Mrcool MAC16XA User Manual

The Signature Series is NOT designed for amateur installation. Installation SHOULD be performed by an authorized technician.
Please read this manual carefully before installation and keep it for future reference.
Installation Manual
Signature Series
MAC16*A A/C SPLIT SYSTEM
The Signature Series is NOT designed for amateur installation. Installation SHOULD be performed by an authorized technician.
Please read this manual carefully before installation and keep it for future reference.
INSTALLATION INSTRUCTIONS
MAC16*A A/C SPLIT SYSTEM
This manual must be left with the homeowner for future reference.
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals, be alert to the potential for personal injury or death.
Table of Contents
Safety Precautions ......................................................2
Installation ...................................................................2
Electrical Connections.................................................4
Start-Up Procedure......................................................5
System Operation........................................................6
Homeowner’s Information ...........................................9
WARNING
result in hazards to you and others. Installation MUST conform with local building codes and with the National Electric Code NFPA 70/ANSI C1-1993 or current edition and Canadian Electrical Code Part 1 CSA .
NOTE
These instructions are intended as a general guide and do not supersede national, state or local codes in any way.
These instructions must be left with the property owner.
NOTE TO INSTALLING DEALER
These instructions and warranty are to be given to the owner or prominently displayed near the indoor air handler unit.
Manufactured By
MRCOOL, LLC
Hickory, KY 42051
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a licensed professional installer (or equivalent), service agency or the gas supplier.
*P507043-04C*
Save these instructions for future reference
507043-04C Page 1 of 9mrcool.com
These units are designed for use in residential and commercial type buildings. Units should be installed with combinations listed in the Air-Conditioning, Heating
5. When passing refrigerant tubes through the wall, seal opening with RTV or other silicon-based caulk.
6. Avoid direct tubing contact with water pipes, duct work,
Products. Refer to http://www.ahridirectory.org.
Before installation, inspect the unit for shipping damage. If damage is found, notify the transportation company
WARNING
Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label. Electrical shock can cause personal injury or death.
Safety Precautions
Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations.
thoroughly and follow all warning or cautions attached to the unit.
1. Always wear proper personal protection equipment.
2. Always disconnect electrical power before removing panel or servicing equipment.
3. Keep hands and clothing away from moving parts.
4. Handle refrigerant with caution, refer to proper MSDS from refrigerant supplier.
5. Use care when lifting, avoid contact with sharp edges.
Installation
Unit Location
NOTE: In some cases noise in the living area has been
traced to gas pulsations from improper installation of equipment.
1. Locate unit away from windows, patios, decks, etc. where unit operation sounds may disturb customer.
2. Ensure that vapor and liquid tube diameters are appropriate to capacity of unit.
3. unecessary turns and bends.
4. Leave some slack between structure and unit to absorb vibration.
7. Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with tubing.
8. Ensure that tubing insulation is pliable and completely surrounds suction line.
When outdoor unit is connected to factory-approved indoor unit, outdoor unit contains system refrigerant charge for operation with indoor unit of the same size when connected
check refrigerant charge using charging information located on control box cover.
NOTE: Maximum liquid-line size is 3/8 in. O.D. for all residental applications including long lines.
Outdoor Section
Zoning ordinances may govern the minimum distance the condensing unit can be installed from the property line.
Install on a Solid, Level Mounting Pad
The outdoor section is to be installed on a solid foundation. This foundation should extend a minimum of 2” (inches) beyond the sides of the outdoor section. To reduce the possibility of noise transmission, the foundation slab should NOT be in contact with or be an integral part of the building foundation.
If conditions or local codes require the unit be attached to pad or mounting frame, tie down bolts should be used and fastened through knockouts provided in unit base pan.
Rooftop Installations
Mount on level platform or frame 6 inches above roof surface. Place unit above a load-bearing wall and isolate unit and tubing set from structure. Arrange supporting members to adequately support unit and minimize transmission of vibration to building. Ensure roof structure and anchoring method is adequate for location. Consult local codes governing rooftop applications.
NOTE: Unit must be level to within ± 1/4 in./ft per
Clearance Requirements
snow, or ice from roof or eaves cannot fall directly on unit.
Page 2 of 9 507043-04Cmrcool.com
Figure 1. Clearance Requirements
Do Locate the Unit:
With proper clearances on sides and top of unit (a minimum of 12” on the three sides, service side should be 24” and 48” on top
On solid, level foundation or pad
To minimize refrigerant line lengths
Do not leave the lines open to the atmosphere for any period of time, moisture, dirt and bugs may contaminate the lines.
Filter Drier
and reliability. If the drier is shipped loose, it must be
void, if the drier is not installed.
13/16 SEER
Model
Liquid Line Suction Line
18 3/8 3/4
24 3/8 3/4
30 3/8 3/4
36 3/8 7/8
42 3/8 7/8
48 3/8 7/8
60 3/8 1-1/8
* Fittings should be supplied by the installer.
Do Not Locate the Unit:
On brick, concrete blocks or unstable surfaces
Near clothes dryer exhaust vents
Near sleeping area or near windows
Under eaves where water, snow or ice can fall directly on the unit
With clearance less than 2 ft. from a second uni
With clearance less than 4 ft. on top of unit
Indoor Coil Piston Selection
The outdoor section must be matched to a factory approved indoor section. It is mandatory that the installer ensure that the correct piston or TXV is installed in the indoor section. If necessary remove the existing piston and replace it with the correct piston or TXV. See indoor unit instructions for details of changing the piston or TXV. Contact your distributor for accessory piston kits.
The correct piston size is shipped with the outdoor unit,
piston that comes with the indoor unit, unless it matches the one listed on the outdoor unit.
Table 1.
Installation of Line Sets
DO NOT fasten liquid or suction lines in direct contact with
type of hanger. Keep both lines separate, and always insulate the suction line. Long liquid line runs (30 feet or more) in an attic will require insulation. Route refrigeration line sets to minimize length.
DO NOT let refrigerant lines come in direct contact with foundation. When running refrigerant lines through the foundation or wall, openings should allow for a sound and vibration absorbing material to be placed or installed between tubing and foundation. Any gap between
with a vibration damping material.
Refrigeration Line Sets
Use only refrigeration grade copper tubes. Split systems may be installed with up to 50 feet of line set (no more than 20 feet vertical) without special consideration. For lines 50 feet or longer, refer to long line set guidelines.