INDOOR GAS LAMP
Model #
MHGLLP B
OPTIONAL CHANDELIER KIT
MHGLLP G
READ INSTRUCTIONS CAREFULLY: Read all information and instructions, including Gas lamp
Warning Tag attached to light, before installation or use. Retain this guide for future reference.
AVAILABLE CONFIGURATIONS (LAMPS NOT INCLUDED)
Single lamp Corner double lamp
Balanced double lamp
PARTS LIST AND ASSEMBLY INSTRUCTIONS
For corner double and triple
lamp configurations
1
2
3
4
5
6
9
7
8
Connect 1/8” plug to •
2-outlet distributor.
Attach the 3/8” pipe to •
2-outlet distributor.
Insert 3/8” pipe through ceiling •
canopy and canopy holding ring.
Tighten the canopy holding screw.•
Attach the 3-outlet distributor •
to bottom of 3/8” pipe.
Use 3 long nipples for triple •
lamp or 2 long nipples for
corner double lamp.
Attach lamps (not included) •
elbow joint(s)
Connect top distributor •
to gas line.
For balanced double and
single lamp configurations
Connect 2 1/8” plugs to •
3-outlet distributor.
Attach the 3/8” pipe to •
3-outlet distributor.
Insert 3/8” pipe through ceiling •
canopy and canopy holding ring.
Tighten the canopy holding screw.•
Attach the 2-outlet distributor •
to bottom of 3/8” pipe.
Use 2 short nipples for •
balanced double lamp or 1
short nipple for single lamp.
Attach lamps (not included) •
to elbow joint(s)
Connect top distributor •
to gas line.
Triple lamp
Maintain a minimum of 4”clearance to ceiling,
wall, or any other combustible surface.
Gas supply (1/8 NPT female) 3/8”
tubing is recommended.
Before operation, check for any possible
leaks and tighten all connections.
Parts List
Item
No.
1 3 20360 1/8” NPT pipe plug
2 1 20398 2-outlet distributor
3 1 20373 Ceiling canopy
4 1 20387 Canopy holding ring
5 1 20374 Canopy holding screw
6 1 20355 3/8” x 16” pipe
7 1 20378 3-outlet distributor
8 3 20377 1/8” NPT x 13/16”
9 3 20348 1/8” FPT x 1/8” MPT
Stock
No.
No.
3 20379 1/8” NPT x 1 1/2”
Description
Used to plug
unused ports
Used for balanced
double lamp
configurations
Conceals opening
in ceiling
Used for corner
double and triple
lamp configurations
short nipple
Used for double lamp
configurations
long nipple
Used for triple lamp
configurations
elbow joint
Connects into
valve of light
ENERCO GROUP INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-916-3000 20303 Rev. A 07/08