MPP Solar PIM-1012 24C Instruction Manual

IF THE TOTAL WATTS OF ELECTRICAL APPLIANCES EXCEEDS
THE OUTPUT CAPACITY OF INVERTER. OR AFTER OPERATING
FOR A PERIOD OF TIME. IF THE TEMPERATURE OF THE INVERTER REACHES 60 ℃℃℃ , THE INVERTER SHALL BE
0000
60 C
.
CAUTION
* ALWAYS PLACE THE INVERTER IN
AN ENVIRONMENT WHICH IS :
( A ) WELL VENTILATED
( B ) NOT EXPOSED TO DIRECT
SUNLIGHT OR HEAT SOURCE
( C ) OUT OF REACH FROM CHILDREN
( D ) AWAY FROM WATER/MOISTURE,
OIL OR GREASE
( E ) AWAY FROM ANY FLAMMABLE
SUBSTANCE
※※※※
WARNING
※※※※
FLUORESCENT LAMP
DO NOT USE THIS DEVICE WITH FLUORESCENT LAMPS.
BALLASTS
Glow switch
Lamp
AC IN
Power Factor Capacitor
a
b
8
FULL AUTOMATIC DC-AC 1000W
INVERTER & BATTERY CHARGER
DC12V or 24V to AC220V~240V Instruction Manual
Please read user manual before use.
1
USEFUL APPLICATIONS
RUN NOTEBOOK COMPUTERS, RADIOS, TVS, VCRS,
LAMPS, FANS, FAX, DRILL, . . . . . . ETC.
SPECIFICATION
INPUT VOLTAGE RANGE : DC 10~15V (12V) // DC 20~30V (24V) INPUT FULL LOAD CURRENT : 100A (12V) // 50A (24V) STANDBY INPUT CURRENT : <0.4A (12V) // <0.3A (24V) OUTPUT VOLTAGE (AC) : 220V~240V OUTPUT WAVEFORM : MODIFY SINEWAVE OUTPUT FREQUENCY : 50Hz or 60Hz CONTINUE OUTPUT POWER : 1000W PEAK OUTPUT POWER : 2400W
EFFICIENCY : 85~90% BATTERY LOW PRE-ALARM : 10.5 ± 0.5V (12V) // 21 ± 0.5V (24V) BATTERY LOW SHUTDOWN : 10 ± 0.5V (12V) // 20 ± 0.5V (24V) THERMAL PROTECT : 60 ± 5℃℃℃(MICROCONTROLLER )
AUTO-OPERATION FAN (TEMPERATURE OR LOAD) OVERLOAD PROTECT : YES (MICROCONTROLLER ) OUTPUT SHORT PROTECT : YES ( MICROCONTROLLER ) BATTERY EX. 12V / 24V PROTECT : YES ( MICROCONTROLLER ) BATTERY POLARITY PROTECT : YES (BY FUSE ) FUSE : 25A*6PCS (12V) // 15A*6PCS (24V) TRANSFER TIME : 16m SEC
CHARGER CURRENT : MAX. 10A (12V) // 5A (24V)
DIMENTION ( L*W*H) mm : 360*198*80
WEIGHT : 3.8Kg
2
BATTERY LED DARK/LIGHT INDICATIVE CHART.
12V 13.5V
A
14.5V13V12.5V
BATTERY
LED
LIGHT
BATTERY
LED
BLINKS
BATTERY
LED
LIGHT
BATTERY
LED
LIGHT
14V
:CHARGER CURRENT
(24V)
0A
5A
4A
3A
2A
1A
7A
6A
8A
10A
9A
0A
2.5A
2A
1.5A
1A
0.5A
3.5A
3A
4A
5A
4.5A
(24V)
(28V)(27V)(26V)(25V) (29V)
V
0.4(24V)
V
0.2(12V)
INDICATING SIGN
NORMAL LIGHTED LED : POWER SWITCH “ ON ” , INVERTER STANDBY
NORMAL UNLIGHTED LED : POWER SWITCH “ OFF ”
CHARGER LIGHTED LED : BATTERY CHARGING
CHARGER LED BLINKS : FULL BATTERY
NORMAL
ON
CHARGER
ON
OFF
OVERLOADOVERTEMP
NORMAL
CHARGER
AC OUTPUT
AC
OUTLET
7