Compact design & easy maintenance
18 SEER
Inverter Ducted Air Conditioner
For more details visit www.mrcool.com
This newly designed high eciency household air conditioner works hard saving consumers’ money from the very beginning. With its competitive purchase price to cost - saving 18 SEER eciency, this unit can be installed in many dierent applications: single family homes, villas, oce buidings, hotels, etc.
High Efficiency
For more details visit www.mrcool.com
High Eciency Inverter Compressor
Large-power Startup and Low-power Operation
The DC inverter compressor will run cooling at the largest power input and largest airflow each time it is started until the set temperature is approached. Then, it runs at a low speed and low power input, which will not only keep the temperature from fluctuating, but will also avoid frequent starting and stopping of the compressor, in result, prolonging its service life.
Taking a room of 160ft2 as an example, the air conditioning time of the DC inverter unit is 6-10 minutes shorter then that of the non-inverter one. After the set temperature is reached, the DC inverter compressor will run using 90% less energy then the non-inverter compressor, therefore resulting in temperature loss being controlled and keeping temperatures at steady settings. Which cuts down on the electrical consumption and greatly improves the energy eciency.
Temperature fluctation of the room
Less Cool (Uncomfortable)
Comfortable
Cooler (Uncomfortable)
DC Inverter Non Inverter
High Eciency PMSM
As for the DC inverter compressor with the permanent magnetic synchronous motor (PMSM), there is no current through the motor rotor, no eddy current loss, and little heat produced, which means less ineective power loss so that the motor’s efficiency is improved and the power input is reduced greatly.
DC Inverter MotorAC Induction Motor
INPUT
Iron loss
2nd copper loss
1st copper loss
Eddy current loss
OUTPUT
N
Magnet
S
INPUT
Iron loss
1st copper loss
OUTPUT
No 2nd copper loss
No Eddy current loss
High Efficiency
For more details visit www.mrcool.com
High Eciency Fan Motor
High-efficiency motors are used and will save power significantly.
Stepless Regulation
According to customer’s needs, system output and operating frequency can realize stepless regulation within 10%~120% and 22Hz~80Hz respectively. Thus, energy efficiency is improved.
180° Vector Control technology
With DC Inverter 180° Vector Control technology, the compressor can run more smoothly. According to spectral analysis, the harmonic wave of the DC inverter compressor is smaller than that of a common inverter compressor. With lesser heat output and higher energy efficiency, the motor can save up to 20% energy consumption per year.
High Eciency Heat Exchanger
High Eciency Fan Motor
Micro Channel Heat Exchanger*
Micro Channel Heat Exchanger (MCHX) transfers heat trough multiple flat fluid-filled tubes containing small channels, which can enhance the heat transfer coefficient so that the heat exchange efficiency is increased by 30% compared to the normal fined tube heater exchanger.
Note * for cooling only condensing unit.
Evaporator
Inner Groove Copper Pipe
Special thickened inner groove copper tube enhances heat exchanging performance.
Hydrophilic Blue Fin
Highly anti-corrosion blue hydrophilic coated aluminum fin has longer lifespan than common fin. Heat exchange circuit is optimized in design to best utilize the heat exchanging capacity of evaporator.
3
Better Comfort
For more details visit www.mrcool.com
Quiet Design
Low Running Noise with Quality Insulation
The inverter compressor is insulated with a high quality noise absorption sponge, which is capable of reducing the running noise remarkably, e.g. by 3-4dB at the highest frequency.
Comfortable Airflow
Lower Running Noise at Lower Running Frequency
The inverter compressor and fuzzy control technology, adopted by inverter air conditioner, are able to control the cooling speed according to the indoor temperature change. It features the low noise and it is proved by the test that the noise of the inverter air conditioner is lower and service life is 5-8 years longer, compared with the non-inverter air conditioner.
Low Noise Fan Motor
System adopts low noise motor and optimized 3-dimensional stream blades so that there is lower noise while efficiency is ensured.
High ESP Design
The high static pressure design of indoor unit can ensure enough air volume for every room that is connected to the system. Comfort level of every room is guaranteed.
High ESP Design
The duct connects with multiple diusers to ensure even distribution of airflow and optimizes the air quality.
High Reliability
For more details visit www.mrcool.com
Strong Anti-corrosion
Moisture Resistance and Damp-proof
This system can still operate reliably even under damp or wet conditions, thanks to both the damp-proof design of the electric box and the damp-proof oil that coats the control board.
Humidity-status tests (working condition: 30/29) and rainfall tests (full-range and severe rainfall on the entire unit) have been taken to the system. Moisture resistance grade is IP24.
187 V
Safe Operation Range
254 V
Anti-corrosive
The outer case of outdoor unit is made of painted steel and galvanized to prevent corrosion and rust eectively.
It passed a 1000-hour test in salt mist and proved to be corrosion-proof.
Wide Operation Voltage Range
The unit can safely operate within 187~254V.
High/low pressure protection
When suction pressure is too low or discharge pressure is too high, compressor will stop, and unit displays a malfunction code.
Over current protection
Once the current of the compressor is higher than the normal level, compressor will stop and the unit will display a malfunction code.
Reverse (open) phase protection
Once the phase sequence of power supply is incongruent or the phase is absent, unit will shut o to protect itself from damage.
Comprehensive Protection
Overload protection
Compressor has its own overheat protection. Once the temperature of compressor is higher than allowable level, compressor will stop and only when temperature recovers, compressor will restart.
Discharge high temperature protection
Once the discharge temperature of the compressor is higher than allowable value, compressor will stop and the unit will display a malfunction code.
Temperature sensor alarm
Once temperature sensor is o or short-circuited, system will indicate the error code and give an alarm.
5
Good Versatility
For more details visit www.mrcool.com
Easy Installation
The indoor unit can be installed with either horizontal or vertical furnace so as to meet various installation requirements.
Flexible Electronic Expansion Valve
The electronic expansion valve guarantees that the system makes adjustments automatically according to the changes of the circumstances and water temperature. It is more energy saving and stable than capillary.
Compact Design & Easy Maintance
The newly designed 4-sided detachable case is capable of not only accommodating the large-sized electric box, but also keeping a compact structure. The compact design of the indoor and outdoor unit helps to reduce the installation space and transportation cost. The fan system is dismountable to simplify the maintenance.
Intelligent Control
For more details visit www.mrcool.com
Precise Temperature Control
Both wired thermostats and outdoor units are furnished with a temperature sensor, which can precisely detect the outdoor and indoor temperature. The compressor can then adjust the power input based on the change of the indoor and outdoor temperature, as to supply more even airflow, which provides the occupants a more comfortable setting.
Indoor Unit Separate Control
Indoor units are separately controlled through the wired thermostat. Even though the unit is turned o, FAN mode can still be the realized through the Fan button on the wired controller.
Memory Function (optional)
Two statuses of “Memory On” and “Memory O” can be configured for the thermostat. This function can save the repeated setting owing to any power failure.
When the controller is set to “Memory On”, the controller can memorize the running status before the power failure and resume the previous running status after the power restoration.
When the controller is set to “Memory O”, the running air conditioner will go to the standby status in the event of power failure.
Other Functions
ON/OFF timer function | Switch between °C and °F | Filter-wash awake | Thermostat button lock
7
Intelligent Control
For more details visit www.mrcool.com
Outdoor Unit
MODEL COOLING ONLY MAC18024 MAC18036 MAC18042 MAC18048
Capacity Cooling BTU/h 24000/20000 35000/31000 41000/35000 48000/46000
Power supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Refrigerent charge volume kg 1.8 2.55 2.9 3.5
Power input Cooling kW 1.96 2.98 3.57 3.85
Rated current Cooling A 13 18 21 25
Air flow volume
Sound pressure level db(A) 57 62 63 63
Dimension (WxDxH)
Net weight / Gross weight lbs 114.6/123.4 156.5/165.3 169.7/182.9 211.6/242.5
Connection pipe diameter
Loading quantity 40’GP/40’HQ set 162/216 135/135 90/135 90/90
Outline inch 24×24× 24.4 27.9×27.9×28.9 27.9×27.9×33.4 29.5x29.5x33.4
Package inch 25.6×25.6×25.7 30.4×30.4×29.7 30.4x30.4x34.8 30.4x30.4x39.5
Liquid inch(mm) φ3/8(9.52) φ3/8(9.52) φ3/8(9.52) φ1/2(12.7)
Gas inch(mm) φ5/8(15.9) φ3/4(19.05) φ7/8(22.2) φ7/8(22.2)
CFM 1764 2650 3000 3275
3
/h 3000 4500 5400 5567.5
m
Air Handler
MODEL MAH18024 MAH18036 MAH18042 MAH18048
Capacity BTU/h 24000 35000 41000 48000
Power supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Motor type - AC DC DC DC
Power input kW 0.1 3 0.32 0.238 0.238
Rated current A 0.52 3.6 4.6 4.6
Air flow volume
E×ternal statics pressure Pa 25 37 37 50
Sound pressure level db(A) 44 52 52 52
Dimension (WxDxH)
Net weight / Gross weight lbs 125.6/134.4 138.8/152.1 163.1/178.5 163.1/178.5
Connection pipe diameter
Loading quantity 40’GP/40’HQ set 154/160 112/152 81/108 81/108
Outline inch 20.9x21.2x43.5 20.9x21.2x48.1 24.4x21.2x48.1 24.4x21.2x48.1
Package inch 22.5x23.2x45.6 22.5x23.8x50.3 25.8x24.4x50.3 25.8x24.4x50.3
Liquid inch(mm) φ3/8(9.52) φ3/8(9.52) φ3/8(9.52) φ1/2(12.7)
Gas inch(mm) φ5/8(15.9) φ3/4(19.05) φ7/8(22.2) φ7/8(22.2)
CFM 706 1150 1300 14 20
3
/h 1200 1954 2209 2400
m
Electric Heat Kits Available
NO. KIT DESCRIPTION REF. AIR HANDLER USE
1 HNRd5 / A-D 5kw Heat Strip 18, 24, 30, 36, 42
2 HNRd8 / A-D 8kw Heat Strip 18, 24, 30, 36, 42
3 HNRd10 / A-D 10kw Heat Strip 18, 24, 30, 36, 42
4 HNRd5 -D Circuit Breaker, 5kw Heat Strip 18, 24, 30, 36, 42, 48
5 HNRd8 -D Circuit Breaker, 8kw Heat Strip 18, 24, 30, 36, 42, 48
6 HNRd10 -D Circuit Breaker, 10kw Heat Strip 18, 24, 30, 36, 42, 48
7 HNRd15 -D Circuit Breaker, 15kw Heat Strip 30, 36, 42, 48
8 HNRd20 -D Circuit Breaker, 20kw Heat Strip 36, 42, 48