Moxa Technologies NPort 6600 Quick Installation Manual

— 1 — — 2 — — 3 —
NPort 6600 Series
Quick Installation Guide
Third Edition, June 2008
1. Overview
2. Package Checklist
Before Installing your NPort 6600 series secure device server, verify that the package contains the following items:
y 1 NPort 6600 series serial device server y Document and Software CD y Quick Installation Guide y Power Cord (for AC models only) y 2 rack-mount ears y CBL-RJ45F9-150: RJ45 to female DB9 cable y Product Warranty Statement
Optional Accessories
y DK-35A: 35 mm DIN-Rail Mounting Kit y DIN-Rail Power Supply y NM-TX01: Network module with one 10/100BaseTX Ethernet port
(RJ45 connector; supports cascade redundancy and RSTP/STP)
y NM-FX01-S-SC: Network module with one 100BaseFX single mode
fiber port (SC connector; supports cascade redundancy and RSTP/STP)
y NM-FX02-S-SC: Network module with two 100BaseFX single mode
fiber ports (SC connectors; supports cascade redundancy and RSTP/STP)
y NM-FX01-M-SC: Network module with one 100BaseFX multi mode
fiber port (SC connector; supports cascade redundancy and RSTP/STP)
y NM-FX02-M-SC: Network module two 100BaseFX multi mode fiber
ports (SC connectors; supports cascade redundancy and RSTP/STP)
y NM-GPRS/GSM: GPRS/GSM modem module y NM-Modem: One PSTN modem port with RJ11 connector
NOTE: Please notify your sales representative if any of the above items is missing or damaged.
3. Hardware Introduction
Serial Ports Console LAN
Network Module
DOUT
AC Power Input
8
LED Indicators
LCM Display
Push Buttons
LED Indicators
SD Connector (internal)
Reset Button
RJ45 Ethernet
Fiber Ethernet
GPRS/GSM Modem
32
/
/
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
48 VDC Power Input
Rear Views
Top View
Front Views
Optional Network Modules
NM-GPRS/GSM
GSM
GPRS
NM-Modem
RxD
LINE
TxD
DCD
Reset button
Press the Reset button continuously for 5 sec to load factory defaults
: Use a pointed object to press the reset button. Release the button after the Ready LED stops blinking.
Adjustable pull high/low resistor for RS-485 (150 KΩ or 1 KΩ)
The NPort 6650 has 3 DIP Switches associated with each serial port for configuring the pull high/low resistors for RS-485 applications. The switches are located in a recess on the bottom of the NPort 6650. To access the switches, first remove the panel covering the recess.
DIP-Switches
1 2 3
SW
Pull High Pull Low Terminator
ON
1 KΩ 1 KΩ 120 KΩ
OFF
150 KΩ 150 KΩ
---
NOTE: For RS-232 applications, all DIP Switches for the port should be set to the OFF position.
Rack Mounting
Use four screws to attach the NPort 6610/6650 to a standard rack
32
/
/
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
LED Indicators
Name Color Function
PWR Red Power is being supplied to the power input.
Steady on:
Power is on and the NPort 6600 series is booting up.
Red
Blinking:
IP conflict, DHCP or BOOTP server not responding, or relay output. Check relay output first. If still blinking, then there is an IP conflict, or the DHCP or BOOTP server did not respond properly.
Steady on:
Power is on and the NPort 6600 series is functioning normally.
Green
Blinking:
The device server has been located by the Administrator’s Locator function.
Ready
Off
Power is off, or power error condition exists.
Orange 10 Mbps Ethernet connection.
Green 100 Mbps Ethernet connection.
Link
Off
Ethernet cable is disconnected, or has a short.
Green Serial port is transmitting data.
P1-P16 Tx
Off
No data is being transmitted through the serial port
Orange Serial port is receiving data..
P1-P16 Rx
Off
No data is being received through the serial port.
Steady on:
Ethernet fiber connection, but port is idle.
FX Orange
Blinking:
Fiber port is transmitting or receiving data.
Green
Serial port is opened by server side software.
P1-P16
in-use LEDs
Off
Serial port is not opened by server side software.
Red The relay Dout is open (exception)
Alarm
Off The relay Dout is Shorted (normal)
Green Network module is plugged in and detected
Module
Off No module present
GSM Green GSM Connection
GPRS Orange GPRS Connection GPRS/GSM Signal Strength
Green
More LEDs indicates better signal; 4 LEDs indicates maximum signal strength.
P/N: 1802066500012
— 4 — — 5 — — 6 —
LCM Display Panel
The NPort 6600 display panel will show the model name, server name, and IP address when powered up
N P 6 6 1 0 _ 6 6 1 0 2 1 9 2 . 1 6 8 . 1 2 7 . 2 5 4
Operating the LCM Panel
There are four push buttons on the NPort 6600’s top panel for operating the server’s LCM panel. The function of each button is described below:
Button Action
MENU Activates the main menu, or returns to a lower level.
Scrolls up through a list of items shown on the LCM panel’s second line.
Scrolls down through a list of items shown on the LCM panel’s second line.
SEL Selects the option listed on the LCM panel’s second line.
Detailed LCM panel operating instructions can be found on the Document and Software CD in the “NPort 6600 Series User’s Manual.”
4. Hardware Installation Procedure
STEP 1: Connect the NPort 6600 device server to a suitable power
source. AC models
: Connect the 100 to 240 VAC power cord to the NPort 6600’s power input. DC models
: Connect the terminal block to a battery.
STEP 2: Connect the NPort 6600 series to a network. Use a standard
straight-through Ethernet cable to connect to a hub or switch. Use a cross-over Ethernet cable when connecting to your computer’s Ethernet port (e.g., when setting up or testing the NPort 6600 server).
STEP 3: Connect the NPort 6600’s serial ports to your serial devices.
5. Software Installation Information
NPort Search Utility
To install the NPort Search Utility, insert the NPort Document and Software CD into your computer’s CD-ROM drive. When the NPort Installation CD window opens, click on the Installation button, and then follow the instructions on the screen. To view detailed inform ation about the NPort Search Utility, refer to the pdf version of the “NPort 6600 Series User’s Manual,” which is located in the document directory of the CD.
PComm Lite and Console Port (19200, 8, None, 1)
MOXA’s PComm Lite software utility is also included in the Document and Software CD of the CD-ROM. PComm Lite is often used to connect to the NPort 6600 through its console port to configure the IP address for the first time. Use the following serial console parameters when connecting through the console port: 19200, 8, None, 1.
6. Pin Assignments and Cable Wiring
Pin Assignments (NPort 6610/6650)
Pin RS-232
RS-422,
4-wire RS -485
2-wire
RS-485
1 DSR --- --­2 RTS TxD+ --­3 GND GND GND 4 TxD TxD- --­5 RxD RxD+ Data+ 6 DCD RxD- Data­7 CTS --- --­8 DTR --- ---
8
1
Pin Mapping for RS-232 Cables (NPort 6610/6650)
NPort
6610/6650
Serial Device
RJ45
DB9(M)
DB9(F) DB25(M) DB25(F)
DSR 1
6
4 6 20 DTR
RTS 2
7
8 4 5 CTS
GND 3
5
5 7 7 GND
TxD 4
3
2 2 3 RxD
RxD 5
2
3 3 2 TxD
DCD 6
1
1 8 8 DCD
CTS 7
8
7 5 4 RTS
DTR 8
4
6 20 6 DSR
Pin Mapping for RS-422/4-wire RS-485 Cables (NPort 6650)
NPort 6650 Serial Device
RJ45
DB9(M)
DB9(F) DB25(M) DB25(F)
TxD+ 2
7
8 4 5 RxD+
GND 3
5
5 7 7 GND
TxD- 4
3
2 2 3 RxD-
RxD+ 5
2
3 3 2 TxD+
RxD- 6
1
1 8 8 TxD-
Pin Mapping for 2-wire RS-485 Cables (NPort 6650)
NPort 6650 Serial Device
RJ45
DB9(M)
DB9(F) DB25(M) DB25(F)
GND 3
5
5 7 7 GND
Data+ 5
2
3 3 2 Data+
Data- 6
1
1 8 8 Data-
7. Specifications
LAN
Ethernet Ports: 10/100 Mbps (RJ45) Protection: Built-in 1.5 KV magnetic isolation Serial Interface NPort 6610: NPort 6650:
8, 16, or 32 RS-232 ports (8-pin RJ45) 8, 16, or 32 RS-232/422/485 ports (8-pin RJ45)
Signals: RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND RS-485(2W): Data+, Data-, GND
RS-485(4W): Tx+, Tx-, Rx+, Rx-, GND Serial Line Protection: 15 KV ESD for all signals RS-485 Data Direction: ADDC™ (Automatic Data Direction Control)
Serial Communication Parameters
Parity: None, Even, Odd, Space, Mark Data bits: 5, 6, 7, 8 Stop bit(s): 1, 1.5, 2 Flow control: RTS/CTS, XON/XOFF, DTR/DSR Speed: 50 bps to 921.6 Kbps Console port: RS-232 console × 1
Storage One SD socket
Power Requirements Power input: 100 to 240 VAC, 47 to 63 Hz,
±48 VDC (20 to 72 VDC, -20 to -72 VDC) Mechanical Specifications
Material: SECC sheet metal (1 mm) Dimensions: (W×D×H)
480×44×195 mm (including ears)
440×44×195 mm (without ears)
Environment
Operating Temp.:0-55°C (32 to 131°F), 5 to 95% RH Storage Temp.: -20 to 85°C (-4 to 185°F), 5 to 95%RH
Regulatory Approvals
EMC: FCC Class A, CE Class A Safety: UL, CUL, TUV
Click here for online support:
www.moxa.com/support
The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872)
Europe: +49-89-3 70 03 99-0
Asia-Pacific: +886-2-8919-1230
China: +86-21-5258-9955 (toll-free: 800-820-5036)
© 2008 Moxa Inc., all rights reserved.
Reproduction without permission is prohibited.
Loading...