The W321/341 embedded computers featu re 2 or 4 RS-232/422/485 serial ports, 1 Ethernet port, 4 DI/DO (W321 only), an embedded 802.11 b/g/n wireless LAN module, and an SD socket interface for storage expansion, making the W321/341 ideal for compact, wireless embedded applications.
2. Package Checklist
Please verify that the package contains the following items:
1 W321/341 embedded computer
Quick Installat ion Guide
Document & Software CD
Ethernet Cable: RJ45 to RJ45 cross-over cable, 100 cm
CBL-4PINDB9F-100: 4-pin header to DB9 female console port
cable, 100 cm
WLAN Antenna
Universal Power Adaptor
Product Warranty Statement
Optional Accesso ries
35 mm DIN rail Moun ting Kit (DK- 35A)
3. W321/341 Panel Layout
W341-LX
W321-LX
LED Indicators
The following t able describe s the LED indica tors located on the front panel of the W321/341.
LED Name
Color
LED Function
Ready
Green
Power is on and functioning normally
Off
Power is off or power failure
SD
Green
SD card detected
Off
No SD card detected
WLAN
Green
ON: WLAN is ready Blinking: WLAN IP conflict or DHCP server
not responding
Off
WLAN is not enabled or connection failure
Signal Strength (5 LEDs)
Green
Number of glowin g LEDs indica tes signal strength: 5: Excellent 4: Very good 3: Good 2: Fair
1: Bad
Off
No signal
LAN
Orange
10 Mbps Ethernet link
Green
100 Mbps Etherne t link
Off
Disconnected or short circuit
TxD (P1-P4)
Green
Serial port (1 -2 for W321, 1-4 for W341)
transmitting data
Off
Serial port(1- 2 for W321, 1-4 for W341) not transmitting data
RxD (P1-P4)
Yellow
Serial port (1 -2 for W321, 1-4 for W341)
receiving data
Off
Serial port (1-2 for W321, 1-4 for W341) not receiving data
If you find a weak wireless communication (where the signal strength indic ates “Bad”), we suggest you ins tall the W321/ 341 computers at some other place within a stronger wireless signal range, or boost the signal by installing another wireless access point or bridge.
4. Installing the W321/341
Wall or Cabinet Mounting
The W321 have bu ilt
-in “ears” for attaching the embedded
computers to a wall or the inside of a cabinet. We suggest using
two screws per ear to attach the W3
21/341 to a
wall or cabinet .
The
heads of the screws should be less than 6.0
mm in diameter, and the shafts should be less than 3.5 mm in diameter, as shown by the figure at the right.
The W341 comes with two metal attachment plates for attaching the embedded computer to a wall or the
inside of a cabine t. First,
use two screws per bracket to attach the brackets to the rear of the W341. Next, use two screws per bracket to attach the W341 to a wall or cabinet .
DIN Rail Mounting
DIN rail attachments can be purchased separately to attach the product to a DIN rail. When sna pping the clips onto the DIN rail, make sure that the stiff metal springs are at the top.
Wall or Mounting
DIN rail Mounting
5. Connector Description
Power Connector
Connect the 12 to 48 VDC LPS or Class 2 power line to the W321/341’s terminal block. If the power is properly supplied, the Power LED will l ight up. The OS is ready when the Ready LED glows a solid green.
– 4 – – 5 – – 6 –
www.moxa.com/support
The Americas:
+1-714-528-6777 (toll-free: 1-888-669-2872)
Europe:
+49-89-3 70 03 99-0
Asia-Pacific:
+886-2-8919-1230
China:
+86-21-5258-9955 (toll-free: 800-820-5036)
2013 Moxa Inc. All rig hts reserved.
Grounding the W321/341
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting the power.
ATTENTION
This product is intended to be mounted to a
well-
grounded
mounting surface such as a metal panel.
Shielded Ground:
The
shielded ground (or SG, sometimes called
p
rotected ground
) contact is the leftmost contact
of the 3
-pin power term inal block, when viewed
from the angle shown here. Connect the SG wire to an appropriate grounded metal surface.
Ethernet Ports
The 10/100 Mbps Ethernet port uses RJ45 connectors.
Pin
Signal
1
ETx+
2
ETx-
3
ERx+
6
ERx-
Serial Ports
The serial ports use DB 9 connectors. Each port can be configured by software for RS-232, RS-422, or RS-485. The pin assignments for the ports are shown in the following table:
Pin RS-232 RS-422
RS-485
(4-wire)
RS-485
(2-wire)
1
DCD
TxDA(-)
TxDA(-)
--- 2 RxD
TxDB(+)
TxDB(+)
---
3
TxD
RxDB(+)
RxDB(+)
DataB(+)
4
DTR
RxDA(-)
RxDA(-)
DataA(-)
5
GND
GND
GND
GND
6
DSR
---
---
---
7
RTS
---
---
--- 8 CTS
---
---
---
SD Slot
The W321/341 has an internal SD slot for storage expansion. The SD slot allows users to plug a Secure Digital (SD) memory card compliant with the SD 1.0 standard for up to 1 GB of additional memory space, or a Secure Digital High Capacity (SDHC) memory card compliant with the SD 2.0 standard for up to 16 GB of additional mem ory space. Use a screw driver to remove the SD slot cover to access the slot. The slot is located on the right panel of the W321/341. Plug the SD memory card directly into the socket, and then replace the SD slot cover. The SD card will be mounted at /mnt/sd. To remove the SD card from the slot, gently pu sh the
SD card further into the slot and then remove the pressure to allow the card to spring out. You may then remove the card.
DI/DO
The W321 comes with 4 digital input channels and 4 digital outp ut channels. The DI/DO connectors is an array of five pairs of p in headers located on the right side of the computer. See the following figures for pin assignments.
Console Port
The serial console port is a 4 pin header RS-232 port. It is des igned for serial console terminals, which are useful for viewing boot-up messages. Use the CBL-4PINDB9F-100 cable included w ith the product to connect a PC to the W321/341’s serial console port.
Reset
Press the Reset button and hold it in for at least 5 seconds to load the factory default configuration. After killing all running pr ocesses, the system will take several seconds to synchronize its software to factory defaults. After the default configuration has been reloaded, the system automatically reboots. The Ready LED will blin k on and off for the first 5 seconds, and then maintain a steady glow once the system has rebooted.
Real-time Clock
The W321/341’s real-time clock is powered by a lit hium batter y. We strongly recommend that you do not replace the lithium battery without help from a qualified Moxa support engineer. If you need to change the battery, contact the Moxa RMA service team.
ATTENTION
There is a risk of explosion if t he
lithium batter y is
replaced
with an incompat ible battery.
6. Powering on the W321/341
To power on the W321/341, install the terminal-block-to-power-jack converter on the W321/341’s DC terminal block (located on the left rear panel), and then connect the power adaptor . Note that the ground/earthing wire should connect to the rightmost pin of the terminal block. It takes about 30 seconds for the system to boot up. Once the system is fully booted the Ready LED will light up.
7. Connecting the W321/341 to a PC
There are two ways to connect the W321/341 to a PC:
(1) through the serial console port, or
(2) by SSH console over the networ k.
The COM settings for the serial console port are: Baudrate =
115200 bps, Parity = None, Data bits = 8, Stop bits = 1, Flow Control = None.
ATTENTION
Use the CBL
-4PINDB9F-100 cable include d with the
product to connect a PC
to the W321/341’s serial console
port. Remember to choose VT100 terminal type.
To access the SSH console, you will need to know the W321/341’s IP address and netmask. The default LAN settings are shown below. For first-time configurations you may find it con venient to use a crossover Ethernet cable to connect directly from the PC to the W321/341.
Default IP Address
Netmask
LAN 1
192.168.3.127
255.255.255.0
LAN 2 (wireless)
192.168.4.127
255.255.255.0
Once the W321/341 is powered on, the Read y LED will ligh t up and a login page will open. Use the following default username and password to proceed. The defaults are:
Login: root Password: root
8. Configuring the Ethernet Interface
To configure the Ethernet inter face, use the f ollowing commands. Please note that etho0 stands for the IP address of the LAN port, wlan0 stands for the IP address of the wireless LAN.
ifconfig eth0 192 .168.3.127 ifconfig wlan0 192.168.4.127
NOTE
Refer to the W321/341 User’s Manual for information on how to configure the WLAN interface, and for other configuration information.
Loading...