Moxa Technologies NPort 6650, NPort 6610 Quick Installation Manual

– 1 – – 2 – – 3 –
P/N: 1802066500015
*1802066500015*
Quick Installation Guide
Sixth Edition, August 2015
Overview
The NPort 6600 series of serial device servers includes 8-port, 16-port, and 32-port models for connecting larger numbers of serial devices to Ethernet. Some applications now also require better security when transmitting data through a network. The NPort 6600 series of device servers use DES, 3DES, and AES data encryption to provide secure network communication.
Package Checklist
Before Installing your NPort 6600 series secure device server, verify that the package contains the following items:
• 1 NPort 6600 device server
• CBL-RJ45M9-150: 8-pin RJ45 to DB9 male connection cable, 150 cm
• Power Cord (AC models only)
• 2 rack-mount ears
• Documentation and software CD
• Quick installation guide (printed)
• Warranty card
Optional Accessories
• DK-35A: 35 mm DIN-Rail Mounting Kit
• DIN-Rail Power Supply
• NM-TX01/NM-TX01-T: Network module with one 10/100BaseTX Ethernet port (RJ45 connector; supports cascade redundancy)
• NM-FX01-S-SC/NM-FX01-S-SC-T: N etw ork module with one 100BaseFX single mode fiber port (SC connector; supports cascade redundancy)
• NM-FX02-S-SC/NM-FX02-S-SC-T: N etw ork module with two 100BaseFX single mode fiber ports (SC connectors; supports cascade redundancy)
• NM-FX01-M-SC/NM-FX01-M-SC-T: Network module with one 100BaseFX multi mode fiber port (SC connector; supports cascade redundancy)
• NM-FX02-M-SC/NM-FX02-M-SC-T: Network module with two 100BaseFX multi mode fiber ports (SC connectors; supports cascade redundancy)
NOTE: Please notify your sales representative if any of the above items is missing or damaged.
Hardware Introduction
Demonstrated 8 port model to be an example.
Reset Button
Press the Reset button continuously for 5 sec to load factory defaults: Use a pointed object to press the reset button. Release the button after the Ready LED stops blinking.
RS-485 adjustable pull high/low resistor (150/1 kO)
The NPort 6650 has 3 DIP Switches associated with each serial port for configuring the pull high/low resistors for RS-485 applications. The switches are located in a recess on the bottom of the NPort
6650. To access the switches, first remove the panel covering the recess.
SW 1 2 3
Pull High
Pull Low
Terminator
ON
1 K
1 K
120 K
OFF
150 K
150 K
NOTE: For RS-232 applications, all DIP Switches for the port should be set to the OFF position.
Rack Mounting
Use four screws to attach the NPort 6610/6650 to a standard rack
LED Indicators
Name
Color
Function
PWR
Red
Power is being supplied to the power input.
Ready
Red
Steady on:
Power is on and the NPort 6600 series is booting up.
Blinking:
IP conflict, DHCP or BOOTP server
not responding, or relay output. Check relay output first. If still blinking, then there is an IP conflict, or the DHCP or BOOTP
server did not respond properly.
Green
Steady
on:
Power is on and the NPort 6600
series is functioning normally.
Blinking: The device server has been
located by the Administrator’s
Locator function.
Off Power is off, or power error condition exists.
Link Orange 10 Mbps Ethernet connection.
Green
100 Mbps Ethernet connection.
Off
Ethernet cable is disconnected, or has a short.
P1-P16 Tx
Green
Serial port is transmitting data.
Off
No data is being transmitted through the serial port
P1-P16 Rx
Orange
Serial port is receiving data..
Off
No data is being received through the serial port.
FX
Orange
Steady on:
Ethernet fiber connection, but port is idle.
Blinking:
Fiber port is transmitting or receiving data.
P1-P16
in-use LEDs
Green
Serial port is opened by server side software.
Off
Serial port is not opened by server side software.
Alarm Red
The relay Dout is open (exception)
Off
The relay Dout is Shorted (normal)
Module Green
Network module is plugged in and detected
Off
No module present
LCM Display Panel
The NPort 6600 display panel will show the model name, server name, and IP address when powered up
N P 6 6 1 0 _ 6 6 1 0 2 1 9 2 . 1 6 8 . 1 2 7 . 2 5 4
– 4 – – 5 – – 6 –
www.moxa.com/support
The Americas:
+1-714-528-6777 (toll-free: 1-888-669-2872)
Europe:
+49-89-3 70 03 99-0
Asia-Pacific:
+886-2-8919-1230
China:
+86-21-5258-9955 (toll-free: 800-820-5036)
2014 Moxa Inc., All Rights Reserved
Operating the LCM Panel
There are four push buttons on the NPort 6600’s top panel for operating the server’s LCM panel. The function of each button is described below:
Button
Action
MENU
Activates the main menu, or returns to a lower level.
Scrolls up through a list of items shown on the LCM panel’s second line.
Scrolls down through a list of items shown on the LCM panel’s second line.
SEL
Selects the option listed on the LCM panel’s second line.
Detailed LCM panel operating instructions can be found on the Document and Software CD in the “NPort 6600 Series User’s Manual.”
Note: LCM display panel and push buttons only for standard temprature model
Hardware Installation Procedure
STEP 1: Connect the NPort 6600 device server to a suitable power
source. AC models: Connect the 100 to 240 VAC power cord to the NPort 6600’s power input. DC models: Connect the terminal block to a battery.
STEP 2: Connect the NPort 6600 series to a network. Use a standard straight-through Ethernet cable to connect to a hub or switch. Use a cross-over Ethernet cable when connecting to your computer’s Ethernet port (e.g., when setting up or testing the NPort 6600 server).
STEP 3: Connect the NPort 6600’s serial ports to your serial devices.
Software Installation Information
NPort Search Utility
To install the NPort Search Utility, insert the NPort Document and Software CD into your computer’s CD-ROM drive. When the NPort Installation CD window opens, click on the Installation button, and then follow the instructions on the screen. To view detailed information about the NPort Search Utility, refer to the pdf version of the “NPort 6600 Series User’s Manual,” which is located in the document directory of the CD.
PComm Lite and Console Port (19200, 8, None, 1)
MOXA’s PComm Lite software utility is also included in the Document and Software CD of the CD-ROM. PComm Lite is often used to connect to the NPort 6600 through its console port to configure the IP address for the first time. Use the following serial console parameters when connecting through the console port: 19200, 8, None, 1.
Pin Assignments and Cable Wiring
Pin Assignments (NPort 6610/6650)
Pin RS-232
RS-422,
4-wire RS -485
2-wire RS-485
1
DSR – –
2
RTS
TxD+
3
GND
GND
GND
4
TxD
TxD-
5
RxD
RxD+
Data+
6
DCD
RxD-
Data-
7
CTS – –
8
DTR – –
Pin Mapping for RS-232 Cables (NPort 6610/6650)
NPort6610/6650
Serial Device
RJ45 DB9(M)
DB9(F)
DB25(M)
DB25(F)
DSR
1 6 4 6
20
DTR
RTS
2 7 8 4 5 CTS
GND
3 5 5 7 7 GND
TxD
4 3 2 2 3 RxD
RxD
5 2 3 3 2 TxD
DCD
6 1 1 8 8 DCD
CTS
7 8 7 5 4 RTS
DTR
8 4 6 20 6 DSR
Pin Mapping for RS-422/4W-RS-485 Cables (NPort 6650)
NPort 6650
Serial Device
RJ45 DB9(M)
DB9(F)
DB25(M)
DB25(F)
TxD+
2 7 8 4 5 RxD+
GND
3 5 5 7 7 GND
TxD-
4 3 2 2 3 RxD-
RxD+
5 2 3 3 2 TxD+
RxD-
6 1 1 8 8 TxD-
Pin Mapping for 2W-RS-485 Cables (NPort 6650)
NPort 6650
Serial Device
RJ45 DB9(M)
DB9(F)
DB25(M)
DB25(F)
GND
3 5 5 7 7 GND
Data+
5 2 3 3 2 Data+
Data-
6 1 1 8 8 Data-
Specifications
LAN
Ethernet Ports
10/100 Mbps (RJ45)
Protection
Built-in 1.5 KV magnetic isolation
Serial Interface
NPort 6610 NPort 6650
8, 16, or 32 RS-232 ports (8-pin RJ45) 8, 16, or 32 RS-232/422/485 ports (8-pin RJ45)
Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD,
GND RS-422: Tx+, Tx-, Rx+, Rx-, GND RS-485(2W): Data+, Data-, GND
RS-485(4W): Tx+, Tx-, Rx+, Rx-, GND
RS-485 Data Direction
ADDC™ (Automatic Data Direction Control) Serial Communication Parameters
Parity
None, Even, Odd, Space, Mark
Data bits
5, 6, 7, 8
Stop bit(s)
1, 1.5, 2
Flow control
RTS/CTS, XON/XOFF, DTR/DSR
Speed
50 bps to 921.6 Kbps
Console port
RS-232 console × 1
Memory Expansion Slot
Slot Type
SD socket (supports up to 2 GB)
Power Requirements
Power input
100 to 240 VAC, 47 to 63 Hz, 88 to 300 VDC, ±48 VDC (20 to 72 VDC, -20 to -72 VDC)
Alarm Contact
Relay output with current carrying capacity of 1A @ 24 VDC
Mechanical Specifications
Material
SECC sheet metal (1 mm)
Dimensions (W×D×H)
480×44×195 mm (including ears) 440×44×195 mm (without ears)
Operating Temperatures
Standard Temp. Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
High Voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperatures
Standard and Wide Temp. Models: -40 to 75°C (-40 to 167°F) High Voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Regulatory Approvals
EMC
FCC Class A, CE Class A
Safety
UL, CUL, EN 60950-1
Loading...