1.Features: * You can MRC meter with RS232 output interface connected to the RSW-914, to transfer data
via WiFi to the desired device. However, the use of smart phones or tablet computers
developed by the company's free software to do data collection record APP.
* WiFi work mode: Access Point(AP) mode * I/O terminal:
1.DC 9V power input
2.DC 9V power output(power supply for the connecting RS232 meter)
3.One RS232 input(photo isolate RS232 type)
* Maximum TCP connections to 20
2/5
2.SPECIFICATIONS
Circuit
Custom single-chip microprocessor LSI circuit
Display
LCD Size: 3.2 X 2.4" (60 X 44.4 mm) Dot Matrix backlit LCD (128 X 64 pixels)
Wireless * Support IEEE 802.11b / g / n wireless standards.
* Support the range of frequency : 2.412 to 2.484 GHz. * Support wireless networks: Access Point(AP)
Input signal One isolated RS232 signal input
Wireless mode setting
* Access Point (AP) Mode
Operating temperature
0 to 50℃ ( 32 to 122℉ ).
Operating humidity
Less than 80% R.H..
Power supply AC to DC adapter 9V.
Power consumption
DC 200 mA approximately.
Weight 170 g/0.375 LB.
Dimension 134 X 80 X 32 (5.3 X 3.1 X 1.3 inch).
* Dimension is for the meter without antenna only.
Accessories included
* Instruction manual..........................................1PC
* Data interface cable, UPCB-03...............................1PC
* Power interface cable, PWCB-06..............................1PC
* Hanging unit ( with sticker )...............................1PC
* AC to DC 9V power adapter...................................1PC
Optional Accessories
* Full line MRC RS232 meters.
3/5
3.FRONT PANEL DESCRIPTION
Fig.1
3-1 DC 9V Power adapter input socket 3-2 DC 9V output socket 3-3 Isolate input socket 3-4 Antenna and antenna socket 3-5 Power indicator 3-6 WiFi link indicator 3-7 RS232 signal indicator 3-8 System reset button 3-9 Stand 3-10 Hanging holes 3-11 Hanging unit ( with sticker ) 3-12 Power interface cable/plugs
4/5
4.MEASURING PROCEDURE 4-1.AP Mode:
1.First, install MRC dedicated APP software
1-1.The use of smart phones in the APP Store download MRC OneMeterApp software
(SCREEN4-1-1) or on the MRC official website OneMeterApp software (SCREEN4-1-2)
1-2.After the download is complete, install it.
SCREEN4-1-1 SCREEN4-1-2 SCREEN4-1-3
2.The RSW-914 boot, you can make a connection after about 30 seconds
2-1.WiFi connectivity indicators
2-1-1.Power & LINK & RX indicator will also light within 5 seconds 2-1-2.LINK & RX indicator, synchronous flashes for about 25 seconds later,when
there is no rule of LINK indicator turns blinking, you can connect.
2-2.Start Smart Phone WiFi, make RSW-923 connection (SCREEN4-1-3). 2-3.Open OneMeterApp software (such as SCREEN4-1-4)
2-3-1.In SCREEN4-1-4 select Step1 (Meter1) 2-3-2.Is displayed SCREEN4-1-5, select Step2 tool button then into the SCREEN4-1-6 2-3-3.Enter the relevant information in SCREEN4-1-6
1) Meter name: Meter1 name can be changed to the desired user name
2) CH NO.: In accordance Meter CH NO. To enter
3) Sampling time: minutes as a reference, check after do Logger function (must
be set)
4) Save file: Select the Logger path to be stored (must be set)
5)Alarm Beeper: After checking the SCREEN4-1-6 to tie the set, when they meet
the conditions have an effect
6)Alarm SMS: After checking the SCREEN4-1-6 to tie the set, when meet the
conditions will send SMS
2-3-4.In SCREEN4-1-7 the Save tool button, the value will be set according to Save
the storage, and it will return to SCREEN4-1-5 screen when Step3 green and
flashing that means the RSW-914 connection
2-3-5. In SCREEN4-1-5 of Step4 (CH1) click on the picture into the SCREEN4-1-7, then
do High and Low Set and checked, when you press the Return smartphone screen will return to SCREEN4-8-5 When the measured value have reached the condition CH1-CH3 will show red numbers and have Beeper and send SMS.
2-3-6.Re-connect: When they find breaking news WiFi is not connected, you can press
the function do reconnect action.
2-3-7.Auto Log: Sampling time is set based on the time and checked, do the automatic
recording function (such as SCREEN4-1-6).
2-3-8.Manaul Log: Each time you press the tool button, then record sum.
* Both formats Auto Log or Manaul Log, archival records are xml
2-3-9.View Log: See the recorded data directly on smart phones (such as SCREEN4-1-8)
5/5
SCREEN4-1-4 SCREEN4-1-5 SCREEN4-1-6
SCREEN4-1-7 SCREEN4-1-8
Loading...