READ INSTRUCTIONS CAREFULLY: YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS Read and
follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has
not read these instructions to assemble, light, adjust or operate the heater.
MHVFRD10NG
MHVFBF10NG
UNVENTED NATURAL GAS FIRED ROOM HEATER
Plaque Heaters
MHVFRD10NG
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury, or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for
Combustion and Ventilation section on page 4 of this manual.
Blue Flame Heaters
MHVFBF10NG
This appliance may be installed in an aftermarket permanently manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is
not convertible for use with any other gas.
Mr. Heater, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 · 800-251-0001
Unvented Natural Gas Fired Room Heater
Installation Instructions and Owner’s Manual
1
WARNING: FIRE, EXPLOSION, AND ASPHYXIATION HAZARD
Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to this manual for correct installation and operational procedures. For
assistance or additional information consult a qualified installer, service agency, or gas supplier.
Read and follow instructions and precautions in User’s Information Manual provided with this
heater.
Due to high temperatures, heater should be
kept out of traffic and away from furniture and
DANGER
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
WARNING: Do not use
a blower insert, heat exchanger
insert or other accessory not
approved for use with this heater.
WARNING: THIS PRODUCT CAN EXPOSE YOU TO
CHEMICALS INCLUDING LEAD AND LEAD COMPOUNDS, WHICH ARE
KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH
DEFECTS OR OTHER REPRODUCTIVE HARM. FOR MORE INFORMATION
VISIT WWW.P65WARNINGS.CA.GOV
WARNING: This
appliance is equipped for Natural
gas. Field conversion is not
permitted.
draperies.
Do not place clothing or other flammable material
on or near the appliance.
Children and adults should be alerted to the
hazard of high surface temperature and should
stay away to avoid burns or clothing ignition.
Young children should be carefully supervised
when they are in the same room with heater.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
If the barrier becomes damaged, the barrier shall
be replaced with the manufacturer’s barrier for
this appliance.
Any safety screen or guard removed for servicing
an appliance must be replaced prior to operating
the heater.
Installation and repair should be done by a
qualified service person. The appliance should
be inspected before use and at least annually
by a professional service person. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is
imperative that control compartments, burners,
and circulating air passageways of the appliance
be kept clean.
SOCIAL MEDIA
In order to provide the best service possible Mr. Heater is now giving you more ways to get in touch with us:
WEBSITE: Mr. Heater’s full line of product are now at: www.mrheater.com
FACEBOOK: Find us on Facebook
TWITTER: Find us on twitter
YouTube: There are now informational videos on Youtube.
Type of Gas Natural Gas Only
Ignition Piezo
Manifold Pressure 4.5 Inches of Water
Inlet Gas Pressure (Maximum) 14 Inches of Water
Inlet Gas Pressure (Minimum) 7 Inches of Water
Thermostatic Control No
Top 36” (91.4 cm)
Sides 10” (25.4 cm)
SPECIFICATIONS
Clearances: inches (mm)
Floor (min. to top of carpet) 3” (76.2 cm)
Fabric / flammable objects 36” (91.4 cm)
**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**
PRECAUTIONS:
1. Either of the 10,000 BTU (2931 W) units (the
MHVFRD10NG or the MHVFBF10NG) may be installed
in a bedroom, but shall not be installed in a bathroom
or any place where a strong wind would shut down the
appliance.
2. This heater needs outside ventilation air to run properly.
The Oxygen Depletion Sensor (ODS) safety shutoff
system shuts down the heater if not enough fresh air is
available. See Fresh Air for Combustion and Ventilation,
page 4.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will ensure that enough air for
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide fresh,
outside air. If heater keeps shutting off, it requires
servicing.
5. Turn off and let cool before servicing. Only a qualified
service person should service and repair heater.
6. Do not run heater:
• Where flammable liquids or vapors are used or stored
• During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner or
similar products, turn heater off. If heated the vapors
from these products may create a white powder residue
within burner box or on adjacent walls or furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualified service technician to inspect
the room heater and to replace any part of the control
system and any gas control which has been underwater.
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10. Always run heater with control knob in a locked
position. Never set control knob between locked
positions. Poor combustion and higher levels of carbon
monoxide may result if control knob is left between
locked positions.
DANGER: Carbon monoxide poisoning may lead to
death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble the flu,
with headaches, dizziness, or nausea. If you have these
signs, the heater may not be working properly. Get fresh
air at once! Have heater serviced. Some people are more
affected by carbon monoxide than others. These include
pregnant women, persons with heart or lung disease or
anemia, those under the influence of alcohol, and those at
high altitudes.
Natural Gas:
Natural gas is odorless. An odor making agent is added to
natural gas. The odor helps you detect a natural gas leak.
However, the odor added to the gas can fade. Gas may
be present even though no odor exists. Make certain you
read and understand all warnings. Keep this manual for
reference. It is your guide to safe and proper operation of
this heater.
Product Features
Control Knob
Burners
Grill
Heater
Cabinet
Front Panel
Figure 1
Unvented Natural Gas Fired Room Heater
Installation Instructions and Owner’s Manual
3
SAFETY DEVICE
This heater has a pilot with an Oxygen Depletion Sensor
(ODS) safety shut off system. The ODS/pilot shuts off the
heater if there is not enough fresh air.
IGNITION SYSTEM
PIEZO: The heater is equipped with a piezo manual ignitor.
This system requires no matches, batteries, or other source
to light heater.
LOCAL CODES
Install and use heater with care.
Installation must conform to local codes or in the absences
of local codes, use the latest edition of National Fuel Gas
Code, ANSI Z223.1/NFPA 54.
UNPACKING
1. Remove heater from carton.
2. Remove all protective packaging applied to heater
for shipment.
3. Check heater for any shipping damage. If heater
is damaged, promptly inform dealer where you
bought heater.
c. Caulking or sealants are applied to areas such as joints
around windows and door frames, between wall-
ceiling joints, between wall panels, at penetrations
for plumbing, electrical, and gas lines, and at other
openings.
If you home does not meet all of the three criteria above,
see Determining the Type of Heater Location Space, below.
Confined Space and Unconfined Space
The National Fuel Gas Code, NFPA 54/ ANSI Z223.1
defines a confined space as a space whose volume is less
than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW)
of the aggregate input rating of all appliances installed in
that space, and an unconfined space as a space whose
volume is not less than 50 cubic feet per 1,000 Btu per
hour (4.8 m3 per kW) of the aggregate input rating of all
appliances installed in that space. Rooms communicating
directly with the space in which the appliances are
installed*, through openings not furnished with doors, are
considered a part of the unconfined space.
*Adjoining rooms are communication only if there are
doorless passageways or ventilation grills between
them.
FRESH AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall not be installed in a confined
space or unusually tight construction unless provisions are
provided for adequate combustion and ventilation air. Read
the following instructions to insure proper fresh air for this
and other fuel-burning appliances in your home.
ESTABLISHING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code,
NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion
and Ventilation. All spaces in homes fall into one of the
three following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
This heater must not be installed in a confined space
or unusually tight construction unless provisions are
provided for adequate combustion and ventilation air. The
information on pages 4 and 5 will help you classify your
space and provide adequate ventilation.
Unusually Tight Construction
If your home meets all of the three following criteria you
must provide additional fresh air. See Ventilation from
Outdoors, page 5.
Unusually tight construction is defined as construction
where:
a. Walls and ceilings exposed to the outside atmosphere
have a continuous water vapor retarder with a rating
of one perm (6 x 10
openings gasketed or sealed and
b. Weather stripping has been added on operable windows
and doors, and
- 11
kg per pa-sec-m2) or less with
DETERMINING THE TYPE OF HEATER LOCATION
SPACE:
Use this method to determine if you have a confined or
unconfined space.
Note: the space includes the room in which you
install heater plus any adjoining rooms with doorless
passageways or ventilation grills between the rooms.
1. Find the volume of the space by multiplying room length
x width x height.
Example: Space size 18ft (length) x 18ft. (width) x 8ft.
(height) = 2592
If additional ventilation to adjoining room is supplied with
grills or openings, add the volume of these rooms to the
total volume of the space.
2. Divide the space volume by 50 cubic feet to determine
the maximum Btu/hr the space can support.
Example: 2592 cu.ft. (volume of space) / 50 cu.ft. =
51.8 or 51,800 (maximum Btu/hr the space
can support)
WARNING: This heater shall not be installed in a
room or space unless the required volume of indoor
combustion air is provided by the method described
in the National Fuel Gas Code, ANSI Z223.1/NFPA
54, the International Fuel Gas Code, or applicable
local codes
Unvented Natural Gas Fired Room Heater
4
Installation Instructions and Owner’s Manual
3. Add the Btu/hr of all the fuel-burning appliances in the
space such as, Vent–free heater, Gas water heater, Gas
furnace, Vented gas heater, Gas fireplace logs, and
Other gas appliances*
*Do not include direct-vent gas appliances. Direct-vent
draws combustion air from the outdoors and vents to
the outdoors.
Example:
Gas water heater 40,000 Btu/hr
Vent Free Heater + 20,000 Btu/hr
Total =60,000 Btu/hr
4. Compare the maximum Btu/hr the space can support
with the actual amount of Btu/hr used.
Example: 51,800 Btu/hr (maximum Btu/hr the space can support)
60,000 Btu/hr (Actual amount of Btu/hr used)
The space in the above example is a confined space
because the actual Btu/hr used is more than the
maximum Btu/hr the space can support.
You must provide additional fresh air. Your options
are as follows:
A. Rework worksheet, and the space of an adjoining room.
If the extra space provides an unconfined space, remove
door to adjoining room or add ventilation grills between
the rooms. See Ventilation From Inside Building (Fig. 2)
B. Vent room directly to the outdoors. See Ventilation
From Outdoors (Fig. 3).
C. Install a lower Btu/hr heater if lower Btu/hr size makes
room unconfined.
If actual Btu/hr used is less than the maximum Btu/
hr the space can support, the space is an unconfined
space. You will need no additional fresh air ventilation.
VENTILATION AIR
Ventilation from Inside Building
This fresh air would come from an adjoining unconfined
space. When ventilation to an adjoining unconfined space,
you must provide two permanent openings: one within
12” of the ceiling and one within 12” of the floor on the
wall connecting the two spaces (see options 1 & 2 of figure
2). You can also remove door into adjoining room (see
option3, fig 2). Follow the National Fuel Gas Code NFPA
54/ ANSI Z223.1, Section 5.3, Air for Combustion and
Ventilation for required size of ventilation grills or ducts.
WARNING: Rework worksheet, adding the space of
the adjoining unconfined space. The combined space
must have enough fresh air to supply all appliance in
both spaces.
Ventilation from Outdoors
If necessary provide extra fresh air by using ventilation grills
or ducts. Connect these items directly to the outdoors or
spaces open to the outdoors. These include attics* and
crawl spaces. Follow the National Fuel Gas Code NFPA
54/ ANSI Z223.1, Section 5.3, Air for Combustion and
Ventilation for required size of ventilation grills or ducts.
Unvented Natural Gas Fired Room Heater
(30.5 cm)12”
Ventilation
Gills into
Adjoining
Room Option 1
Or remove
door into
Adjoining
Room Option 3
Ventilation Gills into
Adjoining Room - Option 2
12” (30.5 cm)
Figure 2
VENTILATION AIR
OUTLET AIR
OUTLET
AIR
INLET
AIR
VENTILATION CRAWL SPACE
VENTILATED
ATTIC
Figure 3.
*IMPORTANT: Do not provide openings for inlet or
outlet into attic. If attic has a thermostat-controlled power
vent, heated air entering the attic will activate the power
vent.
IMPORTANT: Vent-free heaters add moisture to the
air. Although this is beneficial, installing heater in rooms
without enough ventilation air may cause mildew to form
from too much moisture. See Fresh Air for Combustion
and Ventilation, pages 4 through 5.
INSTALLATION
WARNING: Any change to this heater or its controls
can be dangerous.
NOTICE: This heater is intended for the use as
supplemental heat. Use this heater along with your
primary heating system. Do not install this heater as your
primary heat source. If you have a central heating system,
you may run system’s circulating blower while using heater.
This will help circulate the heat throughout the house. In
the event of a power outage, you can use this heater as
your primary heat source for the duration of the outage.
WARNING: A qualified service person must install
heater. Follow all local codes.
Installation Instructions and Owner’s Manual