Thank you for purchasing MRC’s Super Brain 959. The 959 LCD charger of fers cutting edge technology, packed with many advanced features. We hope you enjoy using your new 959!
FEA TURES
AC/DC Delta Peak charger with MicroPeak Technology
LCD displays five readings: Battery Status, Battery Voltage (V), Charge Current (A),
Charging T ime in minutes (Min), and Delta Peak Voltage Threshold in millivolts (mV)
Charges Nickel Cadmium and Nickel Metal Hydride batteries
For 3~8 cell AA and sub-C packs, plus a special setting for single cell “Glow Driver”
battery (single-cell)
Nine charge current rates:
0.5Amp to 4.5Amp with 0.5Amp increments
Fourteen delta peak voltage thresholds:
5mV to 70mV with 5mV increments
Plug ‘n Play Operation for sub-C or larger battery cell(s)
12-bit Analog to Digital Converter greatly improves measurement resolution
Digital Signal Processing (DSP) filters out noise and provides greater measurement
accuracy
Compact size to fit into a field box
PLUG N’ PLAY INSTRUCTIONS for sub-C or larger battery cell(s)
1. Connect the charger to a power source (120V AC or 12V DC).
2. Attach the battery to the charger. The battery’s voltage will appear on the screen.
3. The charger has a default charge rate of 3.0 Amps. Press the start button to begin charging if this is the intended setting. See ADVANCED INSTRUCTIONS section to change the charge current rate.
4. The first 30~60 seconds is the battery diagnostic period. LCD will display “test” and the red light will flash during this period. The unit will not accept new commands during this diagnostic period.
5. LCD will display “Charge” and the red light will remain on during fast charge. The battery status and voltage are displayed.
6. The charge rate, time and voltage can be viewed by pressing the “Display” button.
NOTE: If the delta peak voltage threshold has not been set manually, ignore the display for the delta peak voltage threshold. The value displayed is irrelevant.
7. Charging can be stopped at any time during the charge cycle by pressing the “Start” button.
8. When the fast charge cycle is complete, the unit will beep three times and automatically begin a 50-minute 0.1 Amp trickle char ge cycle. During the trickle charge cycle “Charge” and the red light will blink (with very short on time and long off time). After the trickle cycle, the charger will automatically go into sleep mode.
9. Under normal ambient conditions, this charger stays cool and can continue to charge 3 to 4 batteries consecutively . After several consecutive charges, the protection circuit may activate to prevent the unit being damaged. When this happens, please disconnect the charger from the power source and allow the charger to cool down.
10. The LCD screen will become unclear if the unit is excessively hot. Please stop using the charger if the LCD screen becomes unclear and allow the unit to cool.
11. “Err” displayed at any time indicates an error has occurred.
Example: If the charger is not corr ectly connected, “Err” message may appear.