Mr. Steam CT6EC1PC, CT9EC1PC, CT12EC1I3BK, CT15EC1PC, CT15EC1I3BK Specifications

...
Page 1
®
mr.steam
CT Day Spa Packages
Technical Specifications
CT DAY SPA SYSTEM
• iTempoPlus®Control
• Matching AromaSteam Steamhead with Acrylic Shield (
• AutoFlush®System
®
• Express Steam
• Drip Pan
• CT-SteamStop
• MSTS In-Room Temperature Sensor (
factory installed (
CT-PACKAGE ISTEAM
• Steam Control
• Matching iSteam Steamhead
®
• AutoFlush
• Express Steam
• Drip Pan
• CT-SteamStop
• MSTS In-Room Temperature Sensor (
System
®
factory installed (
For Models CT6 to CT15
not shown
For Models CT6 to CT15
not shown)
)
not shown)
not shown)
not shown)
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
MODEL SHAPE FINISH PROJECT INFORMATION
CT DAY SPA
SYSTEM
CT-PACKAGE
iSteam
mr.steam
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
®
RD Round

SQ Square

  
 
 
N/A
 
Sussman-Automatic Corp®
PC - Polished Chrome
BN - Brushed Nickel
PN - Polished Nickel
ORB - Oil Rubbed Bronze
BB - Brushed Bronze
PB - Polished Brass
RAW -
Custom Plating
WH -
White
BK -
Black
hello@mrsteam.com www.mrsteam.com
Location:
Architect:
Engineer:
Contractor:
Submitted By:
Date:
Notes:
TS0052 12.14
Page 2
mr.steam
2
1
/
2
4
1
/
2
1
/
4
3
/
8
3
/
4
1”
5”
5”
3
3
/
4
12” long pigtail
®
T E CHN I C A L S P E C I F I C AT I O N S
iTempoPlus™CONTROLS
iTempoPlus™controls flush mount in the steam/shower enclosure through a
5
8wide x 37⁄8
2
iTempoPlus™Controls Feature:
• Solid brass decorative cover with choice of square or round styles in designer finishes
• Digital display
• Programmable temperature
• AromaSteam steamhead in matching finish and shape
• Compatibility with iGenie
The iTempoPlus controls are designed to be installed inside or outside the steam room but is primarily installed inside the steam room. If the control is installed inside the steam room the control must be located:
• 4-5 feet above the floor
• in a location representative of the desired steam bathing temperatures. Do not locate the control above or near the steam head or direct steam emissions.
• on a vertical wall
The control cable length is 30 feet. Insure that the control and/or steam generator are located accordingly.
An optional 60 ft. cable is available if required, PN 103990-60. If the control is installed outside the steam room a Remote Temperature
Probe Part Number MSTS must be installed inside the steam room.
high hole. iTempo controls can also be surface mounted.
• Soft touch keypad
• Low voltage operation
• Programmable steam bath duration
• Clock
• ON/OFF control for AromaSteam and ChromaSteam
®
• Two programmable presets
®
BOX CONTENTS:
iTempoPlus
Tube of Silicone Sealant
• Steamhead • Owner’s Manual
• Control Cable (30 ft.)
Dimensional Information for the round and square controls:
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
MODEL SHAPE FINISH PROJECT INFORMATION
MS iTempoPlus
RD Round

SQ Square

BB - Brushed Bronze

BN - Brushed Nickel

ORB - Oil Rubbed Bronze

PB - Polished Brass

PC - Polished Chrome

PN - Polished Nickel
 
RAW -
Custom Plating
Location:
Architect:
Engineer:
Contractor:
Submitted By:
Date:
Notes:
mr.steam
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
®
Sussman-Automatic Corp®
hello@mrsteam.com www.mrsteam.com
TS0035 Rev 5.14
Page 3
®
10:06 AM
ACCESSORIES SETTINGS
S
TAR T
mr.steam
iSteam®2.0 Control
Technical Specifications
Box Contents:
• iSteam®2.0 Control
Dimensional Information
5
6
• Owner’s Manual
• Control Cable (30 ft.)
• Rough-In Box
• Steamhead
• Optional Surface
3
4
4
• Tube of Silicone Sealant Mount Gasket
iSteam controls flush mount in the steam/shower enclosure through a 5-1/4” wide x 3-9/16” high hole. iSteam controls can also be surface mounted. They are suitable for use with an available iGenie®control. Available in black or white.
iSteam controls are suitable for use inside or outside the steam/shower enclosure, featuring:
• Full color LCD touch screen
• Programmable temperature
• Programmable time
• Two user presets
• AromaSteam, ChromaSteam
and AudioWizard™controls
• Passcode to prevent uninten­tional use of steam bath
• Includes AromaSteam steam head in white or black
• Compatible with iGenie
®
• Low voltage operation
®
Works with the iSteam®Mobile App to allow users to control steamroom operation from their local WiFi network.
3
8
1
1
6
B
lue Cap
Control P
igtail (8”)
ID Tag
Audio Pigtail
1
(
7
4
)
Wall location for
optional surface mount
f
or flush mount
W
all location
The iSteam controls are designed to be installed inside or outside the steam room but is primarily installed in­side the steam room. If the control is installed inside the steam room the control must be located:
• 4-5 feet above the floor
• In a location representative of the desired steam bathing temperatures near the bather seating area. Do not locate the control above or near the steam head or direct steam emissions.
• On a vertical wall
The control cable length is 30 feet. Insure that the con­trol and/ or steam generator are located accordingly. An optional 60 ft. cable is available if required, PN 104117-60. If the control is installed outside the steam room a Remote Temperature Probe Part Number iMSTS must be installed inside the steam room.
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
MODEL FINISH PROJECT INFORMATION
iSteam 2.0
 
Black White
Location:
Architect:
Engineer:
Contractor:
Submitted By:
Date:
Notes:
mr.steam
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
®
Sussman-Automatic Corp®
hello@mrsteam.com www.mrsteam.com
TS0036 REV 5.14
Page 4
mr.steam
®
Technical Specifications
AutoFlush
®
Box Contents
• AutoFlush Valve with Cord
• Installation instructions
Operation
The optional AutoFlush System fea­ture automatically drains the
®
Mr.Steam A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation.
Note:
has been installed, the AutoFlush will drain for ten minutes then refill with fresh water to begin the pre-heat cycle.
system following each use.
If the Express Steam®option
AutoFlush Shown Fully Assembled
Steam Generator
DO NOT TURN OR REMOVE THE DRAIN VALVE
(shown in the correct open position)
Drain Valve
AutoFlush Valve
Nipple
Plumb to Drain Line
Our exclusive AutoFlush® automatically and electronically drains the system,
®
providing CleanSteam... Every Time
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
MODEL PROJECT INFORMATION
MS 81500E
Notes:
mr.steam
mr.steam
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
Location:
Architect:
Engineer:
®
®
Sussman-Automatic Corp®
Sussman-Automatic Corp®
and introduces fresh water.
Contractor:
Submitted By:
Date:
hello@mrsteam.com www.mrsteam.com
hello@mrsteam.com www.mrsteam.com
TS0011 REV 5.14
Page 5
mr.steam
9”
1.5”
25”
®
Drip Pan MS 103867
Mr. Steam strongly recommends the use of a drain pan in the unlikely event of a plumbing leak.
Locate the drain pan on a solid level surface and place the steam generator inside the drain pan. Insure the steam generator is level.
All plumbing shall be performed by a qualified licensed plumber and in accor­dance with applicable national and local codes. Check local plumbing code for receptor, trap and vent requirements. Drain pans drain by gravity.
The drain pan is equipped with an integral 3
⁄4" NPT fitting.
Technical Specifications
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
MODEL PROJECT INFORMATION
MS 103867
Notes:
mr.steam
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
Location:
Architect:
Engineer:
®
Sussman-Automatic Corp®
Contractor:
Submitted By:
Date:
hello@mrsteam.com www.mrsteam.com
TS0012 REV 5.14
Page 6
mr.steam
®
Technical Specifications
CT-SteamStop
BOX CONTENT
• CT-SteamStop™Control Button
• Owner’s Manual
• 60’ CT-SteamStop Cable
FUNCTION
• Used to turn the steam room on and off from within the steam room without having to touch the main controller
®
• Works with both iTempoPlus
• Adhesive sticker for mounting located on the back of the button (non-supplied silicon is required to properly seal the wall opening).
and iSteam®controls
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
MODEL PROJECT INFORMATION
CT-SteamStop

Notes:
mr.steam
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
Location:
Architect:
Engineer:
®
Sussman-Automatic Corp®
Contractor:
Submitted By:
Date:
hello@mrsteam.com www.mrsteam.com
TS0065 12.14
Page 7
®
mr.steam
Technical Specifications
MSTS/iMSTS in Room Temperature Sensor
BOX CONTENT
• MSTS/iMSTS probe with wire attached
FUNCTION
• Used to accurately read the temperature inside the steam room and send it to the controller.
• MSTS is for use with the iTempo®or iTempoPlus®controls
• iMSTS is for use with the iSteam
1
4" Minimum
1
Maximum
2"
®
Control
Silicone Sealant
Probe
Finish Wall
Cable
INSTALLED REMOTE
SECTIONAL VIEW
FOR ILLUSTRATIVE PURPOSES ONLY.
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.
MODEL PROJECT INFORMATION
iMSTS


MSTS


Notes:
Location:
Architect:
Engineer:
IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
TEMPERATURE PROBE
Contractor:
Submitted By:
Date:
mr.steam
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
®
Sussman-Automatic Corp®
hello@mrsteam.com www.mrsteam.com
TS0055 12.14
Loading...