Mr Steam CU1-D1, CU2-D1 User Manual

Page 1
Digital 1 Control Operation
Digital 1 Control Operating Parameters
Operating Temperature range 100 – 120 °F (37.5 – 49 °C)
Backup Temperature shut off fixed at 130 °C (54.5 °C)
Setting Operating Temperature
SET
2. Use the 100 °F (37.5 °C).
*Note the control display remains on if the steam bath generator switch is in the OFF position, however power to the solenoids will be OFF.
Operation Indicators
OUT 1: The LED under
conditions. If the light under backup temperature mode, an alarm will sound, the display will flash and the steam bath generator will be off.
OUT 2: The LED under
conditions. If the light under temperature is satisfied and the steam solenoid valve will be closed. When the light under temperature has not been satisfied and the steam solenoid should be open (if a 30 minute timer is used, that must be on to open the steam solenoid).
Backup Temperature Shut-off
In the event room conditions or environment cause the temperature to reach 130 °F (54.5 °C) the Digital 1 Control will shut off power to the steam bath generator.
The display will change to a flashing also sound.
To silence the Digital 1 Control Alarm press silenced but the display will still flash
*Note if equipped with a CU ALARM turn the steam bath generator switch off to silence it.
The Digital 1 control will reset when the temperature in the room reaches normal operating ra nge.
Message Display
Under normal operation, the actual room temperature will be displayed, the f ollowing messages may also appear (the Digital 1 Control alarm will also sound, press equipped with a CU ALARM turn the steam bath generator switch will shut off until the error is cleared):
Err – Memory reading error, cut power to control to clear
AH1 – Backup temperature alarm
AL1 (AL2) – Low temperature alarm, this may be an indication of a probe problem, check the actual
room temperature
ooo – Open Probe, check probe connection, check probe with multimeter
--- – Shorted probe, check any splices used, check probe with multimeter (note: if equipped with CU
STEAMSTOP, the Digital 1 Control will display --- when the CU STEAMSTOP is pressed, reset the CU STEAMSTOP to clear)
Compliance
The Digital 1 control meets
button twice, the light under
UP
/
DOWN
arrows to set the temperature. Factory set at
SET
button again; the display will be solid and showing
OUT 1
is on during normal operating
OUT 1
OUT 2
goes on and off during normal operating
OUT 1
OUT 2
and CE requirements.
OUT 2
will be on and
is off the Digital 1 is in
is off the room
is on the room
AH1
, and an alarm will sound (if equipped the CU ALARM will
SET
and
DOWN
simultaneously. The alarm will be
AH1
and the steam bath generator will remain off.
SET
and
DOWN
simultaneously to silence alarm, if
OFF
to silence it, the steam bath generator
PUR 100457 Rev 3/12