Initial Priming of AromaSteam System
Filling the Pressure Hose
Adjusting amount of oil delivery
Troubleshooting
Technical Information
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . .
. . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . .
. . . . . . . . . .
. . . . 7
. . . . . . . . . . . . . .
. . . . . . . . . .
2
3
4
6
7
7
8
8
WARNING
!
fragrance or fragrance containing emulsifiers or aldehydes. AromaSteam system damage may result. Mr.Steam
oils are approved for operation with this system.
WARNING
!
Mr.Steam oils may introduce excessive concentration of
oil into the steam room, resulting in a health hazard.
WARNING
!
dizziness. Keep out of the reach of children. In case of
contact with eyes, rinse immediately with plenty of
water and seek medical advice. If swallowed, rinse mouth
with water (only if the person is conscious), seek medical
advice immediately and show this container or label.
WARNING
!
from sources of ignition– No smoking. Keep container
tightly closed & in a well-ventilated place. This material
& its container must be disposed of as hazardous waste.
WARNING
!
rooms.
Material Safety Data Sheet (MSDS) available upon request
IMPORTANT NOTE:
As you follow these instructions, you will notice warning and caution symbols.This blocked information is important for the safe and efficient
installation and operation of this AromaSteam. These are two types of potential hazards that may occur during this installation and operation:
Do not use with water soluble
The use of any oils other than
Vapors may cause drowsiness and
Highly Flammable. Keep away
Not for use in acrylic or fiberglass
NOTE:
It is strongly recommended that this warning sign (supplied)
be posted in a conspicuous location near the steam room.
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
mr.steam
1 800 76 STEAM www.mrsteam.com
AromaSteam
(for illustrative purposes only)
!
WARNING
®
43-20 34th Street , Long Island City NY 11101
PUR 100405
WARNING
!
states a hazard which may cause serious injury
or death if precautions are not followed.
Sussman-Automatic strongly recommends that this warning sign
(supplied) be posted in a conspicuous location near the steam room.
Donot use with water soluble fragrance or fragrance containing
e
mulsifiers or aldehydes.AromaStean pump damage may result.
MrSteam oils are approved for operation with this pump.
The use of any oils other than MrSteam oils may introduce excessive
concentration of oil into the steam room, resulting in a health hazard.
WARNING
!
WARNING
!
s
ignals a situation where minor injury or product
dam-age may occur if you do not follow instructions.
IMPORTANT NOTE:
THIS HIGHLIGHTS INFORMATION THAT IS ESPECIALLY
RELEVANT TO A PROBLEM-FREE INSTALLATION.
IMPORT
ANT NOTE:
Asyou follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of
t
his AromaSteam.These are two types of potential hazards that may occur during this installation and operation:
s
tates a hazard which may cause serious injury
or death if precautions are not followed.
Fragrance Metering Pump
for Residential Steam Rooms
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
MrSteam
®
C
ommercial Steam Generators
Sussman-Automatic Corp.43-20 34th Street , Long Island City NY 11101
1800 76 STEAM • www.mrsteam.com
AromaSteam System6 ft. Pressure Hose2 ft. Suction Hose with Filter
& Bracket Assembly
(with integrated 6 ft. power cord,
8 ft. request cable and 3 ft. demand cable)
1/2 inch NPT Atomizing NozzleInjector with Injection HoseScent Container Cap
Demand Button
(with integral 30 ft. cable)
Installation & Operation Manual
with Peel-off Warning Label
2
Page 3
mr.steam®aromasteamOperation and Installation Instructions
For use with residential steam rooms only. Not for commercial use.
Locate the AromaSteam system to monitor the consumption of essential oils and for easy oil replacement.
1.
2.
Mr.Steam strongly suggests that the warning sticker provided be placed in a conspicuous location near the
steam room.
3.
Mr.Steam AromaSteam System is designed and intended for indoor use only and is to be located indoors in a dry
clean location and not subject to moisture, condensation or similar high humidity environments.
4.
Do not install AromaSteam Systems outdoors.
5.
Do not install AromaSteam Systems in a location where water could freeze.
6.
Do not install AromaSteam Systems near flammable or corrosive materials and chemicals. Installation in areas having high concentrations of chlorine (such as pool equipment room) should be avoided.
7.
Attach the AromaSteam System onto a secure vertical surface.
8.
Provide access to AromaSteam System for servicing, and refills.
9.
The system should not be installed in areas accessible to children. A LOCKED ROOM
IS STRONGLY RECOMMENDED (ie: utility room)
10.
Height difference between AromaSteam System discharge and 90 degree
held to a maximum
The AromaSteam system is qualified for use with Mr.Steam residential steam generators ONLY.
!
WAR NI NG
This room is equipped with an aromatic oil dispensing system.
T is to be
6 ft. (see page 5).
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
mr.steam
1 800 76 STEAM www.mrsteam.com
®
43-20 34th Street , Long Island City NY 11101
PUR 100405
Clearance to heat sources
•
Do not install the AromaSteam system directly below or above the Mr. Steam steam
generator where it is subject to heat.
•
Minimum distance between the AromaSteam system and a heat source (e.g. steam
generator, heating system) is 1.5 ft. If this minimum distance of 1.5 ft cannot be
maintained, install a radiation plate or heat insulation between the heat source and
AromaSteam system.
•
Ambient temperature at and around the AromaSteam system should not exceed 90˚ F.
Installing the 90 degree T and Atomizing Nozzle
1.
For optimal results locate a brass 90 degreeT(not provided) and atomizing nozzle
in the steam supply line between 16" and 36" from the steam head (see page 5). If
using copper tubing for steam lines, install a female 1/2 NPT thread to sweat fitting
in the downward facing
must face downward as shown (in figure 2).
2. T
3.
Screw the atomizing nozzle into 90°Tfitting using teflon tape on the threads.
Note:
The further the 90°Tis from the steam head (more than 36”) the more the fragrance degrades and be less effective. Conversely, the closer the 90°Tis to the steamhead (less than 16”) the less the fragrance will "blend" with the steam and the aroma
effect will be lessen.
T.
90˚ T
Steam Line
1/2 NPT
Figure 2
IMPORTANT NOTE:
Follow the installation instructions for the steam
pipeline in the Mr.Steam Residential Steam Bath Installation and Operating
Manual (PUR 101289). Visit www.mrsteam.com to download this document.
3
Page 4
mr.steam®aromasteamOperation and Installation Instructions
This AromaSteam system is factory
wired. If the power cord of the AromaSteam system is
damaged it must be replaced by the Sussman-Automatic
service department or similarly qualified personnel in
order to avoid risks. All electrical connections to be made
by a licensed, qualified electrician. Disconnect all power
to the steam generator before making power connections.
1.
Disconnect all power to the Mr Steam steambath gen-
erator and remove the top cover.
2. Run the request cable from the AromaSteam System
through one of the knockouts in the side of the
steambath generator. Use a strain relief bushing or
grommet to prevent chafing.
3. Locate the contactor inside the steambath generator
and identify the red and red/white wires. (NOTE:
Tempo generations use blue & white wires).
4. Remove those two wires from the contactor
and attach the request cable to those two
terminals.
5. Reconnect the red and red/white wires by attaching
them to the piggyback terminals on the request cable.
AromaSteam Wiring Schematic
AromaSteam
120 VAC
Outlet
(grounded receptacle required)
Plug
Request Cable
24 VAC
ConnectorConnector
Demand Cable
to steam generator
(see below)
AromaSteam Connections when using
eTempo®Controls
(refer to Installation Instructions
Demand Button
for proper location)
NOTE: When using generators hooked up in tandem the
AromaSteam steam system should be connected to the
contactor on the primary generator. The atomizing nozzle
should be connected to the main generator’s steam line.
Demand Button
ETEMPO/PLUS INSTALLATIONS:
1.
Locate the demand button on or near the pump bracket. The demand button will be used to turn on the
AromaSteam pump only during installation (and if
power is cut to the pump) as the AromaSteam pump is
controlled by the eTempo/Plus
TEMPO, TEMPO/PLUS AND ETEMPO INSTALLATIONS:
1.
Locate the demand button in a location accessible
to the steambather. Mr.Steam suggests adjacent to
the Tempo Controls.
2. A 7/8 inch hole is required for the demand button.
3. Fill the hole with silicone as required for a mois-
ture seal, care should be taken not to get silicone
on the adhesive on the back of the button.
For Tempo, Tempo/Plus, and eTempo
Contactor location in MS-65T- MS400T
and MS90E - MS400E
For Tempo, Tempo/Plus, and eTempo
Contactor location in MSSUPER1T- MSSUPER6T
and MSSUPER1E- MSSUPER6E
6
Page 7
mr.steam®aromasteamOperation and Installation Instructions
2. Insert the short injector hose onto the tip of the injector
(see Fig. 5).
3. Unscrew the pressure end nut from the pump head and remove the
pressure hose from the pressure valve (see Fig.3).
4. Insert the open end of the injection hose onto the pressure valve
(see Fig. 5).
5. Draw liquid from the injector slowly and evenly. Continue until the
injector is full of liquid.
6. If you have drawn up the injector completely and no liquid is in the
injector, remove the injector hose from the pressure valve.
7. Drain injector. Repeat steps until the injector is filled.
8. Save the oil injector as it will be needed when new oils are used.
Filling the Pressure Hose
1.
Insure the AromaSteam System is primed and the scent container
is full.
2
. Locate the Push-button at the rear of the metering pump (see
Fig. 6). Depress this push-button to start metering pump.
3.
Continue to depress push-button until the pressure hose is filled
with liquid.
Figure 5
Pressure Valve
AromaSteam
Metering Pump
Injector Hose
IMPORTANT NOTE:
of the pressure hose, and after new oil bottles are installed.
Push button to be used only for initial filling
Operation
ETEMPO/PLUS
1.
Press the AROMA button on the eTempo/Plus
control (Aroma will appear in the display).
2
. When the generator is steaming the pump will inject oil into the
steam line at preset time intervals.
3
. If the generator is not steaming, no oil will be pumped.
TEMPO, TEMPO/PLUS AND ETEMPO
1.
With the generator on press the demand button once
(the demand button will light up).
2
. When the generator is steaming the pump will inject oil into the
steam line at preset time intervals.
3
. If the generator is not steaming, no oil will be pumped.
Note:
After the generator has been turned off the light on the
demand button will remain ON, the pump will be in stand-by mode
waiting for the generator to be turned on again.
Aroma button
Push Button
Figure 6
Adjusting the Amount
of Oil Delivery
WARNING
!
suitable amount of aromatic oil into a typical sized steam room. PLEASE CONTACT
THE MRSTEAM TECHNICAL SERVICE DEPARTMENT BEFORE CHANGING THIS SETTING.
Increasing the settings may introduce excessive concentration of oil into the
steam room, resulting in a health hazard.
Contact the MrSteam Technical Service Department at (800) 76-STEAM (East
coast) or (800) 72-STEAM (West coast)
WARNING
!
personnel may adjsut the factory setting.
The AromaSteam system has been factory set to deliver a
for assistance or additional information.
Only a qualified licensed electrician or factory authorized
7
Page 8
mr.steam®aromasteamOperation and Installation Instructions
___________________________________________
Motor voltage120 VAC, 50/60 Hz
Power consumption, total [W]12 Watt
MR.STEAM and des., A LIFETIME OFPLEASURE, ALLEGRO, AROMAFLO, AUTOFLUSH, CLEAN STEAM...EVER TIME, MRSAUNA,STEAM ON DEMAND, STEAM@HOME,
SUSSMAN, SUSSMAN LIFESTYLE GROUP, TEMPO, TEMPO/PLUS, TEMPO/REMOTE, TEMPO/EXT, WARMATOWEL, eTEMPO, eTEMPO/PLUS, eTEMPO/REMOTE,
eTEMPO/START and STEAMTHERAPY, are registered trademarks of Sussman-Automatic Corporation. AROMASTEAM, CLUB THERAPY, CHROMASTEAM, F1 PLUS,
MUSICTHERAPY, SAUNA/ONE, MAKE WELLNESS a WAY of LIFE and FROM BATHROOM TO SPA are trademarks of Sussman-Automatic Corporation.
8
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.