Mr. Steam ABUTLERXBPC Planning Guide

“It’s time to create my very own Home Sanctuary”
For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details and proper product placement.
It’s as easy as
All images in t his brochure a re for illustrative purposes only. Many images are altered for prese ntat ion purpose s. Contact MrSteam for complete product information . The prod ucts referenced in this brochure are for reside ntial applications only. Inst allation of residential products in non- residential or commerc ial settings (e.g., hotels, s pas, gyms, etc. ) may result in proper ty d amage or an inoperable or haz ardou s condition .
1 2 3
1
Generator SmartSizing
TM
To make sure you have just the right amount of steam for your new home
spa experience, use the chart below to help dene the shower size and nish materials to determine the correct steam generator size.
Or simply visit VirtualSpa.MrSteam.com, it will do the math for you and take you step-by-step through the whole steam shower selection process.
1 Measure length, width & height of the steam
enclosure (in feet):
Multiply
Length ___ x Width____ x Height ____
ROOM VOLUME =
3 Add all gures (from the left) to obtain the
Total Room Volume required
TOTAL VOLUME
Compare your TOTAL ADJUSTED ROOM VOLUME to the
Specication Char t for Residential (below) and select the
appropriate model.
2 Construction Materials:
For natural stones: Add 110% natural marble, stone, shale, glass block or concrete.
For ceramic or porcelain tile on cement board Add 40% or mortar bed.
Ceilings above 8 ft Add 15% (per foot, max 10 feet) For acrylic deduct 15%
Consult with a qualified designer, architect or contractor for steam room construction details.
For Illustrative purposes only. Consult with qualified designer,
architect or contractor for steamroom construction details
Residential Steam Generators Specifications Chart
Product
Dimensions
Volume (cu.ft.)
Model No.
Total Room Amps Water Usage* Shipping
kW
240/1PH Gallons Wt.(lbs.)
and proper product placement.
MS150E 101-150 6 25 0.80 30
MS225E 151-225 7.5 32 1.0 30
MS90E to 400E
14 1/2” x 14 3/4” x 6 3/4”
MS400E 226-360 9 38 1.2 30
MSSUPER1E 361-475 10 42 1.4 40
MSSUPER2E 476-575 12 50 1.6 40
MSSUPER3E 576-675 15 63 2.0 40
MSSUPER1E to 3E
17” x 18 1/2” x 7 7/8”
MX4E 676-875 20 84 2.7 67
MX5E 876-1075 24 100 3.2 67
MX6E 1076-1275 30 125 4.0 67
MAX Generators
27 5/8” x 20 3/4” x 7 7/8
* Water usage based on 20 minutes of operation.
Occasionally a steam room has unforeseeable or hidden construction that warrants special sizing or other consideration. MrSteam is not responsible if unconventional and/or unforeseeable materials or construction details result in a unit that does not operate to specication. Refer to the applicable MrSteam Installation, Operation &
Maintenance Manual, available at mrsteam.com, and consult a properly licensed contractor, architect and/or design professional.
Failure to do so may result in an inoperable or hazardous condition. See product packaging and labeling for additional important information.
MS90E up to 100 5 21 0.67 30