Mr. Steam HOMEWIZARDWH, HOMEWIZARDBLK Installation Manual

®
mr.steam
____________________________________________________________________________________________________________________________________________
Home Wizard
INSTALLATION AND OPERATION INSTRUCTIONS
____________________________________________________________________________________________________
Wireless Control with Smart Home Interface
TABLE OF CONTENTS
Safety & Operating Information . . . . . . . . . . .1
Home Wizard Interface Module Installation
Home Wizard Operation . . . . . . . . . . . . . . . . .
Home Wizard Interface Module Operation
Pairing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Battery Replacement . . . . . . . . . . . . . . . . . . .
Installing the Home Wizard Holder . . . . . . . .
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . .
List of Replacement Parts . . . . . . . . . . . . . . . .
___________________________________________________
. . .
. . . .
2 2 3 3 3 4 4 4
BOX CONTENT
• Home Wizard
• Home Wizard Holder
• Interface Module
• Lanyard
• 5 ft. Interface Module Connection Cable
• 2 Interface Module Mounting Screws
• Installation and Operation Instructions
___________________________________________________
IMPORTANT NOTE:
As you follow these instructions, you will notice warning and caution symbols. This blocked in­formation is important for the safe and efficient installation and operation of this Home Wizard. These are two types of potential hazards that may occur during this installation and operation:
WARNING
!
states a hazard which may cause serious injury or death if precautions are not followed.
CAUTION
!
signals a situation where minor injury or product damage may occur if you do not follow instruc­tions.
IMPORTANT NOTE: THIS HIGHLIGHTS IN-
FORMATION THAT IS ESPECIALLY RELEVANT TO A PROBLEM-FREE INSTALLATION.
SAFETY AND OPERATING INFORMATION
The Home Wizard is an energy efficient, state of the art auto­mation system, powering down your steam generator after 10 minutes if you are delayed.
WARNING
!
• Set the steambathing temperature according to personal preference, however it is highly recommended to begin steambathing at a low temperature setting to gauge comfort and safety levels. Set the duration at 10 minutes max. To gauge comfort and safety levels. This will allow the steam generator to heat up and begin producing steam.
• Do not install or use any iTempo reading and understanding the Mr.Steam steam generator Installation and Opera­tion Manual (part number 101289 Revision number 10.0/08 or higher). Failure to read and understand these instructions may result in an inoperative or hazardous installation.
• A peel and stick warning is provided with the Mr.Steam steam generator Installa­tion and Operation Manual. Mr.Steam strongly recommends that this warning be read and posted in a conspicuous location near the steam room.
• Install and use the iTempo install and use according to instructions will result in an inoperative control or haz­ardous overheating or inadequate heating of the steam room.
• A Home Wizard used in close proximity to multiple generators, may inadvertently turn them on. Please read the paragraph on pairing in this manual if more than one Home Wizard is used in close proximity.
CAUTION
!
• Ensure the steam room door is closed when using a Home Wizard. Leaving the steam room door open during steam generator operation may result in property damage.
• Do not route any iTempo, iSteam or Home Wizard control wiring inside conduit with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
• Do not alter or modify any iTempo, iSteam or Home Wizard controls. Doing so may result in an inoperative or hazardous installation.
IMPORTANT:
• Do not operate any other than a Mr.Steam iTempo or iSteam compatible steam generator. Mr.Steam residential steam generators with serial numbers lower than 900,000 or any other brand of steam generator are not to be operated with iTempo or iSteam controls. Doing so may result in an inoperative installation.
• This document contains important safety, operation and maintenance infor­mation. Leave this document with the homeowner. Do not discard this docu­ment.
• Discontinue use of the steam generator or control if the steam generator is damaged or otherwise not functioning properly.
––––––––––––––––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––––––––––––––––––––
iTempo, iSteam or Home Wizard
, iSteam®or Home Wizard™controls without
, iSteam®controls according to instructions. Failure to
control with anything
mr.steam
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
®
Sussman-Automatic Corp®
hello@mrsteam.com www.mrsteam.com
PUR 100449HA 2.14
mr.steam
H
o
m
e
W
i
z
a
r
d
O
n/Off
Button
R
ed/Green Indicating Light Ring
___________________________________________________________________________________________________________________________________
_
®
Installation & Operation Instructions Home Wizard
Plug the Home Wizard Interface Module cable into the Home Wizard location on the steam generator
To Home Automation system
(cable not included)
H Interface Module
ome Wizard
ON/OFF Button
ed and Green
R
ndicating Light Ring
I
Home Wizard Interface Module Cable
NOTE:For illustrative purposes only.
The iTempo control cable is not shown for clarity. An iTempo or iSteam must be used in conjunction with the Home Wizard.
HOME WIZARD INTERFACE MODULE INSTALLATION
• Installation of the Home Wizard Genie should be performed by a certi­fied Home Automation Integrator in accordance with applicable National andlocal electrical codes.
• Connect the Home Wizard Interface Module to the generator by plug­ging in the provided 5 foot cable to the Home Wizard Interface Module and the Home Wizard connector on the side of the generator as shown.
• Mount the Home Wizard Interface Module in a dry, indoor location. For maximum range, the Home Wizard Interface Module should be mounted as high as practical and away from metal that could effect the radio sig­nal. Securing it to a nearby wood stud is ideal. The antenna should be pointing upwards.
• 2 wire pairs (not supplied) must be provided to connect the Home Automation system and the Home Wizard.
• Using the supplied connector, connect the signal wires and feedback wires from the Home Automation system to the Home Wizard.
CAUTION
!
The signal from the Home Automation system must be a momentary contact closure to turn the Steam Generator ON or OFF. A sustained contact closure or voltage will damage the Home Wizard.
• The feedback from the Home Wizard is a sustained contact closure
when the steam generator is ON and an open circuit when the steam generator is OFF.
CAUTION
!
The maximum voltage for the
feedback circuit is 2A at 12 VDC
• With the generator powered, the red light (steam off) or green light
(steam on) should come on when plugged in. Press the TOGGLE STEAM button to confirm proper connection.
• Press the ON/OFF button and confirm that the Home Wizard lights
match the state of the steam generator. Red for STEAM OFF (eTempo control is off) and green for STEAM ON (eTempo control is on).
• The yellow RF activity light on the Home Wizard Interface Module should
flash each time the button on the Home Wizard FOB is pressed.
• Test the range of the Home Wizard FOB. It may be necessary to change
the location of the Home Wizard Interface Module to improve the range. Contact Mr.Steam technical service for an optional 60 ft. cable,
PN 103978-60.
HOME WIZARD OPERATION
WITH A HOME AUTOMATION SYSTEM:
• The Steam Generator will turn on when a signal is received from the Home Automation system.
The steam generator will run for a maximum of 10 minutes
when turned on using the Home Automation system. for longer than 10 minutes, simply turn the generator off then back on using the eTempo Control or the Home Wizard FOB.
WITH HOME WIZARD FOB:
When the Home Wizard FOB light is off, press the button once and
the Home Wizard FOB light indicates if the steam is on or off. When you press the button, the light will momentarily twinkle be­tween red and green. A red light indicates that the steam is off and a green light indicates that the steam is on. If you are out of range, the lights will twinkle for about 5 seconds and then shut off.
• To turn the steam on or off, press the ON/OFF button again while the light is illuminated. After a short delay the light will change from red to green (steam on) or green to red (steam off).
• The light will stay illuminated for 10 seconds and then shut off.
• A blinking red light indicates that an error condition exists in the steam generator. An error code will be displayed on your eTempo or eTempo/Plus control. Contact the Mr.Steam Technical Service Department at 800-76-STEAM (East coast) or 800-72-STEAM (West coast) for assistance or additional information.
CAUTION
!
room. Do not submerge the Home Wizard FOB in water. Doing so may result in an inoperative or hazardous installation.
2
The Home Wizard FOB may be used in the steam
To continue
Loading...
+ 2 hidden pages