A52/A53 DTE Device RJ45 DB9 Male
TxD 5 2 RxD RxD 6 3 TxD GND 7 5 GND
A52/A53 DCE Device RJ45 DB25 Female
TxD 5 2 RxD RxD 6 3 TxD GND 7 7 GND
RS-422/RS-485 Pinouts
The RS-422/RS-485 port with RJ45 connector or Terminal Block Connector is depicted as
follows.
~RS-422
A52/A53 RJ45 Jack Connector Pinouts Signals
1 TxD -(A) 2 RTS -(A) 3 RTS +(B) 4/7 SG 5 TxD +(B) 6 RxD +(B) 8 CTS +(B) 9 CTS -(A) 10 RxD -(A)
A52/A53 Terminal Block Connector Pinouts Signals
1 TxD +(B) 2 TxD -(A) 3 RxD +(B) 4 RxD -(A) 5 SG 6 Power GND 7 VCCA (9V)
Note: Pins 6 and 7 of the Term inal Block are for
Power GND and Power Input, which is an alternate option for power adapter. Be careful TO NOT confuse RS-422/RS-485 GND with Power GND. SG: Signal Ground
~RS-485
A52/A53 RJ45 Jack Connector Pinouts Signals
1 Data-(A) 4 SG 5 Data+(B)
7 SG
A52/A53 Terminal Block Connector Pinouts Signals
1 Data+(B) 2 Data-(A) 5 SG 6 Power GND 7 VCCA 9V
Note : Pins 6 and 7 of the Term inal Block are for
Power GND and Power Input, which is an alternate option for power adapter. Be careful TO NOT confuse RS-422/RS-485 GND with Power GND. SG: Signal Ground
Transio A52/53
Smart RS-232 to RS-422/485 Bi-directional Converter
Overview
Transio A52/53 is a smart RS-232 to RS-422/485 bi-directional converter, which allows one RS-232 port to be converted into an RS-422 or RS-485 port. With A52/53 you can control up to 32 devices, within 1.2 km, in a multidrop environment.
Transio A52/53 is a Moxa Green Product. Moxa’s Green Products satisfy the RoHS directive of the European Parliament, and accordingly, do not contain cadmium and cadmium compounds, hexavalent chromium compounds, lead and lead compounds, mercury and mercury compounds, PBBs (polybrominated biphenyls), or PBDEs (polybrominated diphenyl ethers).
To ease 2-wire RS-485 half-duplex control, fully Automatic Data Direction Control (ADDC) intelligence that requires no baud rate switch settings is designed into each A52/53, simplifying RS-485 software programming. Your applications can easily manage data transmitting and receiving via the half-duplex RS-485 port without using additional code. Compared to other products that require setting the clock speed manually with switches, A52/53 lets you avoid many developing and
maintenance hassles.
To meet the high reliability required by harsh industrial environments, all RS-422/485 signals provide TVS protection, and ESD up to 25 KV. In addition, A53 provides 2 KV of optical isolation protection for all signals at the RS-422/485 end.
Features and Specifications
Serial interface: RS-232, RS-422/485
Port types: RS-232: RJ45;
RS-422/485: RJ45 or T e rminal Block
High speed, baud rate up to 921.6 Kbps; no
switch setting needed
Signals:
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND; RS-422: TxD+(B)/-(A), RxD+(B)/-(A), RTS+(B)/-(A), CTS+(B)/-(A), GND; RS-485-Data+(B)/-(A), GND
Supports fully Automatic Data Direction
Control (ADDC) with no baud rate switch settings for RS-485
RS-485 data control m odes: auto (ADDC) or
by RTS
RS-422 supports CT S, RTS signals for
hardware flow control
LED indicators for power and 4 signal states
(TxD, RxD, RTS, CTS)
All RS-422/485 signals provide TVS
protection. (ESD 8 KV, EFT 2KV)
All RS-422/485 signals support up to 2 KV
(DC) of optical isolation protection (A53 only)
Provides overloading protection when there
are 2 signals shorted together at the RS-422/485 end
Built-in 120 ohm term ination resistors for
RS-422/RS-485 (selectable with jumper by RS-485 mode)
Supports up to 32 units connected in an
RS-485 multidrop network
CE approval
9V 1.5A UL/ TÜV 110V/230V power
adapter can support up to 4 converters
An external power adapter is required, with
input voltage for the converter ranging from
DC +9V to +30V.
Operating temperature: 0 to 55°C
Dimensions: 90 x 60 x 21 mm
Mounting Kit: Plastic Plates and screws for
mounting A52/53 on the wall or any surface.
Power consumption: A52: 157 mA max.
(+9V); A53: 270A max. (+9V)
Applications
Multipoint data acquisition
Factory automation
Remote serial device control
Building security automation
Critical industrial control
1 2 3 4 5 6 7
RJ45 Connector
Terminal Block Connector
1 2 3 4 5 6 7 8 9 10
RJ45 Plug Pin 1
RS-422/485 RS-232
Mounting Screw
Fixing Screw
RJ45 Plug Pin 1
RS-422/485 R45 ConnectorJ
Power Jack
RS-232 R45 ConnectorJ
External Power Connection
RS-422/485 Te r m i n a l B l o c k
Transio A52/53 User’s Manual Transio A52/53 User’s Manual
Installation
Switch and jumper settings
To change the operation mode, remove the two screws on top of the converter, open the cover, and then use the array of sliding switches to set the desired mode.
DIP switches are used to select the operation mode (RS-422 or RS-485). For RS-485 mode, the control mode (By RTS or ADDC) is also set by DIP switch.
Internal view of A52/53
SW1 RS-422 mode Off RS-485 mode On*
SW2 By RTS Off Auto Data Direction Control (ADDC) On*
(* Default settings)
In RS-422 mode, RxD is automatically set with a 120 ohm terminating resistor. In RS-485 mode, the 120 ohm terminating resistor is set by one jumper. When shorted, the resistor is enabled.
Basic Communication Wiring
Before placing a converter in an existing network, the converter should be properly configured. The following diagrams show typical layouts for both converters.
LED Indicators
LED indicators for TxD, RxD, RTS, CTS signals and PWR are located on top of A52/A53. The indicator light is NOT lit when there is no signal, or the power is off.
TxD: Shows green when connected and
transmitting data from RS-232 to RS-422/485.
RxD: Shows green when connected and
receiving data from RS-232 to RS-422/485.
RTS: Shows green when connected and
RS-232 RTS Signal is ON.
CTS: Shows green when connected and
RS-232 CTS Signal is ON.
PWR: Shows green when power is ON.
Power supply
A52/53 converters are designed for standard +24 VDC unregulated power for use in industrial
environments. Operation is
guaranteed when using any power supply between +9 and +30 VDC, 350 mA. An optional power adapter (9V 1.5A UL/TUV 110V/230V) can support up to 4 converters (see the following diagram).
A52/53 Converter Connection Diagram
RS-232 Pinouts
The RJ45 port for the RS-232 signal is shown in the following figure.
110
A52/A53 RJ45 Connector Pinouts RS-232 Signals
1 DCD Always On 2 DSR 3 RTS 4 GND 5 TxD 6 RxD 7 GND 8 CTS 9 DTR 10
Note: Each group of (DTR, DSR) pins are
shorted, freeing users from the hardware flow control cable wiring problem. For this reason, we list two types of RS-232 cable wiring below.
Type 1: To connect the RS-232 side of A52/A53 to
a DTE (e.g., PC COM1/2) or DCE (Be sure to check the precise DTE/DCE pinouts. The following DTE/DCE pinouts are just an example)
A52/A53 DTE Device RJ45 DB25 Male
DCD 1 8 DCD DSR 2 20 DTR RTS 3 5 CTS GND 4 7 GND TxD 5 3 RxD RxD 6 2 TxD GND 7 7 GND CTS 8 4 RTS DTR 9 6 DSR
A52/A53 DTE Device RJ45 DB9 Male
DCD 1 1 DCD DSR 2 4 DTR RTS 3 8 CTS GND 4 5 GND TxD 5 2 RxD RxD 6 3 TxD GND 7 5 GND CTS 8 7 RTS DTR 9 6 DSR
A52/A53 DCE Device RJ45 DB25 Female
DCD 1 8 DCD DSR 2 6 DTR RTS 3 4 CTS GND 4 7 GND TxD 5 2 RxD RxD 6 3 TxD GND 7 7 GND CTS 8 5 RTS DTR 9 20 DSR
Type 2: You can connect the RS-232 side of
A52/A53 to a DTE, e.g., a terminal or PC COM1/2, with 3-pin wiring if you don't need hardware flow control.
A52/A53 DTE Device RJ45 DB25 Male
TxD 5 3 RxD RxD 6 2 TxD GND 7 7 GND
10-pin RJ45 Jack
AUTO
485
RTS 422
JP
T X D
R X D
R T S
C T S
P W R
RJ45 Plug Pin 1
RJ45 Plug Pin 1
RJ45 Plug Pin 1
RJ45 Plug Pin 1
Po we r
Po we r G N D
RS-422/485
RS-422/485
RS-2 32
PC
Po we r
TxD ( 2 ) RxD(3 ) RTS(4) CTS(5) DSR(6 ) GND(7) DCD(8) DTR(20)
RxD(2 ) Data+ (B)) T xD(3) Data-(A) CTS(4) GND RTS(5) DT R(6) GND(7) DCD(8) DSR(20)
Dat a+ (B) Dat a GND
-(A)
RS-232
RS-485
Host
D25 Female Connector
B
A52/5 3 Co n vert e r
RS-4 85 De vic e s
TxD ( 2 ) RxD(3 ) RTS(4) CTS(5) DSR(6) GND(7) DCD(8) DTR(20)
RxD(2 ) TxD+ (B)) TxD(3) TxD-(A) CTS(4) RxD+ (B) RTS(5) RxD-(A) DTR(6) G ND GND(7) DCD(8) DSR(20)
RxD+ ( B) TxD + ( B )
TxD - ( A ) GND
RxD -( A)
RS-23 2
Host
D25 Female Connector
B
A52/53 Converter
RS-4 22 D ev ic e s
Loading...