Overview
The Moxa ToughNet TN-5305 series of 5-port Ethernet switches provides a hardened and cost-effective solution for your Ethernet connections. The TN-5305 switches are IP67-rated to provide protection against shock and foreign particles. IP67-rated products have the following characteristics: (1) dust proof, (2) protection against the effects of temporary immersion in water.
The TN-5305 switches have a wide operating temperature range of -40 to75°C, and are designed to withstand a high degree of vibration and shock. The rugged hardware design makes the TN-5305 switches perfect for ensuring that your Ethernet equipment can withstand the rigors associated with critical industrial applications. The switches are rated for use in hazardous locations and comply with CE/FCC, UL and EN50155 (railway applications) standards.
Package Checklist
Your TN-5305 is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.
Moxa ToughNet Switch.
Hardware Installation Guide.
Product Warranty Statement.
3 protective caps for unused ports and 8 port labels.
Panel Mounting Kit.
Features
High Performance Network Switching Technology
5 10/100BaseT(X) ports (4-pin shielded M12 socket with D coding).
Broadcast storm protection.
IEEE802.3/802.3u/802.3x.
Store and Forward switching process type.
10/100M, Full/Half-Duplex, MDI/MDIX auto-sensin g.
Industrial Grade Reliability
Active circuit protection.
Robust connection.
Dust and immersion proof.
Rugged Design
Casing design meets IP67 protection standards.
M12 connectors for robust connections.
Operating temperature range of -25 to 60°C, or extended operating
temperature range of -40 to 75°C.
- 2 -
Front Panel View
5305 to a wall with screws
bottom left,
TN-5305 Panel Layouts
1. M12 port’s 10/100 Mbps LED.
2. 10/100BaseT(X) port (4-pin female shielded M12 socket with D coding).
3. Port Label.
4. Power input (5-pin male shielde d M12 socket with A coding).
5. Power input (PWR) LED.
6. Model name.
7. Holes for attaching the TN­(there are 3 holes: bottom right, and top middle).
8. Grounding screws.
Mounting Dimensions (unit = mm)
- 3 -
STEP 2:
Position the top hook of the DIN top edge of the rail.
STEP 3: Rotate the switch downwards until the bottom of the attachment plate latches onto the bottom edge of the rail.
Panel/Wall Mounting
To mount the TN-5305 on the wall use the 3 screws included in the panel mounting kit.
STEP 1: Make 3 screw holes on the wall based on the positions of the 3 screw holes on the switch shown in the mounting dimensions diagram.
STEP 2: Insert one screw in the top-middle screw hole on the switch and screw it into the wall.
STEP 3: Screw in the remaining 2 screws through the bottom-left and bottom-right holes on the switch.
DIN-Rail Mounting (optional)
Use the optional DIN-Rail mounting kit (DK-M12-305, must be purchased separately) to mount the TN-5305 on a 35-mm DIN rail.
STEP 1:
Fix the DIN-Rail attachment plate to the rear panel of the switch as shown in the above figure.
-Rail attachment plate to the
To remove the switch from the DIN-Rail, simply reverse Steps 2 and 3 above.
- 4 -
WARNING
Turn the power off before correct power supply voltage is listed on the product label. Check the voltage of your power source to make sure that you are using the correct voltage. Do NOT use a voltage greater than what is specified on the product label These devices must be supplied by a SELV source as defined in the Low Voltage Directive 2006/95/EC and 2004/108/EC.
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your Moxa switch. This device has UL508 approval. 60/75°C, Tighten To 4.5 Degree 2 Environment.
ATTENTION
Safety First!
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.
Wiring Requirements
disconnecting modu les or wires. The
.
Use copper conductors only,
pound-inches. For use in Pollution
You should also heed the following guidelines:
Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.
You can use the type of signal transmitted through a wire to determine wh ich wires should be kept se parate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
Keep input wiring and output wiring separated.
It is strongly advised that you label wiring to all devices in the system
when necessary.
- 5 -
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well mounting surface such as a metal panel.
Pin 1
Input V+
Pin 2
Not assigned
Pin 3
Input V-
Pin 4
Not assigned
Pin 5
Function ground
Grounding the TN-5305
-grounded
10/100BaseT(X) Ethernet Port Connection
All TN-5305 models have 5 10/100BaseT(X) Ethernet ports (4-pin shielde d M12 socket with D cod ing). The 10/100TX ports located on the TN-5305’s front panel are used to connect to Ethernet-enabled devices. Most users configure these ports for Auto MDI/MDI-X mode, in which case the port’s pinouts are adjusted automatically depending on the type of Ethernet cable used (straight-through or cross-over), and the type of device (NIC-type or HUB/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-type) ports. We also give cable wiring diagrams for straight-through and cross-over Ethernet cables.
Pinouts for sockets on TN-5305
TP Port
Power input
- 6 -
RJ45 (8-Pin)
MDI Port Pinouts
MDI-X Port Pinouts
Pin
Signal
1
Tx + 2 Tx - 3 Rx + 6 Rx - Pin
Signal
1
Rx + 2 Rx - 3 Tx + 6 Tx -
Pinouts for RJ45 (8-pin)
M12 (4-pin, M) to M12 (4-pin, M) Cross-Over Cable Wiring
M12 (4-pin, M) to M12 (4-pin, M) Straight-Trough Cable Wiring
M12 (4-pin, M) to RJ45 (8-pin) Cross-Over Cable Wiring
- 7 -
LED
Color
State
Description
Power is being supplied to the power input.
Power is not being supplied to the power input.
On
TP port’s 10 Mbps link is active.
Blinkin g
Data is being transmitted at 10 Mbps
Off
TP port’s 10 Mbps link is inactive.
On
TP port’s 100 Mbps link is active
Blinkin g
Data is being transmitted at 100 Mbps.
Off
TP port’s 100 Mbps link is inactive.
M12 (4-pin, M) to RJ45 (8-pin) Straight-Trough Cable Wiring
Auto MDI/MDI-X Connection
The Auto MDI/MDI-X function allows users to connect TN-5305’s 10/100BaseTX ports to any kind of Ethernet device, without needing to pay attention to the type of Ethernet cable being used for the connection. This means that you can use either a straight-through cable or cross-over cable to connect the TN-5305 to Ethernet devices.
LED Indicators
Several LED indicators are located on the TN-5305’s front panel. The function of each LED is described in the table below.
PWR AMBER
LNK/ACT
(10M)
LNK/ACT
(100M)
AMBER
GREEN
On
Off
Auto-Negotiation and Speed Sensing
All of the TN-5305’s Ethernet ports independently support auto-negotiation for speeds in the 10BaseT and 100BaseTX modes, with operation according to the IEEE 802.3u standard. This means that some nodes could be operating at 10 Mbps, while at the same time, other nodes are operating at 100 Mbps.
Auto-negotiation takes place when an M12 cable connection is made, and then each time a LINK is enabled. The TN-5305 advertises its capability for using either 10 Mbps or 100 Mbps transmission speeds, with the device at the other end of the cable expected to advertise in the same way. Depending on what type of device is connected, this will result in agreement to operate at a speed of either 10 Mbps or 100 Mbps.
If an TN-5305’s Ethernet port is connected to a non-negotiating device, it will default to 10 Mbps speed and half-duplex mode, as required by the IEEE 802.3u standard.
- 8 -
Technology
Standards
IEEE 802.3, 802.3u, 802.3x
Processing Type
Store and Forward, with IEEE802.3x full duplex, back pressure flow control
Interface
M12 Ports
10/100BaseTX auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
LED Indicators
Power, LNK/ACT
Power
Input Voltage
24 VDC (12 to 45 VDC) or 18 to 30 VAC (47 to 63 Hz)
Input Current
0.1
0.28A @ 24 VAC
Connection
M12 A-coding 5-pin male connector, single power input
Protection
Overload current protection / Limited current
1.1A Reverse polarity protection
present
Mechanical
Casing
IP67 protection, plastic case
Dimensions (W x H x D)
60 x 125 x 29.6 mm (2.4 x 4.9 x 1.2 in) Weight
250g
Installation
Panel optional kit)
Environment
Operating Temperature
-25 to 60°C (-13 to 140°F) for standard model,
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature
-40 to 85°C (-40 to 185°F)
Operating relative humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety
UL 508
Rail Traffic
EN 50155
Maritime
EMI: FCC Part 15, CISPR (EN55022) class A EMS: EN61000 EN61000 EN6 EN61000 EN61000 Shock: IEC60068 Free Fall: IEC60068 Vibration: IEC60068-2-6
Note: Please check Moxa’s website for the most up-to-date certification status.
MTBF (meantime between failures)
Time
370,224 hrs
Database
Telcordia (Bellcore), GB 25°C
WARRANTY
5 years
Specifications
2A @ 24 VDC
mounting, DIN-Rail mounting (with
-4-2 (ESD), level 3
-4-3 (RS), level 3
1000-4-4 (EFT), level 3
-4-5 (Surge), level 3
-4-6 (CS), level 2
-2-27
-2-32
- 9 -
Technical Support Contact Information
www.moxa.com/support
Moxa Americas: Toll Tel: Fax:
Moxa China (Shanghai office): Toll Tel: Fax:
Moxa Europe Tel: Fax:
Moxa Asia Tel: Fax:
-free: 1-888-669-2872 1-714-528-6777
1-714-528-6778
+49-89-3 70 03 99-0
:
+49-89-3 70 03 99-99
-free: 800-820-5036 +86-21-5258-9955
+86-21-5258-5505
-Pacific:
+886-2-8919-1230
+886-2-8919-1231
- 10 -
Loading...