Overview
The ToughNet TN-5510A-2GLSX-ODC and TN-5510A-8POE-2GLSX-ODC series M12 managed Ethernet switches are designed for industrial applications in harsh environments. The TN series switches use M12 connectors to ensure tight, robust connections, and guarantee reliable operation against environmental disturbances, such as vibration and shock. The wide 24 to 110 VDC range with dual power inputs (non-PoE series) increases the reliability of your communications.
The TN-5510A-2GLSX-ODC and TN-5510A-8PoE-2GLSX-ODC switches provide up to 8 Fast Ethernet M12 ports, and 2 ports on the down side to provide the Gigabit fiber interface with an embedded 2 km multimode fiber transceiver. Moreover, the -40 to 75°C operating temperature and IP54-rated waterproof enclosure allow deployment in harsh environments. The TN-5510A Ethernet switch is compliant with the essential sections of EN 50155 (railway applications), making it suitable for a variety of industrial applications.
Package Checklist
The ToughNet TN-5510A-2GLSX-ODC and TN-5510A-8POE-2GLSX-ODC switches are shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance.
1 Moxa ToughNet switch
M12 to DB9 console port cable
2 protective caps for console and relay output ports
Panel mounting screws
CD-ROM with user’s manual
Hardware installation guide
Warranty card
Features
Anti-Vibration Circular Connectors for Robust Links
M12 D-coding 4-pin female connectors for Fast Ethernet
10/100BaseT(X) ports
Fiber-optic ODC connectors with embedded 2 km Gigabit Ethernet
1000BaseLSX
M12 A-coding 5-pin male connectors for console and relay output
M23 6-pin male connector for power input
Dual Power Inputs
Supports 24-110 VDC (16.8 to 137.5 VDC)
High Performance Network Switching Technology
IEEE 1588 PTP (Precision Time Protocol) for precise time
synchronization of networks
DHCP Option 82 for IP address assignment with different policies
EtherNet/IP and Modbus/TCP industrial Ethernet protocols supported
Turbo Ring and Turbo Chain (recovery time <20 ms @250 switches),
and STP/RSTP/MSTP for network redundancy
IGMP Snooping and GMRP for filtering multicast traffic from industrial
Ethernet protocols
Port-based VLAN, IEEE802.1Q VLAN, and GVRP protocol to ease
network planning
www.ipc2u.ru
www.moxa.pro
- 3 -
QoS (IEEE 802.1p/1Q and ToS/DiffServ) allows real-time traffic
classification and prioritization
802.3ad, LACP for optimum bandwidth utilization
TACACS+, SNMPv3, IEEE 802.1X, HTTPS, and SSH to enhance
network security
SNMP v1/v2c/v3 for different levels of network management
RMON for efficient network monitoring and proactive capability
Bandwidth management prevents unpredictable network status
Lock port allows access by only authorized MAC addresses
Port mirroring for online debugging
Automatic warning by exception through email, relay output
Automatic recovery of connected device’s IP addresses
Line-swap fast recovery
LLDP for automatic topology discovery in network management
software
Loop protection prevents network loops
Configurable through Web browser, Telnet/serial console, CLI, and
Windows utility
Designed for Industrial-Specific Applications
Two Gigabit fiber ports to meet high EMI immunity, long-distance,
and bandwidth requirements
Essential compliance with EN 50155
-40 to 75°C operating temperature range
IP54, rugged high-strength case
Panel mounting or DIN rail mounting installation capability
Recommended Optional Accessories
CBL-M23(FF6P)Open-BK-100-IP67: 1-meter M23 to 6-pin power
cable with IP67-rated female 6-pin M23 connector
CBL-M12D(MM4P)/RJ45-100 IP67: 1-meter M12-to-RJ45 Cat-5E UTP
Ethernet cable with IP67-rated male 4-pin M12 D-coded connector
CBL-M12(FF5P)/OPEN-100 IP67: 1-meter M12-to-5-pin power cable
with IP67-rated female 5-pin M12 A-coded connector
M12D-4P-IP68: Field-installable M12 D-coded screw-in connector,
male 4-pin, IP68-rated
M12A-5P-IP68: Field-installable M12 A-coded screw-in connector,
female 5-pin, IP68-rated
CAP-M12F-M: Metal cap for M12 female connector
DK-DC50131: DIN rail mounting kit, 50 x 131 mm
www.ipc2u.ru
www.moxa.pro
- 4 -
TN-5510A-2GLSX-ODC Panel Layouts
1. Screw holes for panel mounting kit
2. Console port
3. Grounding screw
4. Relay output port
5. Power input voltage range indicator
6. Power input port (male 6-pin shielded M23 connector)
7. PWR1 LED: for power input 1
www.ipc2u.ru
www.moxa.pro
- 5 -
8. PWR2 LED: for power input 2
9. FAULT LED
10. MSTR/HEAD LED: for ring master or chain head
11. CPLR/TAIL LED: for ring coupler or chain tail
12. TP port’s 10/100 Mbps LED
13. 10/100BaseT(X) port (female 4-pin shielded M12 connector with D
coding)
14. Waterproof vent
15. Product label
16. 12 screw holes for DIN rail mounting kit
17. E2 LED: Down-side E2 Gigabit ports 1000 Mbps LED
18. E1 LED: Down-side E1 Gigabit ports 1000 Mbps LED
19. Gigabit fiber port E1 (corresponding to port 9 in the TN-5510A Users
Manual)
20. Gigabit fiber port E2 (corresponding to port 10 in the TN-5510A
Users Manual)
ATTENTION
Please DO NOT open or remove vent 15. The warranty will be invalid if the seal is removed. All exposed connectors, including 3, 5, 7, and 14, should be tightly covered by protective caps when they are not in use to ensure IP54 protection.
www.ipc2u.ru
www.moxa.pro
- 6 -
Mounting Dimensions (unit = mm)
TN-5510A-2GLSX-ODC Series
www.ipc2u.ru
www.moxa.pro
- 7 -
TN-5510A-8PoE-2GLSX-ODC Series
www.ipc2u.ru
www.moxa.pro
- 8 -
Panel/Wall Mounting
STEP 1:
Mounting the TN-5510A to a wall requires 4 screws. Use the ToughNet switch as a guide to mark the correct positions of the 4 screws.
STEP 2:
Use the 4 screws in the panel mounting kit. If you would like to use your own screws, make sure the screw head is between 6.0 mm and 7.0 mm in diameter and the shaft is less than 4.0 mm in diameter, as shown at the right.
Do not screw the screws in all the wayleave a space of about 2 mm to allow room for sliding the ToughNet switch between the wall and the screws.
NOTE
Before tightening the screws into the wall, make sure the screw head and shaft size are suitable by inserting the screw through one of the keyhole-shaped apertures of the ToughNet switch.
STEP 3:
Once the screws are fixed in the wall, hang the ToughNet switch on the 4 screws through the large opening of the keyhole-shaped apertures, and then slide the switch downwards. Tighten the four screws for added stability.
NOTE
To provide greater protection from vibration and shock, use screws with shaft diameter between 6.0 mm and 7.0 mm, and fix the ToughNet switch onto the wall directly through the large opening of the keyhole-shaped apertures.
www.ipc2u.ru
www.moxa.pro
- 9 -
DIN Rail Mounting (optional)
Use a pair of optional DK-DC50131 DIN rail mounting kits (must be purchased separately) to mount the TN-5510A on a 35 mm DIN rail.
STEP 1:
Use 12 screws (6 screws per plate) to attach the two DIN rail attachment plates to the rear panel of the switch.
STEP 2:
If the spring-loaded bracket is locked in place, push the recessed button to release it. Once released, you should feel some resistance from the spring as you slide the bracket up and down a few millimeters in each direction.
STEP 3:
Insert the top of the DIN rail into the top slot of the DIN rail attachment plates.
STEP 4:
The DIN rail attachment plates will snap into position, as shown in the figure below.
To remove the Moxa ToughNet Switch from the DIN rail, use a screwdriver to pull down the bottom parts of the two spring-loaded brackets until they are fixed in the “locked” position, and then reverse Steps 3 and 4 above.
www.ipc2u.ru
www.moxa.pro
- 10 -
Wiring Requirements
WARNING
Turn the power off before disconnecting modules or wires. The correct power supply voltage is listed on the product label. Check the voltage of your power source to make sure you are using the correct voltage. Do NOT use a voltage greater than what is specified on the product label. These devices must be supplied by a SELV source as defined in the Low Voltage Directive 2006/95/EC and 2004/108/EC.
ATTENTION
Safety First!
Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your Moxa switch. This device has UL 508 approval. Use copper conductors only, 60/75°C, and tighten to 4.5 pound-inches. For use in pollution degree 2 environments.
Please read and follow these guidelines:
Use separate paths to route wiring for power and devices. If power
wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
NOTE
Do not run signal or communications wiring and power wiring through the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.
You can use the type of signal transmitted through a wire to
determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
Keep input wiring and output wiring separated.
It is strongly advised that you label wiring for all devices in the system
when necessary.
www.ipc2u.ru
www.moxa.pro
- 11 -
Grounding the ToughNet Switch
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the grounding screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded mounting surface such as a metal panel.
Connecting the Power Supplies
In non-PoE switches, the ToughNet TN-5510A series switches support two sets of power inputpower input 1 and power input 2. The M23 6-pin male connector on the TN-5510A non-PoE switches’ front panel is used for the dual power inputs.
Pinouts for the power input port on the TN-5510A (non-PoE series)
Pinouts for the power input port on the TN-5510A-PoE series
www.ipc2u.ru
www.moxa.pro
- 12 -
Pinouts for the power input port on the TN-5510A
Pin
Description
Usage
1
PWR1 Live / DC +
Connect “PWR1 Live / DC +” to the positive
(+) terminal when using a DC power source.
2
PWR1 Neutral / DC -
Connect PWR1 Neutral / DC - to the negative (-) terminal when using a DC power source. The negative inputs for the two power supplies are N1/V- and N2/V-.
3
Chassis Ground
Connect the “Chassis Ground” to the
equipment ground bus for DC inputs.
4
PWR2 Neutral / DC -
Connect PWR2 Neutral / DC - to the negative (-) terminal when using a DC power source. The negative inputs for the two power supplies are N1/V- and N2/V-.
5
PWR2 Live / DC +
Connect “PWR2 Live / DC +” to the positive
(+) terminal when using a DC power source.
STEP 1:
Plug your power cord’s M23 connector into the power input port of the TN-5510A switch.
STEP 2:
Screw the nut on your power cord connector to the power input connector on the switch to ensure a tight connection.
ATTENTION
Before connecting the TN-5510A to the power input, make sure the power source voltage is stable.
Connecting the Relay Outputs
Each TN-5510A switch has two sets of relay outputsrelay output 1 and relay output 2. The M12 A-coded 5-pin male connector on the TN-5510A’s front panel is used for the two relay outputs. Use a power cord with an M12 A-coded 5-pin female connector to connect the relay contacts from the switch. You may purchase an M12 power cable from Moxa. The model number of the cable, which must be purchased separately, is CBL-M12 (FF5P)/OPEN-100 IP67.
Pinouts for the relay output port on TN-5510A
N.C.: Not connected
FAULT:
The two sets of relay contacts of the M12 A-coded 5-pin male connector are used to detect user-configured events. The two wires attached to the fault contacts form an open circuit when a user-configured event is triggered. If a user-configured event does not occur, the fault circuit remains closed.
www.ipc2u.ru
www.moxa.pro
- 13 -
RS-232 Connection
The TN switch has one RS-232 (M12 5-pin) console port, located on the front panel. Use an M12-to-DB9 console cable to connect the TN switch’s console port to your PCs COM port. You may than use a console terminal program, such as Moxa PComm Terminal Emulator to access the TN switchs configuration utility.
M12 Console Port Pinouts
Connecting the Data Lines
10/100BaseT(X) Ethernet Port Connection
All TN-5510A models have 8 10/100BaseT(X) Ethernet ports (4-pin shielded M12 connector with D coding). The 10/100BaseTX ports located on the TN-5510A’s front panel are used to connect to Ethernet-enabled devices. Most users configure these ports for Auto MDI/MDI-X mode, in
which case the port’s pinouts are adjusted automatically depending on
the type of Ethernet cable used (straight-through or cross-over), and the type of device (NIC-type or HUB/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-type) ports. We also give cable wiring diagrams for straight-through and cross-over Ethernet cables.
Pinouts for the 10/100BaseT(X) Ports on the TN-5510A
Pinouts for the 1000BaseLSX Q-ODC® Gigabit Fiber port
Mating Sequence
Push plug slightly into connector socket
Rotate to find keying position
Unmated – push connector to mate
Mated – connector snaps in and is fully strain relieved
Pull coupling ring to unmate
www.ipc2u.ru
www.moxa.pro
- 14 -
M12 (4-pin, M) to M12 (4-pin, M) Cross-Over Cable Wiring
M12 (4-pin, M) to M12 (4-pin, M) Straight-Trough Cable Wiring
M12 (4-pin, M) to RJ45 (8-pin) Cross-Over Cable Wiring
M12 (4-pin, M) to RJ45 (8-pin) Straight-Trough Cable Wiring
ATTENTION
The protective cover must be fixed properly to ensure IP54 protection. Use a torque wrench set to a torque of 4 kgf-m when tightening the screws. Note that applying a larger torque may damage the plastic protective cover.
www.ipc2u.ru
www.moxa.pro
- 15 -
LED Indicators
Several LED indicators are located on the ToughNet switch’s front panel. The function of each LED is described in the following table.
LED
Color
State
Description
System LEDs
PWR1
AMBER ON
Power is being supplied to power input PWR1.
OFF
Power is not being supplied to power input PWR1
PWR2
AMBER ON
Power is being supplied to power input PWR2.
OFF
Power is not being supplied to power input PWR2.
FAULT
RED
ON
When the corresponding PORT alarm is enabled, and a user-configured event is triggered.
OFF
When the corresponding PORT alarm is enabled and a user-configured event is not triggered, or when the corresponding PORT alarm is disabled.
MSTR/ HEAD
GREEN
ON
When the TN switch is either the Master of this Turbo Ring, or the Head of this Turbo Chain.
Blinking
When the TN switch is Ring Master of this Turbo Ring and the Turbo Ring is broken, or it is Chain Head of this Turbo Chain and the Turbo Chain is broken.
OFF
When the TN switch is neither the Master of this Turbo Ring, nor the Head of this Turbo Chain.
CPLR/ TAIL
GREEN
ON
When the TN switch enables the coupling function to form a back-up path in this Turbo Ring, or it is the Tail of this Turbo Chain.
Blinking
When the Turbo Chain is down.
OFF
When the TN switch disables the coupling function of Turbo Ring, or it is not the Tail of the Turbo Chain.
Ports LEDs
TP (10/ 100M)
AMBER ON
TP port’s 10 Mbps link is active.
Blinking
Data is being transmitted at 10 Mbps.
OFF
TP port’s 10 Mbps link is inactive.
GREEN ON
TP port’s 100 Mbps link is active.
Blinking
Data is being transmitted at 100 Mbps.
OFF
TP port’s 100 Mbps link is inactive.
PoE Ports
AMBER ON
Power is being supplied to a Powered Device (PD)
OFF
Power is not being supplied to a Powered Device (PD)
E1/E2 (1000M)
GREEN ON
TP port’s 1000 Mbps link is active.
Blinking
Data is being transmitted at 1000 Mbps.
OFF
TP port’s 1000 Mbps link is inactive.
www.ipc2u.ru
www.moxa.pro
- 16 -
Specifications
Technology
Standards
IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) IEEE 802.3x for Flow Control IEEE 802.1D for Spanning Tree Protocol IEEE 802.1w for Rapid STP IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP
Protocols
IGMP v1/v2 device, GMRP, GVRP, SNMP v1/v2C/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, LLDP, IEEE 1588 PTP, IPv6, NTP Server/Client, EtherNet/IP, Modbus/TCP
MIB
MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow Control
IEEE802.3x flow control, back pressure flow control
Switch Properties
Priority Queues
4
Max. Number of Available VLANs
64 VLAN ID Range
VID 1 to 4094
IGMP Groups
256
Interface
Fast Ethernet
Front cabling, M12 connector, 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
Gigabit Ethernet
Down cabling, M12 connector, 1000BaseLSX
Console Port
M12 A-coding 5-pin male connector
System LED Indicators
PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL
Port LED Indicators
10/100M (Fast Ethernet port), 10/100/1000M (Gigabit Ethernet port), PoE
Alarm Contact
Two relay outputs in one M12 A-coding 5-pin male connector with current carrying capacity of 1 A @ 30 VDC
Power Requirements
Input Voltage
WV: 24–110 VDC (16.8 to 137.5 VDC)
Input Current
TN-5510A-2GLSX-ODC Series: 0.45 A TN-5510A-8PoE-2GLSX-ODC Series: 7.8 A
Connection
M23, 6-pin male connector
Overload Current Protection
Present
Reverse Polarity Protection
Present
www.ipc2u.ru
www.moxa.pro
- 17 -
Physical Characteristics
Housing
Metal, IP54 protection (with protective caps on unused ports)
Dimensions (W H  D)
TN-5510A-2GLSX-ODC Series: 185 x 204.3 x 76.0 mm (7.28 x 8.04 x 2.99 in) TN-5510A-8PoE-2GLSX-ODC Series: 185 x 204.3 x 115 mm (7.28 x 8.04 x 4.53 in)
Weight
TN-5510A-2GLSX-ODC Series: 1,805 g TN-5510A-8PoE-2GLSX-ODC Series: 2,690 g
Installation
Panel mounting, DIN-Rail mounting (with optional kit)
Environmental Limits
Operating Temperature
-40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Operating Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety
UL/cUL 508
Rail Traffic
EN50155, EN50121-3-2, EN50121-4
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), level 3 EN61000-4-3 (RS), level 3 EN61000-4-4 (EFT), level 3 EN61000-4-5 (Surge), level 3 EN61000-4-6 (CS), level 3 EN61000-4-8
Shock
IEC61373
Freefall
IEC60068-2-32
Vibration
IEC61373
Note: Please check Moxa’s website for the most up-to-date certification status.
Warranty
5 years Details: See www.moxa.com/warranty
Technical Support Contact Information
www.moxa.com/support
Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505
Moxa Europe: Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99
Moxa Asia-Pacific: Tel: +886-2-8919-1230 Fax: +886-2-8919-1231
www.ipc2u.ru
www.moxa.pro
Loading...