READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a sa
fe place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
HE
ATSTAR
M
HS50KT, HS75KT,
LEDO
HS
125KT, HS175KT
KEROSENE FO
RCED-AIR HEATER
WARNING:
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
— Service must be performed by a qualified service agency.
This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion
and ventilation air must be provided. Refer to page 3.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
UL-733, &CSA/CAN3-B140.9.3
04/04 Revision L1 #70276ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-881-5500
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN
RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX­IDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A SAFE DIS­TANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PAR­TICLES OR UNKNOWN CHEMICALS.
WARNING:
The State of California requires the following warning:
COMBUSTION BY-PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).
WARNING:
• DO NOT USE GASOLINE, NAPHTHA OR VOLATILE FUELS.
• STOP HEATER BEFORE ADDING FUELS.
• ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME
• DO NOT USE EXTERNAL FUEL SOURCE.
• DO NOT OPERATE HEATER WHERE FLAMMABLE LIQUIDS OR VAPORS MAY BE PRESENT.
• DO NOT START HEATER WHEN CHAMBER IS HOT
• DO NOT START HEATER WHEN EXCESS FUEL HAS ACCUMULATED IN THE CHAMBER.
• DO NOT PLACE COOKING UTENSILS ON TOP OF THE HEATER.
• PLUG ELECTRICAL CORD INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.
50K & 75KT WARNING:
Not suitable for use on wood floors or other combustible materials. When used the heater should rest on a suitable insulating material at least 1 inch thick and extending 3 feet or more beyond the heater in all directions.
CONTENTS
WARNINGS ................................................................................. 2
HEATER SPECIFICATIONS ............................................................ 3
OPERATING PRECAUTIONS ......................................................... 3
SAFETY PRECAUTIONS ................................................................ 3
OPERATING INSTRUCTIONS ........................................................ 4
MAINTENANCE, STORAGE AND SERVICE ................................... 5
WIRING DIAGRAM...................................................................... 6
PARTS LIST .................................................................................. 6
EXPLODED VIEW......................................................................... 7
WARRANTY ................................................................................ 8
INSTRUCTIONS FOR ORDERING PARTS ....................................... 8
Enerco Group, Inc. | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
2
SPECIFICATIONS
Type of Fuel: For use with Kerosene or #1 Fuel Oil ONLY on ALL models.
Model ...................................... 50K ............................................. 75KT .......................................125KT ....................................... 175KT
Burn Rate:................................ 50,000 Btu/hr (15 kW) ...............75,000 Btu/hr (22 kW) ......... 125,000 Btu/hr (37 kW) ........... 175,000 Btu/hr (51 kW)
Fuel Rate:................................. 0.37 gal/hr (1.4 L/hr) ................. 0.55 gal/hr (2.1 L/hr) ............. 0.96 gal./hr (3.5 L/hr) ............. 1.3 gal/hr (5.0 L/hr)
Electrical Input: ........................ 115V, 60Hz, 3.5a......................... 115V, 60Hz, 4a ....................... 115V, 60Hz, 5.5a ...................... 115V, 60Hz, 5.5a
Line Protection:........................ 10 amps ...................................... 10 amps ................................. 20 amps ................................... 20 amps
Min. Operating Voltage: .......... 110V ............................................110V ....................................... 110V ......................................... 110V
Pressure Setting: ...................... 3.5 psig (24 kPa) ........................ 4.2 psig (29 kPa) .................... 5.0 psig (34 kPa) ...................... 5.8 psig (40 kPa)
Max. Outlet Temperature:........ 1300oF (704oC) ............................1300oF (704oC) .......................1300oF (704oC) ......................... 1300oF (704oC)
Fuel Tank Capacity: .................. 4 gallons (15.1 L) ........................6 gallons (22.7 L) ................... 14 gallons (53 L) ...................... 14 gallons (53 L)
Ignition: ................................... Direct Spark, Continuous............ Direct Spark, Continuous ....... Direct Spark, Continuous ......... Direct Spark, Continuous
Spark Generator: ..................... Igniter 13 kV, 10ma .................... Igniter 13 kV, 10ma ................Igniter 13 kV, 10ma .................. Igniter 13 kV, 10ma
Primary Safety Control:............ Solid State Control...................... Solid State Control ................. Solid State Control ................... Solid State Control
Certification:
OPERATING PRECAUTIONS
This is a kerosene, direct-fired, forced air heater. It's intended use is primarily temporary heating of buildings under construction, alteration or repair.
Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. CO can build up in a heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation are:
headache
dizziness
burning eyes and nose
nausea
dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating instructions.
Forced Air means that a blower or fan pushes the air through the heater. Proper combustion depends upon this air flow; therefore, the heater must not be revised, modified or operated with parts removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved.
SAFETY PRECAUTIONS
1. Check the heater thoroughly for damage. DO NOT operate a damaged heater.
2. DO NOT modify the heater or operate a heater which has been modified from its original condition.
3. Use only Kerosene. Never use gasoline, naphtha, paint thinner, alcohol or other fuels of any kind.
4. For indoor use only. Not for use where exposed to weather.
5. Use in well ventilated areas, provide at least 2 sq. ft. (0.19 sq. m.) of opening near the floor and 2 sq. ft. (0.19 sq. m.)
near the ceiling directly to outdoors. Increase air openings as marked for each additional heater.
6. Always keep combustibles, like paper and wood at least 8 ft. (2.4 m) from the heater outlet and 3 ft. (1.0 m) from the top, sides and inlet. Locate 10 ft. (3.0 m) from canvas or plastic coverings and secure them to prevent flapping movement.
7. Caution: Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition. Do Not Touch. Keep Children, Clothing, and Combustibles away.
8. Install the heater such that it is not directly exposed to water spray, rain and / or water.
9. Never use in areas normally for habitation and /or where children may be present.
10. Operate only on a stable, level surface. (MH50K & MH75KT – See wood floor warning).
11. Do not use with duct work. Do not restrict inlet or exit.
12. Use only with electrical power specified. The electrical connection and grounding must comply with National Electrical Code – ANSI/NFPA 70 (USA) and CSA C22.1 Canadian Electrical Code, Part 1 (Canada).
13. Use only a properly grounded 3-prong receptacle or extension cord.
14. Do not move, handle, or service while hot or burning.
15. Use only in accordance with local, state (provincial) or National requirements, ordinances and codes.
OPERATING INSTRUCTIONS
UNPACKING
1. Remove all protective material which may have been applied to the heater for shipment.
2. Remove heater from carton.
3. Check the heater for possible shipping damage. If any damage is found immediately notify the dealer from whom you purchased the heater.
ASSEMBLY (For 125,000 and 175,000 BTU/hr models only)
Wheel and handles are found in the shipping carton along with mounting hardware. The wheels, axle and mounting hardware are in a package. Tools required are a 5/16" nutdriver, 3/8" open or adjustable wrench and standard pliers.
Enerco Group, Inc. | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
3
1. Assemble the wheels onto the wheel support frame as follows:
a. Install one of the cotter pins into the hole on one end of
axle.
b. Slide the large washer, then wheel onto the axle next to
the cotter pin.
c. Slide a small washer, spacer, small washer onto the axle
next to the wheel.
d. Slide the partially assembled axle through the wheel
support frame.
e. Slide the small washer, spacer, and small washer onto
the axle next to the wheel support.
f. Slide the wheel then large washer onto the axle and
hold in place with the remaining cotter pin.
g. Install the caps over the larger washers to finish the
wheel assembly.
2. Position the heater on the wheel support frame assembly with the exit end over the wheels.
3. Use eight screws and nuts to attach the handles to the top of the tank flange. The screws will go through the handles, tank flange and wheel support frame. Install the nuts and finger tight only until all nuts are installed.
4. Tighten all the nuts.
5. Attach cord caddies to handles using No. (14) & No. (5) screws and nuts.
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage. If any is found, immediately notify the factory.
2. Follow all of the "Precautions".
3. Fill the fuel tank with clean kerosene. In extremely cold weather, condensation may develop in the tank and it is recommended that a tablespoon of de-icer be added for each gallon (4 liters) of fuel in the tank. When filling the heater, use at least 2 gallons (8 liters) of fuel. Be sure heater is level and do not overfill. Use a funnel or can with a long fill spout.
IMPORTANT: Before filling fuel tank the first time or after extended storage periods, drain the fuel tank of any moisture or condensation.
4. Locate heater at a safe distance from combustible materials. ModelS 50K & 75KT is not suitable for use on wood floors or other combustible materials. When used, the heater should rest on suitable insulating material at least 1 inch thick and extending 3 ft. or more beyond the heater in all directions.
START
1. 50K: Plug the heater into a grounded 115V, 60 Hz, 1 Ø outlet. 75KT, 125KT & 175KT: Turn thermostat to lowest setting, make sure “On/Off” switch is “Off”. Plug the heater into a grounded 115V, 60 Hz, 1 Ø outlet. Turn thermostat to highest setting. Start heater by push toggle switch to “On” position (light signifies switch is in “ON” position). Adjust thermostat to desired setting. Heater will cycle on/off as heat is required.
For all models: In cold weather, starting may be improved by holding a finger over the end of the pressure adjusting screw until the heater starts. This unit is equipped with a circuit breaker located near the power cord. If the unit does not start, check to see that the reset button is pressed in.
STOP
1. 50K: Unplug heater from power source.
75KT, 125KT & 175KT: Push “On/Off” switch to “Off” position. For extended shutdown, unplug heater from power source.
RESTART AFTER SAFETY SHUTDOWN (50K, 75KT, 125KT
& 175KT)
1. Wait 5 minutes.
2. Press reset button.
Handle assembly for 125KT 175KT only.
ITEM PART NO. DESCRIPTION QTY
1 M4365 Handle, Front 1 2 M4338 Handle, Rear 1 3 M4339 Wheel Support Frame 1 4 M6977 Machine Screw Blk (long) 8 5 M6037 Kep Nut Blk 12 6 M8746 Axle 1 7 M8752 Wheel 2 8 M8751 Cap 2 9 M8748 Spacer 2 10 M8747 Washer, Small 4 11 M8749 Washer, Large 2 12 M8750 Cotter Pin 2 13 M8754 Ext. Cord Caddy 2 14 M7336 Machine Screw Blk (Small) 4
Enerco Group, Inc. | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
4
MAINTENANCE AND STORAGE
WARNING. To prevent personal injury, unplug the heater from the wall outlet before servicing.
For maximum efficiency and trouble-free service, make the following periodic maintenance, cleaning and inspections.
DAILY SCHEDULE
1. GENERAL. Make general visual inspection of heater for loose
or damaged parts. Check nuts and bolts to insure against looseness caused by vibration or rough handling. Damaged parts should be repaired or replaced before using heater again. Check heater operation to be sure it is operating normally (See "Servicing" section for description of normal operation).
2. FILTERS. Dirty air or fuel filters will cause an imbalance in the
air-fuel mixture. The best indication that this condition exists is an increase in odors or difficulty getting your heater to ignite. This heater should never be operated without the filters in place. If required, clean filters as described under "500 Hours" and "Annual Schedules".
500 HOUR SCHEDULE
1. AIR INTAKE FILTER. Remove and wash the filter element with
a mild detergent, dry thoroughly and replace. Do not oil the filter element. If your heater is used where there is considerable dust or dirt, clean as often as necessary (approximately every 50 hrs.).
2. REMOVE DUST. Clean heater twice a season (more often
under dusty conditions). Remove accumulated dust from the transformer, burner, motor and fan blades with compressed air. Wipe area clean with a clean dry cloth. Inspect area to insure all foreign materials are removed, especially around the burner and combustion area.
3. CAD CELL. Clean the glass portion of the cad cell with a soft
dry cloth.
4. NOZZLE. Accumulation of dirt from fuel and carbon from the
compressor vanes will eventually fill up the passages in the nozzle, resulting in reduction of fuel and air flow. Pressure will gradually increase giving improper fuel-air mixture and excess odor and smoke. If this occurs, replace the fuel nozzle.
5. FUEL TANK. Clean twice a season (during frequently used
periods, clean twice a month). Drain and flush the fuel tank with clean fuel oil.
ANNUAL SCHEDULE
1. AIR OUTPUT FILTER. Remove the air output filter and tap the
contaminated side gently on a solid object to remove contaminates. Compressed air or liquids should not be used to clean this filter. Reinstall cleaned filter in filter body in the same position as it was when removed. If the filter appears extremely dirty, replace it with a new filter of the same type. When replacing the filter cover, be sure the gasket is firmly in place and the screws in the filter cover are tight to prevent air leaks.
2. FUEL FILTER. Remove the fuel filter from fuel line and direct
compressed air through the filter in the opposite direction of fuel flow. Safety glasses should be worn when using compressed air.
3. AIR AND FUEL LINES. If the air or fuel lines are removed during cleaning, be sure all connections are tight before operating unit.
4. AIR PRESSURE SETTING. The air pressure has been properly set at the factory. If the air pressure is out of adjustment, it will most likely be caused by dirty air filters, a partially plugged nozzle, an air leak in the system or improperly set pressure. If adjustment becomes necessary, first determine the proper pressure setting for your heater which is printed on the serial label located on the fuel tank. Remove the plug from the air filter cover and attach an accurate pressure gauge calibrated to a maximum reading of 15 PSI. Start the heater and note the pressure reading. If the pressure is low, slowly turn the pressure adjusting screw in (Clockwise) until the correct pressure is obtained. If the air pressure is high, turn the adjusting screw out (counterclockwise) until the pressure is correct. When correct pressure is reached, unplug the heater, remove the gauge and replace the plug.
STORAGE
Store the heater in a dry location free from fumes or dust.
At the end of each heating season, clean the heater as described in the MAINTENANCE section. Drain and flush the fuel tank with clean fuel. The manufacturer recommends completely filling the tank with fuel for extended storage to minimize condensation inside the tank.
SERVICING
A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:
* The flame is contained within the heater.
* The flame is essentially yellow.
* There is no strong disagreeable odor, eye burning or other
physical discomfort.
* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the
heater.
The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. Heater performance is effected by air pressure setting. If there is any uncertainty about the air pressure setting, have it checked.
A heater which is not working right must be repaired, but only by a trained, experienced service person.
In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.
Out-of-warranty products will be repaired with a charge for parts and labor.
Enerco Group, Inc. | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
5
Loading...
+ 11 hidden pages