Mr. Heater Heatstar HSU45, MHU45, MHU75, Heatstar HSU75 Conversion Manual

FUEL CONVERSION MANUAL
MODEL
MHU45 MHU75
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
HEATSTAR
MODEL
LANGUAGES
ENGLISH Pages E1 — E8
SPANISH Pages S1 — S8
HSU45 HSU75
COMPACT UNIT HEATER
WARNING:
Improper installation, adjustment, alteration, service or maintenance
FRENCH Pages F1 — F8
can cause injury or property damage. Refer to this manual. For additional information consult a qualified installer, service agency or the gas supplier.
— WHAT TO DO IF YOU SMELL GAS
Open Windows
DO NOT try to light any appliance.
DO NOT use electrical switches.
DO NOT use any telephone in your house. Immediately call your local gas supplier from a
neighbor’s telephone. Follow the gas supplier’s instructions.
Do not touch any electrical switch; do not use any phone in your building.
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
If you cannot reach your gas supplier, call the Fire Department.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
06/10 Rev. Cmh #60017Mr. Heater, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-916-3000
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX­IDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
WARNING:
The State of California requires the following warn-
ing: COMBUSTION BY-PRODUCTS PRODUCED WHEN
USING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UN­KNOWN CHEMICALS.
WARNING
THIS CONVERSION KIT SHALL BE INSTALLED BY
A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE QUALIFIED SERVICE AGENCY PERFORMING THIS WORK ASSUMES RESPONSIBILITY FOR THE PROPER CONVERSION OF THIS APPLIANCE WITH THIS KIT.
CONTENTS
Fuel Conversion Kits ...............................................................E-3
Fuel Conversion Instructions ...................................................E-4
Rating Tag Conversion ............................................................E-6
Warranty ................................................................................E-8
Compact Unit Heater Fuel Conversion Manual
E-2
Section 1 FUEL CONVERSION KITS
Fuel Conversion Kit Part Numbers
Model No. BTU/hr Natural-To-L.P. MHU/HSU-45 45,000 F260067
For Natural - to L.P. Gas Conversions
Gas Conversion Labels: Spring (Red) - w/Label and Cap P/N (see Table below)
Contents of Fuel Conversion Kits (Natural - to - L.P.)
Part Number Description Conversion Kit Part Numbers MHU/HSU-45 MHU/HSU-75
13575 Gas Conversion Label 1 1
60011-10 Rating Tag 1
6011-23 Rating Tag 1
02877 Spring (Red) - Gas Valve (Label Included) 1 1
60056 L.P. Ori¯ce (Stamped 046) 3 5
13576 Control Conversion Label 1 1
MHU/HSU-75 75,000 F260069
L.P.
REG
Fuel Conversion Kit Part Numbers
Model No. BTU/hr L.P.-To-Natural MHU/HSU-45 45,000 F260066
For L.P. - to - Natural Gas Conversions
Gas Conversion Labels: Spring (Orange) - w/Label and Cap P/N (see Table below)
MHU/HSU-75 75,000 F260071
N.G. REG
Contents of Fuel Conversion Kits (L.P - to - Natural)
Part Number Description Conversion Kit Part Numbers MHU/HSU-45 MHU/HSU-75
13575 Gas Conversion Label 1 1
60010-11 Rating Tag 1
60123-11 Rating Tag 1
02878 Spring, Kit for Valve 1
60049
13576 Control Conversion Label 1 1
3 5
E-3
Fuel Conversion ManualCompact Unit Heater
Section 2 FUEL CONVERSION INSTRUCTIONS
Figure 1
2
4 5
6
WARNING: Explosion Hazard
Turn off the gas supply to the heater before performing any service or maintenance.
Failure to follow these instructions will result in death, injury or property damage.
WARNING: Electrical Shock Hazard
Unplug the electrical cord from the outlet before performing any service maintenance.
Failure to follow these instructions will result in death, injury or property damage.
See Figure 1
The electrode and sensor are not adjustable. DO NOT change location or position as part of this conversion kit.
located under the adjustment screw. Remove the spring kit from the conversion kit, and compare the part number of the kit to the parts
you are converting, install the new spring with the adjustment screw about (5) full rotations in the clockwise direction. Place conversion label supplied with the spring kit on the valve near the adjustment screw cover.
Step 3.
After converting the valve, remove the gas supply line to the unit and remove the manifold by turning the four screws in a counter­clockwise direction. This will allow the valve and manifold to pull straight out from the burners.
Step 4.
Remove the three orifices from the manifold with a ½” open end wrench. Turn them counter-clockwise to remove. Take the new
number stamped on the side of the orifice matches the number for the kit you are using. If it does not, immediately contact Mr. Heater,
manifold, using caution not to cross thread.
Step 1.
Caution the gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.
Step 2.
Remove and discard cap from gas valve/regulator with a flat blade screw driver by turning the cap counter-clockwise. Remove the regulator adjustment screw in the same manner. Do not discard the screw after removing. Remove and discard the spring that is
Step 5.
Replace the manifold in the unit and reconnect incoming gas supply line. Check all connections for leaks with soapy water.
Step 6.
port. See Figure 2. Pressure gauges are not reliable and may give a false reading.
Compact Unit Heater Fuel Conversion Manual
E-4
Figure 2
See Figure 2
Step 7
Reconnect thermostat, connect in main power supply, and turn main gas supply on.
Step 8
Turn up thermostat to call for heat.
Step 9
When burner lights, set the manifold gas pressure by turning the adjustment screw that holds the regulator spring that was replaced in step 6, of the unit covers.
Decrease Pressure Increase Pressure Counter Clock Wise Clock Wise
The Natural Gas unit should be set to (4” W.C.) and the LP unit should be set to (10” W.C.). The manometer illustration (See Figure 2) shows each of the pressure readings.
Step 10
Turn down thermostat, disconnect main power, and turn main gas off to appliance.
6 5 4 3 2 1
4"
0 1 2 3 4 5 6
6 5 4 3 2 1
10"
0 1 2 3 4 5 6
N.G. L.P.
Step 11
Disconnect manometer from appliance and replace test plug on valve.
Step 12
Connect main power, turn main gas back on, and turn up thermostat to call for heat. When main burner lights check all connections thoroughly for gas leaks.
Allow the heater to operate for at least 5 minutes, then observe the main burner flame. A hard blue flame extending into the tube is normal. Slight yellow tipping is acceptable. There is no air adjustment on burner.
Step 13
To ensure the correct rate is obtained, the orifice size should be verified during and after installation. The orifice size for Natural Gas is (.074”) and for LP the size is (.046”). These sizes are stamped on the side of the orifice. There are three (3) orifices for the MHU/HSU-45 heaters and five (5) orifices for the MHU/HSU-75 heaters. The manifold pressure should be verified after installation so that a natural gas pressure of (4”WC) or an LP pressure of (10”WC) is obtained. Enerco Group Inc is confident that with proper orifices and correct manifold pressure, your MHU/HSU heater will be operating at its correct BTU rating.
E-5
Fuel Conversion ManualCompact Unit Heater
Section 3 RATING TAG CONVERSION
Figure 3
See Figure 3
Step 14
See Figure 3. Remove the data tag P/N 60011-10 or 60010-11 for their respective gases. Remove label and place over the existing portion of the tag. This label is pre-printed with all the correct information.
Step 15
information. Then place this tag below the updated rating tag on the converted unit.
Figure 4
INLET PRESSURES:
Natural Gas
MAX - 14"WC (3.49kPa) MIN - 5"WC (1.25 kPa)
Propane
MAX - 14" WC (3.49 kPa) MIN - 11"WC (2.74 kPa)
Figure 5
NATURAL GAS MANIFOLD PRESSURES - IN.WG. (KPA)
ALTITUDE FT. (M)
MHU45/75 HSU 45/75
0-2000 2000-4500 (0-610) (610-1370)
45/75 4.0 (0.99)* 3.6 (0.89)
*No adjustment required.
Figure 6
LP/PROPANE GAS MANIFOLD PRESSURES - IN.WG. (KPA)
ALTITUDE FT. (M)
MHU45/75 HSU 45/75
0-2000 2000-4500 (0-610) (610-1370)
45/75 10 (2.49)* 8.0 (1.99)
*No adjustment required.
Compact Unit Heater Fuel Conversion Manual
E-6
THIS PAGE INTENTIONALLY LEFT BLANK.
E-7
Fuel Conversion ManualCompact Unit Heater
FUEL CONVERSION MANUAL
MODEL
MHU45 MHU75
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
HEATSTAR
MODEL
HSU45 HSU75
WARNING:
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.
PARTS ORDERING INFORMATION:
PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or direct
from the factory
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 800-251-0001 • www.mrheater.com Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday. Please include the model number, date of purchase, and description of problem in all communication.
LIMITED WARRANTY The company warrants this product to be free from imperfections in material or workmanship, under normal and proper use in accordance with instructions of The Company, for a period of one year from the date of delivery to the buyer. The Company, at its option, will repair or replace products returned by the buyer to the factory, transportation prepaid within said one year period and found by the Company to have imperfections in material or workmanship.
If a part is damaged or missing, call our Technical Support Depa
Address any Warranty Claims to the Service Department, Mr. Heater, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135. Include your name, address and telephone number and include details concerning the claim. Also, supply us with the purchase date and the name and address of the dealer from whom you purchased our product.
The foregoing is the full extent of the responsibility of the Company. There are no other warranties, express or implied. Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability. In no event shall the Company be liable for delay caused by imperfections, for consequential damages, or for any charges of the expense of any nature incurred without its written consent. The cost of repair or replacement shall be the exclusive remedy for any breach of warranty. There is no warranty against infringement of the like and no implied warranty arising from course of dealing or usage of trade. This warranty will not apply to any product which has been repaired or altered outside of the factory in any respect which in our judgment affects its condition or operation.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from state to state.
rtment at 800-251-0001.
Mr. Heater, Inc. reserves the right to make changes at any time, without notice or obli­gation, in colors, specifications, accessories, materials and models.
ANSI Z83.8/CGA 2.6-2009
UNIT HEATER
CSA .10.96 U.S. (2ND ED.)
UNIT HEATER FOR RESIDENTIAL INSTALLATION
CATEGORY/CATEORIE I
Mr. Heater, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-916-3000 Mr. Heater is a registered trademarks of Mr. Heater, Inc. © 2009, Mr. Heater. All rights reserved
Compact Unit Heater Fuel Conversion Manual
E-8
Loading...