PRODUCT SPECIFICATIONS
GAS FURNACE
VENTING
• • Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe
INSTALLATION FEATURES
• Left or right utility connection
• Designed certified for direct and non-direct vent applications
• Zero step horizontal conversion
• • Removable oor base for bottom return air Complies with California’s South Coast Air Quality Management
district Low NOx requirements
WARRANTY
10 year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details.
CONFIGURATIONS
Upflow/Horizontal
• Downflow
HEAT EXCHANGER DESIGN
• AL 29-4C Stainless steel secondary heat exchanger
BURNER
• Aluminized steel inshot burners for smooth t
CABINET DESIGN
• Compact 33" height
• Standardized widths for easy coil t
AIR DELIVERY SYSTEM
Multi-speed high efficiency (constant torque) blower motor
• Easily removable slide-out blower design
CONTROLS
• Single stage gas valve
• • Self diagnostics saves last 10 fault codes regardless of power interruption
Control features electronic air cleaner and humidifier terminals
mrcool.com
Page 1
95% GAS FURNACE MGM95S*A & MGD95S*A
MODEL NUMBER GUIDE
M G M 95 S C 45 A 3 A
COMPANY
M = MRCOOL
GAS
G = GAS FURNACE
AIRFLOW
M = MULTI-POSITION D = DOWNFLOW
AFUE
ANNUAL FUEL UTILIZATION EFFICIENCY
STAGE
S = SINGLE STAGE / MULTI SPEED
MOTOR
C = PSC E = ECM
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nom.
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
REV CODE
A = 2ND GENERATION
CFM
2 = 800, 3 = 1200, 4 = 1600, 5 = 2000
CABINET SIZE
A = 14.5 B = 17.5 C = 21 D = 24.5
BTU
Max. Time
Delay Breaker or Fuse
Nominal
F.L.A.
Trans. (V.A.)
Approx.
Shipping
Weight
(lbs.)
MGM95SE045B3XA 44,000 42,000 95.0% 1-1/2 — 3 1/2 120 - 60 - 1 15 6.8 40 129
MGM95SE070B3XA 66,000 64,000 95.0% 1-1/2 — 3 1/2 120 - 60 - 1 15 6.8 40 134
MGM95SE090C4XA 88,000 85,000 95.0% 2-1/2 — 4 1/2 120 - 60 - 1 15 8.4 40 158
MGM95SE110C5XA 110,000 106,000 95.0% 3 — 5 1/2 120 - 60 - 1 15 10.9 40 170
UPFLOW/HORIZONTAL
MGM95SE135D5XA 132,000 128,000 95.0% 3-1/2 — 5 1/2 120 - 60 - 1 15 10.9 40 187
MGD95SE045B3XA 44,000 42,000 95.0% 1-1/2 — 3 1/2 120 - 60 - 1 15 6.8 40 131
MGD95SE070B4XA 66,000 64,000 95.0% 2-1/2 — 4 1/2 120 - 60 - 1 15 8.4 40 144
MGD95SE090C4XA 88,000 85,000 95.0% 2-1/2 — 4 1/2 120 - 60 - 1 15 8.4 40 160
DOWNFLOW
MGD95SE110C5XA 110,000 106,000 95.0% 3 — 5 1/2 120 - 60 - 1 15 10.9 40 174
Note: For vent length and clearances to combustibles, please reference installation instr uctions.