Mr. Steam AIRTBKPC, AIRTWHPC, ABUTLERLWHPN, ABUTLERLWHOR, AIRTBKBB Installation Manual

...
mr.steam
________________________________________________________________________________________________
®
Installation, Operating & Maintenance Instructions
AirTempo
Wireless Touch Control with Steamhead
Installation, Operation & Maintenance Manual
®
1
mr.steam
________________________________________________________________________________________________
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
®
Installation, Operating & Maintenance Instructions
IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS
WARNING
2.
!
of 16 to use this steambath.
WARNING
3. Steam is hot and can cause injury or
!
death if improperly used. Steam rooms contain steam and elevated temperatures. Please read and observe all warnings in this manual before installing or using a steam room.
4. To reduce the risk of injury:
WARNING
!
A. The wet surfaces of steam enclosures may be slippery.
Use care when entering or leaving.
B. The steam head is hot. Do not touch the steamhead and
avoid the steam near the steamhead.
C. Prolonged use of the steam system can raise excessively
the internal human body temperature and impair the body’s ability to regulate its internal temperature (hyper-
Do not permit children under the age
SAVE THESE INSTRUCTIONS
2
thermia). Limit your use of steam to 10-15 minutes until you are certain of your body’s reaction.
D. Excessive temperatures have a high potential
for causing fetal damage during the early months of pregnancy. Pregnant or possibly pregnant women should consult a physician regarding correct exposure.
E. Obese persons and persons with a history of
heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steambath.
F. Persons using medication should consult a
physician before using a steambath since some medication may induce drowsiness while other medications may affect heart rate, blood pressure and circulation
.
HYPERTHERMIA
temperature of the body reaches a level several degrees above the normal body temperature of
98.6° F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat; b) Failure to recognize the need to exit the steam-
bath; c) Unawareness of impending risk; d) Fetal damage in pregnant women; e) Physical inability to exit the steambath; and
f) Unconsciousness.
The use of alcohol, drugs, or medi-
WARNING
!
cation can greatly increase the risk of hyperthermia.
occurs when the internal
mr.steam
________________________________________________________________________________________________
®
Installation, Operating & Maintenance Instructions
READ ME FIRST!
WARNING
As you follow these instructions, you will notice warning and
!
caution symbols. This blocked information is important for the safe and ef­ficient installation and operation of the steambath system. These are types of potential hazards that may occur during installation and operation:
WARNING
Indicates a potentially hazardous situation, which could
!
result in death or serious injury.
Indicates a potentially hazardous situation, which may result
CAUTION
!
in minor or moderate injury or product damage.
IMPORTANT NOTE: This highlights information that is especially relevant to a problem-free installation.
All information in these instructions is based on the latest product informa­tion available at the time of publication. Sussman-Automatic Corporation reserves the right to make changes at any time without notice.
Table of Contents:
Important Safety Instructions ...................................2
Before Installing .......................................................4
Dimensional Information .........................................5
Installation ...............................................................6
Surface Mount & Glass Mount........................... 6-7
Wireless Receiver............................................... 7-8
Remote Temperature Probe ............................ 9-11
AirTempo Operating Instructions .................... 12-14
Battery Replacement .............................................15
System Status Codes .............................................16
Pairing, Care & Maintenance, Warranty ................16
Conformity & Compliances ..................................17
FCC Statements ....................................................18
Parts List & Technical Specs ..................................19
Glass Mount Mask ........................................... 20-21
Flush Mount Installation .................................. 22-23
Flush Mount Template ..........................................23
3
mr.steam
________________________________________________________________________________________________
Before Installing
Carefully inspect the control and packaging for shipping damage. In the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with any missing or damaged parts.
CAUTION
!
To avoid unintentional steambath operation, do not locate the control where other controls, accessories, shower heads, valves, body sprays or similar within the shower could cause confusion or interfere with the MrSteam control’s intended use and function.
Do not use any AirTempo
®
iGenie
controls without reading and understanding the respective Installation and Operation Manual and MrSteam steam generator Installation and Operation Manual. Failure to read and understand these instructions may result in an inoperative or hazardous installation.
WARNING
A peel and stick warning sticker is provided in the MrSteam steam
!
generator Installation, Operation and Maintenance Manual. This manual is pro­vided with every steam generator. The warning sticker must be read and perma-
nently afxed in a conspicuous location near the steam room. Failure to read and afx this warning sticker in a conspicuous location may result in serious injury or
death. Please call MrSteam at 800 767-8326 for a free replacement or if you have any questions regarding the warning sticker.
Install the AirTempo, iSteam, iTempo or iTempoPlus controls according to installa­tion instructions. Failure to install according to instructions will result in an inopera­tive control or hazardous overheating or inadequate heating of the steam room. If an AirTempo, iSteam, iTempo or iTempoPlus control is installed outside the steam
®
Installation Instructions
room a Remote Temperature Probe (PN MSTS) must be installed inside the steam room per instructions for the Remote Temperature Probe. Failure to install according to instructions will result in an inoperative control and overheating of the steam room.
Do not route AirTempo, iSteam, iTempoPlus, iTempo, Home Wizard or
!
WARNING
iGenie control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
Do not alter or modify any MrSteam product. Doing so may result in an
WARNING
!
®
, iSteam®, iTempoPlus®, iTempo®, HomeWizard® or
inoperative or hazardous installation and will void the warranty.
IMPORTANT NOTES:
• Turn power to the steam generator OFF before connecting the control to the generator. Failure to turn the power off will result in an inoperable control.
• Do not operate AirTempo, iTempoPlus, iTempo, Home Wizard or iGenie controls with
anything other than a MrSteam eTempo compatible steam generator. MrSteam resi­dential steam generators with serial numbers lower than 900000, or any other brand of steam generator are not to be operated with AirTempo, iTempoPlus, iTempo, Home Wizard or iGenie controls. Doing so may result in an inoperative installation.
• This document contains important safety, operation and maintenance information.
Leave this document with the homeowner. Do not discard this document.
• Discontinue use of the steam generator or control if the steam generator is damaged or otherwise not functioning properly. Doing so may result in an inopera­tive or hazardous installation.
• All drawings are for illustrative purposes only.
44
mr.steam
________________________________________________________________________________________________
®
Installation Instructions
Dimensional Information for the AirTempo
BOX CONTENTS:
• AirTempo Control
• Decorative Trim
• Cable (3 ft.)
• Wireless Receiver
• Batteries (2)
• Mounting Screws (2)
• Steamhead
• Tube of Silicone Sealant
• Surface Mount Bayonet
• Owner’s Manual
3-5/8”
3-5/8”
(shown with decorative trim)
3/4”
1-5/8”
4-7/8”
Wireless ReceiverAirTempo
Drawings for illustrative purposes only
7/8”
55
mr.steam
________________________________________________________________________________________________
®
Installation Instructions
Installation Instructions for AirTempo
STEP 1
Determine the desired installation location of the control. The AirTempo are designed to be installed inside or outside the steam room as a matter of personal preference. If the control is installed outside the steam room a Remote Temperature Probe part number MSTS must be installed inside the steam room.
IMPORTANT NOTE: See installation instructions for the MSTS Temperature Probe (pgs. 10-12) before rough-in or installation of control.
If the control is installed inside the steam room the control must be located:
• 4-5 feet above the oor near the bather seating area.
• On a vertical wall
The control features an integral temperature sensor. Locate the control in a location representative of the desired steam bathing temperatures. Do not locate the control above or near the steam head or direct steam emissions. Locating the controls near the steamhead or near direct steam emissions may result in poor steam room temperature control.
The control can be located up to 60 feet from the wireless receiver. Construction materials affect the communication between the control and receiver. Test the range of the AirTempo. It may be necessary to change the location of the wireless receiver to improve the range.
Contact MrSteam technical service for an optional 30 or 60 foot cable.
66
controls
STEP 2
The AirTempo control can be surface or ush mounted according to personal preference. Flush mount components are sold separately (104232RD & 104232SQ). Contact a MrSteam
representative if a ush mount kit is needed,
see page 22.
Surface Mount AirTempo
• Remove the surface mount bayonet from
the back of the AirTempo Control.
• Remove & discard the release paper to
expose the adhesive liner.
• Ensure the mounting surface is clean & dry.
• Place the bayonet on the wall in the desired
location.
IMPORTANT NOTE: Use the screw and anchor provided to secure
the bayonet to the wall as required for rough or uneven wall surfaces. The surface mount bayonet supports the weight of the AirTempo control.
mr.steam
________________________________________________________________________________________________
Mounting on Glass
When installing AirTempo on glass a peel and stick film is provided on pages 20-21 and may be used as a mask for a clean look from behind the glass.
®
Installation Instructions
Wireless Receiver Installation
The control can be located up to 60 feet from the wireless receiver. Construction materials may affect the communication between the control and the receiver. Test the range of the AirTempo. It may be necessary to change the location of the wireless receiver to improve the range. Contact MrSteam technical service for an optional 30 or 60 foot cable.
Using the 3 foot cable provided, plug one end into the steam bath generator and the other end into the AirTempo.
Attach the dongle on a wall adjacent to the steam generator using the screw provided.
Steam
Generator
Wireless Receiver
77
mr.steam
________________________________________________________________________________________________
IMPORTANT NOTE: Do not rest the dongle on the steam generator, the metal case of the generator may shield the RF signal.
®
Installation Instructions
The control features an integral temperature sensor. Locate the control in a location representative of the desired steam bathing temperatures. Do not locate the control above or near the steam head or direct steam emissions.
CAUTION
!
To avoid unintentional steambath operation, do not locate the control where other controls, accessories, shower heads, valves, body sprays or similar within the shower could cause confusion or interfere with the MrSteam control’s intended use and function.
8
3 ft. Cable Standard (optional 30’ or 60’ cable available)
Wireless Receiver
Steam Generator
AirTempo Control
Surface or Flush Mount
Steam Head
All drawings for illustrative purposes only.