moyno A4015A, A4050A, A4190A, A2400A, A4100A Service Manual

...
Max. Pressure 300 PSI, 20 bar
Section:
METERING/DOSING PUMP
Page: 1 of 5 Date: July 2009
SERVICE MANUAL
BARE SHAFT
A4015A, A4050A, A4100A, AND A4190A, A2400A, and A4400A MODELS
DESIGN FEATURES
Suction Housing: Stainless steel Bearing Housing: Cast iron Pump Rotor: Chrome plated, 300 series stainless steel Pump Stator: Nitrile, EPDM, Fluoroelastomer Shaft: 300 series stainless steel Bearings: Prelubricated, fully sealed ball bearings Seal: Single or double mechanical seals, packing Flexible Joint: Prelubricated and sealed
INSTALLATION
Mounting. Provide the proper alignment between the pump
and drive by mounting both to a common flat base. Pump may be mounted in any position. When mounting vertically, it is necessary to keep bearings above seals to prevent possible seal leakage into bearings. Loosen screws on body support and stator support to rotate pump to desired position.
Pre-Wetting. Prior to connecting pump, wet pump elements and mechanical seal or packing by adding fluid to be pumped into suction port. Turn shaft over several times in a clockwise direction when viewed from the shaft end to work fluid into pump elements.
Piping. Piping to pump should be self-supporting to avoid excessive strain on pump housings. The suction port is 1-1/2" NPT and the discharge port is 1-1/4" NPT. Use pipe “dope” or tape to facilitate disassembly and to provide seal.
Drive. On belt driven units, adjust belt tension to point of non­slip. Do not overtighten.
On direct drive units, coupling components should be aligned and spaced at least 1/16" apart.
– Pump rotation must be clockwise when facing shaft. –
Check direction of rotation before startup.
– Maximum speed is 1750 rpm.
OPERATION
Self-Priming. With wetted pumping elements, the mechanical
seal model pump is capable of 15 feet of suction lift when operating at 1750 rpm with pipe size equal to port size.
DO NOT RUN DRY. Unit depends on liquid pumped for lubrication. For proper lubrication, flow rate should be at least 10% of rated capacity.
Storage. Always drain pump for extended storage periods using pipe plug in suction housing.
Pressure Limits. See Table 1 for maximum discharge pressure of each model.
Table 1
Temperature Limits. Unit is capable for service at 10°F to
210°F with nitrile, and to 260°F with EPDM, and 350°F with fluoroelastomer. Note: an undersize rotor may be required for elevated temperature applications.
TROUBLESHOOTING
WARNING: Before making adjustments, disconnect power
Failure to Pump.
1. Belt or coupling slip: Adjust belt tension or tighten set screw on coupling.
2. Wrong rotation: Rotation must be clockwise when facing shaft.
3. Excessive suction lift, vacuum or obstruction in suction piping.
4. Flexible joint broken; possible excessive pressure: Replace joint, check pressure at discharge port.
Will Not Start.
1. Insufficient horsepower: Check motor starting torque for minimum model starting torque given on performance curves.
2. Low voltage: Check power supply.
Models
4015 4050 4100 4190 2400 4400
source and thoroughly bleed pressure from system. Failure to do so could result in electric shock or serious bodily harm.
Max. Pressure 300 PSI, 20 bar Max. Pressure 300 PSI, 20 bar Max. Pressure 300 PSI, 20 bar Max. Pressure 300 PSI, 20 bar Max. Pressure 175 PSI, 12 bar