Mr. Heater MH170QFAVT User Manual

OPERATING INSTRUCTIONS AND OWNER’S MANUAL
FORCED AIR PROPANE
CONSTRUCTION HEATER
Model #
MH170QFAVT
Featuring NEW QUIET BURNER TECHNOLOGY
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
· Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
· An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
· WHAT TO DO IF YOU SMELL GAS
Do not try to light appliance.
Shut off gas to appliance.
· Service must be performed by a qualified service agency.
This is an unvented gas-fired portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to page 3.
www.mrheater.com 800-251-0001
2016
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX­IDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNINGS:
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UN­KNOWN CHEMICALS.
WARNING: Combustion by-products produced when using this product contain carbon monoxide, a chemical
known to the State of California to cause cancer and birth defects (or other reproductive harm).
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects
or other reproductive harm.
CONTENTS
Specifications .................................................................... 2
Operating Precautions ....................................................... 3
Safety Precations ............................................................... 3
Odor Fade Warning .......................................................... 4
Operating Instructions ......................................................4
Storage & Service .............................................................5
Lighting Instructions ......................................................... 5
Wiring Diagram 170 QFAVT ............................................... 6
Parts List Q170 FAVT ......................................................... 7
Exploded View Drawing Q170 FAVT ................................... 7
Wiring Diagram Q170 FAV (No Thermostat) ....................... 8
GENERAL INFORMATION
RETAIN THIS MANUAL FOR FUTURE REFERENCE. FOR QUESTIONS, PROBLEMS, MISSING PARTS BEFORE
RETURNING TO RETAILER PLEASE CALL WITH MODEL NUMBER AND SERIAL NUMBER OF HEATER:
1-800-321-0001
MONDAY-FRIDAY 8-5 PM EASTERN TIME OR EMAIL USING THE MR. HEATER WEBSITE:
WWW.MRHEATER.COM
SPECIFICATIONS
MODEL NO. ................................................ 170QFAVT
GAS TYPE ....................................................... Propane
BTU RATING. ..........................125,000-170,000 BTU/hr
GAS SUPPLY PRESSURE TO REGULATOR Maximum: Bottle Pressure, Minimum: 20 psig (137.9
kPa)
REGULATOR OUT...............................20 psi (137.9 kPa)
ELECTRICAL INPUT ........................115V, 60 Hz, 1±, 3a
IGNITION....................... Direct Spark, interrupted type
PRIMARY FLAME CONTROL ... SolidState,10-15 sec. timing
HIGH TEMPERATURE CONTROL .......................
Minimum Ambient Temp. Rating: 0°F (-17.8°C)
FUEL CONSUMPTION .......................... 5.8 - 7.9 lbs/hr
(2.6 - 3.6 kg/hr)
FUEL ORIFICE PORT NO.: .................. 18
HEATED AIR OUTPUT: ......... 450 CFM (12.74 CU M/M)
In order to provide the best service possible Mr. Heater is now giving you more ways to get in touch with us:
FACEBOOK: Find us on facebook TWITTER: Find us on twitter
YOUTUBE: There are now informational videos on YouTube. WEBSITE: Mr. HeaterÊs full line of product are now at WWW.MRHEATER.COM
240°F (116°C)
2
Force-Air Propane Construction HeaterOperating Instructions and OwnerÊs Manual
OPERATING PRECAUTIONS
This is a propane, direct-fired, forced air heater. ItÊs intended use is primarily temporary heating of buildings under construction, alteration or repair.
Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the floor, collecting there with the surrounding air, forming a potentially explosive mixture. Obviously, propane leaks should be avoided, so set up the propane supply with utmost care. Read enclosed Odor Fade and Propane Sheet for additional information about detecting propane leaks. Leak check new connections or reconnections with a soap and water solution and follow all connection instructions herein. Also, ask your propane dealer for advice on the propane application and supply installation and ask him to check it if there are any questions.
This heater was designed and certified for use as a construction heater in accordance with ANSI Standard Z83.7/ CGA 2.14. Check with your local fire safety authority if you have any questions about your applications. Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these.
Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. CO can build up in a heated space and failure to provide adequate ventilation could result in death.
Uif!tznqupnt!pg!jobefrvbuf!wfoujmbujpo!bsf;
headache
dizziness
• burning eyes and nose
nausea
• dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating instructions.
Forced Air means that a blower or fan pushes the air through the heater. Proper combustion depends upon this air flow; therefore, the heater must not be revised, modified or operated with parts removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater.
SAFETY PRECAUTIONS
1. Check the heater thoroughly for damage. DO NOT operate a damaged heater.
2. DO NOT modify the heater or operate a heater which has been modified from its original condition.
3. Use only propane gas.
4. Use only VAPOR WITHDRAWAL propane supply. If there is any question about vapor withdrawal, ask your propane dealer.
5. Mount the propane cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them from damage.
6. Locate propane containers at least (USA) 7 ft. (2.13m), (Canada) 10 ft. (3m) from the heater and do not direct exhaust toward containers.
7. IMPORTANT Use only the hose and regulator assembly provided with the heater. Match the color stripe on the hang tag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater.
8. For indoor use only. Area must be well ventilated. Figure 1. (also see „Operating Precautions‰).
9. If at any time gas odor is detected, IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected. Read enclosed Odor fade and Propane Sheet for additional information about detecting propane leaks.
10. Install the heater such that it is not directly exposed to water spray, rain and/or dripping water.
11. Maintain minimum clearance from normal combustible material (like paper). Figure 2.
12. Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition.
13. Operate only on a stable, level surface.
14. Do not use with duct work. Do not restrict inlet or exit.
15. Use only the electrical power specified. The electrical connection and grounding must comply with National Electrical Code - ANSI/NFPA 70 (USA) and CSA C22.1 Canadian Electrical Code, Part 1 (Canada).
16. Use only a properly grounded 3-prong receptacle or extension cord.
17. Do not move, handle or service while hot or burning.
18. Do not adjust the heater combustion tube elevation while heater is running or hot. Adjustments to elevation should only be made after the heater has cooled to touch.
19. Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.
When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved.
Figure 1
VENTILATION: Minimum openings required
Opening Opening Heater near floor near ceiling
Forced air (MH170QFAVT) 3 ft2 3 ft
Force-Air Propane Construction Heater Operating Instructions and OwnerÊs Manual
2
Figure 2: MINIMUM CLEARANCE: From normal combustible materials
Clearance Forced Air 170FQAVT
From floor .......................................................0 ft
From outlet .....................................................6 ft
From sides ...................................................... 2 ft
From top .........................................................3 ft
Locate 10 ft. from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action.
3
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
• Do not use this heater for heating human living quarters.
• Do not use in unventilated areas.
• The flow of combustion and ventilation air must not be obstructed.
• Proper ventilation air must be provided to support the combustion air requirements of the heater being used.
• Refer to the specification section of the heaterÊs manual, heater data plate, or contact the Factory to determine combustion air ventilation requirements of the heater.
• Lack of proper ventilation air will lead to improper combustion.
• Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing.
FUEL GAS ODOR
LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks. If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
Get everyone out of the building and away from the area immediately.
Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas.
Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas.
Use your neighborÊs phone and call your fuel gas supplier and your fire department. Do not re-enter the building or area.
Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier.
FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you.
ODOR FADING - NO ODOR DETECTED
Some people cannot smell well. Some people cannot smell the odor of the man-made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases.
Learn to recognize the odor of propane (LP) gas and natural gas. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.
Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor.
The odorant in propane (LP) gas and natural gas is
colorless and the intensity of its odor can fade under some circumstances.
If there is an underground leak, the movement of gas through the soil can filter the odorant.
Propane (LP) gas odor may differ in intensity at different levels. Since Propane (LP) gas is heavier than air, there may be more odor at lower levels.
Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously.
ATTENTION - CRITICAL POINTS TO
REMEMBER!
Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Fuel Gas Odor and Odor Fading sections above.
Even If you are not properly trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas.
If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system.
A periodic sniff test around the heater or at the heaterÊs joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!
Heater Elevation Adjustment
This heater is equipped with an elevation adjustment panel located at the exhaust end of the control box.
1. Do not adjust the heater combustion tube elevation while heater is running or hot. Adjustments to elevation should only be made after the heater has cooled to touch.
2. To adjust the heater combustion tube elevation, turn the adjustment screw knob counterclockwise and lift the combustion tube to desired position.
4
Force-Air Propane Construction HeaterOperating Instructions and OwnerÊs Manual
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage. If any is found, jnnfejbufmz notify the factory.
2. Follow all of the „Precautions‰.
3. Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinderÊs valve outlet and securely tighten with a wrench.
4. Connect the hose to the heater by rotating the hose fitting clockwise.
5. Securely tighten all gas connections.
6. Open the cylinderÊs gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME.
7. Connect power cord to well-grounded 115V, 60 Hz, 1± source of power.
8. When using an extension cord, make certain that it is a 3-wire (grounded) cord of proper wire size.
• The flame is essentially blue with perhaps some yellow tipping.
• There is no strong disagreeable odor, eye burning or other physical discomfort.
• There is no smoke or soot internal or external to the heater.
• There are no unplanned or unexplained shut downs of the heater.
The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT Match the color stripe on the hangtag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Do not use alternates. For this heater, the regulator must be set as shown in „specifications‰. If there is any uncertainty about the regulator setting, have it checked.
170QFAVT )XJUI!UIFSNPTUBU*
START
1. Slowly open the main valve at propane cylinder to prevent excess flow check valve from closing.
2. Set thermostat to full on. Heater will ignite automatically.
3. Adjust ball valve on control panel to desired burn rate.
4. Set thermostat to desired temperature. Heater will turn off and on automatically as the temperature varies in the heater area.
STOP
1. Securely close valve on the propane cylinder.
2. Continue to operate heater until all fuel in the hose has burned.
3. Turn the heater thermostat to „off‰. For extended shut down or in areas where the temperature is below 0°F, unplug the heater.
RESTART AFTER SAFETY SHUTDOWN
1. Securely close valve at propane cylinder. Unplug heater.
2. Wait 5 minutes.
3. Restart following „Start‰ procedure.
MAINTENANCE AND STORAGE
1. The heater should be inspected before each use, and at least annually by a qualified person.
2. Before each use, check the soft „O‰ ring seat at the bullnose of the POL fitting. If the „O‰ ring is cut, scuffed, or otherwise damaged, replace it with part number 6681.
3. Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.
4. When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the heater must be disconnected and the cylinder(s) removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.
A heater which is opu!working right must be repaired, but pomz by a trained, experienced service person.
In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.
Out-of-warrranty products will be repaired with a charge for parts and labor.
SERVICING
A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:
• The flame is contained within the heater.
Force-Air Propane Construction Heater Operating Instructions and OwnerÊs Manual
5
SIZE AND CAPACITY OF PROPANE
CYLINDERS
The charts below show the approximate size of the cylinder required for these heaters. To use the chart:
1. Select the lowest air temperature expected (at the bottom of the chart).
2. Move straight up to time of operation desired (left side of the chart).
3. Read the cylinder size required.
All heaters should have: full cylinders good air circulation no frost on cylinders
Fuel Cyclinder Capacity: 100#
WARNING: When using a thermostat controlled heater, its exit area should be protected from personnel and warnings posted of sudden startup.
Recommended Minimum Gauge
for Cord Extensions
Wire Gauge Chart A.W.G. Name Plate 120V Cord Length in Feet Amps. 25 50 100 150
5-6 18 16 14 12 6-8 18 16 12 10 8-12 18 14 12 10 10-12 16 14 10 8 12-14 16 12 10 8
WIRING DIAGRAM
HOW MUCH HEAT DO I REQUIRE?
For economy, it is important to match input to that required. But heat requirements often vary. For example, it usually takes a lot more heat to get things warm than it does to keep them that way. Likewise, outside air temperature usually changes during the day so you may need more heat at night than you do in the daytime. An approximation of the heat required can be found by using the chart below.
BTU’S PER HOUR REQUIRED
Cubic feet Temperature Rise Required (oF)* of space to be heated 20o 30o 40o 50
5,000 14,000 20,000 27,999 34,000
7,000 19,000 28,000 38,000 47,000
10,000 27,000 40,000 54,000 67,000
15,000 40,000 60,000 80,000 100,000
20,000 54,000 80,000 107,000 133,000
30.000 80,000 120,000 160,000 200,000
50,000 133,000 200,000 266,000 333,000
o
GAS
G
VALVE
CHASSIS GROUND
G
MOTOR
CHASSIS GROUND
LINE CORD
COLOR CODE B-BLACK L-BLUE
B
B
R
THERMOSTAT
B
G
B
W
CHASSIS GROUND
W
HIGH-LIMIT
Y
O-ORANGE R-RED W-WHITE
B
2
X
H
C
IT
W
S
Y
R
W
CHASSIS GROUND
LINE
VALVE
NEUT
GRD
FLAME CONTROL
G
SPARK PLUG
G
CHASSIS GROUND
G-GREEN
If any original wiring as supplied by the heater must be replaced, it must be replaced with type AWG 105° C wire or its equivalent except as indicated (*type SF2-200, **SGI 250° C).
170QFAVT - WIRING CHART
COLOR LENGTH FROM TO
White 7‰ Valve Terminal Block Black 6‰ On/Off Switch Terminal Block Red-(Hi-Temp) 16 1/2‰ High Limit Switch Valve Red-(Hi-Temp) 16 1/2‰ High Limit Switch Terminal Block Orange 11‰ Flame Control Spark Plug (Ignition) Green 7‰ Flame Control Ground (Harness) Red 7‰ Flame Control Terminal Block (Harness) White 6‰ Flame Control Terminal Block (Harness) Black 6‰ Flame Control Terminal Block (Harness)
6
Force-Air Propane Construction HeaterOperating Instructions and OwnerÊs Manual
Model #
OPERATING INSTRUCTIONS
MH170QFAVT
AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust,
or operate the heater.
WARNING:
USE ONLY MANUFACTURERÊS REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.
PARTS ORDERING INFORMATION:
PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or
direct from the factory.
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 800-251-0001 www.mrheater.com
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all communication.
LIMITED WARRANTY
Mr. Heater, Inc. warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from date of purchase. Mr. Heater, Inc. will repair or replace this product free of charge if it has been proven to be defective within the 1-year period and is returned at customer expense with proof of purchase to Mr. Heater, Inc. within the warranty period.
Mr. Heater, Inc. reserves the right to make changes at any time, without notice or obligation, in colors, specifications, accessories, materials, and models.
PRODUCT REGISTRATION: Thank you for your purchase. Please log in to http://www.egiregistration.com to register your product.
Mr. Heater GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001 Mr. Heater is a registered trademarks of Mr. Heater Group, Inc. © 2016, Mr. Heater Group, Inc. All rights reserved
ANSI Z83.7b/CSA 2.14b-2009
Loading...
+ 14 hidden pages