attention to room vol-
®
, the following must be
STEAM ROOM GUIDELINES
1. Steam room must be completely enclosed, with full walls, door, floor and ceiling.
2. It is recommended that a gasketed door is used for steam containment.
WARNING
3. To prevent slip and fall hazards non-skip
!
strips must be installed on the steam room floor.
4. Check the suitability of any materials with the manufacturer. Walls and ceilings must be constructed of water-resistant, non-corrosive surface, such as tile, marble, molded acrylic, or other non-porous material.
5. The ceiling should be sloped to prevent dripping of condensate.
6. Provide a floor drain.
7. No heating, venting or air conditioning devices should be installed inside the steam room.
8. Steam room tile construction information is available from the Tile Council of America, Inc. by purchasing the TCA Handbook for Ceramic Tile Installation. Tel. (864) 646-8453 or www.tileusa.com.
9. Windows that are part of the steam room should be double paned and tempered safety glass.
10. Limit steam room ceiling height to 8 feet. Exceeding
8 feet may require a higher-rated steam generator.
ume and construction. If any questions, please refer to MrSteam sizing and selection guide on page 2.
3. Marble or glass walls or ceilings. “ENLARGE” the room’s size, requiring a generator larger than one based only on the room’s cubic foot (L x H x W) volume.
4. The physical size of the unit, clearance for plumbing servicing, and its distance from the steam room must all be considered before final installation.
5. Consider any controls and accessories before initiating installation. Read the Installation and Operation Manual of all controls and accessories available at www.mrsteam.com technical downloads.
6. Record the serial number of the steam generator in the space provided in the table of contents of this manual.
WARNING
!
manual provided with the steam bath generator is an essential part of providing a safe environment for steam room users. The peel and stick warning label must be applied to the wall of the shower or steam enclosure, at a point that is visible to all users. Failure to install this sticker may result in serious injury or death. The location where this owner's manual is kept shall be written in the space provided on the label using permanent ink. For a replacement warning label contact MrSteam customer service at 1-800-76-STEAM or hello@mrsteam.com
The peel and stick warning label located in the
Not Actual Size
I N S T A L L E R
WARNING
!
result in an inoperative or hazardous installation.
• Discontinue use of the steam generator and control if the steam generator or control are damaged or otherwise not functioning properly. Doing so may result in an inoperative or hazardous installation
• ELECTRICAL SHOCK HAZARD. MrSteam steam generators are connected to 240V line voltage and contain live electrical components. All installation and service to be performed by qualified and licensed electricians and plumbers only. Installation or service by unqualified persons or failure to use MrSteam parts may result in property damage or in a hazardous condition.
• The MS series of steam generators are for residential use only. Commercial or other nonresidential applications void the warran­ty and may adversely affect product performance and may repre­sent a safety hazard.
Never use damaged equipment, doing so may
CAUTION
!
materials are used as part of the steam room enclosure. Consult with the material manufacture and see pg. 7, “Installing the Steamhead" for additional details.
IMPORTANT NOTES:
This document contains important safety, operation and maintenance information. Leave this document with the homeowner. Do not discard this document.
The following general information should be used in conjunction with consultations with an architect, designer and contractor in determining factors necessary in providing a suitable and safe steam room.MrSteam steam generators are intended to be operated with MrSteam iSteam and iGenie®controls only, and are to be installed strictly in accor­dance with the specific instructions contained in this manual and as supplied in the manuals provided with the controls or accessories.
3
If acrylic, fiberglass or other non-heat resistant
®
, AirTempo®, iTempo/Plus®, iTempo®Home Wizard
®
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
WATER QUALITY INFORMATION
I N S T A L L E R
For optimum results, the water supply should be tested prior
o installation. If the mineral content exceeds the following
t recommended limits, various external treatment processes are recommended to correct the problem.
NOTE: An analysis of the on-site water must be made by a recognized and reliable water treatment company to ascertain the existing condition and treatment required.
Poor water quality can affect efficiency or result in steam generator damage. Water contains impurities in solution and suspension. These impurities concentrate in the generator. The concentration of these impurities increases as more feedwater is introduced into the generator and steam is produced. If the suspended solids are allowed to concentrate beyond certain limits, a deposit or “scale” will form on the generator internal surfaces. This deposit can interfere with the proper generator operation and cause generator failure. The concentration of these impurities is generally controlled by the water quality and by periodic draining of the generator.
RECOMMENDED FEEDWATER QUALITY
Hardness, ppm 8 – 85 (~0.5 – 5 gpg) P-Alkalinity, ppm 85 – 410 (~5 – 24 gpg) T. Alkalinity, ppm 200 – 500 (~7 – 0 gpg) pH (strength of alkalinity) 8.0 – 11.4
Every 2 months, or more often in “hard” water areas, the manual drain valve should be opened fully flushing out accumulated materials, salts and other particles which are natural by-products of boiling water.
The optional AutoFlush System feature automatical­ly drains the MrSteam generator following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation.
LOCATING THE STEAM GENERATOR
Select a location as near as practical to the steam room. Typical locations include: closet, vanity cabinet,
heated attic or basement.
NOTE:
control must be located accordingly. A 60 foot cable is available as a special order part for iTempo PN 103990-60 and PN 104117-60 for iSteam
IMPORTANT NOTE: The control cable should be run in a dedicated 1" conduit to facilitate installation and service.
together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
The standard length of the cable for connecting the control to the steam generator is 30 feet. The steam generator and
®
.
The maximum cable length is 60 feet.
WARNING
!
DO NOT route iSteam, AirTempo, iTempo/Plus, iTempo, HomeWizard or iGenie control wiring inside conduit
®
and AirTempo®,
WARNINGS
!
1. DO NOT a shock hazard will occur.
2. DO NOT wherever environmental conditions may result in a shock hazard or affect performance of the generator.
3. To prevent damage to the steam generator or a fire hazard DO NOT flammable or corrosive materials or chemicals such as gasoline, paint thinners, or the like. Installation in areas having high concentrations of chlorine (such as pool equipment room) must be avoided.
4. Burn Hazard. Steam line, safety valve, drain valve and plumbing become hot during operation and remain hot after shutdown for a period of time. Provide appropriate protection, including insulating plumbing lines. Avoid plumbing runs and steamhead locations that can come in contact with bathers.
5. Suitable for operation in ambient not exceeding 45 °C (113˚ F). Operation of the steam generator in an ambient temperature above 45 *C (113 *F) may result in a hazardous condition or property damage
CAUTIONS
!
DO NOT
6. unheated attic or any locations where water could freeze and cause pipes to rupture and cause property damage.
(Items 1-5)
install steambath generator inside steam room,
install steambath generator outdoors or
install steambath generator near
(Items 6-8)
install steambath generator or plumbing lines, in
7. Install steambath generator on a solid and level surface. Keyhole slots are provided for wall mounting. Insure the steam generator is properly secured and level when mounting with keyhole slots to prevent damage to the steam generator.
8. Install steambath generator in an upright position only to prevent damage to the generator.
IMPORTANT NOTES: (Items 9-13)
9. Install anti-water hammer device as necessary.
10.Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing. See page 8.
11.
Provide unions as required to facilitate installation and disconnection of piping.
12
. MrSteam controls can be located inside the steam room
or on the outside of the steam room. See the Control Installation Manual for your specific control package for specific details.
13. The MS series of steam generators are for residential use only. Commercial or other nonresidential applications void the warranty and may adversely affect product performance and may represent a safety hazard.
NOTE:
MrSteam Generators (inclusive of the iTempo, AirTempo
and iSteam series controls) are CE and UL listed.
4
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
TYPICAL MRSTEAM INSTALLATION
NOTE: Drawings for illustrative purposes only.
Consult with qualified designer, architect or contractor for steam room construction details.
Provide unions as required to facilitate installation and disconnect of piping
Field installed power supply
Steam Generator
Drain Valve must be closed
when the optional
AutoFlush is not installed
When installing the optional AromaSteam, install a down­ward facing 90-degree T in the steam supply line. See the AromaSteam Installation Manual for complete information.
Field installed water supply line
Field installed steam supply pipe
CAUTION
!
temperature sensor. Locate the control in a location representative of the desired steambathing temper­atures. Do not locate the control above or near the steam head or direct steam emissions.
Steam Head (shown with optional acrylic shield) See page 7 for Steam Head Installation information
CAUTION
!
where other controls, accessories, shower heads, valves, body sprays or similar within the shower could cause confusion or interfere with the MrSteam control’s intended use and function.
The control features an integral
Control cable run in 1” conduit (located
behind the wall)
To avoid unintentional steambath operation, do not locate the control
iSteam®, AirTempo or iTempo®Control
Refer to Control Installation Manual for installation information
®
I N S T A L L E R
TYPICAL INSTALLATION INSTRUCTIONS
FOR MODELS MS SUPER 4E, 5E & 6E
1. Install each steam generator as in a single installation. Install genera­tors as close as practical to each other, not exceeding 10 feet. The interconnecting cable length is 12 feet.
WARNING
2. Shock Hazard. Power must be disconnect-
!
ed at the main electrical supply. Remove steam gen­erator covers. Retain screws and covers for reuse.
3. Connect the iSteam
®
or AirTempo®control to either unit as per the Installation Manual supplied with each control.
4. Remove one knock-out on each generator as shown. Insert the ends of interconnecting cable provided (PN 103904) through the knock-outs as shown in diagram. Connect each end to the printed circuit board connector labeled "TANDEM" as shown.
5. Prevent the interconnecting cable from contacting hot surfaces such as steam outlet, safety valve and the like.
6. Connect separate plumbing and power supplies for each unit. Replace covers with cover screws.
7.
Provide unions as required to facilitate installation
and disconnection of piping
NOTE: The secondary unit will de-energize when the steam room reaches steambathing temperature resulting in a more gentle and energy efficient operation.
(shown with optional AutoFlush)
Power
Supply
Secondary Unit
5
Printed Circuit Board Component shown enlarged for illustrative purpose.
iSteam or
AirTempo
Primary Unit
Interconnecting Cable
Control
PN 103904
Optional AutoFlush Installation page 14
Water Feed Line
®
, see AutoFlush
All drawings are for illustrative purposes only
Control Cable
Steam Heads shown with optional acrylic shields
mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
INSTALLATION
I N S T A L L E R
PLUMBING
All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes.
1. Use unions on all pipe connections.
2. Use only brass piping or rigid copper tubing as permitted by codes.
3. DO NOT use black, galvanized, PVC pipe or PEX except as noted below.
WATER SUPPLY (3⁄8" NPT)
1. Connect to cold water line.
NOTE: Water feed line may be flexible copper tubing, braided hose, PVC or PEX if permissible by local codes.
2. Provide a shut off valve in the water supply line upstream of
the steambath generator.
3. DO NOT overheat inlet solenoid valve with solder connections.
Overheating will damage parts.
4. Flush inlet water line thoroughly before making connection
to unit.
5. Strainer recommended upstream of feed water connection.
6. In order to reduce operating noise, reducing feed water pres-
sure to between 15 - 20 psi is recommended. Optional pres­sure reducing valve part number 104198.
7. Provide anti-water hammer device as required.
8. Install an approved backflow preventer as required
by local codes.
DRAIN (1⁄2" NPT)
CAUTION
!
undersink trap, unless the generator is mounted higher than the sink to prevent damage to the generator if the drain backs up.
NOTE: A drain valve is provided to facilitate servicing. Provide a drain line connection from steambath generator drain valve according to National and local Codes. Check local plumbing code for receptor, trap and vent requirements. Do not connect Drain line and Safety Valve line together. Unit drains by gravity.
NOTE: Do not plumb the generator drain and drip pan drain together in such a way that will cause drain water to back into drip pan.
WARNING
!
location where accidental contact with drain water may occur. In the event of a power failure the AutoFlush System valve will open and may discharge boiling water causing a scalding hazard.
DO NOT connect the drain valve to the steam line
The drain from the generator should not share an
DO NOT drain into a steam enclosure or any
STEAM OUTLET (1⁄2" NPT)
1. DO NOT install any valve in steam line. Flow of steam must be unobstructed.
2. Use 1/2-inch brass pipe or copper tubing from unit to steam head as permitted by codes.
3. Insulate steam line with fiberglass pipe insulation or similar insulation rated 212° F or higher.
4. Pitch steam line 1/4" per foot towards steam head or steam generator to avoid valleys and trapping of condensate.
NOTE: Running the steam line down and then up will create a steam trap blocking the flow of steam.
NOTE: A 1.5" hole in the steam room is required to mount the steamhead.
SAFETY VALVE (3⁄4" NPT)
Where permitted by local codes, provide an outlet plumbing connection for safety valve.
WARNING
!
operation: DO NOT connect a shut off valve or a plug at safety valve outlet. DO NOT connect a shut off valve or any obstruc­tion in steam supply pipe. DO NOT connect the safety-valve output into the steam line.
To insure proper and automatic safety valve
DRIP PAN
MrSteam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Check local plumbing codes for receptor, trap and vent requirements. Drip pans drain by gravity. The drip pan is equipped with an integral3/4" fitting. See page 15 for additional drip pan installation information.
NOTE: Do not plumb the generator drain and drip pan drain together in such a way that will cause drain water to back into drip pan.
AROMASTEAM
If the optional AromaSteam Electronic Oil Delivery System
PN:MS AROMA
( fitting must be installed at a designated location on the steam outlet line. See the MrSteam AromaSteam Operation and Instruction Manual ( before the steam line is installed at the technical downloads section of www.mrsteam.com
) is to be installed, a 90 degree T plumbing
PN
: 100402) for installation information
6