mr. steam eTempo Plus Operation And Installation Instructions Manual

Page 1
mr.steam®aromasteam
Operation and Installation Instructions
_________________________________________________
MS AromaFlo®A
Table of Contents
Box Contents
Assembly and Installation
Assembly Diagram . . . . . . . . . . . . . . . . . . 5
Electrical Wiring
Sta
rt-up
Initial Priming of AromaSteam System Filling the Pressure Hose
Adjusting amount of oil delivery
Troubleshooting
Technical Information
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . .
. . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . .
. . . . . . . . . .
. . . . 7
. . . . . . . . . . . . . .
. . . . . . . . . .
2
3 4
6
7 7
8
8
WARNING
!
fragrance or fragrance containing emulsifiers or aldehy­des. AromaSteam system damage may result. Mr.Steam oils are approved for operation with this system.
WARNING
!
Mr.Steam oils may introduce excessive concentration of oil into the steam room, resulting in a health hazard.
WARNING
!
dizziness. Keep out of the reach of children. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. If swallowed, rinse mouth with water (only if the person is conscious), seek medical advice immediately and show this container or label.
WARNING
!
from sources of ignition– No smoking. Keep container tightly closed & in a well-ventilated place. This material & its container must be disposed of as hazardous waste.
WARNING
!
rooms.
Material Safety Data Sheet (MSDS) available upon request
IMPORTANT NOTE:
As you follow these instructions, you will notice warning and caution symbols.This blocked information is important for the safe and efficient installation and operation of this AromaSteam. These are two types of potential hazards that may occur during this installation and operation:
Do not use with water soluble
The use of any oils other than
Vapors may cause drowsiness and
Highly Flammable. Keep away
Not for use in acrylic or fiberglass
NOTE:
It is strongly recommended that this warning sign (supplied)
be posted in a conspicuous location near the steam room.
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or allergic reactions, including difficulty breathing or eye, nasal, throat, or skin irritation and seek medical attention.
mr.steam
1 800 76 STEAM www.mrsteam.com
AromaSteam
(for illustrative purposes only)
!
WARNING
®
43-20 34th Street , Long Island City NY 11101
PUR 100405
WARNING
!
states a hazard which may cause serious injury or death if precautions are not followed.
mr.steam
Sussman-Automatic Corp info@mrsteam.com www.mrsteam.com
®
43-20 34th Street
®
Long Island City, NY 11101 Tel: 1-800-76 STEAM Fax: 718-472-3256
CAUTION
!
signals a situation where minor injury or product damage may occur if you do not follow instructions.
9410 S. La Cienega Blvd. Inglewood CA 90301 1-800 -72 STEAM Fax: 310-216-2944
IMPORTANT NOTE:
This highlights information that is especially relevant to a problem-free installation.
PUR 100402 - 6/08
Motor Operated
Pumps24VW
Page 2
mr.steam®aromasteam Operation and Installation Instructions
TABLE OF CONTENTS
Box Contents . . . . . . . . . . . . . . . . . 2
Assembly and Installation
General
.. . . . . . . . . . . . . . . . . . . . 3
Pump Assembly
.. . . . . . . . . . . . . . . . 4
Installation of Hoses
.. . . . . . . . . . . . . . 4
System Schematic
.. . . . . . . . . . . . . . . 5
Electrical Wiring
.. . . . . . . . . . . . . . . . 6
Assembly Diagram
.. . . . . . . . . . . . . . . 7
Start-up
Initial Priming of Metering Pump
.. . . . . . 8
Filling the Pressure Hose
.. . . . . . . . . . . 8
Programming Table
.. . . . . . . . . . . . . . 9
Maintenance
M
aintenance of Metering Pump,
Suction Valve, and Pressure Valve
.. . . . . . 10
Troubleshooting.. . . . . . . . . . . . . . 11
Technical Information . . . . . . . . . . 11
SpareParts . . . . . . . . . . . . . . . . . . 11
Warranty.. . . . . . . . . . . . . . . . . . . 12
ADivision of Sussman-Automatic Corporation
43-20 34th Street, Long Island City, NY 11101 • (718) 937-4500 • 1-800-767-8326 • Fax:(718) 472-3256 • www.mrsteam.com
Western Regional Offices
9410 S.La Cienega Blvd., Inglewood CA 90301 • 1-800 72 STEAM (1-800 727-8326) • Fax:(310) 216-2944
P
UR 100402 - 01/06
NOTE:
Sussman-Automatic strongly recommends that this warning sign
(supplied) be posted in a conspicuous location near the steam room.
Donot use with water soluble fragrance or fragrance containing e
mulsifiers or aldehydes.AromaStean pump damage may result.
MrSteam oils are approved for operation with this pump.
The use of any oils other than MrSteam oils may introduce excessive concentration of oil into the steam room, resulting in a health hazard.
WARNING
!
WARNING
!
s
ignals a situation where minor injury or product
dam-age may occur if you do not follow instructions.
IMPORTANT NOTE:
THIS HIGHLIGHTS INFORMATION THAT IS ESPECIALLY RELEVANT TO A PROBLEM-FREE INSTALLATION.
IMPORT
ANT NOTE:
Asyou follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of t
his AromaSteam.These are two types of potential hazards that may occur during this installation and operation:
s
tates a hazard which may cause serious injury or death if precautions are not followed.
Fragrance Metering Pump for Residential Steam Rooms
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or allergic reactions, including difficulty breathing or eye, nasal, throat, or skin irritation and seek medical attention.
MrSteam
®
C
ommercial Steam Generators Sussman-Automatic Corp.43-20 34th Street , Long Island City NY 11101 1800 76 STEAM • www.mrsteam.com
WARNING
!
L
isted Oil Delivery
P
ump
24
V
W
mr.steamaromasteam
®
operation and installation instructions
_________________________________________________
WARNING
!
CAUTION
!
______________________________________________________________________________________________
Box Contents
Shipping Hose
AromaSteam System 6 ft. Pressure Hose 2 ft. Suction Hose with Filter & Bracket Assembly (with integrated 6 ft. power cord, 8 ft. request cable and 3 ft. demand cable)
1/2 inch NPT Atomizing Nozzle Injector with Injection Hose Scent Container Cap
Demand Button
(with integral 30 ft. cable)
Installation & Operation Manual
with Peel-off Warning Label
2
Page 3
mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
General Installation
CAUTION
!
For use with residential steam rooms only. Not for commercial use.
Locate the AromaSteam system to monitor the consumption of essential oils and for easy oil replacement.
1.
2.
Mr.Steam strongly suggests that the warning sticker provided be placed in a conspicuous location near the steam room.
3.
Mr.Steam AromaSteam System is designed and intended for indoor use only and is to be located indoors in a dry clean location and not subject to moisture, condensation or similar high humidity environments.
4.
Do not install AromaSteam Systems outdoors.
5.
Do not install AromaSteam Systems in a location where water could freeze.
6.
Do not install AromaSteam Systems near flammable or corrosive materials and chemi­cals. Installation in areas having high concentrations of chlorine (such as pool equip­ment room) should be avoided.
7.
Attach the AromaSteam System onto a secure vertical surface.
8.
Provide access to AromaSteam System for servicing, and refills.
9.
The system should not be installed in areas accessible to children. A LOCKED ROOM IS STRONGLY RECOMMENDED (ie: utility room)
10.
Height difference between AromaSteam System discharge and 90 degree
held to a maximum
The AromaSteam system is qualified for use with Mr.Steam residential steam generators ONLY.
!
WAR NI NG
This room is equipped with an aromatic oil dispensing system.
T is to be
6 ft. (see page 5).
Leave the room immediately if you have any adverse or allergic reactions, including difficulty breathing or eye, nasal, throat, or skin irritation and seek medical attention.
mr.steam
1 800 76 STEAM www.mrsteam.com
®
43-20 34th Street , Long Island City NY 11101
PUR 100405
Clearance to heat sources
Do not install the AromaSteam system directly below or above the Mr. Steam steam
generator where it is subject to heat.
Minimum distance between the AromaSteam system and a heat source (e.g. steam
generator, heating system) is 1.5 ft. If this minimum distance of 1.5 ft cannot be maintained, install a radiation plate or heat insulation between the heat source and AromaSteam system.
Ambient temperature at and around the AromaSteam system should not exceed 90˚ F.
Installing the 90 degree T and Atomizing Nozzle
1.
For optimal results locate a brass 90 degreeT(not provided) and atomizing nozzle in the steam supply line between 16" and 36" from the steam head (see page 5). If using copper tubing for steam lines, install a female 1/2 NPT thread to sweat fitting in the downward facing
must face downward as shown (in figure 2).
2. T
3.
Screw the atomizing nozzle into 90°Tfitting using teflon tape on the threads.
Note:
The further the 90°Tis from the steam head (more than 36”) the more the fra­grance degrades and be less effective. Conversely, the closer the 90°Tis to the steam­head (less than 16”) the less the fragrance will "blend" with the steam and the aroma effect will be lessen.
T.
90˚ T
Steam Line
1/2 NPT
Figure 2
IMPORTANT NOTE:
Follow the installation instructions for the steam pipeline in the Mr.Steam Residential Steam Bath Installation and Operating Manual (PUR 101289). Visit www.mrsteam.com to download this document.
3
Page 4
mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
Installation of Pressure Hose to AromaSteam System.
1.
Unscrew the pressure end nut from the pump head and remove the shipping hose
and the pressure end nut.
2.
Insert the pressure hose through the hole of the pressure end nut and firmly push
the pressure hose onto the pressure valve.
3.
Screw the pressure end nut onto the pressure valve and tighten the nut by HAND only.
Installation of Suction Hose in Scent Container
1.
Locate the “container cap” in the AromaSteam box.
2.
Unscrew the cap from the Mr.Steam scent container and discard.
Open End
Container Cap
Suction Hose
Filter
Container Height 8 inches
3.
Insert the suction hose with the open end from below through the hole in the
container cap (see Fig. 3).
4.
Insert the filter into the scent container so that the filter rests on the bottom.
5.
Screw the cap onto the scent container.
Installation of Suction Hose to AromaSteam System
1.
Unscrew the suction end nut from the pump head and remove shipping hose (see Fig. 3) (discard shipping hose, keep pressure end nut).
2.
Remove suction end nut from the shipping hose.
3.
Insert the open end of the suction hose through the hole of the suction end nut.
4.
Firmly push the hose onto the cone of the suction valve at the pump head.
5.
Screw the suction end nut to the suction valve.
IMPORTANT NOTE:
HAND-TIGHTEN ONLY.
Figure 3
Suction Suction Pump Pressure Pressure
End Nut Valve Head Valve End Nut
Figure 4
4
Page 5
mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
Typical AromaSteam Installation
For use with eTempo/Plus®Controls
Locate the AromaSteam system to monitor the consumption of essential oils and for easy oil replacement.
NOTE:
CABLES SHOULD NOT CONTACT STEAM PIPE.
FOR ILLUSTRATIVE PURPOSES ONLY
ypical Mr.Steam
T
team Generator
S
Cable to Steam Generator
(Request Cable)
Scent Container
AromaSteam
Demand Button
Pump Line Cord 120V
(grounded receptacle required)
Atomizer Nozzle
Pressure Hose
Suction Hose
Mounting Bracket
Steam Line
90˚ T
Mi
Ma
x
. d
Max ht.6 ft.
AromaSteam System
UTILITY
ROOM
eTempo/Plus
n
. d
i
s
t
a
n
c
e
i
s
16
t
a
n
"
c
e
36"
Steam Head
STEAM ROOM
For use with Tempo Tempo/Plus
®
and
eTempo®Controlss
®
,
Cable to Steam Generator
Typical Mr.Steam Steam Generator
(Request Cable)
Scent Container
Atomizer Nozzle
Pressure Hose
Suction Hose
Mounting Bracket
Steam Line
90˚ T
Mi
Ma
x
. d
Max ht.6 ft.
AromaSteam System
AromaSteam Demand Button
n
. d
i
st
a
n
ce
i
st
16
a
n
"
ce
36"
Steam Head
STEAM ROOM
Tempo, Tempo/Plus & eTempo
UTILITY
Pump Line Cord 120V
(grounded receptacle required)
ROOM
5
Page 6
mr.steam®aromasteam Operation and Installation Instructions
Contactor
Contactor
______________________________________________________________________________________________
Electrical Connection of AromaSteam™System
CAUTION
!
This AromaSteam system is factory wired. If the power cord of the AromaSteam system is damaged it must be replaced by the Sussman-Automatic service department or similarly qualified personnel in order to avoid risks. All electrical connections to be made by a licensed, qualified electrician. Disconnect all power to the steam generator before making power connec­tions.
1.
Disconnect all power to the Mr Steam steambath gen-
erator and remove the top cover.
2. Run the request cable from the AromaSteam System
through one of the knockouts in the side of the steambath generator. Use a strain relief bushing or grommet to prevent chafing.
3. Locate the contactor inside the steambath generator
and identify the red and red/white wires. (NOTE: Tempo generations use blue & white wires).
4. Remove those two wires from the contactor
and attach the request cable to those two terminals.
5. Reconnect the red and red/white wires by attaching
them to the piggyback terminals on the request cable.
AromaSteam Wiring Schematic
AromaSteam
120 VAC
Outlet
(grounded receptacle required)
Plug
Request Cable 24 VAC
Connector Connector
Demand Cable
to steam generator (see below)
AromaSteam Connections when using eTempo®Controls
(refer to Installation Instructions
Demand Button
for proper location)
NOTE: When using generators hooked up in tandem the AromaSteam steam system should be connected to the contactor on the primary generator. The atomizing nozzle should be connected to the main generator’s steam line.
Demand Button
ETEMPO/PLUS INSTALLATIONS:
1.
Locate the demand button on or near the pump brack­et. The demand button will be used to turn on the AromaSteam pump only during installation (and if power is cut to the pump) as the AromaSteam pump is controlled by the eTempo/Plus
TEMPO, TEMPO/PLUS AND ETEMPO INSTALLATIONS:
1.
Locate the demand button in a location accessible to the steambather. Mr.Steam suggests adjacent to the Tempo Controls.
2. A 7/8 inch hole is required for the demand button.
3. Fill the hole with silicone as required for a mois-
ture seal, care should be taken not to get silicone on the adhesive on the back of the button.
For Tempo, Tempo/Plus, and eTempo
Contactor location in MS-65T- MS400T and MS90E - MS400E
For Tempo, Tempo/Plus, and eTempo
Contactor location in MSSUPER1T- MSSUPER6T and MSSUPER1E- MSSUPER6E
6
Page 7
mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
Start-up
Initial Priming of the Pump
1. Insure MrSteam scent container is full.
2. Insert the short injector hose onto the tip of the injector
(see Fig. 5).
3. Unscrew the pressure end nut from the pump head and remove the pressure hose from the pressure valve (see Fig.3).
4. Insert the open end of the injection hose onto the pressure valve (see Fig. 5).
5. Draw liquid from the injector slowly and evenly. Continue until the injector is full of liquid.
6. If you have drawn up the injector completely and no liquid is in the injector, remove the injector hose from the pressure valve.
7. Drain injector. Repeat steps until the injector is filled.
8. Save the oil injector as it will be needed when new oils are used.
Filling the Pressure Hose
1.
Insure the AromaSteam System is primed and the scent container
is full.
2
. Locate the Push-button at the rear of the metering pump (see
Fig. 6). Depress this push-button to start metering pump.
3.
Continue to depress push-button until the pressure hose is filled with liquid.
Figure 5
Pressure Valve
AromaSteam
Metering Pump
Injector Hose
IMPORTANT NOTE:
of the pressure hose, and after new oil bottles are installed.
Push button to be used only for initial filling
Operation
ETEMPO/PLUS
1.
Press the AROMA button on the eTempo/Plus control (Aroma will appear in the display).
2
. When the generator is steaming the pump will inject oil into the
steam line at preset time intervals.
3
. If the generator is not steaming, no oil will be pumped.
TEMPO, TEMPO/PLUS AND ETEMPO
1.
With the generator on press the demand button once
(the demand button will light up).
2
. When the generator is steaming the pump will inject oil into the
steam line at preset time intervals.
3
. If the generator is not steaming, no oil will be pumped.
Note:
After the generator has been turned off the light on the demand button will remain ON, the pump will be in stand-by mode waiting for the generator to be turned on again.
Aroma button
Push Button
Figure 6
Adjusting the Amount of Oil Delivery
WARNING
!
suitable amount of aromatic oil into a typical sized steam room. PLEASE CONTACT THE MRSTEAM TECHNICAL SERVICE DEPARTMENT BEFORE CHANGING THIS SETTING.
Increasing the settings may introduce excessive concentration of oil into the steam room, resulting in a health hazard.
Contact the MrSteam Technical Service Department at (800) 76-STEAM (East coast) or (800) 72-STEAM (West coast)
WARNING
!
personnel may adjsut the factory setting.
The AromaSteam system has been factory set to deliver a
for assistance or additional information.
Only a qualified licensed electrician or factory authorized
7
Page 8
mr.steam®aromasteam Operation and Installation Instructions
______________________________________________________________________________________________
Troubleshooting
WARNING
!
TO AVOID ELECTRIC SHOCK, DISCONNECT POWER TO PUMP BEFORE SERVICING
METERING PUMP DOES NOT PRIME
1.
Check if voltage is available.
2.
Check liquid level in scent container. Replenish liquid, if necessary.
3.
Check for air bubbles in the suction hose or the pump head. To eliminate air bubbles see: Priming Pump.
4.
Check valves for contamination. Clean valves, if necessary.
5.
Check filter in container for contamination. Rinse filter under clean water.
Metering pump does not inject oil into steam room
1.
Check if voltage is available.
2.
Check liquid level in scent container. Replenish liquid, if necessary.
3.
Check for air bubbles in the suction hose or the pump head. To eliminate air bubbles see: Priming Pump.
4.
Check valves for contamination. Clean valves, if necessary.
5.
Check filter in container for contamination. Rinse filter under clean water.
6.
Check the pressure hose for kinking or jamming. Straighten or replace.
7.
Check if liquid is freely flowing through the atomizing nozzle when the metering pump is energized. Apply compressed air through the atomizing
nozzle. Attach the compressed air at the point of connection of the pressure hose.
8.
For eTempo/Plus: ensure the demand button light is on. the demand button light should be pressed during installation, the light willl turn on. In
the event of a power outage the button will need to be pressed again.
Metering pump oil delivery too much or too little
Contact Mr.Steam techincal service personnel at 1-800-76 STEAM (East Coast) or 1-800-72-STEAM (West Coast).
Technical Specifications
List of Spare Parts
Description Part No.
Pump Head 103861 Pressure/Suction Hose EO1-1032
(ordered by the foot)
Eucalyptus oil, 1 liter MS OIL 1 Lavender oil, 1 liter MS OIL 2 Evergreen oil, 1 liter MS OIL 3 Energizing Mint oil, 1 liter MS OIL 4 Poho oil, 1 liter MS OIL 5 Atomizing Nozzle 103918 Oil Injector 103983 Filter 103987
Dimensions: 7” L x 6.5” W x 4.5” H ___________________________________________
Weight: 5 pounds ___________________________________________
EN 60335 UL Listed CSA Approved
___________________________________________ Motor voltage 120 VAC, 50/60 Hz
Power consumption, total [W] 12 Watt
MR.STEAM and des., A LIFETIME OFPLEASURE, ALLEGRO, AROMAFLO, AUTOFLUSH, CLEAN STEAM...EVER TIME, MRSAUNA,STEAM ON DEMAND, STEAM@HOME, SUSSMAN, SUSSMAN LIFESTYLE GROUP, TEMPO, TEMPO/PLUS, TEMPO/REMOTE, TEMPO/EXT, WARMATOWEL, eTEMPO, eTEMPO/PLUS, eTEMPO/REMOTE, eTEMPO/START and STEAMTHERAPY, are registered trademarks of Sussman-Automatic Corporation. AROMASTEAM, CLUB THERAPY, CHROMASTEAM, F1 PLUS, MUSICTHERAPY, SAUNA/ONE, MAKE WELLNESS a WAY of LIFE and FROM BATHROOM TO SPA are trademarks of Sussman-Automatic Corporation.
8
Loading...