Moyer Diebel MDHHB User Manual

MDHHB
High Temperature Door-type Extended Hood Warewashing Machine with Booster
MDHH Model is without Booster
MDHHB DOORTYPE
Project Item No. Quantity
STANDARD FEATURES
• ENERGY STAR® Qualified
• Automatic tank fill
• Built-in stainless steel electric booster or internally mounted (MDHHB only)
• Automatic drain valve
• Adjustable mode/time selector switch
• Door activated cycle start
• Electric tank heat (5.2 kW)
• Low-water tank heat protection
• 2-Hp drip-proof pump motor
• Stainless steel pump impeller
• Door safety switch
• Interchangeable upper and lower spray arms
• Stainless steel front and side panels
• Vented wash chamber design
• Detergent/chemical connection provisions
• Single point electrical connection (see chart)
• Vent fan control
SPECIFIER STATEMENT
Specified unit will be Moyer Diebel model MDHHB door-type high temperature extended hood warewasher with built-in booster. (MDHH model is without booster)
Features include 2 Hp motor, 5.2 kW electric tank heat, dual NSF approved as both dishwasher and potwasher, adjustable mode/ timer switch and interchangable stainless steel upper and lower wash and rinse arms.
1 year parts and labor warranty.
3765 Champion Blvd, Winston-Salem, NC 27105 Tel: 336/661-1992 Fax: 336/661-1979 800/228-8350
(1M) 12/10 Printed in U.S.A.
Moyer Diebel – USA
www.moyerdiebel.com
OPTIONS & ACCESSORIES
Electric: 70°F rise (built-in) (MDHHB only)
Sheet pan rack
Corner operation with 90° mounted controls
Water pressure regulating valve (mounted)
(MDHHB only)
Drain water tempering kit
MDHHB DOOR TYPE
25"
[635]
1
5-1/4" [133] Min.
20-1/8"
[511] Inside Tracks
2-7/8"
[73]
Front
5-1/4" [133] Min.
3-1/4" [83]
9-1/4" [235]
5" [127]
Control Cabinet
A A
12-1/2" [318]
8-7/8" [225]
132
High Temperature Door-type
Extended Hood Warewashing Machine with Booster
MDHH Model is without Booster
Details, Dimensions & Connections
92-1/2" [2302]
Door
Removal
27" [686]
86" [2184]
Doors
67-1/2" [715]
Mach.
Height
Clearance
Up
34" [864]
Load
Height
Length between table connections: 26” Volume crated: 46 cu. ft. Shipping weight crated: 400 lbs.
Dimensions shown in inches [and millimeters]
A A
8-7/8" [225]
12-1/2" [318]
Wash Pump 2 Hp
1-1/8"
[29]
Utilities
1 Electrical (See Box)
2 Hot Water
3/4” NPT 110°F-140°F hot water connection. Flow pressure 20-22 psi.
3 Drain
2” O.D. connection. Max. flow rate. 15 US gpm.
30"
[762]
1-1/2" [32] Roll
21-3/8"
[543]
7-1/4"
[184]
Typical Table Construction
For Electrical Heat MDHHB w/40°F Rise Booster
Elec.
Specs.
208/60/1 76 80 80
240/60/1 85 90 90
208/60/3 42 45 45
240/60/3 47 50 50
480/60/3 20 25 25
575/60/3 17 25 25
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
For Electrical Heat MDHH Electrical Power Requirments
Elec.
Specs.
208/60/1 40 50 50
240/60/1 43 50 50
208/60/3 22 25 25
240/60/3 23 25 25
480/60/3 10 15 15
575/60/3 8 15 15
For Electrical Heat MDHHB w/70°F Rise Booster
Elec.
Specs.
208/60/3 59 70 70
240/60/3 67 70 70
480/60/3 31 35 35
575/60/3 26 30 30
Rated Amps
Rated Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Minimum
Supply Ckt.
Conductor
Ampacity
132
Maximum
Overcurrent
Protective
Device
Maximum
Overcurrent
Protective
Device
Due to an ongoing value analysis program at Moyer Diebel, specifications contained in this catalog are subject to change without notice.
3765 Champion Blvd, Winston-Salem, NC 27105 • 336/661-1992 • Fax: 336/661-1979 • www.moyerdiebel.com ‘USGBC’ and related logo is a trademark owned by the U.S. Green Building Council and is used by permission.
Loading...
+ 2 hidden pages