EVAPORATOR COILS
PRODUCT SPECIFICATIONS
EVAPORATOR COILS FEATURES
• Microban® antimicrobial additive in the drain pan to resist mold and
mildew growth.
• Aluminum tubing, hairpins, distributors and header tubes. Copper
refrigerant connections for easy brazing to both liquid and suction
lines.
• Preformed flanges in outlet for quick and easy plenum connections
• One of the lowest water retention drain pans in the industry to
minimize mold and mildew growth.
• Interlocking door assemblies and snug line seal grommets to
minimize air leakage
• Foil-face insulation for easy cleaning
• Tubing located at door split for easy coil service or cleaning
• All drain pans are compatible with UV lights
• All piston coils are compatible with R22 or R410a
• 10-year limited parts warranty available when applied with a system.
See limited warranty document for details.
Upflow/Counterflow Coils
MCVP*NPA (Cased)
• External cabinet mounted distributor body designed for easy changing of orifice sizes and fast TXV connections
• Single protruding right side dual drain port for easy installation and service access.
Horizontal Coils
MCHP*NPA (Cased)
• Dedicated horizontal
• Insulated galvanized steel case with durable embossed finish
• Removable panels provide access to coil.
• Refrigerant lines extend outside of the cabinet for easy connection.
Downflow Coils
MCDP*NPA (Cased)
• Heavy-gauge steel constructed cabinet for optimal support of the furnace, no
need for additional bracing or structure.
• Inlet openings matched to furnace models for easy installation and no adapters
needed*
• Removable Cabinet panels for easy coil service
• Single protruding dual drain port for easy installation and service access
WARRANTY
10 year limited parts warranty available when applied with a
system. See limitied warranty document for details.
mrcool.com
Page 1
EVAPORATOR COILS MCHP*NPA | MCVP*NPA | MCDP*NPA
MODEL NUMBER GUIDE
M C V P 24 A N P A
SERIES
MRCOOL
C = COIL
AIR FLOW
M = UPFLOW/HORIZONTAL
V = UPFLOW
H = HORIZONTAL
C = UNPAINTED
U = UNCASED
P = PAINTED
18, 19 = 1.5 TON
23, 24 = 2.0 TON
29, 30 = 2.5 TON
35, 36 = 3.0 TON
METERING DEVICE
O = ORIFICE, T = TXV
C = CAPILLARY, P = PISTON
REFRIGERANT
N = R410 , R = R-22
COIL DIMENSION
A = 14.5 , B = 17.5 ,
C = 21 , D = 24.5
NOMINAL CAPACITY
42 = 3.5 TON
43 = 3.5/4.0 TON
48, 49, 50 = 4.0 TON
60, 61, 62 = 5.0 TON
MCVP*
AIR RESISTANCE
Model
No.
Air
Volume
cfm in. w.g. in. w.g.
Total Resistance
Dry Coil Wet Coil
MCVP24ANPA 400 0.05 0.05
600 0.09 0.10
800 0.16 0.18
1000 0.23 0.26
1200 0.32 0.36
MCVP24BNPA 400 0.03 0.04
600 0.07 0.09
800 0.11 0.15
1000 0.17 0.22
1200 0.23 0.31
MCVP30ANPA 600 0.07 0.08
800 0.12 0.13
1000 0.18 0.20
1200 0.26 0.28
1400 0.34 0.37
MCVP30BNPA 600 0.06 0.06
800 0.09 0.11
1000 0.13 0.16
1200 0.19 0.23
1400 0.25 0.31
800 0.08 0.11
1000 0.13 0.16
MCVP36BNPA
1200 0.17 0.21
1400 0.22 0.28
1600 0.29 0.34
Model
No.
Air
Volume
cfm in. w.g. in. w.g.
MCVP48BNPA 1000 0.13 0.13
1200 0.18 0.18
1400 0.23 0.24
1600 0.30 0.31
1800 0.37 0.40
MCVP48CNPA 1000 0.07 0.09
1200 0.10 0.12
1400 0.13 0.16
1600 0.16 0.20
1800 0.20 0.24
MCVP49CNPA 1200 0.08 0.12
1400 0.13 0.17
1600 0.17 0.22
1800 0.22 0.28
2000 0.28 0.35
MCVP60CNPA 1400 0.15 0.19
1600 0.19 0.23
1800 0.24 0.28
2000 0.29 0.34
2200 0.33 0.40
2400 0.39 0.46
Total Resistance
Dry Coil Wet Coil
mrcool.com
Page 2