provides operation at 68 dB(A) at 23 feet. Fully lockable
enclosure allows safe unattended operation.
Internal fuel tank
standard.
Seven stage powder coat paint
weather protection.
reduces service and maintenance
provides virtually unlimited
of standby nameplate rating in one
with direct reading fuel gauges are
provides maximum
(AVR) provides precise
maintains frequency to
provides durability and
Complete engine analog instrumentation
Complete generator analog instrumentation
Automatic safety shutdown system
Auto start/stop control
Complete power panel.
Fuel/water separator
EPA emissions cer tified
includes DC
ammeter, oil pressure gauge, water temp. gauge, fuel level
gauge, tachometer/hour meter, manual engine speed
control, and emergency shutdown monitors.
includes
voltage regulator control, ammeter phase selector switch,
voltmeter phase selector switch, AC voltmeter, AC
ammeter, frequency meter, panel light, and circuit breaker.
monitors the water
temperature, engine oil pressure, overspeed, and
overcrank. Warning lights indicate abnormal conditions.
allows generator to start
automatically in the event of a commercial power failure.
Fully covered; three-phase
terminals and single phase receptacles allow fast and
convenient hookup for most applications including
temporary power boxes, tools and lighting equipment. All
are NEMA standard.
removes condensation from fuel
for extended engine life.
- Tier 3 emissions compliant.
DCA150SSJ Rev 5
Page 2
Specifications
C
G
F
E
DCA150SSJ
WhisperWattTM Generator
enerator Specifications
Design
No. of Poles4-pole
ExcitationBrushless with AVR
Standby Output132 kW (165 kVA)
Prime Output120 kW (150 kVA)
Generator RPM1800
Voltage — 3Ø208, 220, 240, 416, 440, 480V Switchable
Voltage — 1Ø120, 127, 139, 240, 254, 277V Switchable
Displacement6800 cc
No. cylinders6
Bore x Stroke106 x 127 mm
Gross Engine Power Output197 hp (146 kW)
BMEP229 psi (1578 kPa)
Piston Speed1500 ft/min (8.62 m/s)
Compression Ratio17.0:1
Engine Speed1800 rpm
Overspeed Limit2100 rpm
Oil capacity8.19 gal (31 L)
Battery12V 128 Ah x 1
4-cycle, watercooled, direct injection,
turbocharged, air to air intercooled
ooling System
Fan Load4.0 hp (3.0 kW)
Coolant Capacity (with radiator)4.6 gal (17.5 L)
Coolant Flow Rate (per minute)48 gal (180 L)
Heat Rejection to Coolant (per minute)5324 Btu (5.62 MJ)
Heat Rejection from Engine (per minute)1821 Btu (1.92 MJ)
Maximum Coolant Friction Head2 psi (13.8 kPa)
Maximum Coolant Static Head21 ft (6.4m)
Ambient Temperature Rating104°F (40°C)
Air
Combustion Air452 cfm (12.8 m3/min)
Maximum Air Cleaner Restriction25.0 in. H
Alternator Cooling Air 1352 cfm (38.3 m
Radiator Cooling Air4237 cfm (120 m
O (6.25 kPa)
2
3
/min)
3
/min)
xhaust System
Gas Flow (full load)1165 cfm (33 m3/min)
Gas Temperature916°F (560°C)
Maximum Back Pressure 30 in H
12 months from date of purchase and unlimited hours or 24 months
from date of purchase with 2000 hours (whichever ocurs first).
*Refer to the express written, Engine warranty sheet for additional coverage
information.
Generator
24 months from date of purchase or 2000 hours (whichever occurs
uel System
Recommended FuelASTM-D975-No.1 and No. 2-D
Maximum Fuel Flow (per hour)28.4 gal (108 L)
Maximum Inlet Restriction (Hg)5.9 in (150 mm)
Fuel Tank Capacity69 gal (260 L)
*Refer to the express written, one-year limited warranty sheet for additional
information.
T railer
12 months excluding normal wear items.
Generator is not intended for use in enclosed areas or where free flow of air is restricted.
Backfeed to a utility system can cause electrocution and/or property damage. Do not
connect to any building’s electrical system except through an approved device.
Specifications are subject to change without notice.
Page 3
DCA150SSJ
WhisperWattTM Generator
Optional Generator Features
Generator Output Panel
Battery charger —
adjusting charging to the generator's battery system.
Jacket water heater —
weather climates.
Special batteries —
engine cranking power.
Spring isolaters —
for standby applications.
T railer mounted package —
electronic or surge brakes with single or double axle
configuration. Extra capacity fuel tanks are also
available.
provides fully automatic and self-
for easy starting in cold
long life batteries provide extra
provides extra vibration protection
highway legal trailer with
Optional Control Features
Audible alarm
Low coolant level shutdown system
protection from critically low coolant levels. Includes
control panel warning light.
Emergency stop switch
alerts operator of abnormal conditions.
provides
Optional Fuel Cell Features
Trailer fuel tank —
trailer allows for extended run time.
Sub-base fuel cells (double wall) —
cell for extended runtime operation. Contains a leak
sensor, low fuel level switch, and a secondary
containment tank. UL142 listed.