tions, you will notice warning and caution
symbols. This blocked information is important for the safe and eff icient installation and
operation of this generator. These are types
of potential hazards that may occur during
installation and operation:
Indicates a potentially
!
WARNING
hazardous situation, which, if not avoided,
could result in death or serious injury.
!
CAUTION
Indicates a potentially
hazardous situation, which, if not avoided
may result in minor or moderate injury or
product damage.
IMPORTANT NOTE: This highlights
information that is especially relevant to a
problem-free installation.
All information in these instructions is based
on the latest product information available at
the time of publication. Sussman-Automatic
Corporation reserves the right to make
changes at any time without notice.
1.READ AND FOLLOW ALL INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
!
2. Do not permit children under
WARNING
the age of 16 to use this steambath.
3. Steam is hot and can cause injury
!
WARNING
or death if improperly used. Steam rooms contain
steam and elevated temperatures. Please read
and observe all warnings in this manual before
installing or using a steam room.
!
WARNING
4. To reduce the risk of injury:
A. The wet surfaces of steam enclosures may be
slippery. Use care when entering or leaving.
B. The steam head is hot. Do not touch the
steamhead and avoid the steam near the
steamhead.
C. Prolonged use of the steam system can raise
excessively the internal human body temperature and impair the body’s ability to regulate
its internal temperature (hyperthermia). Limit
your use of steam to 10-15 minutes until you
are certain of your body’s reaction.
D. Excessive temperatures have a high
potential for causing fetal damage during the early months of pregnancy.
Pregnancy or possibly pregnant women
should consult a physician regarding correct exposure.
E. Obese persons and persons with a history
of heart disease, low or high blood
pressure, circulatory system problems,
or diabetes should consult a physician
before using a steambath.
F. Persons using medication should consult a
physician before using a steambath since
some medication may induce drowsiness
while other medications may affect heart
rate, blood pressure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA
perature of the body reaches a level several
degrees above the normal body temperature of
98.6° F. The symptoms of hyperthermia include
an increase in the internal temperature of the
body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
occurs when the internal tem-
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath; and
f) Unconsciousness.
for the f inished wall cut-out
9
⁄
”
3
16
iSteam3 Template
WARNING
!
The use of alcohol, drugs,
or medication can greatly
increase the risk of
hyperthermia.
1
⁄4”
5
2
Table of Contents:
Important Safety Instructions ........................ 2
eration, do not locate the control where other controls,
accessories, shower heads, valves, body sprays or similar within the shower could cause confusion or interfere
with the MrSteam control’s intended use and function.
CAUTION
!
• To prevent possible injury Do Not use the iSteam
control without reading and understanding the
MrSteam steam generator Installation and Operation
Manual.
• A peel and stick warning sticker is provided in the
MrSteam steam generator Installation, Operation and
Maintenance Manual. This manual is provided with
every steam generator. The warning sticker must be
read and permanently affixed in a conspicuous location near the steam room. Failure to read and affix
this warning sticker in a conspicuous location may
result in serious injury or death. Please call MrSteam
at 800 767-8326 for a free replacement or if you have
any questions regarding the warning sticker.
T
o avoid unintentional steambath op-
Do not route iSteam3 control wiring in-
CAUTION
!
side conduit together with power lines or close to hot
water or steam piping. Doing so may result in an inoperative or hazardous installation. Do not alter or modify
any Mr. Steam products including the steam generator
or iSteam3 control. Doing so may result in an inopera-
®
3
tive or hazardous installation and will void the warranty.
IMPORTANT NOTES:
• The iSteam3 Control is designed to be ush mounted.
However, the control may be surface mounted when
conditions permit. Consult a MrSteam Customer Service or Technical Service representative to determine if
the iSteam3 control can be surface mounted.
• Turn power to the steam generator OFF before
connecting the control to the generator. Failure to turn
the power off will result in an inoperable control.
• Do not operate the iSteam3 control with other than
a MrSteam iSteam3 compatible steam generator.
MrSteam residential steam generators with serial
numbers lower than 1174000, or any other brand of
steam generator are not to be operated with iSteam3
controls. Doing so may result in an inoperative installation. If your generator’s serial number is lower than
1174000 contact MrSteam Technical Service for upgrade options and components to enable your steam
generator to function with iSteam3.
• This document contains important safety, operation
and maintenance information. Leave this document
with the homeowner. Do not discard this document.
Not actual size
• If an iSteam3 control is installed outside the steam
room a Remote Temperature Probe (PN MSTS) must
be installed inside the steam room per installation
instructions supplied with the Remote Temperature
Probe. Failure to install according to instructions will
result in an inoperative control and overheating of
the steam room.
4
• Discontinue use of the steam generator or control
if the steam generator is damaged or otherwise not
functioning properly. Doing so may result in an inoperative or hazardous installation
• Refer to the Steambath Generator Installation,
Operation and Maintenance Manual for locating and
installing the steamhead.
WARNING
Do Not alter or modify any MrSteam
!
products. Doing so may result in an inoperable or
hazardous installation and will void the warranty.
Determine the desired installation location of the control. The iSteam
controls are designed to be installed inside or outside the steam room
as a matter of personal preference. If the control is installed inside
the steam room:
• Locate the control 4-5 feet above the oor near the bather seating area.
• The control features an integral temperature sensor. Locate the control in a
location representative of the desired steam bathing temperatures. Do not
locate the control above or near the steam head or direct steam emissions.
• Locate the control on a vertical wall.
• The control cable is 30 feet. Insure that the control and steam generator are
located accordingly.
IMPORTANT NOTES:
• If required, contact MrSteam to purchase an optional 60’ iSteam3
control cable part number 104117-60.
• If the control is installed outside the steam room a Remote Temperature
Probe Part Number MSTS must be installed inside the steam room.
Refer to the MSTS installation manual before installing the control.
• Insure MrSteam steam generator is iSteam3 compatible and has
a serial number 1174000 or higher.
®
3
1b
1a
1b
2a
3b
Installation with Optional Rough-In Box
A rough-in box is supplied with iSteam3 for new construction. The rough
-in box will allow precise location of the iSteam3 control and provide a
secure and easily identifiable place for the cable while the steam room is
being constructed.
STEP 1
screws (1a ) and place them in the top and bottom wings of the rough-in
box (1b).
STEP 2
STEP 3 Line up the two TABS (3a) on the right side of the box against a
stud. These TABS help locate the box to sit PROUD of the stud (3b).
STEP 4
STEP 5
box and clip it under one of the TABS (5b) that previously held the screws.
The two ends of the control cable are the same.
IMPORTANT NOTE: The control cable should be run in a dedicated 1”
conduit to facilitate installation and service.
Take the rough-in box out of the package. Remove the two
Select a KNOCK-OUT (2a) to route the control cable into the box.
SCREW (4a) the two supplied screws into the stud.
Route the CONTROL CABLE (5a) through the back of the rough-in
3a
4a
4a
5b
5a
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.