Please read this manual carefully before installation and keep it for future reference.
For more details visit www.MrCool.com
Handling the Remote Control
Remote Controller Specifications
Timer Operation
Timer Operation
How to use the buttons
How to use the buttons
LCD Indicators
Operation of Buttons
Operation of Buttons
Operation of Buttons
CONTENTS
Information that is displayed when the remote is turned on.
NOTE:
•Use the remote controller within a distance of 26.25ft from the appliance, pointing it towards the
The device could comply with the local national regulations.
receiver. Reception is confirmed by a beep.
•In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
•In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
CAUTION
AUTO
AUTO
2
2
1
1
AUTO
COOL
COOL
COOL
DRY
DRY
DRY
HEAT
HEAT
HEAT
SWING
SWING
SWING
CLEAN
CLEAN
CLEAN
AIR
AIR
AIR
(1) This device may not cause harmful interference, and
•The air conditioner will not operate if curtains, doors or other materials block the signals from the
(2) this device must accept any interference received, including interference that may cause undesired
remote control to the indoor unit.
COMBINED TIMER
operation.
•Prevent any liquid from falling into the remote control. Do not expose the remote control to direct
(Setting both ON and OFF timers simultaneously)
sunlight orheat.
TIMER OFF TIMER ON
This equipment has been tested and found to comply with the limits for a Class B digital device,
•If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may
(On Stop Start operation)
pursuant topart 15 of the FCC Rules. These limits are designed to provide reasonable protection against
not function properly. Use curtains to prevent the sunlight from falling on the receiver.
This featureis useful when you want to stop the air conditioner after you go to bed, and start it again in
2
2
2
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
•If other electrical appliances react to the remote control, either move these appliances or consult your
the morning when you wake up or when you return home.
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
local dealer.
TIMER ON (Auto-on Operation)
EXAMPLE:
interference to radio communications. However, there is no guarantee that interference will not occur
•Do not drop the remote controller. Handle with care.
The TIMER ON feature is useful when you want the unit to turn on automatically before you return
3
3
3
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.
in a particular installation. If this equipment does cause harmful interference to radio or television
•Do not place heavy objects on the remote control, or step on it.
home. The air conditioner will automatically start operating at the set time.
1. Press the TIMER OFF button.
4
4
4
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
EXAMPLE:
2. Pressthe TIMER OFF button again to display 2.0H on the TIMER OFF display.
to correct the interference by one or more of the following measures:
Using the remote control mount (optional)
5
5
5
To start the air conditioner in 6 hours.
3. Press the TIMER ON button.
•Reorient or relocate the receiving antenna.
•The remote controller can be attached to a wall or pillar by using a remote controller holder (not
1. Press the TIMER ON button, the last setting of starting operation time and the signal "h" will show on the
6
6
6
4. Press the TIMER ON button again to display 10H on the TIMER ON display .
•Increase the separation between the equipment and receiver.
supplied, purchased separately).
display area.
5. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
7
7
7
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Before installing the remote controller, check that the air conditioner receives the signals properly.
2. Press the TIMER ON button to display "6.0h" on the TIMER ON display of the remote control.
indicator remains on and this function is activated.
•Consult the dealer or an experienced radio/TV technician for help.
•Install the remote control with two screws. For installing or removing the remote control, move it up
8
8
8
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON" indicator
•Changes or modifications not approved by the party responsible for compliance could void user’s
or down inthe holder.
remains onand this function is activated.
!
CAUTION
The effective operation time set by the remote controller for the timer function is
SET TEMPERATURE ( F)
Remote Control
limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0,
The following cases signify exhausted batteries. Replace old batteries with new ones.
Model:RG51F3/EU1 and
Model:RG51F3/EU1 and
•Receiving beep is not emitted when a signal is transmitted.
•Indicator fades away.
TIMER ON TIMER OFF
The remotecontrol is powed by two dry batteries (R03/LR03X2) housed in the back rear part and
(Off Start Stop operation)
protected by a cover.
TIMER OFF (Auto-off Operation)
This featureis useful when you want to start the air conditioner before you wake up and stop it after
(1) Removethe cover in the rear part of the remote control.
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed.
you leave the house.
(2) Removethe old batteries and insert the new batteries, placing the(+) and (-) ends correctly.
The air conditioner will stop automatically at the set time.
EXAMPLE:
(3) Install the cover back on.
EXAMPLE:
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.
To stop the air conditioner in 10 hours.
1. Press the TIMER ON button.NOTE: Whenthe batteries are removed, the remote control erases all programming. After inserting new
The design and specifications are subject to change without prior notice.
1. Press the TIMER OFF button, the last setting of stopping operation time and the signal "h" will show on the
2. Press the TIMER ON button again to display 2.0H on the TIMER ON display.
batteries, the remote control must be reprogrammed.
display area.
Consultwith the sales agency or manufacturer for details.
3. Press the TIMER OFF button.
2. Press the TIMER OFF button to display "10h" on the TIMER OFF display of the remote control.
4. Press the TIMER OFF button again to display
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER OFF" indicator
5.0H on the TIMER OFF display .
remains onand this function is activated.
5. Wait for 3 seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
indicator remains on and this function is activated.
Model:RG51F3/EU1 andRG51F/EU1(This model does not
RG51F/EU1(This model does not
RG51F/EU1(This model does nothave clean air button
have clean air button
have clean air button
AUTO
COOL
DRY
AUTO
HEAT
COOL
DRY
HEAT
2
CAUTION
1
•Do not mix old and new batteries or batteries of different types.
MODE
MODE
SWING
SWING
SET TEMPERATURE(F)
SET TEMPERATURE(F)
•Do not leave the batteries in the remote control if they are not going to be used for 2 or 3 months.
•Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special
treatment is necessary.
Remote control specifications
Operation of buttons
LCD Indicators
How to use the buttons
Timer operation
User Manual
Handling the remote control
TEMPTEMP
TEMP
TEMP
TEMP
ON/OFFON/OFF
ON/OFF
ON/OFF
ON/OFF
ECOECO
ECO
ECO
ECO
RESET LOCKRESET LOCK
AUTO
RESETLOCK
RESETLOCK
RESETLOCK
DISPLAY
LED
COOL
DISPLAY
LED
DRY
DISPLAY
DISPLAY
DISPLAY
LED
LED
LED
HEAT
Model
O
O
O
O
O
Rated Voltage
Signal Receiving
FAN
Range
HIGH
FAN
FAN
FAN
FAN
Environment
MED
HIGH
HIGH
HIGH
HIGH
LOW
MED
MED
MED
MED
LOW
LOW
LOW
LOW
AUTO
COOL
TIMER ON OFF
DRY
HEAT
Mode display
AUTO: COOL: DRY: HEAT: FAN:
FAN SPEED
Displayed when remote signal is sent.
FAN SPEED
FAN SPEED
FAN SPEED
FAN SPEED
TIMER ON
Displayed when remote control is ON.
TIMER ON
TIMER ON
TIMER ON
TIMER ON
TIMER OFF
SET TEMPERATURE(°F)
TIMER ONDisplayed when TIMER ON time is set.
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFFDisplayed when TIMER OFF time is set.
TURBOTURBO
TURBO
TURBO
TURBO
Show set temperature or room temperature,
22
33
DIY Series
RG51F/EU1, RG51F1/EU1, RG51F3/EU1
3.0V(Dry batteries R 03/LR03 2)
h
8m
62°F~ 86°F
h
TIMERON
1
1
1
9
9
9
10
10
10
11
11
11
FANHIGH
12
12
12
MEDLOW
13
13
13
or time under TIMER setting.
14
14
14
TEMP
Indicated all the current settings are locked.
TIMER ON
TIMER OFF
h
h
MODE
SWING
CLEAN AIR
TEMP
Fan speed indication
ON/OFF
HIGH- High speed
O
MED - Medium speed
ECO
FAN
LOW- Low speed
O
HIGH
No Display - Auto fan speed
MEDFAN
LOW
RESET LOCK
HIGHMED
Note:
LOW
All indicators shown in the figure are for the purpose
DISPLAY
LED
TIMER ONOFF
FAN SPEED
TIMEROFF
TURBO
of clear presentation. But during the actual operation
TEMPON/OFF
ON/OFF
ECO
ECO
RESET LOCK
LED
RESET LOCK
LED
only the relative functional signs are shown on the
display window.
FAN SPEED
TIMER ON
FAN SPEED
TIMER OFF
TIMER ON
Model:RG51F3/EU1
RG51F/EU1(This model does not
TIMER OFF
DISPLAY
TURBO
have clean air button)
DISPLAY
TURBO
2
3
1
4
2
DIY Series
Please keep this manual where the operator can easily find it.
Inside you will find helpful hints on how to use and maintain your
unit properly.
Dehumidifying operation
6
1
TIMER OFF Button
CLEAN AIR Button (applicable to RG51F3)
TEMP UP Button
12
Ensure the unit is plugged in and power is available.
Auto operation
Press this button to initiate the auto-off time
Disable/Active clean air function. When the clean
Push this button to increase the indoor temperThe OPERATION indicator on the display panel of
On
Ensure the unit is plugged in and power is
sequence. Each press will increase the auto-timed
air function is initiated, the Ionizer/Plasma Dust
ature setting in 1°F increments to 86°F.
the indoor unit starts flashing.
available. The OPERATION indicator on the display
setting in 30 minutes increments. When the setting
Collector (depending on models) is energized and
Set
2 hours later
1. Press the MODE button to select DRY mode.
2
TIMER ON OFF
13
73
8
14
9
4
10
5
11
after setting
panel of the indoor unit starts flashing.
time displays 10.0, each press will increase the
will help to remove pollen and impurities from the
TEMP DOWN Button
2. Press the UP/DOWN buttons to set the desired
1. Press the MODE button to select Auto.
auto-timed setting 60 minutes increments. To
air.
Push this button to decrease the indoor temper temperature. The temperature can be set within a
2. Press the UP/DOWN button to set the desired
cancel the autotimed program, simply adjust the
Swing Button (applicable to RG51F1)
ature setting in 1°F increments to 62°F.
range of 62°F~86°F in 1°F increments.
temperature. The temperature can be set within a
auto-off time to 0.0
Used to stop or start vertical louver movement and
NOTE:Temperature contol is not available in Fan
3. Press the ON/OFF button to start the air conditioner.range of 62°F~86°F in 1°F increments.
set the desired left/right air flow direction. The
mode.
NOTE:In the Dehumidifying mode, you can not switch
3. Press the ON/OFF button to start the air
LOCK Button
vertical louver changes 6 degree in angle for each
NOTE:Press and hold UP and DOWN buttons together
Set
the fan speed. It is automatically controlled.
conditioner.
Press this recessed button to lock all current
press.
for 3 seconds will toggle the temperature display
settings, and the remote control will not accept any
between the °C & °F scales.
Timer operation
NOTE:
operation except that of the LOCK. Use the LOCK
RESET Button
Press the TIMER ON button can set the auto-on
1. In the Auto mode, the air conditioner can logically
mode when you want to prevent settings from
Once the recessed RESET button is pressed, all of
MODE Button
time of the unit. Press the TIMER OFF button can
choose the mode of Cooling, Fan, and Heating by
being changed accidentally. Press the LOCK button
the current settings will be cancelled and the
Press this button to modify the air conditioner
set the auto-off time of the unit.
sensing the difference between the actual ambient
again to cancel the LOCK function. A lock symbol
control will return to the initial settings.
mode in a sequence of following:
To set the Auto-on time:
room temperature and the setting temperature on
will appear on the remote control display when the
AUTO COOL DRY HEAT FAN
1. Press the TIMER ON button. The remote control
the remote control.
lock function is activated.
LED Button
shows TIMER ON, the last Auto-on setting time and
2. In the Auto mode, you can not switch the fan speed.
Disable/Active indoor screen display. When
NOTE:Please do not select HEAT mode if the machine
the signal "H" will be shown on the LCD display
It has already been automatically controlled.
TURBO Button
pushing the button, the indoor screen display is
you purchased is cooling only type. Heat mode is not
area. Now it is ready to reset the Auto-on time to
3. If the Auto mode is not comfortable for you, the
Active/Disable Turbo function. Turbo function
cleared, press it again to light the display.
supported by the cooling only appliance.
START the operation.
desired mode can be selected manually.
enables the unit to reach the preset temperature
O
2. Push the TIMER ON button again to set desired
at cooling or heating operation in the shortest time
ON/OFF Button
SWING Button
Auto-on time. Each time you press the button, the
(if the indoor unit does not support this function,
Operation starts when this button is pressed and
Used to stop or start horizontal louver movement
time increases by half an hour between 0 and 10
there is no corresponding operation happened
stops when the button is pressed again.
or set the desired up/down air flow direction. The
Set
hours and by one hour between 10 and 24 hours.
Cooling/Heating/Fan operation
when pressing this button.)
louver changes 6 degree in angle for each press. If
On
3. After setting the TIMER ON, there will be a one
Ensure the unit is plugged in and power is available.
FAN SPEED Button
keep pushing more than 2 seconds, the louver will
second delay before the remote control transmits
Set 10 hours later
1. Press the MODE button to select COOL, HEAT
NOTE:
Used to select the fan speed in four steps:
swing up and down automatically.the signal to the air conditioner. Then, after
(cooling & heating models only) or FAN mode.
•Buttons design is based on typical model and might
Auto Low Med Highapproximately another 2 seconds, the signal "h" will
2. Press the UP/DOWN buttons to set the
be slightly different from the actual one you
ECO Button
disappear and the set temperature will re-appear
desired temperature. The temperature can be set
purchased the actual shape shall prevail.
TIMER ON Button
Used to enter the energy efficient mode. Under
on the LCD display window.
within a range of 62°F~86°F in 1°F increments.
•All the functions described are accomplished by the
Press this button to initiate the auto-on time
cooling mode, press this button, the remote
To set the Auto-off time:
3. Press the FAN button to select the fan speed in
unit. If the unit has no this feature, there is no
sequence. Each press will increase the auto-timed
control will adjust the temperature automatically
1. Press the TIMER OFF button. The remote control
four steps- Auto, Low, Med, or High.
corresponding operation happened when press the
setting in 30 minutes increments. When the setting
to 75°F, fan speed of Auto to save energy (but only
shows TIMER OFF, the last Auto-off setting time and
4. Press the ON/OFF button to start the air
relative button on the remote controller.
time displays 10.0, each press will increase the
if the set temperature is less than 75°F). If the set
the signal "H" will be shown on the LCD display area.
conditioner.
•When there are differences between the Remote
autotimed setting 60 minutes increments. To
temperature is between 75°F and 86°F, press the
Now it is ready to resetthe Auto-off time to stop the
Control Manual and User Manual on function
cancel the auto-timed program, simply adjust the
ECO button, the fan speed will change to Auto, the
operation.
NOTE:
description, use the description from the User Manual.
auto-on time to 0.0.
set temperature will remain unchanged.
2. Push the TIMER OFF button again to set desired
In the FAN mode, the setting temperature is not
NOTE:
Auto-off time. Each time you press the button, the
displayed in the remote control and you are not able
•Pressing the TURBO and SLEEP button, modifying the
time increases by half an hour between 0 and 10
to control the room temperature either. In this case,
mode or adjusting the set temperature to less than
hours and by one hour between 10 and 24 hours.
only step 1, 3 and 4 may be performed.
75°F will stop ECO operation.
3. After setting the TIMER OFF, there will be a one
•Under ECO operation, the set temperature should be
second delay before the remote control transmits
75°F or more. it may result in insufficient cooling. If
the signal to the air conditioner. Then, after
you feel uncomfortable, just press the ECO button
approximately another 2 seconds, the signal "H" will
again to stop it.
Stop
FAN
HIGH
MED
LOW
O
AUTOCOOLDRYHEAT
2 hours laterafter setting
SWING
SWING
MODE
disappear and the set temperature will re-appear
on the LCD display window.
12
11
10
9
8
7
6
5
4
3
2
1
Start
10 hours later
after setting
Start
6 hours later
SET TEMPERATURE(°F)
Start
TEMP
Stop
ON/OFF
Stop
5 hours laterafter setting
ECO
RESET LOCK
DISPLAY
LED
Model : RG51F1/EU1
2
3
6
7
9
11
FANHIGHMEDLOW
FAN SPEED
TIMER ON
TIMER OFF
TURBO
Please read this manual carefully before installation and keep it for future reference.
For more details visit www.MrCool.com
Handling the Remote Control
Remote Controller Specifications
Timer Operation
Timer Operation
How to use the buttons
How to use the buttons
LCD Indicators
Operation of Buttons
Operation of Buttons
Operation of Buttons
CONTENTS
Information that is displayed when the remote is turned on.
NOTE:
•Use the remote controller within a distance of 26.25ft from the appliance, pointing it towards the
The device could comply with the local national regulations.
receiver. Reception is confirmed by a beep.
•In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
•In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
CAUTION
AUTO
AUTO
2
2
1
1
AUTO
COOL
COOL
COOL
DRY
DRY
DRY
HEAT
HEAT
HEAT
SWING
SWING
SWING
CLEAN
CLEAN
CLEAN
AIR
AIR
AIR
(1) This device may not cause harmful interference, and
•The air conditioner will not operate if curtains, doors or other materials block the signals from the
(2) this device must accept any interference received, including interference that may cause undesired
remote control to the indoor unit.
COMBINED TIMER
operation.
•Prevent any liquid from falling into the remote control. Do not expose the remote control to direct
(Setting both ON and OFF timers simultaneously)
sunlight orheat.
TIMER OFF TIMER ON
This equipment has been tested and found to comply with the limits for a Class B digital device,
•If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may
(On Stop Start operation)
pursuant topart 15 of the FCC Rules. These limits are designed to provide reasonable protection against
not function properly. Use curtains to prevent the sunlight from falling on the receiver.
This featureis useful when you want to stop the air conditioner after you go to bed, and start it again in
2
2
2
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
•If other electrical appliances react to the remote control, either move these appliances or consult your
the morning when you wake up or when you return home.
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
local dealer.
TIMER ON (Auto-on Operation)
EXAMPLE:
interference to radio communications. However, there is no guarantee that interference will not occur
•Do not drop the remote controller. Handle with care.
The TIMER ON feature is useful when you want the unit to turn on automatically before you return
3
3
3
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.
in a particular installation. If this equipment does cause harmful interference to radio or television
•Do not place heavy objects on the remote control, or step on it.
home. The air conditioner will automatically start operating at the set time.
1. Press the TIMER OFF button.
4
4
4
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
EXAMPLE:
2. Pressthe TIMER OFF button again to display 2.0H on the TIMER OFF display.
to correct the interference by one or more of the following measures:
Using the remote control mount (optional)
5
5
5
To start the air conditioner in 6 hours.
3. Press the TIMER ON button.
•Reorient or relocate the receiving antenna.
•The remote controller can be attached to a wall or pillar by using a remote controller holder (not
1. Press the TIMER ON button, the last setting of starting operation time and the signal "h" will show on the
6
6
6
4. Press the TIMER ON button again to display 10H on the TIMER ON display .
•Increase the separation between the equipment and receiver.
supplied, purchased separately).
display area.
5. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
7
7
7
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Before installing the remote controller, check that the air conditioner receives the signals properly.
2. Press the TIMER ON button to display "6.0h" on the TIMER ON display of the remote control.
indicator remains on and this function is activated.
•Consult the dealer or an experienced radio/TV technician for help.
•Install the remote control with two screws. For installing or removing the remote control, move it up
8
8
8
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON" indicator
•Changes or modifications not approved by the party responsible for compliance could void user’s
or down inthe holder.
remains onand this function is activated.
!
CAUTION
The effective operation time set by the remote controller for the timer function is
SET TEMPERATURE ( F)
Remote Control
limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0,
The following cases signify exhausted batteries. Replace old batteries with new ones.
Model:RG51F3/EU1 and
Model:RG51F3/EU1 and
•Receiving beep is not emitted when a signal is transmitted.
•Indicator fades away.
TIMER ON TIMER OFF
The remotecontrol is powed by two dry batteries (R03/LR03X2) housed in the back rear part and
(Off Start Stop operation)
protected by a cover.
TIMER OFF (Auto-off Operation)
This featureis useful when you want to start the air conditioner before you wake up and stop it after
(1) Removethe cover in the rear part of the remote control.
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed.
you leave the house.
(2) Removethe old batteries and insert the new batteries, placing the(+) and (-) ends correctly.
The air conditioner will stop automatically at the set time.
EXAMPLE:
(3) Install the cover back on.
EXAMPLE:
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.
To stop the air conditioner in 10 hours.
1. Press the TIMER ON button.NOTE: Whenthe batteries are removed, the remote control erases all programming. After inserting new
The design and specifications are subject to change without prior notice.
1. Press the TIMER OFF button, the last setting of stopping operation time and the signal "h" will show on the
2. Press the TIMER ON button again to display 2.0H on the TIMER ON display.
batteries, the remote control must be reprogrammed.
display area.
Consultwith the sales agency or manufacturer for details.
3. Press the TIMER OFF button.
2. Press the TIMER OFF button to display "10h" on the TIMER OFF display of the remote control.
4. Press the TIMER OFF button again to display
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER OFF" indicator
5.0H on the TIMER OFF display .
remains onand this function is activated.
5. Wait for 3 seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
indicator remains on and this function is activated.
Model:RG51F3/EU1 andRG51F/EU1(This model does not
RG51F/EU1(This model does not
RG51F/EU1(This model does nothave clean air button
have clean air button
have clean air button
AUTO
COOL
DRY
AUTO
HEAT
COOL
DRY
HEAT
2
CAUTION
1
•Do not mix old and new batteries or batteries of different types.
MODE
MODE
SWING
SWING
SET TEMPERATURE(F)
SET TEMPERATURE(F)
•Do not leave the batteries in the remote control if they are not going to be used for 2 or 3 months.
•Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special
treatment is necessary.
Remote control specifications
Operation of buttons
LCD Indicators
How to use the buttons
Timer operation
User Manual
Handling the remote control
TEMPTEMP
TEMP
TEMP
TEMP
ON/OFFON/OFF
ON/OFF
ON/OFF
ON/OFF
ECOECO
ECO
ECO
ECO
RESET LOCKRESET LOCK
AUTO
RESETLOCK
RESETLOCK
RESETLOCK
DISPLAY
LED
COOL
DISPLAY
LED
DRY
DISPLAY
DISPLAY
DISPLAY
LED
LED
LED
HEAT
Model
O
O
O
O
O
Rated Voltage
Signal Receiving
FAN
Range
HIGH
FAN
FAN
FAN
FAN
Environment
MED
HIGH
HIGH
HIGH
HIGH
LOW
MED
MED
MED
MED
LOW
LOW
LOW
LOW
AUTO
COOL
TIMER ON OFF
DRY
HEAT
Mode display
AUTO: COOL: DRY: HEAT: FAN:
FAN SPEED
Displayed when remote signal is sent.
FAN SPEED
FAN SPEED
FAN SPEED
FAN SPEED
TIMER ON
Displayed when remote control is ON.
TIMER ON
TIMER ON
TIMER ON
TIMER ON
TIMER OFF
SET TEMPERATURE(°F)
TIMER ONDisplayed when TIMER ON time is set.
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFFDisplayed when TIMER OFF time is set.
TURBOTURBO
TURBO
TURBO
TURBO
Show set temperature or room temperature,
22
33
DIY Series
RG51F/EU1, RG51F1/EU1, RG51F3/EU1
3.0V(Dry batteries R 03/LR03 2)
h
8m
62°F~ 86°F
h
TIMERON
1
1
1
9
9
9
10
10
10
11
11
11
FANHIGH
12
12
12
MEDLOW
13
13
13
or time under TIMER setting.
14
14
14
TEMP
Indicated all the current settings are locked.
TIMER ON
TIMER OFF
h
h
MODE
SWING
CLEAN AIR
TEMP
Fan speed indication
ON/OFF
HIGH- High speed
O
MED - Medium speed
ECO
FAN
LOW- Low speed
O
HIGH
No Display - Auto fan speed
MEDFAN
LOW
RESET LOCK
HIGHMED
Note:
LOW
All indicators shown in the figure are for the purpose
DISPLAY
LED
TIMER ONOFF
FAN SPEED
TIMEROFF
TURBO
of clear presentation. But during the actual operation
TEMPON/OFF
ON/OFF
ECO
ECO
RESET LOCK
LED
RESET LOCK
LED
only the relative functional signs are shown on the
display window.
FAN SPEED
TIMER ON
FAN SPEED
TIMER OFF
TIMER ON
Model:RG51F3/EU1
RG51F/EU1(This model does not
TIMER OFF
DISPLAY
TURBO
have clean air button)
DISPLAY
TURBO
2
3
1
4
2
DIY Series
Please keep this manual where the operator can easily find it.
Inside you will find helpful hints on how to use and maintain your
unit properly.
Dehumidifying operation
6
1
TIMER OFF Button
CLEAN AIR Button (applicable to RG51F3)
TEMP UP Button
12
Ensure the unit is plugged in and power is available.
Auto operation
Press this button to initiate the auto-off time
Disable/Active clean air function. When the clean
Push this button to increase the indoor temperThe OPERATION indicator on the display panel of
On
Ensure the unit is plugged in and power is
sequence. Each press will increase the auto-timed
air function is initiated, the Ionizer/Plasma Dust
ature setting in 1°F increments to 86°F.
the indoor unit starts flashing.
available. The OPERATION indicator on the display
setting in 30 minutes increments. When the setting
Collector (depending on models) is energized and
Set
2 hours later
1. Press the MODE button to select DRY mode.
2
TIMER ON OFF
13
73
8
14
9
4
10
5
11
after setting
panel of the indoor unit starts flashing.
time displays 10.0, each press will increase the
will help to remove pollen and impurities from the
TEMP DOWN Button
2. Press the UP/DOWN buttons to set the desired
1. Press the MODE button to select Auto.
auto-timed setting 60 minutes increments. To
air.
Push this button to decrease the indoor temper temperature. The temperature can be set within a
2. Press the UP/DOWN button to set the desired
cancel the autotimed program, simply adjust the
Swing Button (applicable to RG51F1)
ature setting in 1°F increments to 62°F.
range of 62°F~86°F in 1°F increments.
temperature. The temperature can be set within a
auto-off time to 0.0
Used to stop or start vertical louver movement and
NOTE:Temperature contol is not available in Fan
3. Press the ON/OFF button to start the air conditioner.range of 62°F~86°F in 1°F increments.
set the desired left/right air flow direction. The
mode.
NOTE:In the Dehumidifying mode, you can not switch
3. Press the ON/OFF button to start the air
LOCK Button
vertical louver changes 6 degree in angle for each
NOTE:Press and hold UP and DOWN buttons together
Set
the fan speed. It is automatically controlled.
conditioner.
Press this recessed button to lock all current
press.
for 3 seconds will toggle the temperature display
settings, and the remote control will not accept any
between the °C & °F scales.
Timer operation
NOTE:
operation except that of the LOCK. Use the LOCK
RESET Button
Press the TIMER ON button can set the auto-on
1. In the Auto mode, the air conditioner can logically
mode when you want to prevent settings from
Once the recessed RESET button is pressed, all of
MODE Button
time of the unit. Press the TIMER OFF button can
choose the mode of Cooling, Fan, and Heating by
being changed accidentally. Press the LOCK button
the current settings will be cancelled and the
Press this button to modify the air conditioner
set the auto-off time of the unit.
sensing the difference between the actual ambient
again to cancel the LOCK function. A lock symbol
control will return to the initial settings.
mode in a sequence of following:
To set the Auto-on time:
room temperature and the setting temperature on
will appear on the remote control display when the
AUTO COOL DRY HEAT FAN
1. Press the TIMER ON button. The remote control
the remote control.
lock function is activated.
LED Button
shows TIMER ON, the last Auto-on setting time and
2. In the Auto mode, you can not switch the fan speed.
Disable/Active indoor screen display. When
NOTE:Please do not select HEAT mode if the machine
the signal "H" will be shown on the LCD display
It has already been automatically controlled.
TURBO Button
pushing the button, the indoor screen display is
you purchased is cooling only type. Heat mode is not
area. Now it is ready to reset the Auto-on time to
3. If the Auto mode is not comfortable for you, the
Active/Disable Turbo function. Turbo function
cleared, press it again to light the display.
supported by the cooling only appliance.
START the operation.
desired mode can be selected manually.
enables the unit to reach the preset temperature
O
2. Push the TIMER ON button again to set desired
at cooling or heating operation in the shortest time
ON/OFF Button
SWING Button
Auto-on time. Each time you press the button, the
(if the indoor unit does not support this function,
Operation starts when this button is pressed and
Used to stop or start horizontal louver movement
time increases by half an hour between 0 and 10
there is no corresponding operation happened
stops when the button is pressed again.
or set the desired up/down air flow direction. The
Set
hours and by one hour between 10 and 24 hours.
Cooling/Heating/Fan operation
when pressing this button.)
louver changes 6 degree in angle for each press. If
On
3. After setting the TIMER ON, there will be a one
Ensure the unit is plugged in and power is available.
FAN SPEED Button
keep pushing more than 2 seconds, the louver will
second delay before the remote control transmits
Set 10 hours later
1. Press the MODE button to select COOL, HEAT
NOTE:
Used to select the fan speed in four steps:
swing up and down automatically.the signal to the air conditioner. Then, after
(cooling & heating models only) or FAN mode.
•Buttons design is based on typical model and might
Auto Low Med Highapproximately another 2 seconds, the signal "h" will
2. Press the UP/DOWN buttons to set the
be slightly different from the actual one you
ECO Button
disappear and the set temperature will re-appear
desired temperature. The temperature can be set
purchased the actual shape shall prevail.
TIMER ON Button
Used to enter the energy efficient mode. Under
on the LCD display window.
within a range of 62°F~86°F in 1°F increments.
•All the functions described are accomplished by the
Press this button to initiate the auto-on time
cooling mode, press this button, the remote
To set the Auto-off time:
3. Press the FAN button to select the fan speed in
unit. If the unit has no this feature, there is no
sequence. Each press will increase the auto-timed
control will adjust the temperature automatically
1. Press the TIMER OFF button. The remote control
four steps- Auto, Low, Med, or High.
corresponding operation happened when press the
setting in 30 minutes increments. When the setting
to 75°F, fan speed of Auto to save energy (but only
shows TIMER OFF, the last Auto-off setting time and
4. Press the ON/OFF button to start the air
relative button on the remote controller.
time displays 10.0, each press will increase the
if the set temperature is less than 75°F). If the set
the signal "H" will be shown on the LCD display area.
conditioner.
•When there are differences between the Remote
autotimed setting 60 minutes increments. To
temperature is between 75°F and 86°F, press the
Now it is ready to resetthe Auto-off time to stop the
Control Manual and User Manual on function
cancel the auto-timed program, simply adjust the
ECO button, the fan speed will change to Auto, the
operation.
NOTE:
description, use the description from the User Manual.
auto-on time to 0.0.
set temperature will remain unchanged.
2. Push the TIMER OFF button again to set desired
In the FAN mode, the setting temperature is not
NOTE:
Auto-off time. Each time you press the button, the
displayed in the remote control and you are not able
•Pressing the TURBO and SLEEP button, modifying the
time increases by half an hour between 0 and 10
to control the room temperature either. In this case,
mode or adjusting the set temperature to less than
hours and by one hour between 10 and 24 hours.
only step 1, 3 and 4 may be performed.
75°F will stop ECO operation.
3. After setting the TIMER OFF, there will be a one
•Under ECO operation, the set temperature should be
second delay before the remote control transmits
75°F or more. it may result in insufficient cooling. If
the signal to the air conditioner. Then, after
you feel uncomfortable, just press the ECO button
approximately another 2 seconds, the signal "H" will
again to stop it.
Stop
FAN
HIGH
MED
LOW
O
AUTOCOOLDRYHEAT
2 hours laterafter setting
SWING
SWING
MODE
disappear and the set temperature will re-appear
on the LCD display window.
12
11
10
9
8
7
6
5
4
3
2
1
Start
10 hours later
after setting
Start
6 hours later
SET TEMPERATURE(°F)
Start
TEMP
Stop
ON/OFF
Stop
5 hours laterafter setting
ECO
RESET LOCK
DISPLAY
LED
Model : RG51F1/EU1
2
3
6
7
9
11
FANHIGHMEDLOW
FAN SPEED
TIMER ON
TIMER OFF
TURBO
Please read this manual carefully before installation and keep it for future reference.
For more details visit www.MrCool.com
Handling the Remote Control
Remote Controller Specifications
Timer Operation
Timer Operation
How to use the buttons
How to use the buttons
LCD Indicators
Operation of Buttons
Operation of Buttons
Operation of Buttons
CONTENTS
Information that is displayed when the remote is turned on.
NOTE:
•Use the remote controller within a distance of 26.25ft from the appliance, pointing it towards the
The device could comply with the local national regulations.
receiver. Reception is confirmed by a beep.
•In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
•In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
CAUTION
AUTO
AUTO
2
2
1
1
AUTO
COOL
COOL
COOL
DRY
DRY
DRY
HEAT
HEAT
HEAT
SWING
SWING
SWING
CLEAN
CLEAN
CLEAN
AIR
AIR
AIR
(1) This device may not cause harmful interference, and
•The air conditioner will not operate if curtains, doors or other materials block the signals from the
(2) this device must accept any interference received, including interference that may cause undesired
remote control to the indoor unit.
COMBINED TIMER
operation.
•Prevent any liquid from falling into the remote control. Do not expose the remote control to direct
(Setting both ON and OFF timers simultaneously)
sunlight orheat.
TIMER OFF TIMER ON
This equipment has been tested and found to comply with the limits for a Class B digital device,
•If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may
(On Stop Start operation)
pursuant topart 15 of the FCC Rules. These limits are designed to provide reasonable protection against
not function properly. Use curtains to prevent the sunlight from falling on the receiver.
This featureis useful when you want to stop the air conditioner after you go to bed, and start it again in
2
2
2
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
•If other electrical appliances react to the remote control, either move these appliances or consult your
the morning when you wake up or when you return home.
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
local dealer.
TIMER ON (Auto-on Operation)
EXAMPLE:
interference to radio communications. However, there is no guarantee that interference will not occur
•Do not drop the remote controller. Handle with care.
The TIMER ON feature is useful when you want the unit to turn on automatically before you return
3
3
3
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.
in a particular installation. If this equipment does cause harmful interference to radio or television
•Do not place heavy objects on the remote control, or step on it.
home. The air conditioner will automatically start operating at the set time.
1. Press the TIMER OFF button.
4
4
4
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
EXAMPLE:
2. Pressthe TIMER OFF button again to display 2.0H on the TIMER OFF display.
to correct the interference by one or more of the following measures:
Using the remote control mount (optional)
5
5
5
To start the air conditioner in 6 hours.
3. Press the TIMER ON button.
•Reorient or relocate the receiving antenna.
•The remote controller can be attached to a wall or pillar by using a remote controller holder (not
1. Press the TIMER ON button, the last setting of starting operation time and the signal "h" will show on the
6
6
6
4. Press the TIMER ON button again to display 10H on the TIMER ON display .
•Increase the separation between the equipment and receiver.
supplied, purchased separately).
display area.
5. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
7
7
7
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Before installing the remote controller, check that the air conditioner receives the signals properly.
2. Press the TIMER ON button to display "6.0h" on the TIMER ON display of the remote control.
indicator remains on and this function is activated.
•Consult the dealer or an experienced radio/TV technician for help.
•Install the remote control with two screws. For installing or removing the remote control, move it up
8
8
8
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON" indicator
•Changes or modifications not approved by the party responsible for compliance could void user’s
or down inthe holder.
remains onand this function is activated.
!
CAUTION
The effective operation time set by the remote controller for the timer function is
SET TEMPERATURE ( F)
Remote Control
limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0,
The following cases signify exhausted batteries. Replace old batteries with new ones.
Model:RG51F3/EU1 and
Model:RG51F3/EU1 and
•Receiving beep is not emitted when a signal is transmitted.
•Indicator fades away.
TIMER ON TIMER OFF
The remotecontrol is powed by two dry batteries (R03/LR03X2) housed in the back rear part and
(Off Start Stop operation)
protected by a cover.
TIMER OFF (Auto-off Operation)
This featureis useful when you want to start the air conditioner before you wake up and stop it after
(1) Removethe cover in the rear part of the remote control.
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed.
you leave the house.
(2) Removethe old batteries and insert the new batteries, placing the(+) and (-) ends correctly.
The air conditioner will stop automatically at the set time.
EXAMPLE:
(3) Install the cover back on.
EXAMPLE:
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.
To stop the air conditioner in 10 hours.
1. Press the TIMER ON button.NOTE: Whenthe batteries are removed, the remote control erases all programming. After inserting new
The design and specifications are subject to change without prior notice.
1. Press the TIMER OFF button, the last setting of stopping operation time and the signal "h" will show on the
2. Press the TIMER ON button again to display 2.0H on the TIMER ON display.
batteries, the remote control must be reprogrammed.
display area.
Consultwith the sales agency or manufacturer for details.
3. Press the TIMER OFF button.
2. Press the TIMER OFF button to display "10h" on the TIMER OFF display of the remote control.
4. Press the TIMER OFF button again to display
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER OFF" indicator
5.0H on the TIMER OFF display .
remains onand this function is activated.
5. Wait for 3 seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
indicator remains on and this function is activated.
Model:RG51F3/EU1 andRG51F/EU1(This model does not
RG51F/EU1(This model does not
RG51F/EU1(This model does nothave clean air button
have clean air button
have clean air button
AUTO
COOL
DRY
AUTO
HEAT
COOL
DRY
HEAT
2
CAUTION
1
•Do not mix old and new batteries or batteries of different types.
MODE
MODE
SWING
SWING
SET TEMPERATURE(F)
SET TEMPERATURE(F)
•Do not leave the batteries in the remote control if they are not going to be used for 2 or 3 months.
•Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special
treatment is necessary.
Remote control specifications
Operation of buttons
LCD Indicators
How to use the buttons
Timer operation
User Manual
Handling the remote control
TEMPTEMP
TEMP
TEMP
TEMP
ON/OFFON/OFF
ON/OFF
ON/OFF
ON/OFF
ECOECO
ECO
ECO
ECO
RESET LOCKRESET LOCK
AUTO
RESETLOCK
RESETLOCK
RESETLOCK
DISPLAY
LED
COOL
DISPLAY
LED
DRY
DISPLAY
DISPLAY
DISPLAY
LED
LED
LED
HEAT
Model
O
O
O
O
O
Rated Voltage
Signal Receiving
FAN
Range
HIGH
FAN
FAN
FAN
FAN
Environment
MED
HIGH
HIGH
HIGH
HIGH
LOW
MED
MED
MED
MED
LOW
LOW
LOW
LOW
AUTO
COOL
TIMER ON OFF
DRY
HEAT
Mode display
AUTO: COOL: DRY: HEAT: FAN:
FAN SPEED
Displayed when remote signal is sent.
FAN SPEED
FAN SPEED
FAN SPEED
FAN SPEED
TIMER ON
Displayed when remote control is ON.
TIMER ON
TIMER ON
TIMER ON
TIMER ON
TIMER OFF
SET TEMPERATURE(°F)
TIMER ONDisplayed when TIMER ON time is set.
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFFDisplayed when TIMER OFF time is set.
TURBOTURBO
TURBO
TURBO
TURBO
Show set temperature or room temperature,
22
33
DIY Series
RG51F/EU1, RG51F1/EU1, RG51F3/EU1
3.0V(Dry batteries R 03/LR03 3)
h
8m
62°F~ 86°F
h
TIMERON
1
1
1
9
9
9
10
10
10
11
11
11
FANHIGH
12
12
12
MEDLOW
13
13
13
or time under TIMER setting.
14
14
14
TEMP
Indicated all the current settings are locked.
TIMER ON
TIMER OFF
h
h
MODE
SWING
CLEAN AIR
TEMP
Fan speed indication
ON/OFF
HIGH- High speed
O
MED - Medium speed
ECO
FAN
LOW- Low speed
O
HIGH
No Display - Auto fan speed
MEDFAN
LOW
RESET LOCK
HIGHMED
Note:
LOW
All indicators shown in the figure are for the purpose
DISPLAY
LED
TIMER ONOFF
FAN SPEED
TIMEROFF
TURBO
of clear presentation. But during the actual operation
TEMPON/OFF
ON/OFF
ECO
ECO
RESET LOCK
LED
RESET LOCK
LED
only the relative functional signs are shown on the
display window.
FAN SPEED
TIMER ON
FAN SPEED
TIMER OFF
TIMER ON
Model:RG51F3/EU1
RG51F/EU1(This model does not
TIMER OFF
DISPLAY
TURBO
have clean air button)
DISPLAY
TURBO
2
3
1
4
2
DIY Series
Please keep this manual where the operator can easily find it.
Inside you will find helpful hints on how to use and maintain your
unit properly.
Dehumidifying operation
6
1
TIMER OFF Button
CLEAN AIR Button (applicable to RG51F3)
TEMP UP Button
12
Ensure the unit is plugged in and power is available.
Auto operation
Press this button to initiate the auto-off time
Disable/Active clean air function. When the clean
Push this button to increase the indoor temperThe OPERATION indicator on the display panel of
On
Ensure the unit is plugged in and power is
sequence. Each press will increase the auto-timed
air function is initiated, the Ionizer/Plasma Dust
ature setting in 1°F increments to 86°F.
the indoor unit starts flashing.
available. The OPERATION indicator on the display
setting in 30 minutes increments. When the setting
Collector (depending on models) is energized and
Set
2 hours later
1. Press the MODE button to select DRY mode.
2
TIMER ON OFF
13
73
8
14
9
4
10
5
11
after setting
panel of the indoor unit starts flashing.
time displays 10.0, each press will increase the
will help to remove pollen and impurities from the
TEMP DOWN Button
2. Press the UP/DOWN buttons to set the desired
1. Press the MODE button to select Auto.
auto-timed setting 60 minutes increments. To
air.
Push this button to decrease the indoor temper temperature. The temperature can be set within a
2. Press the UP/DOWN button to set the desired
cancel the autotimed program, simply adjust the
Swing Button (applicable to RG51F1)
ature setting in 1°F increments to 62°F.
range of 62°F~86°F in 1°F increments.
temperature. The temperature can be set within a
auto-off time to 0.0
Used to stop or start vertical louver movement and
NOTE:Temperature contol is not available in Fan
3. Press the ON/OFF button to start the air conditioner.range of 62°F~86°F in 1°F increments.
set the desired left/right air flow direction. The
mode.
NOTE:In the Dehumidifying mode, you can not switch
3. Press the ON/OFF button to start the air
LOCK Button
vertical louver changes 6 degree in angle for each
NOTE:Press and hold UP and DOWN buttons together
Set
the fan speed. It is automatically controlled.
conditioner.
Press this recessed button to lock all current
press.
for 3 seconds will toggle the temperature display
settings, and the remote control will not accept any
between the °C & °F scales.
Timer operation
NOTE:
operation except that of the LOCK. Use the LOCK
RESET Button
Press the TIMER ON button can set the auto-on
1. In the Auto mode, the air conditioner can logically
mode when you want to prevent settings from
Once the recessed RESET button is pressed, all of
MODE Button
time of the unit. Press the TIMER OFF button can
choose the mode of Cooling, Fan, and Heating by
being changed accidentally. Press the LOCK button
the current settings will be cancelled and the
Press this button to modify the air conditioner
set the auto-off time of the unit.
sensing the difference between the actual ambient
again to cancel the LOCK function. A lock symbol
control will return to the initial settings.
mode in a sequence of following:
To set the Auto-on time:
room temperature and the setting temperature on
will appear on the remote control display when the
AUTO COOL DRY HEAT FAN
1. Press the TIMER ON button. The remote control
the remote control.
lock function is activated.
LED Button
shows TIMER ON, the last Auto-on setting time and
2. In the Auto mode, you can not switch the fan speed.
Disable/Active indoor screen display. When
NOTE:Please do not select HEAT mode if the machine
the signal "H" will be shown on the LCD display
It has already been automatically controlled.
TURBO Button
pushing the button, the indoor screen display is
you purchased is cooling only type. Heat mode is not
area. Now it is ready to reset the Auto-on time to
3. If the Auto mode is not comfortable for you, the
Active/Disable Turbo function. Turbo function
cleared, press it again to light the display.
supported by the cooling only appliance.
START the operation.
desired mode can be selected manually.
enables the unit to reach the preset temperature
O
2. Push the TIMER ON button again to set desired
at cooling or heating operation in the shortest time
ON/OFF Button
SWING Button
Auto-on time. Each time you press the button, the
(if the indoor unit does not support this function,
Operation starts when this button is pressed and
Used to stop or start horizontal louver movement
time increases by half an hour between 0 and 10
there is no corresponding operation happened
stops when the button is pressed again.
or set the desired up/down air flow direction. The
Set
hours and by one hour between 10 and 24 hours.
Cooling/Heating/Fan operation
when pressing this button.)
louver changes 6 degree in angle for each press. If
On
3. After setting the TIMER ON, there will be a one
Ensure the unit is plugged in and power is available.
FAN SPEED Button
keep pushing more than 2 seconds, the louver will
second delay before the remote control transmits
Set 10 hours later
1. Press the MODE button to select COOL, HEAT
NOTE:
Used to select the fan speed in four steps:
swing up and down automatically.the signal to the air conditioner. Then, after
(cooling & heating models only) or FAN mode.
•Buttons design is based on typical model and might
Auto Low Med Highapproximately another 2 seconds, the signal "h" will
2. Press the UP/DOWN buttons to set the
be slightly different from the actual one you
ECO Button
disappear and the set temperature will re-appear
desired temperature. The temperature can be set
purchased the actual shape shall prevail.
TIMER ON Button
Used to enter the energy efficient mode. Under
on the LCD display window.
within a range of 62°F~86°F in 1°F increments.
•All the functions described are accomplished by the
Press this button to initiate the auto-on time
cooling mode, press this button, the remote
To set the Auto-off time:
3. Press the FAN button to select the fan speed in
unit. If the unit has no this feature, there is no
sequence. Each press will increase the auto-timed
control will adjust the temperature automatically
1. Press the TIMER OFF button. The remote control
four steps- Auto, Low, Med, or High.
corresponding operation happened when press the
setting in 30 minutes increments. When the setting
to 75°F, fan speed of Auto to save energy (but only
shows TIMER OFF, the last Auto-off setting time and
4. Press the ON/OFF button to start the air
relative button on the remote controller.
time displays 10.0, each press will increase the
if the set temperature is less than 75°F). If the set
the signal "H" will be shown on the LCD display area.
conditioner.
•When there are differences between the Remote
autotimed setting 60 minutes increments. To
temperature is between 75°F and 86°F, press the
Now it is ready to resetthe Auto-off time to stop the
Control Manual and User Manual on function
cancel the auto-timed program, simply adjust the
ECO button, the fan speed will change to Auto, the
operation.
NOTE:
description, use the description from the User Manual.
auto-on time to 0.0.
set temperature will remain unchanged.
2. Push the TIMER OFF button again to set desired
In the FAN mode, the setting temperature is not
NOTE:
Auto-off time. Each time you press the button, the
displayed in the remote control and you are not able
•Pressing the TURBO and SLEEP button, modifying the
time increases by half an hour between 0 and 10
to control the room temperature either. In this case,
mode or adjusting the set temperature to less than
hours and by one hour between 10 and 24 hours.
only step 1, 3 and 4 may be performed.
75°F will stop ECO operation.
3. After setting the TIMER OFF, there will be a one
•Under ECO operation, the set temperature should be
second delay before the remote control transmits
75°F or more. it may result in insufficient cooling. If
the signal to the air conditioner. Then, after
you feel uncomfortable, just press the ECO button
approximately another 2 seconds, the signal "H" will
again to stop it.
Stop
FAN
HIGH
MED
LOW
O
AUTOCOOLDRYHEAT
2 hours laterafter setting
SWING
SWING
MODE
disappear and the set temperature will re-appear
on the LCD display window.
12
11
10
9
8
7
6
5
4
3
2
1
Start
10 hours later
after setting
Start
6 hours later
SET TEMPERATURE(°F)
Start
TEMP
Stop
ON/OFF
Stop
5 hours laterafter setting
ECO
RESET LOCK
DISPLAY
LED
Model : RG51F1/EU1
2
3
6
7
9
11
FANHIGHMEDLOW
FAN SPEED
TIMER ON
TIMER OFF
TURBO
Please read this manual carefully before installation and keep it for future reference.
For more details visit www.MrCool.com
Handling the Remote Control
Remote Controller Specifications
Timer Operation
Timer Operation
How to use the buttons
How to use the buttons
LCD Indicators
Operation of Buttons
Operation of Buttons
Operation of Buttons
CONTENTS
Information that is displayed when the remote is turned on.
NOTE:
•Use the remote controller within a distance of 26.25ft from the appliance, pointing it towards the
The device could comply with the local national regulations.
receiver. Reception is confirmed by a beep.
•In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
•In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
CAUTION
AUTO
AUTO
2
2
1
1
AUTO
COOL
COOL
COOL
DRY
DRY
DRY
HEAT
HEAT
HEAT
SWING
SWING
SWING
CLEAN
CLEAN
CLEAN
AIR
AIR
AIR
(1) This device may not cause harmful interference, and
•The air conditioner will not operate if curtains, doors or other materials block the signals from the
(2) this device must accept any interference received, including interference that may cause undesired
remote control to the indoor unit.
COMBINED TIMER
operation.
•Prevent any liquid from falling into the remote control. Do not expose the remote control to direct
(Setting both ON and OFF timers simultaneously)
sunlight orheat.
TIMER OFF TIMER ON
This equipment has been tested and found to comply with the limits for a Class B digital device,
•If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may
(On Stop Start operation)
pursuant topart 15 of the FCC Rules. These limits are designed to provide reasonable protection against
not function properly. Use curtains to prevent the sunlight from falling on the receiver.
This featureis useful when you want to stop the air conditioner after you go to bed, and start it again in
2
2
2
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
•If other electrical appliances react to the remote control, either move these appliances or consult your
the morning when you wake up or when you return home.
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
local dealer.
TIMER ON (Auto-on Operation)
EXAMPLE:
interference to radio communications. However, there is no guarantee that interference will not occur
•Do not drop the remote controller. Handle with care.
The TIMER ON feature is useful when you want the unit to turn on automatically before you return
3
3
3
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.
in a particular installation. If this equipment does cause harmful interference to radio or television
•Do not place heavy objects on the remote control, or step on it.
home. The air conditioner will automatically start operating at the set time.
1. Press the TIMER OFF button.
4
4
4
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
EXAMPLE:
2. Pressthe TIMER OFF button again to display 2.0H on the TIMER OFF display.
to correct the interference by one or more of the following measures:
Using the remote control mount (optional)
5
5
5
To start the air conditioner in 6 hours.
3. Press the TIMER ON button.
•Reorient or relocate the receiving antenna.
•The remote controller can be attached to a wall or pillar by using a remote controller holder (not
1. Press the TIMER ON button, the last setting of starting operation time and the signal "h" will show on the
6
6
6
4. Press the TIMER ON button again to display 10H on the TIMER ON display .
•Increase the separation between the equipment and receiver.
supplied, purchased separately).
display area.
5. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
7
7
7
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Before installing the remote controller, check that the air conditioner receives the signals properly.
2. Press the TIMER ON button to display "6.0h" on the TIMER ON display of the remote control.
indicator remains on and this function is activated.
•Consult the dealer or an experienced radio/TV technician for help.
•Install the remote control with two screws. For installing or removing the remote control, move it up
8
8
8
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON" indicator
•Changes or modifications not approved by the party responsible for compliance could void user’s
or down inthe holder.
remains onand this function is activated.
!
CAUTION
The effective operation time set by the remote controller for the timer function is
SET TEMPERATURE ( F)
Remote Control
limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0,
The following cases signify exhausted batteries. Replace old batteries with new ones.
Model:RG51F3/EU1 and
Model:RG51F3/EU1 and
•Receiving beep is not emitted when a signal is transmitted.
•Indicator fades away.
TIMER ON TIMER OFF
The remotecontrol is powed by two dry batteries (R03/LR03X2) housed in the back rear part and
(Off Start Stop operation)
protected by a cover.
TIMER OFF (Auto-off Operation)
This featureis useful when you want to start the air conditioner before you wake up and stop it after
(1) Removethe cover in the rear part of the remote control.
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed.
you leave the house.
(2) Removethe old batteries and insert the new batteries, placing the(+) and (-) ends correctly.
The air conditioner will stop automatically at the set time.
EXAMPLE:
(3) Install the cover back on.
EXAMPLE:
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.
To stop the air conditioner in 10 hours.
1. Press the TIMER ON button.NOTE: Whenthe batteries are removed, the remote control erases all programming. After inserting new
The design and specifications are subject to change without prior notice.
1. Press the TIMER OFF button, the last setting of stopping operation time and the signal "h" will show on the
2. Press the TIMER ON button again to display 2.0H on the TIMER ON display.
batteries, the remote control must be reprogrammed.
display area.
Consultwith the sales agency or manufacturer for details.
3. Press the TIMER OFF button.
2. Press the TIMER OFF button to display "10h" on the TIMER OFF display of the remote control.
4. Press the TIMER OFF button again to display
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER OFF" indicator
5.0H on the TIMER OFF display .
remains onand this function is activated.
5. Wait for 3 seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
indicator remains on and this function is activated.
Model:RG51F3/EU1 andRG51F/EU1(This model does not
RG51F/EU1(This model does not
RG51F/EU1(This model does nothave clean air button
have clean air button
have clean air button
AUTO
COOL
DRY
AUTO
HEAT
COOL
DRY
HEAT
2
CAUTION
1
•Do not mix old and new batteries or batteries of different types.
MODE
MODE
SWING
SWING
SET TEMPERATURE(F)
SET TEMPERATURE(F)
•Do not leave the batteries in the remote control if they are not going to be used for 2 or 3 months.
•Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special
treatment is necessary.
Remote control specifications
Operation of buttons
LCD Indicators
How to use the buttons
Timer operation
User Manual
Handling the remote control
TEMPTEMP
TEMP
TEMP
TEMP
ON/OFFON/OFF
ON/OFF
ON/OFF
ON/OFF
ECOECO
ECO
ECO
ECO
RESET LOCKRESET LOCK
AUTO
RESETLOCK
RESETLOCK
RESETLOCK
DISPLAY
LED
COOL
DISPLAY
LED
DRY
DISPLAY
DISPLAY
DISPLAY
LED
LED
LED
HEAT
Model
O
O
O
O
O
Rated Voltage
Signal Receiving
FAN
Range
HIGH
FAN
FAN
FAN
FAN
Environment
MED
HIGH
HIGH
HIGH
HIGH
LOW
MED
MED
MED
MED
LOW
LOW
LOW
LOW
AUTO
COOL
TIMER ON OFF
DRY
HEAT
Mode display
AUTO: COOL: DRY: HEAT: FAN:
FAN SPEED
Displayed when remote signal is sent.
FAN SPEED
FAN SPEED
FAN SPEED
FAN SPEED
TIMER ON
Displayed when remote control is ON.
TIMER ON
TIMER ON
TIMER ON
TIMER ON
TIMER OFF
SET TEMPERATURE(°F)
TIMER ONDisplayed when TIMER ON time is set.
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFFDisplayed when TIMER OFF time is set.
TURBOTURBO
TURBO
TURBO
TURBO
Show set temperature or room temperature,
22
33
DIY Series
RG51F/EU1, RG51F1/EU1, RG51F3/EU1
3.0V(Dry batteries R 03/LR03 2)
h
8m
62°F~ 86°F
h
TIMERON
1
1
1
9
9
9
10
10
10
11
11
11
FANHIGH
12
12
12
MEDLOW
13
13
13
or time under TIMER setting.
14
14
14
TEMP
Indicated all the current settings are locked.
TIMER ON
TIMER OFF
h
h
MODE
SWING
CLEAN AIR
TEMP
Fan speed indication
ON/OFF
HIGH- High speed
O
MED - Medium speed
ECO
FAN
LOW- Low speed
O
HIGH
No Display - Auto fan speed
MEDFAN
LOW
RESET LOCK
HIGHMED
Note:
LOW
All indicators shown in the figure are for the purpose
DISPLAY
LED
TIMER ONOFF
FAN SPEED
TIMEROFF
TURBO
of clear presentation. But during the actual operation
TEMPON/OFF
ON/OFF
ECO
ECO
RESET LOCK
LED
RESET LOCK
LED
only the relative functional signs are shown on the
display window.
FAN SPEED
TIMER ON
FAN SPEED
TIMER OFF
TIMER ON
Model:RG51F3/EU1
RG51F/EU1(This model does not
TIMER OFF
DISPLAY
TURBO
have clean air button)
DISPLAY
TURBO
2
3
1
4
2
DIY Series
Please keep this manual where the operator can easily find it.
Inside you will find helpful hints on how to use and maintain your
unit properly.
Dehumidifying operation
6
1
TIMER OFF Button
CLEAN AIR Button (applicable to RG51F3)
TEMP UP Button
12
Ensure the unit is plugged in and power is available.
Auto operation
Press this button to initiate the auto-off time
Disable/Active clean air function. When the clean
Push this button to increase the indoor temperThe OPERATION indicator on the display panel of
On
Ensure the unit is plugged in and power is
sequence. Each press will increase the auto-timed
air function is initiated, the Ionizer/Plasma Dust
ature setting in 1°F increments to 86°F.
the indoor unit starts flashing.
available. The OPERATION indicator on the display
setting in 30 minutes increments. When the setting
Collector (depending on models) is energized and
Set
2 hours later
1. Press the MODE button to select DRY mode.
2
TIMER ON OFF
13
73
8
14
9
4
10
5
11
after setting
panel of the indoor unit starts flashing.
time displays 10.0, each press will increase the
will help to remove pollen and impurities from the
TEMP DOWN Button
2. Press the UP/DOWN buttons to set the desired
1. Press the MODE button to select Auto.
auto-timed setting 60 minutes increments. To
air.
Push this button to decrease the indoor temper temperature. The temperature can be set within a
2. Press the UP/DOWN button to set the desired
cancel the autotimed program, simply adjust the
Swing Button (applicable to RG51F1)
ature setting in 1°F increments to 62°F.
range of 62°F~86°F in 1°F increments.
temperature. The temperature can be set within a
auto-off time to 0.0
Used to stop or start vertical louver movement and
NOTE:Temperature contol is not available in Fan
3. Press the ON/OFF button to start the air conditioner.range of 62°F~86°F in 1°F increments.
set the desired left/right air flow direction. The
mode.
NOTE:In the Dehumidifying mode, you can not switch
3. Press the ON/OFF button to start the air
LOCK Button
vertical louver changes 6 degree in angle for each
NOTE:Press and hold UP and DOWN buttons together
Set
the fan speed. It is automatically controlled.
conditioner.
Press this recessed button to lock all current
press.
for 3 seconds will toggle the temperature display
settings, and the remote control will not accept any
between the °C & °F scales.
Timer operation
NOTE:
operation except that of the LOCK. Use the LOCK
RESET Button
Press the TIMER ON button can set the auto-on
1. In the Auto mode, the air conditioner can logically
mode when you want to prevent settings from
Once the recessed RESET button is pressed, all of
MODE Button
time of the unit. Press the TIMER OFF button can
choose the mode of Cooling, Fan, and Heating by
being changed accidentally. Press the LOCK button
the current settings will be cancelled and the
Press this button to modify the air conditioner
set the auto-off time of the unit.
sensing the difference between the actual ambient
again to cancel the LOCK function. A lock symbol
control will return to the initial settings.
mode in a sequence of following:
To set the Auto-on time:
room temperature and the setting temperature on
will appear on the remote control display when the
AUTO COOL DRY HEAT FAN
1. Press the TIMER ON button. The remote control
the remote control.
lock function is activated.
LED Button
shows TIMER ON, the last Auto-on setting time and
2. In the Auto mode, you can not switch the fan speed.
Disable/Active indoor screen display. When
NOTE:Please do not select HEAT mode if the machine
the signal "H" will be shown on the LCD display
It has already been automatically controlled.
TURBO Button
pushing the button, the indoor screen display is
you purchased is cooling only type. Heat mode is not
area. Now it is ready to reset the Auto-on time to
3. If the Auto mode is not comfortable for you, the
Active/Disable Turbo function. Turbo function
cleared, press it again to light the display.
supported by the cooling only appliance.
START the operation.
desired mode can be selected manually.
enables the unit to reach the preset temperature
O
2. Push the TIMER ON button again to set desired
at cooling or heating operation in the shortest time
ON/OFF Button
SWING Button
Auto-on time. Each time you press the button, the
(if the indoor unit does not support this function,
Operation starts when this button is pressed and
Used to stop or start horizontal louver movement
time increases by half an hour between 0 and 10
there is no corresponding operation happened
stops when the button is pressed again.
or set the desired up/down air flow direction. The
Set
hours and by one hour between 10 and 24 hours.
Cooling/Heating/Fan operation
when pressing this button.)
louver changes 6 degree in angle for each press. If
On
3. After setting the TIMER ON, there will be a one
Ensure the unit is plugged in and power is available.
FAN SPEED Button
keep pushing more than 2 seconds, the louver will
second delay before the remote control transmits
Set 10 hours later
1. Press the MODE button to select COOL, HEAT
NOTE:
Used to select the fan speed in four steps:
swing up and down automatically.the signal to the air conditioner. Then, after
(cooling & heating models only) or FAN mode.
•Buttons design is based on typical model and might
Auto Low Med Highapproximately another 2 seconds, the signal "h" will
2. Press the UP/DOWN buttons to set the
be slightly different from the actual one you
ECO Button
disappear and the set temperature will re-appear
desired temperature. The temperature can be set
purchased the actual shape shall prevail.
TIMER ON Button
Used to enter the energy efficient mode. Under
on the LCD display window.
within a range of 62°F~86°F in 1°F increments.
•All the functions described are accomplished by the
Press this button to initiate the auto-on time
cooling mode, press this button, the remote
To set the Auto-off time:
3. Press the FAN button to select the fan speed in
unit. If the unit has no this feature, there is no
sequence. Each press will increase the auto-timed
control will adjust the temperature automatically
1. Press the TIMER OFF button. The remote control
four steps- Auto, Low, Med, or High.
corresponding operation happened when press the
setting in 30 minutes increments. When the setting
to 75°F, fan speed of Auto to save energy (but only
shows TIMER OFF, the last Auto-off setting time and
4. Press the ON/OFF button to start the air
relative button on the remote controller.
time displays 10.0, each press will increase the
if the set temperature is less than 75°F). If the set
the signal "H" will be shown on the LCD display area.
conditioner.
•When there are differences between the Remote
autotimed setting 60 minutes increments. To
temperature is between 75°F and 86°F, press the
Now it is ready to resetthe Auto-off time to stop the
Control Manual and User Manual on function
cancel the auto-timed program, simply adjust the
ECO button, the fan speed will change to Auto, the
operation.
NOTE:
description, use the description from the User Manual.
auto-on time to 0.0.
set temperature will remain unchanged.
2. Push the TIMER OFF button again to set desired
In the FAN mode, the setting temperature is not
NOTE:
Auto-off time. Each time you press the button, the
displayed in the remote control and you are not able
•Pressing the TURBO and SLEEP button, modifying the
time increases by half an hour between 0 and 10
to control the room temperature either. In this case,
mode or adjusting the set temperature to less than
hours and by one hour between 10 and 24 hours.
only step 1, 3 and 4 may be performed.
75°F will stop ECO operation.
3. After setting the TIMER OFF, there will be a one
•Under ECO operation, the set temperature should be
second delay before the remote control transmits
75°F or more. it may result in insufficient cooling. If
the signal to the air conditioner. Then, after
you feel uncomfortable, just press the ECO button
approximately another 2 seconds, the signal "H" will
again to stop it.
Stop
FAN
HIGH
MED
LOW
O
AUTOCOOLDRYHEAT
2 hours laterafter setting
SWING
SWING
MODE
disappear and the set temperature will re-appear
on the LCD display window.
12
11
10
9
8
7
6
5
4
3
2
1
Start
10 hours later
after setting
Start
6 hours later
SET TEMPERATURE(°F)
Start
TEMP
Stop
ON/OFF
Stop
5 hours laterafter setting
ECO
RESET LOCK
DISPLAY
LED
Model : RG51F1/EU1
2
3
6
7
9
11
FANHIGHMEDLOW
FAN SPEED
TIMER ON
TIMER OFF
TURBO
Please read this manual carefully before installation and keep it for future reference.
For more details visit www.MrCool.com
Handling the Remote Control
Remote Controller Specifications
Timer Operation
Timer Operation
How to use the buttons
How to use the buttons
LCD Indicators
Operation of Buttons
Operation of Buttons
Operation of Buttons
CONTENTS
Information that is displayed when the remote is turned on.
NOTE:
•Use the remote controller within a distance of 26.25ft from the appliance, pointing it towards the
The device could comply with the local national regulations.
receiver. Reception is confirmed by a beep.
•In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
•In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
CAUTION
AUTO
AUTO
2
2
1
1
AUTO
COOL
COOL
COOL
DRY
DRY
DRY
HEAT
HEAT
HEAT
SWING
SWING
SWING
CLEAN
CLEAN
CLEAN
AIR
AIR
AIR
(1) This device may not cause harmful interference, and
•The air conditioner will not operate if curtains, doors or other materials block the signals from the
(2) this device must accept any interference received, including interference that may cause undesired
remote control to the indoor unit.
COMBINED TIMER
operation.
•Prevent any liquid from falling into the remote control. Do not expose the remote control to direct
(Setting both ON and OFF timers simultaneously)
sunlight orheat.
TIMER OFF TIMER ON
This equipment has been tested and found to comply with the limits for a Class B digital device,
•If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may
(On Stop Start operation)
pursuant topart 15 of the FCC Rules. These limits are designed to provide reasonable protection against
not function properly. Use curtains to prevent the sunlight from falling on the receiver.
This featureis useful when you want to stop the air conditioner after you go to bed, and start it again in
2
2
2
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
•If other electrical appliances react to the remote control, either move these appliances or consult your
the morning when you wake up or when you return home.
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
local dealer.
TIMER ON (Auto-on Operation)
EXAMPLE:
interference to radio communications. However, there is no guarantee that interference will not occur
•Do not drop the remote controller. Handle with care.
The TIMER ON feature is useful when you want the unit to turn on automatically before you return
3
3
3
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.
in a particular installation. If this equipment does cause harmful interference to radio or television
•Do not place heavy objects on the remote control, or step on it.
home. The air conditioner will automatically start operating at the set time.
1. Press the TIMER OFF button.
4
4
4
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
EXAMPLE:
2. Pressthe TIMER OFF button again to display 2.0H on the TIMER OFF display.
to correct the interference by one or more of the following measures:
Using the remote control mount (optional)
5
5
5
To start the air conditioner in 6 hours.
3. Press the TIMER ON button.
•Reorient or relocate the receiving antenna.
•The remote controller can be attached to a wall or pillar by using a remote controller holder (not
1. Press the TIMER ON button, the last setting of starting operation time and the signal "h" will show on the
6
6
6
4. Press the TIMER ON button again to display 10H on the TIMER ON display .
•Increase the separation between the equipment and receiver.
supplied, purchased separately).
display area.
5. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
7
7
7
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Before installing the remote controller, check that the air conditioner receives the signals properly.
2. Press the TIMER ON button to display "6.0h" on the TIMER ON display of the remote control.
indicator remains on and this function is activated.
•Consult the dealer or an experienced radio/TV technician for help.
•Install the remote control with two screws. For installing or removing the remote control, move it up
8
8
8
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER ON" indicator
•Changes or modifications not approved by the party responsible for compliance could void user’s
or down inthe holder.
remains onand this function is activated.
!
CAUTION
The effective operation time set by the remote controller for the timer function is
SET TEMPERATURE ( F)
Remote Control
limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0,
The following cases signify exhausted batteries. Replace old batteries with new ones.
Model:RG51F3/EU1 and
Model:RG51F3/EU1 and
•Receiving beep is not emitted when a signal is transmitted.
•Indicator fades away.
TIMER ON TIMER OFF
The remotecontrol is powed by two dry batteries (R03/LR03X2) housed in the back rear part and
(Off Start Stop operation)
protected by a cover.
TIMER OFF (Auto-off Operation)
This featureis useful when you want to start the air conditioner before you wake up and stop it after
(1) Removethe cover in the rear part of the remote control.
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed.
you leave the house.
(2) Removethe old batteries and insert the new batteries, placing the(+) and (-) ends correctly.
The air conditioner will stop automatically at the set time.
EXAMPLE:
(3) Install the cover back on.
EXAMPLE:
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.
To stop the air conditioner in 10 hours.
1. Press the TIMER ON button.NOTE: Whenthe batteries are removed, the remote control erases all programming. After inserting new
The design and specifications are subject to change without prior notice.
1. Press the TIMER OFF button, the last setting of stopping operation time and the signal "h" will show on the
2. Press the TIMER ON button again to display 2.0H on the TIMER ON display.
batteries, the remote control must be reprogrammed.
display area.
Consultwith the sales agency or manufacturer for details.
3. Press the TIMER OFF button.
2. Press the TIMER OFF button to display "10h" on the TIMER OFF display of the remote control.
4. Press the TIMER OFF button again to display
3. Wait for 3seconds and the digital display area will show the temperature again. The "TIMER OFF" indicator
5.0H on the TIMER OFF display .
remains onand this function is activated.
5. Wait for 3 seconds and the digital display area will show the temperature again. The "TIMER ON OFF"
indicator remains on and this function is activated.
Model:RG51F3/EU1 andRG51F/EU1(This model does not
RG51F/EU1(This model does not
RG51F/EU1(This model does nothave clean air button
have clean air button
have clean air button
AUTO
COOL
DRY
AUTO
HEAT
COOL
DRY
HEAT
2
CAUTION
1
•Do not mix old and new batteries or batteries of different types.
MODE
MODE
SWING
SWING
SET TEMPERATURE(F)
SET TEMPERATURE(F)
•Do not leave the batteries in the remote control if they are not going to be used for 2 or 3 months.
•Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special
treatment is necessary.
Remote control specifications
Operation of buttons
LCD Indicators
How to use the buttons
Timer operation
User Manual
Handling the remote control
TEMPTEMP
TEMP
TEMP
TEMP
ON/OFFON/OFF
ON/OFF
ON/OFF
ON/OFF
ECOECO
ECO
ECO
ECO
RESET LOCKRESET LOCK
AUTO
RESETLOCK
RESETLOCK
RESETLOCK
DISPLAY
LED
COOL
DISPLAY
LED
DRY
DISPLAY
DISPLAY
DISPLAY
LED
LED
LED
HEAT
Model
O
O
O
O
O
Rated Voltage
Signal Receiving
FAN
Range
HIGH
FAN
FAN
FAN
FAN
Environment
MED
HIGH
HIGH
HIGH
HIGH
LOW
MED
MED
MED
MED
LOW
LOW
LOW
LOW
AUTO
COOL
TIMER ON OFF
DRY
HEAT
Mode display
AUTO: COOL: DRY: HEAT: FAN:
FAN SPEED
Displayed when remote signal is sent.
FAN SPEED
FAN SPEED
FAN SPEED
FAN SPEED
TIMER ON
Displayed when remote control is ON.
TIMER ON
TIMER ON
TIMER ON
TIMER ON
TIMER OFF
SET TEMPERATURE(°F)
TIMER ONDisplayed when TIMER ON time is set.
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFF
TIMER OFFDisplayed when TIMER OFF time is set.
TURBOTURBO
TURBO
TURBO
TURBO
Show set temperature or room temperature,
22
33
DIY Series
RG51F/EU1, RG51F1/EU1, RG51F3/EU1
3.0V(Dry batteries R 03/LR03 2)
h
8m
62°F~ 86°F
h
TIMERON
1
1
1
9
9
9
10
10
10
11
11
11
FANHIGH
12
12
12
MEDLOW
13
13
13
or time under TIMER setting.
14
14
14
TEMP
Indicated all the current settings are locked.
TIMER ON
TIMER OFF
h
h
MODE
SWING
CLEAN AIR
TEMP
Fan speed indication
ON/OFF
HIGH- High speed
O
MED - Medium speed
ECO
FAN
LOW- Low speed
O
HIGH
No Display - Auto fan speed
MEDFAN
LOW
RESET LOCK
HIGHMED
Note:
LOW
All indicators shown in the figure are for the purpose
DISPLAY
LED
TIMER ONOFF
FAN SPEED
TIMEROFF
TURBO
of clear presentation. But during the actual operation
TEMPON/OFF
ON/OFF
ECO
ECO
RESET LOCK
LED
RESET LOCK
LED
only the relative functional signs are shown on the
display window.
FAN SPEED
TIMER ON
FAN SPEED
TIMER OFF
TIMER ON
Model:RG51F3/EU1
RG51F/EU1(This model does not
TIMER OFF
DISPLAY
TURBO
have clean air button)
DISPLAY
TURBO
2
3
1
4
2
DIY Series
Please keep this manual where the operator can easily find it.
Inside you will find helpful hints on how to use and maintain your
unit properly.
Dehumidifying operation
6
1
TIMER OFF Button
CLEAN AIR Button (applicable to RG51F3)
TEMP UP Button
12
Ensure the unit is plugged in and power is available.
Auto operation
Press this button to initiate the auto-off time
Disable/Active clean air function. When the clean
Push this button to increase the indoor temperThe OPERATION indicator on the display panel of
On
Ensure the unit is plugged in and power is
sequence. Each press will increase the auto-timed
air function is initiated, the Ionizer/Plasma Dust
ature setting in 1°F increments to 86°F.
the indoor unit starts flashing.
available. The OPERATION indicator on the display
setting in 30 minutes increments. When the setting
Collector (depending on models) is energized and
Set
2 hours later
1. Press the MODE button to select DRY mode.
2
TIMER ON OFF
13
73
8
14
9
4
10
5
11
after setting
panel of the indoor unit starts flashing.
time displays 10.0, each press will increase the
will help to remove pollen and impurities from the
TEMP DOWN Button
2. Press the UP/DOWN buttons to set the desired
1. Press the MODE button to select Auto.
auto-timed setting 60 minutes increments. To
air.
Push this button to decrease the indoor temper temperature. The temperature can be set within a
2. Press the UP/DOWN button to set the desired
cancel the autotimed program, simply adjust the
Swing Button (applicable to RG51F1)
ature setting in 1°F increments to 62°F.
range of 62°F~86°F in 1°F increments.
temperature. The temperature can be set within a
auto-off time to 0.0
Used to stop or start vertical louver movement and
NOTE:Temperature contol is not available in Fan
3. Press the ON/OFF button to start the air conditioner.range of 62°F~86°F in 1°F increments.
set the desired left/right air flow direction. The
mode.
NOTE:In the Dehumidifying mode, you can not switch
3. Press the ON/OFF button to start the air
LOCK Button
vertical louver changes 6 degree in angle for each
NOTE:Press and hold UP and DOWN buttons together
Set
the fan speed. It is automatically controlled.
conditioner.
Press this recessed button to lock all current
press.
for 3 seconds will toggle the temperature display
settings, and the remote control will not accept any
between the °C & °F scales.
Timer operation
NOTE:
operation except that of the LOCK. Use the LOCK
RESET Button
Press the TIMER ON button can set the auto-on
1. In the Auto mode, the air conditioner can logically
mode when you want to prevent settings from
Once the recessed RESET button is pressed, all of
MODE Button
time of the unit. Press the TIMER OFF button can
choose the mode of Cooling, Fan, and Heating by
being changed accidentally. Press the LOCK button
the current settings will be cancelled and the
Press this button to modify the air conditioner
set the auto-off time of the unit.
sensing the difference between the actual ambient
again to cancel the LOCK function. A lock symbol
control will return to the initial settings.
mode in a sequence of following:
To set the Auto-on time:
room temperature and the setting temperature on
will appear on the remote control display when the
AUTO COOL DRY HEAT FAN
1. Press the TIMER ON button. The remote control
the remote control.
lock function is activated.
LED Button
shows TIMER ON, the last Auto-on setting time and
2. In the Auto mode, you can not switch the fan speed.
Disable/Active indoor screen display. When
NOTE:Please do not select HEAT mode if the machine
the signal "H" will be shown on the LCD display
It has already been automatically controlled.
TURBO Button
pushing the button, the indoor screen display is
you purchased is cooling only type. Heat mode is not
area. Now it is ready to reset the Auto-on time to
3. If the Auto mode is not comfortable for you, the
Active/Disable Turbo function. Turbo function
cleared, press it again to light the display.
supported by the cooling only appliance.
START the operation.
desired mode can be selected manually.
enables the unit to reach the preset temperature
O
2. Push the TIMER ON button again to set desired
at cooling or heating operation in the shortest time
ON/OFF Button
SWING Button
Auto-on time. Each time you press the button, the
(if the indoor unit does not support this function,
Operation starts when this button is pressed and
Used to stop or start horizontal louver movement
time increases by half an hour between 0 and 10
there is no corresponding operation happened
stops when the button is pressed again.
or set the desired up/down air flow direction. The
Set
hours and by one hour between 10 and 24 hours.
Cooling/Heating/Fan operation
when pressing this button.)
louver changes 6 degree in angle for each press. If
On
3. After setting the TIMER ON, there will be a one
Ensure the unit is plugged in and power is available.
FAN SPEED Button
keep pushing more than 2 seconds, the louver will
second delay before the remote control transmits
Set 10 hours later
1. Press the MODE button to select COOL, HEAT
NOTE:
Used to select the fan speed in four steps:
swing up and down automatically.the signal to the air conditioner. Then, after
(cooling & heating models only) or FAN mode.
•Buttons design is based on typical model and might
Auto Low Med Highapproximately another 2 seconds, the signal "h" will
2. Press the UP/DOWN buttons to set the
be slightly different from the actual one you
ECO Button
disappear and the set temperature will re-appear
desired temperature. The temperature can be set
purchased the actual shape shall prevail.
TIMER ON Button
Used to enter the energy efficient mode. Under
on the LCD display window.
within a range of 62°F~86°F in 1°F increments.
•All the functions described are accomplished by the
Press this button to initiate the auto-on time
cooling mode, press this button, the remote
To set the Auto-off time:
3. Press the FAN button to select the fan speed in
unit. If the unit has no this feature, there is no
sequence. Each press will increase the auto-timed
control will adjust the temperature automatically
1. Press the TIMER OFF button. The remote control
four steps- Auto, Low, Med, or High.
corresponding operation happened when press the
setting in 30 minutes increments. When the setting
to 75°F, fan speed of Auto to save energy (but only
shows TIMER OFF, the last Auto-off setting time and
4. Press the ON/OFF button to start the air
relative button on the remote controller.
time displays 10.0, each press will increase the
if the set temperature is less than 75°F). If the set
the signal "H" will be shown on the LCD display area.
conditioner.
•When there are differences between the Remote
autotimed setting 60 minutes increments. To
temperature is between 75°F and 86°F, press the
Now it is ready to resetthe Auto-off time to stop the
Control Manual and User Manual on function
cancel the auto-timed program, simply adjust the
ECO button, the fan speed will change to Auto, the
operation.
NOTE:
description, use the description from the User Manual.
auto-on time to 0.0.
set temperature will remain unchanged.
2. Push the TIMER OFF button again to set desired
In the FAN mode, the setting temperature is not
NOTE:
Auto-off time. Each time you press the button, the
displayed in the remote control and you are not able
•Pressing the TURBO and SLEEP button, modifying the
time increases by half an hour between 0 and 10
to control the room temperature either. In this case,
mode or adjusting the set temperature to less than
hours and by one hour between 10 and 24 hours.
only step 1, 3 and 4 may be performed.
75°F will stop ECO operation.
3. After setting the TIMER OFF, there will be a one
•Under ECO operation, the set temperature should be
second delay before the remote control transmits
75°F or more. it may result in insufficient cooling. If
the signal to the air conditioner. Then, after
you feel uncomfortable, just press the ECO button
approximately another 2 seconds, the signal "H" will
again to stop it.
Stop
FAN
HIGH
MED
LOW
O
AUTOCOOLDRYHEAT
2 hours laterafter setting
SWING
SWING
MODE
disappear and the set temperature will re-appear
on the LCD display window.
12
11
10
9
8
7
6
5
4
3
2
1
Start
10 hours later
after setting
Start
6 hours later
SET TEMPERATURE(°F)
Start
TEMP
Stop
ON/OFF
Stop
5 hours laterafter setting
ECO
RESET LOCK
DISPLAY
LED
Model : RG51F1/EU1
2
3
6
7
9
11
FANHIGHMEDLOW
FAN SPEED
TIMER ON
TIMER OFF
TURBO
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.