instructions, you will notice warning and
caution symbols. This blocked information is
important for the safe and efficient installation and operation of this generator. These
are types of potential hazards that may
occur during installation and operation:
WARNING
!
hazardous situation, which, if not avoided, could
result in death or serious injury.
CAUTION
!
ardous situation, which, if not avoided may result in
minor or moderate injury or product damage.
IMPORTANT NOTE:
information that is especially relevant to a problemfree installation.
ll information in these instructions is based on
A
he latest product information available at the
t
time of publication. Sussman-Automatic Corporation
reserves the right to make changes at any time
without notice.
As you follow these
Indicates a potentially
Indicates a potentially haz-
his highlights
T
When installing and using this electrical equipment, basic safety precautions should
always be followed, including the following:
IMPORTANT SAFETY INSTR UCTIONS
.
1
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
2.
!
he age of 16 to use this steambath.
t
WARNING
3.
!
injury or death if improperly used. Steam rooms
contain steam and elevated temperatures.
Please read and observe all warnings in this
manual before installing or using a steam room.
WARNING
4.
!
A. The wet surfaces of steam enclosures
may be slippery. Use care when entering
or leaving.
B. The steam head is hot. DO NOT touch the
steam head and avoid the steam near
the steam head.
C. Prolonged use of the steam system can raise
excessively the internal human body temperature and impair the body’s ability to regulate its internal temperature (hyperthermia).
Limit your use of steam to 10-15 minutes
until you are certain of your body’s
reaction.
DO NOT permit children under
Steam is hot and can cause
To reduce the risk of injury:
D. Excessive temperatures have a high
potential for causing fetal damage during the early months of pregnancy.
Pregnancy or possibly pregnant women
should consult a physician regarding
correct exposure.
E. Obese persons and persons with a his-
tory of heart disease, low or high blood
pressure, circulatory system problems,
or diabetes should consult a physician
before using a steambath.
F. Persons using medication should con-
sult a physician before using a steambath since some medication may
induce drowsiness while other medications may affect heart rate, blood pressure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA occurs when the internal temperature of the
body reaches a level several degrees above the normal body
temperature of 98.6° F. The symptoms of hyperthermia
include an increase in the internal temperature of the body,
dizziness, lethargy, drowsiness, and fainting. The effects of
hyperthermia include:
WARNING
!
The use of alcohol, drugs, or medication can greatly increase the risk of hyperthermia.
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath; and
f) Unconsciousness.
Designed, Engineered
and Assembled in the
# # # #
USA
PUR 100472A Rev 1.17
mr.steam
43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM FAX: 718 472 3256
9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 1 800 72 STEAM FAX: 310 216 2944
Start working smarter with MrSteam’s mobile sizing app,
now available for the iPad
Visit mrsteam.com to size your generator automatically
or go directly to: http://isizing.mrsteam.com
Materials of construction, room size and special design features such
s large glass areas, all affect
a
1.
Measure length, width & height in feet of the steam/shower or tub/shower
Multiply the Length ____ x Width_____ x Height _____ =
2.
Construction Materials:
For natural stones: natural marble,Add 110%
stone, shale, glass block or concrete
For ceramic or porcelain tile onAdd 40%
cement board or mortar bed
3.
Ceiling Height: For each foot above 8 feetAdd 15%
4. Add all figures above to obtain the Total Room Volume required
Compare your Room Volume to the Chart below
®
, iPod®and most smart phones.
he steam generator model selection.
t
and select the appropriate model.
ROOM VOLUME
WARNING
!
se of this steambath system, please note that if
u
In considering the purchase or
you are pregnant, have a coronary condition, are
in poor health, are being treated for any other
medical condition, or are using medication or
drugs, MrSteam recommends that you obtain the
approval of a physician before use.
For information about this product and safety
issues, please call 1.800.76.STEAM
IMPORTANT NOTES:
or steam rooms constructed of acrylic or
F
synthetic materials, select next lower-rated
MS model.
The MrSteam Sizing Chart allows for up to 60 feet
of insulated steam line from the MS generator to
the steam room. If the 60 foot line is exceeded
consult with factory. The steam generator control
locations must be taken into account. A 30 foot
cable is standard. Contact MrSteam to purchase
an optional 60 ft. cable PN 103990-60 for
®
iTempo
iSteam
and AirTempo®and PN 104117-60 for
®
. The maximum cable length is 60 feet.
R E S I D E N T I A L S T E A M G E N E R ATO R S S P E C I F I C A T I O N C H A R T
Model No.KW240v/1PH)†Size‡Room Vol.Gallons††Dimensions*Wt. (lbs)**
MS90E521101000.6714½"L x 14¾"H x 6¾"D30
MS150E62581500.8014½"L x 14¾"H x 6¾"D30
MS225E7.53282251.014½"L x 14¾"H x 6¾"D30
MS400E93883601.214½"L x 14¾"H x 6¾"D30
MS SUPER 1E104284751.417"L x 18½"H x 77⁄8"D40
MS SUPER 2E125065751.617"L x 18½"H x 77⁄8"D40
MS SUPER 3E156346752.017"L x 18½"H x 7
MS SUPER 4E208488752.717"L x 18½"H x 77⁄8"D x 280
MS SUPER 5E24100610753.217"L x 18½"H x 77⁄8"D x 280
MS SUPER 6E30125412754.017"L x 18½"H x 7
IMPORTANT NOTES:
• Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to Model No. for 208V/1Ph.
• Models SUPER 1E-6E must use iTempo/Plus
• All MrSteam MS Models are cULus Listed and CE approved.
NOTES:
All MS Generators available in 240v/1PH, 208v/1PH and other voltages/phases.
† Amps are for 240/1PH rated units.
‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors.
Refer to the National Electrical Code for other types of conductors.
See MrSteam® Installation and Operation Manual for complete dimensional and installation information.
MS SUPER 4E includes two MS SUPER 1E steam generators, and require one iTempo/Plus
steam generators, and require one iTempo/Plus
iTempo/Plus
®
Control, and two matching steamheads.
®
control.
®
Control, and two matching steamheads. MS SUPER 6E includes two MS SUPER 3E steam generators, and require one
Amps (forWireTotal Adj.Water UsageShipping
®
Control, and two matching steamheads. MS SUPER 5E includes two MS SUPER 2E
2
7
⁄8"D40
7
⁄8"D x 280
*Dimensions are for generator only, without
AutoFlush® or plumbing features.
**Shipping weight and pricing are for generator only,
Carefully inspect the Steam Generator and packaging for
shipping damage. In the event of shipping damage, please
contact the carrier for claim information. Our
customer service department can assist you with any
missing or damaged parts.
Read these instructions before installation or service.
Although this MS steambath generator has been fully qualified for shipment by MrSteam
reviewed for proper, safe and enjoyable steam bathing:
1. Verify that the model and accessories specifications are
correct for the incoming line voltage.
2. Insure steambath generator has been correctly sized for
the steambath room. Pay particular attention to room vol-
®
, the following must be
STEAM ROOM GUIDELINES
1. Steam room must be completely enclosed, with full
walls, door, floor and ceiling.
2. It is recommended that a gasketed door is used for
steam containment.
WARNING
3.To prevent slip and fall hazards non-skip
!
strips must be installed on the steam room floor.
4. Check the suitability of any materials with the
manufacturer. Walls and ceilings must be constructed
of water-resistant, non-corrosive surface, such as tile,
marble, molded acrylic, or other non-porous material.
5. The ceiling should be sloped to prevent dripping of
condensate.
6. Provide a floor drain.
7. No heating, venting or air conditioning devices
should be installed inside the steam room.
8. Steam room tile construction information is available
from the Tile Council of America, Inc. by purchasing
the TCA Handbook for Ceramic Tile Installation.
Tel. (864) 646-8453 or www.tileusa.com.
9. Windows that are part of the steam room should be
double paned and tempered safety glass.
10. Limit steam room ceiling height to 8 feet. Exceeding
8 feet may require a higher-rated steam generator.
ume and construction. If any questions, please refer to
MrSteam sizing and selection guide on page 2.
3. Marble or glass walls or ceilings. “ENLARGE” the room’s
size, requiring a generator larger than one based only
on the room’s cubic foot (L x H x W) volume.
4. The physical size of the unit, clearance for plumbing
servicing, and its distance from the steam room must all
be considered before final installation.
5. Consider any controls and accessories before initiating
installation. Read the Installation and Operation Manual
of all controls and accessories available at
www.mrsteam.com technical downloads.
6. Record the serial number of the steam generator in the
space provided in the table of contents of this manual.
WARNING
!
manual is an essential part of providing a safe environment for
steam room users. The peel and stick warning label must be
applied to the wall of the shower or steam enclosure, at a point
that is visible to all users. Failure to install this sticker may result in
serious injury or death. The location where this owner's manual is
kept shall be written in the space provided on the label using permanent ink. For a replacement warning label contact MrSteam
customer service at 1-800-76-STEAM or hello@mrsteam.com
The peel and stick warning label located in this
Not Actual Size
I N S T A L L E R
WARNING
!
result in an inoperative or hazardous installation.
• Discontinue use of the steam generator and control if the steam
generator or control are damaged or otherwise not functioning
properly. Doing so may result in an inoperative or hazardous
installation
• ELECTRICAL SHOCK HAZARD. MrSteam steam generators are
connected to 240V line voltage and contain live electrical
components. All installation and service to be performed by
qualified and licensed electricians and plumbers only. Installation
or service by unqualified persons or failure to use MrSteam parts
may result in property damage or in a hazardous condition.
• The MS series of steam generators are for residential use only.
Commercial or other nonresidential applications void the warranty and may adversely affect product performance and may represent a safety hazard.
Never use damaged equipment, doing so may
CAUTION
!
rials are used as part of the steam room enclosure. Consult with the
material manufacture and see pg. 7, “Installing the Steamhead" for
additional details.
IMPORTANT NOTES:
This document contains important safety, operation and maintenance
information. Leave this document with the homeowner. Do not discard this document.
The following general information should be used in conjunction with
consultations with an architect, designer and contractor in determining factors necessary in providing a suitable and safe steam room.
MrSteam steam generators are intended to be operated with
MrSteam iSteam
and iGenie®controls only, and are to be installed strictly in accordance with the specific instructions contained in this manual and as
supplied in the manuals provided with the controls or accessories.
3
If acrylic, fiberglass or other non-heat resistant mate-
For optimum results, the water supply should be tested prior
o installation. If the mineral content exceeds the following
t
recommended limits, various external treatment processes
are recommended to correct the problem.
NOTE: An analysis of the on-site water must be made by
a recognized and reliable water treatment company to
ascertain the existing condition and treatment required.
Poor water quality can affect efficiency or result in steam generator damage. Water contains impurities in solution and suspension. These impurities concentrate in the generator. The
concentration of these impurities increases as more feedwater
is introduced into the generator and steam is produced. If the
suspended solids are allowed to concentrate beyond certain
limits, a deposit or “scale” will form on the generator internal
surfaces. This deposit can interfere with the proper generator
operation and cause generator failure. The concentration of
these impurities is generally controlled by the water quality
and by periodic draining of the generator.
Every 2 months, or more often in “hard” water areas,
the manual drain valve should be opened fully flushing
out accumulated materials, salts and other particles
which are natural by-products of boiling water.
The optional AutoFlush System feature automatically
drains the MrSteam
A time delay allows the water to cool down (about
two hours) before it drains by gravity for a safe and
gentle operation.
®
generator following each use.
LOCATING THE STEAM GENERATOR
Select a location as near as practical to the steam room.
Typical locations include: closet, vanity cabinet, heated attic or basement.
NOTE:
control must be located accordingly. A 60 foot cable is available as a special order part for iTempo
60 and PN 104117-60 for iSteam
IMPORTANT NOTE: The control cable should be run in a dedicated 1" conduit to facilitate installation and service.
together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
The standard length of the cable for connecting the control to the steam generator is 30 feet. The steam generator and
®
.
The maximum cable length is 60 feet.
WARNING
!
DO NOT route iSteam, AirTempo, iTempo/Plus, iTempo, HomeWizard or iGenie control wiring inside conduit
®
and AirTempo®, PN 103990-
WARNINGS
!
1. DO NOT
room, a shock hazard will occur
2. DO NOT
wherever environmental conditions may result in a
shock hazard or affect performance of the generator.
3. To prevent damage to the steam generator or a fire
hazard DO NOT
flammable or corrosive materials or chemicals such as
gasoline, paint thinners, or the like. Installation in areas
having high concentrations of chlorine (such as pool
equipment room) must be avoided.
4. Burn Hazard. Steam line, safety valve, drain valve and
plumbing become hot during operation and remain
hot after shutdown for a period of time. Provide
appropriate protection, including insulating plumbing
lines. Avoid plumbing runs and steamhead locations
that can come in contact with bathers.
CAUTIONS
!
5. DO NOT
in unheated attic or any locations where water could
freeze and cause pipes to rupture and cause property
damage.
6. Install steambath generator on a solid and level
surface. Keyhole slots are provided for wall mounting.
(Items 1-4)
install steambath generator inside steam
install steambath generator outdoors or
install steambath generator near
(Items 5-7)
install steambath generator or plumbing lines
Insure the steam generator is properly secured and level
when mounting with keyhole slots to prevent damage to
the steam generator.
7. Install steambath generator in an upright position only
to prevent damage to the generator.
IMPORTANT NOTES: (Items 8-12)
8. Install anti-water hammer device as necessary.
9.Provide a minimum of (12) inches at both ends and top of
the steam generator or as required for servicing. See page 8.
10.
Provide unions as required to facilitate installation
and disconnection of piping.
11
. MrSteam controls can be located inside the steam room
or on the outside of the steam room. See the Control
Installation Manual for your specific control package for
specific details.
12. The MS series of steam generators are for residential
use only. Commercial or other nonresidential applications
void the warranty and may adversely affect product
performance and may represent a safety hazard.
NOTE:
and iSteam series Controls) are CE and UL listed.
exceeding 45 °C (113˚ F)
MrSteam Generators (inclusive of the iTempo, AirTempo
Consult with qualified designer, architect or
contractor for steam room construction details.
Provide unions as required to facilitate
installation and disconnect of piping
Field installed
power supply
Steam
Generator
Drain Valve must be closed
when the optional
AutoFlush is not installed
When installing the optional AromaSteam, install a downward facing 90-degree T in the steam supply line. See the
AromaSteam Installation Manual for complete information.
Field installed
water supply line
Field installed
steam supply pipe
CAUTION
!
temperature sensor. Locate the control in a location
representative of the desired steambathing temperatures. Do not locate the control above or near the
steam head or direct steam emissions.
Steam Head (shown with optional acrylic shield)
See page 7 for Steam Head Installation information
CAUTION
!
where other controls, accessories, shower heads, valves, body sprays or similar within the
shower could cause confusion or interfere with the MrSteam control’s intended use and function.
The control features an integral
Control cable run in
1” conduit (located
behind the wall)
To avoid unintentional steambath operation, do not locate the control
iSteam®, AirTempo
or iTempo®Control
Refer to Control
Installation Manual
for installation
information
®
I N S T A L L E R
TYPICAL INSTALLATION INSTRUCTIONS
FOR MODELS MS SUPER 4E, 5E & 6E
1. Install each steam generator as in a single installation. Install generators as close as practical to each other, not exceeding 10 feet.
The interconnecting cable length is 12 feet.
WARNING
2.Shock Hazard. Power must be disconnect-
!
ed at the main electrical supply. Remove steam generator covers. Retain screws and covers for reuse.
3. Connect the iSteam
®
or AirTempo®control to either
unit as per the Installation Manual supplied with
each control.
4. Remove one knock-out on each generator as shown.
Insert the ends of interconnecting cable provided
(PN 103904) through the knock-outs as shown in
diagram. Connect each end to the printed circuit
board connector labeled "TANDEM" as shown.
5. Prevent the interconnecting cable from contacting
hot surfaces such as steam outlet, safety valve
and the like.
6. Connect separate plumbing and power supplies
for each unit. Replace covers with cover screws.
7.
Provide unions as required to facilitate installation
and disconnection of piping
NOTE: The secondary unit will de-energize when the
steam room reaches steambathing temperature resulting
in a more gentle and energy efficient operation.
(shown with optional AutoFlush)
Power
Supply
Secondary Unit
5
Printed Circuit Board Component
shown enlarged for illustrative purpose.
All plumbing shall be performed by a qualified licensed plumber
and in accordance with applicable National and local codes.
1. Use unions on all pipe connections.
2. Use only brass piping or rigid copper tubing as permitted
by codes.
3. DO NOT use black, galvanized, PVC pipe or PEX except as
noted below.
WATER SUPPLY (3⁄8" NPT)
1. Connect to cold water line.
NOTE: Water feed line may be flexible copper tubing, braided
hose, PVC or PEX if permissible by local codes.
2. Provide a shut off valve in the water supply line upstream of
the steambath generator.
3. DO NOT overheat inlet solenoid valve with solder connections.
Overheating will damage parts.
4. Flush inlet water line thoroughly before making connection
to unit.
5. Strainer recommended upstream of feed water connection.
6. In order to reduce operating noise, reducing feed water pres-
sure to between 15 - 20 psi is recommended. Optional pressure reducing valve part number 104198.
7. Provide anti-water hammer device as required.
8. Install an approved backflow preventer as required
by local codes.
DRAIN (1⁄2" NPT)
CAUTION
!
undersink trap, unless the generator is mounted higher than the
sink to prevent damage to the generator if the drain backs up.
NOTE: A drain valve is provided to facilitate servicing. Provide a
drain line connection from steambath generator drain valve
according to National and local Codes. Check local plumbing
code for receptor, trap and vent requirements. Do not connect
Drain line and Safety Valve line together. Unit drains by gravity.
NOTE: Do not plumb the generator drain and drip pan drain
together in such a way that will cause drain water to back into
drip pan.
WARNING
!
location where accidental contact with drain water may occur. In
the event of a power failure the AutoFlush System valve will
open and may discharge boiling water causing a scalding hazard.
DO NOT connect the drain valve to the steam line
The drain from the generator should not share an
DO NOT drain into a steam enclosure or any
STEAM OUTLET (1⁄2" NPT)
1. DO NOT install any valve in steam line. Flow of steam must
be unobstructed.
2. Use 1/2-inch brass pipe or copper tubing from unit to steam
head as permitted by codes.
3. Insulate steam line with fiberglass pipe insulation or similar
insulation rated 212° F or higher.
4. Pitch steam line 1/4" per foot towards steam head or steam
generator to avoid valleys and trapping of condensate.
NOTE: Running the steam line down and then up will create a
steam trap blocking the flow of steam.
NOTE: A 1.5" hole in the steam room is required to mount the
steamhead.
SAFETY VALVE (3⁄4" NPT)
Where permitted by local codes, provide an outlet plumbing
connection for safety valve.
WARNING
!
operation: DO NOT connect a shut off valve or a plug at safety
valve outlet. DO NOT connect a shut off valve or any obstruction in steam supply pipe. DO NOT connect the safety-valve
output into the steam line.
To insure proper and automatic safety valve
DRIP PAN
MrSteam strongly recommends the use of a drip pan in the
unlikely event of a plumbing leak. Check local plumbing codes
for receptor, trap and vent requirements. Drip pans drain by
gravity. The drip pan is equipped with an integral3/4" fitting.
See page 15 for additional drip pan installation information.
NOTE: Do not plumb the generator drain and drip pan drain
together in such a way that will cause drain water to back into
drip pan.
AROMASTEAM
If the optional AromaSteam Electronic Oil Delivery System
PN:MS AROMA
(
fitting must be installed at a designated location on the steam
outlet line. See the MrSteam AromaSteam Operation and
Instruction Manual (
before the steam line is installed at the technical downloads
section of www.mrsteam.com
) is to be installed, a 90 degree T plumbing
PN
: 100402) for installation information
6
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.