Incorrect installation may cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.
This symbol indicates ignoring instructions may cause death or serious injury.
WARNING
This symbol indicates that ignoring instructions may cause moderate injury to
your person, damage to your unit, or other property.
CAUTION
This symbol indicates that you should never perform the indicated action.
WARNING
Do not modify the length of the power supply cord or use an extension cord to power the unit.
Do not share the electrical outlet with other appliances. Improper or insufficient power supply
can cause fire or electrical shock.
When connecting refrigerant piping, do not let substances or gases other than the refrigerant
enter the unit. The presence of other gases or substances will lower the unit’s capacity, and may
cause abnormally high pressure in the operation cycle. This may cause explosion and injury.
Do not allow children to play with the air conditioner. Children should be supervised around
the unit at all times.
1. Installation must be performed by an authorized technician. Improper installation may cause water
leakage, electrical shock, or fire.
2. Installation must be performed according to installation instructions. Improper installation may
cause water leakage, electrical shock, or fire.
(In North America, installation must be performed in accordance with the requirement of NEC and
CEC by authorized personnel only.)
Contact an authorized service technician for repair or maintenance of the unit.
3.
Only use the included accessories and specified parts for installation. Using non-standard
4.
parts can cause water leakage, elctrical shock, or fire and may cause the unit to fail.
5.
Install the unit in a firm location that can support the unit’s weight. If the installation location
cannot support the weight, or the installation is performed improperly, the unit may fall and cause
serious injury and/or damage.
Page 3
Safety Precautions
WARNING
For all electrical work, follow all appropriate wiring standards, regulations, and the Installation
6.
Manual. You must use an independent circuit and single outlet to supply power. Do not connect
other appliances to the same outlet. Insuficient electrical capacity or defects in electrical work can
cause electrical shock or fire.
7.
For all electrical work, fuse the specified cables. Connect cables tightly, and clamp them securely
to prevent external forces from damaging the terminal. Improper electrical connections may
overheat, causing fire and/or electrical shock.
8.
All wiring must be properly arranged to ensure that the control board cover can close properly. If
the control board cover is not closed properly, it can lead to corosion and cause the connection
points on the terminal to overheat , causing fire and/or electrical shock.
In certain functional environments, such as kitchens, server rooms, etc., the use of specially
9.
designed air-conditioning units is highly recommended.
10.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard
11.
This appliance can be used by children aged from 8 years and above and persons with reduced
Physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children should not play with the appliance. Cleaning and user
maintenance should not be made by children without supervision.
CAUTION
For units that have an auxiliary electric heater, do not install the unit within 3 feet (1 meter)
of combustible materials.
Do not install the unit in a location that may be exposed to combustible gases. If combustible
gas accumulates around the unit, it may cause fire.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Too
much exposure to water may cause electrical components to short circuit.
1. The product must be properly grounded during installation, or electrical shock may occur.
2. Install drainage piping according to the instructions in this manual. Improper drainage may
cause water damage to your home and property.
Note about Flourinated Gasses
1. This air-conditioning unit contains flourinated gases. For specific information on the type of gas
and the amount, please refer to the relevant label on the unit itself.
2. Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
Product uninstallation and recycling must be performed by a certified technician.
3.
4. If the system has a leak-detection system installed, it should be checked for leaks at least every
12 months.
5. Keep a record of all leak checks for the lifetime of the unit.
Page 4
Accessories
1
The air conditioning system includes the following accessories. Use all of the installation parts and
accessories to install the air conditioner. Improper installation may result in water leakage, electrical
shock, fire, or equipment failure.
Name
Mounting plate
Clip anchor
Mounting plate fixing
screw ST3.9 X 25
Remote control
Fixing screw for remote
controller holder ST2.9 x 10
ShapeQuantity
1
5
5
1
2
Optional
Parts
Remote control holder
Dry battery AAA.LR03
Air freshening filter
Seal
Drain joint
Page 5
1
2
1
1
(for cooling & heating
models only)
Accessories
Name
Owner’s Manual
Installation Manual
Remote Control Manual
INVERTER SPLIT-TYPE ROOMAIR CONDITIONER
Owner’s Manual
All Model Numbers
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
INVERTER SPLIT-TYPE ROOMAIR CONDITIONER
Installation Manual
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
INVERTER SPLIT-TYPE ROOMAIR CONDITIONER
Remote controller
illustration
ShapeQuantity
1
CS78421-548-754
1
CS78421-548-754
1
Connecting pipe assembly
Smart Controller Kit
Neoprene
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
Liquid side
Gas side
CS78421-548-754
6.35( 1/4i n)
9.52( 3/8in)
9.52( 3/8in)
12.7( 1/2in)
16( 5/8in)
Parts you must purchase.
Consult the dealer about
the pipe size.
1
(w/ Manual in Controller Box)
1
(Sealant for Wall Sleeve)
Page 6
Installation Summary - Indoor Unit
2
12
>12cm
(4.75in)
Minimum Ceiling
Clearance is
15cm (5.9in)
>12cm
(4.75in)
For Ceilings Greater
Than 9 Foot Suggested
Floor Clearance is
230cm(90.55in)
For Ceilings Less
Than 9 Foot Suggested
Floor Clearance is
200cm(78.55in)
Select Installation Location
(Page 10)
Determine Wall Hole Position
(Page 11)
3
Attach Mounting Plate
(Page 11)
4
Drill Wall Hole
(Page 11)
Page 7
Installation Summary - Indoor Unit
567
LNS
8
Connect Piping
(Page 24)
Connect Wiring
(Page 16)
Wrap Piping and Cable
(Page 17)
Prepare Drain Hose
(Page 13)
9
STEP
Mount Indoor Unit
8
(Page 17)
Page 8
Parts
3
Wall Mounting Plate
Louver
Front Panel
Functional Filter
Power Cable
Drainage Pipe
Signal Cable
Refrigerant Piping
Remote Control
NOTE ON ILLUSTRATIONS
Illustrations in this manual for explanatory purposes. The actual shape of your indoor unit may vary.
Page 9
Remote Holder
Outdoor Unit
Power Cable
( Units)
Fig. 2.1
Indoor Unit Installation
4
Installation Instructions – Indoor
Unit
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the
label on the product box to make sure that the
model number of the indoor unit matches the
model number of the outdoor unit.
Step 1: Select installation location
Before installing the indoor unit, you must
choose an appropriate location. The following
are standards will help you choose an
appropriate location.
Proper installation locations meet the
following standards:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other
people
Firm and solid—the location will not vibrate
DO NOT install unit in the following locations:
Near any source of heat, steam, or
combustible gas
Near flammable items such as curtains or
clothing
Near any obstacle that might block air
circulation
Near a doorway
In a location subject to direct sunlight
NOTE ABOUT WALL HOLE:
If there is no fixed refrigerant piping:
While choosing a location, be aware that you
should leave ample room for a wall hole (see
Drill wall hole for connective piping step)
for the signal cable and refrigerant piping that
connect the indoor and outdoor units. The
default position for all piping is the right side
of the indoor unit (while facing the unit).
However, the unit can accommodate piping
to left or right.
Strong enough to support the weight of the
unit
A location at least one meter from all other
electrical devices (e.g., TV, radio, computer)
Page 10