Mr. Heater MHVFBF30TLPT, MHVFRD20LPBT, MHVFRD30LPBT, MHVFRD30LPT, MHVFBF20LPT, MHVFBF30LPBT, MHVFRD20LPT, MHVFBF20LPBT User Manual
OPERATING INSTRUCTIONS
AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
UNVENTED LP-GAS FIRED ROOM HEATER
Plaque Heaters
MHVFRD20LPBT
(BLOWER INCLUDED)
MHVFRD20LPT
(BLOWER SOLD SEPARATE)
MHVFRD30LPBT
(BLOWER INCLUDED)
MHVFRD30LPT
(BLOWER SOLD SEPARATE)
WARNING: If the information in this manual is not followed exactly, a re or explosion may result causing
property damage, personal injury, or loss of life.
- Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Shut o gas supply
• Do not try to light any appliance
• Do not touch an electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency, or the gas supplier.
Blue Flame Heaters
MHVFBF20LPBT
(BLOWER INCLUDED)
MHVFBF20LPT
(BLOWER SOLD SEPARATE)
MHVFBF30LPBT
(BLOWER INCLUDED)
MHVFBF30TLPT
(BLOWER SOLD SEPARATE)
WARNING: This is an unvented gas-red heater. It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion
and Ventilation section on page 4 of this manual.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to this manual for correct installation and operational procedures. For assistance or additional
information consult a qualied installer, service agency, or gas supplier.
This appliance may be installed in an aftermarket permanently manufactured (mobile) home, where not prohibited
by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with any other gas.
MR. HEATER, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 · 800-251-0001
2017 - CB
WARNINGS
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or
service this heater. Improper use of this heater can cause serious injury or death from burns, re, explosion,
electrical shock, and carbon monoxide poisoning.
WARNING: This appliance is equipped for propane
gas. Field conversion is not permitted.
WARNING: Do not use any accessory not
approved for use with this heater.
WARNING: Any change to this heater or its
controls can be dangerous.
• Do not place clothing or other ammable material on or near the appliance.
• Due to high temperatures, heater should be
kept out of trac and away from furniture and
draperies.
• Surface of heater becomes very hot when
running. Keep children and adults away
from hot surfaces to avoid burns or clothing
ignition. Heater will remain hot for a time
after shutdown. Allow heater surfaces to cool
before handling.
• Young children should be carefully supervised
when they are in the same room with heater.
• Make sure grille guard is in place before
running heater. If screen or grille guard is
removed for servicing it must be replaced prior
to operating the heater.
• Keep the appliance area clear and free from
combustible materials, gasoline, and other
ammable vapors and liquids.
• Children and adults should be alerted to the
hazard of high surface temperature and should
stay away to avoid burns or clothing ignition.
• Any safety screen or guard removed for
servicing an appliance must be replaced prior
to operating the heater
In order to provide the best service possible Mr. Heater is now giving you
more ways to get in touch with us:
WEBSITE: Mr. Heater’s full line of product are now at:
WWW.MRHEATER.COM
FACEBOOK: Find us on Facebook
TWITTER: Find us on twitter
YouTube: There are now informational videos on YouTube.
CAUTION: Never connect heater directly
to the Propane supply. This heater requires
an external regulator (not supplied). Install
the external regulator between the heater and
Propane/LP supply.
The installer must supply an external
regulator. The external regulator will reduce
the incoming gas pressure to between 11
and 14 inches of water. If you do not reduce
incoming gas pressure heater regulator
damage could occur. Install external regulator
with the vent pointing down. Pointing the
vent down protects it from freezing rain or
sleet.
Unvented LP-Gas Vent Free Room Heaters
Installation Instructions and Owner’s Manual
2
SPECIFICATIONS
**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**
MODEL
BTU (Available) 18,00030,000 20,00030,000
Type of Gas LP-Gas Only LP-Gas Only LP-Gas Only LP-Gas Only
1. 20,000 BTU or 30,000 BTU may not be installed
in a bedroom or bathroom, or any place where a
strong wind would shut down the appliance.
2. This heater needs outside ventilation air to run
properly. The Oxygen Depletion Sensor (ODS)
safety shuto system shuts down the heater if not
enough fresh air is available. See Fresh Air for Combustion and Ventilation, pages 5 through 6.
WARNING: An unvented heater having an input
of more than 10,000 Btu/hr (2 931W) shall not be
installed in a bedroom or bathroom.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will insure that enough air for
proper combustion enters the heater.
4. If heater shuts o, do not relight until you provide
fresh, outside air. If heater keeps shutting o, it
requires servicing.
5. Turn o and unplug heater and let cool before
servicing. Only a qualied service person should
service and repair heater.
6. Do not run heater:
• Where ammable liquids or vapors are used or stored
MHVFRD30TB /
MHVFRD30T LP
Clearances: inches (mm)
the control system and any gas control which has
been underwater.
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10. Always run heater with control knob in a locked
position. Never set control knob between locked
positions. Poor combustion and higher levels of
carbon monoxide may result if control knob is left
between locked positions.
DANGER: Carbon monoxide poisoning may lead to
death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble
the u, with headaches, dizziness, or nausea. If you
have these signs, the heater may not be working
properly. Get fresh air at once! Have heater serviced.
Some people are more aected by carbon monoxide
than others. These include pregnant women, persons
with heart or lung disease or anemia, those under the
inuence of alcohol, and those at high altitudes.
Propane/LP Gas:
Propane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect
a Propane/LP gas leak. However the odor added to
MHVFBF20TB /
MHVFBF20T LP
MHVFBF30TB /
MHVFBF30T LP
propane/LP gas may be present even though no odor
• During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner
or similar products, turn heater o. If heated the
exists. Make certain you read and understand all
warnings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.
vapors from these products may create a white
powder residue within burner box or on adjacent
walls or furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualied service technician to
inspect the room heater and to replace any part of
Unvented LP-Gas Vent Free Room Heaters
Installation Instructions and Owner’s Manual
3
Product Features
Fan Blower
Switch
(located on back
of heater)
Burners
Ignitor Button
Control Knob
FRESH AIR FOR COMBUSTION AND
VENTILATION
WARNING: This heater shall not be installed in a
room or space unless the required volume of indoor
combustion air is provided by the method described in
the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Read the following instructions to insure proper fresh air
for this and other fuel-burning appliances in your home.
Grill
Heater
Cabinet
Front Panel
Figure 1
SAFETY DEVICE
This heater has a pilot with an Oxygen Depletion Sensor (ODS) safety shut o system. The ODS/pilot shuts
o the heater if there is not enough fresh air.
IGNITION SYSTEM / BATTERY INSTALLATION
– The heater is equipped with an electronic manual
ignitor. This system requires no matches, or other
source to light heater, but does require one AA battery
to operate ignitor. (AA Battery included).
To install or replace battery unscrew the ignitor cap
(red button), insert battery positive (+) terminal up
and replace cap.
(AA Battery included)
THERMOSTATIC CONTROL
These heaters have a control valve with a thermostat
sensing bulb. This results in the greatest heater comfort
and may result in lower bills.
BLOWER FAN CONTROL SWITCH OPERATION
These heaters also include an electrical blower. The
blower switch has three positions: MANUAL, OFF and
AUTO. In AUTO, the blower will turn on and o as the
heater cycles on and o. On MANUAL, the blower will run
continuously. To turn blower o, use the OFF position.
LOCAL CODES
Install and use heater with care.
Installation must conform to local codes or in the
absences of local codes, use the latest edition of
National Fuel Gas Code ANSI Z223.1/NFPA 54.
UNPACKING
1. Remove heater from carton.
2. Remove all protective packaging applied to
heater for shipment.
3. Check heater for any shipping damage. If
heater is damaged, promptly inform dealer
where you bought heater.
ESTABLISHING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas
Code, NFPA 54/ ANSI Z223.1, Section 5.3, Air for
Combustion and Ventilation. All spaces in homes fall
into one of the three following ventilation classications:
1. Unusually Tight Construction
2. Unconned Space
3. Conned Space
This heater must not be installed in a conned space
or unusually tight construction unless provisions are
provided for adequate combustion and ventilation air.
The information on pages 4 through 6 will help you
classify your space and provide adequate ventilation.
Unusually Tight Construction
If your home meets all of the three following criteria you
must provide additional fresh air. See Ventilation Air from Outdoors, page 6.
Unusually tight construction is dened as construction
where:
a. Walls and ceilings exposed to the outside
atmosphere have a continuous water vapor retarder
with a rating of one perm (6 x 10
-11
kg per pa-sec-m2)
or less with openings gasketed or sealed and
b. Weather stripping has been added on operable
windows and doors, and
c. Caulking or sealants are applied to areas such
as joints around windows and door frames,
between wall-ceiling joints, between wall panels, at
penetrations for plumbing, electrical, and gas lines,
and at other openings.
If your home does not meet all of the three criteria
above, see Determine the Type of Heater Location
Space, page 5.
Conned Space and Unconned Space
The National Fuel Gas Code, NFPA 54/ ANSI Z223.1
denes a conned space as a space whose volume is
less than 50 cubic feet per 1,000 Btu per hour (4.8 m3
per kW) of the aggregate input rating of all appliances
installed in that space, and an unconned space as a
space whose volume is not less than 50 cubic feet per
1,000 Btu per hour (4.8 m3 per kW) of the aggregate
input rating of all appliances installed in that space.
Rooms communicating directly with the space in which
the appliances are installed*, through openings not
furnished with doors, are considered a part of the
unconned space.
Unvented LP-Gas Vent Free Room Heaters
Installation Instructions and Owner’s Manual
4
*Adjoining rooms are communication only if there
are door less passageways or ventilation grills
between them.
DETERMINING THE TYPE OF HEATER
LOCATION SPACE:
Use this method to determine if you have a conned or
unconned space.
Note: the space includes the room in which you
install heater plus any adjoining rooms with doorless
passageways or ventilation grills between the rooms.
1. Find the volume of the space by multiplying room
length x width x height.
Example: Space size 18ft (length) x 18ft. (width) x 8ft.
(height) = 2592
If additional ventilation to adjoining room is supplied
with grills or openings, add the volume of these rooms
to the total volume of the space.
2. Divide the space volume by 50 cubic feet to deter-
mine the maximum Btu/hr the space can support.
Example: 2592 cu.ft. (volume of space) / 50 cu.ft. =
51.8 or 51,800 (maximum Btu/hr the space
can support)
WARNING: If the area in which the heater may be
operated is smaller than dened as an unconned
space or if the building is of unusually tight
construction, provide adequate combustion and
ventilation air by the methods described in the
National Fuel Gas Code, NFPA 54/ ANSI Z223.1,
Section 5.3 or applicable local codes.
3. Add the Btu/hr of all the fuel-burning appliances
in the space such as, Vent–free heater, Gas water
heater, Gas furnace, Vented gas heater, Gas replace logs, and Other gas appliances*
*Do not include direct-vent gas appliances. Directvent draws combustion air from the outdoors and
vents to the outdoors.
Example: Gas water heater 40,000 Btu/hr
Vent Free Heater + 20,000 Btu/hr
Total =60,000 Btu/hr
4. Compare the maximum Btu/hr the space can support
with the actual amount of Btu/hr used.
Example: 51,800 Btu/hr (maximum Btu/hr the
space can support)
60,000 Btu/hr (Actual amount of Btu/hr
used)
The space in the above example is a conned
space because the actual Btu/hr used is more than
the maximum Btu/hr the space can support.
You must provide additional fresh air. Your options
are as follows:
A. Rework worksheet, and the space of an adjoining
room. If the extra space provides an unconned
space, remove door to adjoining room or add
ventilation grills between the rooms. See Ventilation
Unvented LP-Gas Vent Free Room Heaters
Air From Inside Building (Figure 2).
B. Vent room directly to the outdoors. See Ventilation
Air From Outdoors (Figure 3).
C. Install a lower Btu/hr heater if lower Btu/hr size
makes room unconned.
If actual Btu/hr used is less than the maximum Btu/
hr the space can support, the space is an unconned space. You will need no additional fresh air
ventilation.
VENTILATION AIR
Ventilation from Inside Building
This fresh air would come from an adjoining unconned
space. When ventilation to an adjoining unconned
space, you must provide two permanent openings:
one within 12” of the ceiling and one within 12” of
the oor on the wall connecting the two spaces (see
options 1 & 2 of g. 2). You can also remove door into
adjoining room (see option3, g 2). Follow the National
Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3,
Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
12”
Ventilation
Gills into
Adjoining
Room Option 1
Or remove
door into
Adjoining
Room Option 3
Ventilation Gills into
Adjoining Room - Option 2
12”
Figure 2.
VENTILATION AIR
OUTLET AIR
OUTLET
AIR
INLET
AIR
VENTILATION CRAWL SPACE
VENTILATED
ATTIC
TO CRAWL
SPACE
Figure 3.
Installation Instructions and Owner’s Manual
5
TO ATTIC
WARNING: Rework worksheet, adding the space
of the adjoining unconned space. The combined
space must have enough fresh air to supply all appliance in both spaces.
Ventilation from Outdoors
If necessary provide extra fresh air by using ventilation
grills or ducts. Connect these items directly to the
outdoors or spaces open to the outdoors. These
include attics* and crawl spaces. Follow the National
Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3,
Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
*IMPORTANT: Do not provide openings for inlet or
outlet into attic. If attic has a thermostat-controlled
power vent, heated air entering the attic will activate
the power vent.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is benecial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Fresh Air
for Combustion and Ventilation, pages 5 through 6.
INSTALLATION
WARNING: Any change to this heater or its
controls can be dangerous.
NOTICE: This appliance is intended for supplemental
heating. Use this heater along with your primary heating
system. Do not install this heater as your primary heat
source. If you have a central heating system, you may
run system’s circulating blower while using heater. This
will help circulate the heat throughout the house. In the
event of a power outage, you can use this heater as
your primary heat source for the duration of the outage.
WARNING: A qualied service person must install
heater. Follow all local codes.
CHECK GAS TYPE
Use only LP-gas. If your gas supply is not LP-gas, do
not install heater. Call dealer where you bought heater
for proper type heater.
THIS INSTALLATION REQUIRES:
Before installing heater, make sure you have the items
listed below:
• Piping (check local codes)
• Sealant (resistant to LP_Gas)
• Equipment shuto valve*
*A CSA/AGA certied equipment shuto valve with
1/8” NPT tap is an acceptable alternative to test gauge
connection. Purchase a CSA/AGA certied equipment
shuto valve from your dealer.
LOCATING HEATER
This heater is designed to be mounted on the wall. The
heater can also be located on a non-combustible oor,
away from a wall by using the oor mounting stands
included with the heater. If installed on combustible
ooring such as carpeting, tile or other combustible
material other than wood ooring, the heater must be
placed on a wood panel the full width and depth of the
appliance.
For convenience and eciency, install the heater:
• Where there is easy access for operation,
inspection, and service
• In the coldest part of the room.
• If planning to use fan, locate heater near an
electrical outlet.
CAUTION: If you install the heater in a home garage:
Heater pilot and burner must be at least 18 inches
above oor . Locate heater where moving vehicle will
not hit it.
CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
covering or operating heater where impurities (such
as tobacco smoke, aromatic candles, cleaning uids,
oil or kerosene lamps, etc.) are present in the air may
discolor walls.
WARNING: Never install the heater:
• In a bedroom (RD20LPT, RD30LPT, BF20LPT
or BF30LPT)
• In a recreational vehicle ·.
• Where curtains, furniture, clothing, or other
ammable objects are less than 36 inches from
the front, top, or sides of the heater.
• As a replace insert
• In high-trac areas
• In windy or drafty areas
WARNING: Heater must be mounted to maintain
the minimum clearances shown in Figure 4. If
possible, provide greater clearances from the oor,
ceiling, and joining walls.
• Ground joint union
• Test gauge connection*
• Sediment trap
• Tee joint
• Pipe wrench
Unvented LP-Gas Vent Free Room Heaters
Installation Instructions and Owner’s Manual
6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.