Moxa Technologies NPORT 6150, NPORT 6250, NPORT 6250-S-SC, NPORT 6250-M-SC, NPORT 6610 User Manual

...
NPort 6000 Series User’s Manual
Edition 15.0, November 2016
www.moxa.com/product
© 2016 Moxa Inc. All rights reserved.
NPort 6000 Series User’s Manual
Moxa
Toll
Tel:
Fax:
Moxa China (Shanghai office)
Toll
Tel:
Fax:
Moxa Europe
Tel:
Fax:
Moxa As
Tel:
Fax:
Moxa India
Tel:
Fax:
The software described in this manual is furnished under a license agreement and may be used only in accordance with
the terms of that agreement.
© 2016 Moxa Inc. All rights reserved.
Trademarks
The MOXA logo is a registered trademark of Moxa Inc.
All other trademarks or registered marks in this manual belong to their respective manufacturers.
Disclaimer
Information in this document is subject to change without notice and does not represent a commitment on the part of
Moxa.
Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited
to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the
products and/or the programs described in this manual, at any time.
Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for
its use, or for any infringements on the rights of third parties that may result from its use.
This product might include unintentional technical or typographical errors. Changes are periodically made to the
information herein to correct such errors, and these changes are incorporated into new editions of the publication.
Technical Support Contact Information
www.moxa.com/support
Americas
-free: 1-888-669-2872
+1-714-528-6777
+1-714-528-6778
+49-89-3 70 03 99-0
+49-89-3 70 03 99-99
+91-80-4172-9088
+91-80-4132-1045
-free: 800-820-5036
+86-21-5258-9955
+86-21-5258-5505
ia-Pacific
+886-2-8919-1230
+886-2-8919-1231
Table of Contents
1. Introduction ...................................................................................................................................... 1-1
Overview ........................................................................................................................................... 1-2
Package Checklist ............................................................................................................................... 1-2
NPort 6610/6650 ......................................................................................................................... 1-2
NPort 6150, NPort 6250, and NPort 6450 ....................................................................................... 1-3
Product Features ................................................................................................................................ 1-3
Product Selection Chart ....................................................................................................................... 1-4
Product Specifications ......................................................................................................................... 1-5
NPort 6150 ................................................................................................................................. 1-5
NPort 6250/6250-S-SC/6250-M-SC ............................................................................................... 1-6
NPort 6450 ................................................................................................................................. 1-8
NPort 6610/6650 ....................................................................................................................... 1-10
2. Getting Started.................................................................................................................................. 2-1
Panel Layout ...................................................................................................................................... 2-2
NPort 6150/6250 ......................................................................................................................... 2-2
NPort 6450 ................................................................................................................................. 2-2
NPort 6610/6650 ......................................................................................................................... 2-3
Panel, DIN-Rail, and Rack-Mounting ...................................................................................................... 2-4
Connecting the Hardware..................................................................................................................... 2-5
Wiring Requirements ................................................................................................................... 2-5
Connecting the NPort 6600 VDC’s Power ........................................................................................ 2-5
Grounding the NPort 6600 VDC ..................................................................................................... 2-6
Connecting to the Network ........................................................................................................... 2-6
Connecting to a Serial Device ....................................................................................................... 2-6
LED Indicators ............................................................................................................................ 2-6
Adjustable Pull High/Low Resistors for the RS-485 Port .................................................................... 2-7
3. Initial IP Address Configuration ........................................................................................................ 3-1
Static and Dynamic IP Addresses .......................................................................................................... 3-2
Factory Default IP Address ................................................................................................................... 3-2
Configuration Options .......................................................................................................................... 3-2
Device Search Utility .................................................................................................................... 3-2
Web Console ............................................................................................................................... 3-2
LCM Console/Front Panel (NPort 6610, 6650, and 6450 only)............................................................ 3-2
ARP ........................................................................................................................................... 3-3
Telnet Console ............................................................................................................................ 3-4
Serial Console ............................................................................................................................. 3-7
4. Introducing Serial Port Operation Modes .......................................................................................... 4-1
Overview ........................................................................................................................................... 4-2
Guide to NPort 6000 Modes .................................................................................................................. 4-2
Device-Control Applications .................................................................................................................. 4-3
Real COM and Secure Real COM Modes .......................................................................................... 4-3
Reverse Real COM Mode ............................................................................................................... 4-4
RFC2217 Mode ............................................................................................................................ 4-4
Socket Applications ............................................................................................................................. 4-5
TCP Server and Secure TCP Server Modes ...................................................................................... 4-5
TCP Client and Secure TCP Client Modes ......................................................................................... 4-5
UDP Mode .................................................................................................................................. 4-6
Pair Connection and Secure Pair Connection Modes ................................................................................. 4-6
Ethernet Modem Mode ......................................................................................................................... 4-7
Terminal Applications .......................................................................................................................... 4-7
Terminal ASCII Mode ................................................................................................................... 4-8
Terminal BIN Mode ...................................................................................................................... 4-8
SSH Mode .................................................................................................................................. 4-8
Reverse Terminal Applications .............................................................................................................. 4-8
Reverse Telnet ............................................................................................................................ 4-9
Reverse SSH ............................................................................................................................... 4-9
Printer Modes ..................................................................................................................................... 4-9
Dial In/Out Modes ............................................................................................................................. 4-10
Disabled Mode .................................................................................................................................. 4-10
5. Configuration with the Web Console ................................................................................................. 5-1
Using Your Web Browser ...................................................................................................................... 5-2
Browser Cookie Settings............................................................................................................... 5-2
Trusted Site Settings ................................................................................................................... 5-3
Opening the Web Console ............................................................................................................. 5-4
Web Console Navigation ...................................................................................................................... 5-5
Network Configuration ......................................................................................................................... 5-5
Basic Network Settings ................................................................................................................ 5-5
Advanced Network Settings .......................................................................................................... 5-8
Setting up the DDNS ................................................................................................................... 5-9
Configuring the Route Table........................................................................................................ 5-10
6. Module Settings ................................................................................................................................ 6-1
NM-TX01, NM-TX02, NM-FX01-M-SC, NM-FX01-S-SC, NM-FX02-M-SC, NM-FX02-S-SC ................................ 6-2
Using Ethernet Redundancy .......................................................................................................... 6-2
The STP/RSTP Concept ................................................................................................................ 6-3
Differences between RSTP and STP ................................................................................................ 6-5
STP Example .............................................................................................................................. 6-6
Configuring Turbo Ring ........................................................................................................................ 6-8
The Turbo Ring Concept ............................................................................................................... 6-8
Configuring Turbo Ring 2 ............................................................................................................ 6-10
7. Configuring Serial Port Operation Modes .......................................................................................... 7-1
Port Setting Basics .............................................................................................................................. 7-2
Device Control Applications .................................................................................................................. 7-2
Real COM Mode ........................................................................................................................... 7-2
Reverse Real COM Mode ............................................................................................................... 7-5
RFC2217 Mode ............................................................................................................................ 7-7
Socket Applications ............................................................................................................................. 7-8
TCP Server Mode ......................................................................................................................... 7-8
TCP Client Mode ........................................................................................................................ 7-11
UDP Mode ................................................................................................................................ 7-13
Pair Connection Mode ........................................................................................................................ 7-14
Pair Connection Master Mode ...................................................................................................... 7-14
Pair Connection Slave Mode ........................................................................................................ 7-15
Ethernet Modem Mode ....................................................................................................................... 7-16
Terminal Applications ........................................................................................................................ 7-18
Terminal ASCII (TERM_ASC) ....................................................................................................... 7-18
Terminal BIN (TERM_BIN) .......................................................................................................... 7-20
SSH ......................................................................................................................................... 7-21
Reverse Terminal Applications ............................................................................................................ 7-22
Reverse Telnet Mode ................................................................................................................. 7-22
Reverse SSH Mode .................................................................................................................... 7-23
Printer Applications ........................................................................................................................... 7-24
RAW PRN Mode ......................................................................................................................... 7-24
LPD PRN Mode .......................................................................................................................... 7-25
Dial In/Out Applications ..................................................................................................................... 7-25
PPP Mode ................................................................................................................................. 7-25
PPPD Mode ............................................................................................................................... 7-26
SLIP Mode ................................................................................................................................ 7-27
SLIPD Mode .............................................................................................................................. 7-27
Dynamic Mode .......................................................................................................................... 7-28
Disabled Mode .................................................................................................................................. 7-28
8. Additional Serial Port Settings .......................................................................................................... 8-1
Port Communication Parameters ........................................................................................................... 8-2
Serial Parameters ........................................................................................................................ 8-2
Port Data Buffering/Log ....................................................................................................................... 8-3
Port Modem Settings ........................................................................................................................... 8-4
Port Cipher Settings ............................................................................................................................ 8-4
User Table ......................................................................................................................................... 8-5
Welcome Message .............................................................................................................................. 8-5
9. System Configuration Settings .......................................................................................................... 9-1
Basic Settings .................................................................................................................................... 9-2
Server Settings ........................................................................................................................... 9-2
Time Settings ............................................................................................................................. 9-2
Accessible IP List ................................................................................................................................ 9-3
Host Table ......................................................................................................................................... 9-4
Firmware Upgrade .............................................................................................................................. 9-4
Backup/Restore .................................................................................................................................. 9-5
Pre-Shared Key ........................................................................................................................... 9-5
Configuration Import ................................................................................................................... 9-5
Configuration Export .................................................................................................................... 9-6
Certificate .......................................................................................................................................... 9-6
Ethernet SSL/TLS Certificate Import .............................................................................................. 9-6
Certificate/Key Delete .................................................................................................................. 9-7
SSL/TLS Configurations ................................................................................................................ 9-7
10. Administration Settings .................................................................................................................. 10-1
Account Management ........................................................................................................................ 10-2
Notification Message .................................................................................................................. 10-2
User Account ............................................................................................................................ 10-3
Access Permission ..................................................................................................................... 10-4
Password and Login Policy .......................................................................................................... 10-6
SNMP Agent ..................................................................................................................................... 10-7
Authentication Server ........................................................................................................................ 10-8
Console Setting ................................................................................................................................ 10-8
Load Factory Defaults ........................................................................................................................ 10-9
11. Log, Monitoring and Warning .......................................................................................................... 11-1
System Log Settings ......................................................................................................................... 11-2
Configure the Remote Log Server ....................................................................................................... 11-3
System Monitoring ............................................................................................................................ 11-3
Serial Status ............................................................................................................................. 11-3
System Status .......................................................................................................................... 11-5
Auto Warning Settings ..................................................................................................................... 11-10
Event Log Settings .................................................................................................................. 11-10
Event Settings ........................................................................................................................ 11-10
Serial Event Settings ............................................................................................................... 11-11
Email Alert ............................................................................................................................. 11-12
SNMP Trap ............................................................................................................................. 11-13
12. Common Settings and Others .......................................................................................................... 12-1
Common Settings ............................................................................................................................. 12-2
Ping ......................................................................................................................................... 12-2
Change Password ............................................................................................................................. 12-2
Save Configuration ........................................................................................................................... 12-3
Restart ............................................................................................................................................ 12-3
Restart System ......................................................................................................................... 12-3
Restart Ports............................................................................................................................. 12-3
Logout............................................................................................................................................. 12-4
13. Software Installation/Configuration ............................................................................................... 13-1
Overview ......................................................................................................................................... 13-2
NPort Windows Driver Manager .......................................................................................................... 13-2
Installing NPort Windows Driver Manager ..................................................................................... 13-2
Using NPort Windows Driver Manager .......................................................................................... 13-4
Command Line Installation/Removal .......................................................................................... 13-13
Device Search Utility (DSU) ............................................................................................................. 13-15
Installing Device Search Utility .................................................................................................. 13-15
Configuring Device Search Utility (DSU) ..................................................................................... 13-18
Linux Real TTY Drivers .................................................................................................................... 13-19
Basic Procedures ..................................................................................................................... 13-19
Hardware Setup ...................................................................................................................... 13-19
Installing Linux Real TTY Driver Files ......................................................................................... 13-19
Mapping TTY Ports ................................................................................................................... 13-19
Removing Mapped TTY Ports ..................................................................................................... 13-20
Removing Linux Driver Files ...................................................................................................... 13-20
The UNIX Fixed TTY Driver ............................................................................................................... 13-21
Installing the UNIX Driver......................................................................................................... 13-21
Configuring the UNIX Driver ..................................................................................................... 13-21
A. Pinouts and Cable Wiring .................................................................................................................. A-1
Port Pinout Diagrams .......................................................................................................................... A-2
NPort 6150/6250/6450: RS-232/422/485 (male DB9) ..................................................................... A-2
NPort 6600: RS-232/422/485 (male RJ45) ..................................................................................... A-2
Cable Wiring Diagrams ........................................................................................................................ A-3
Ethernet Cables........................................................................................................................... A-3
Serial Cables (RS-232) ................................................................................................................. A-3
Serial Cables (RS-422/4-Wire RS-485) ........................................................................................... A-5
Serial Cables (2-wire RS-485) ....................................................................................................... A-6
Pin Assignments for DB9 and DB25 Connectors ............................................................................... A-7
B. RFC2217 ............................................................................................................................................ B-1
C. Well-Known Port Numbers ................................................................................................................ C-1
D. SNMP Agents with MIB II & RS-232 Like Groups .............................................................................. D-1
RFC1213 MIB-II Supported SNMP Variables .......................................................................................... D-2
RFC1317 RS-232 Like Groups .............................................................................................................. D-3
Moxa-NP6000-MIB ............................................................................................................................. D-4
E. RADIUS Server .................................................................................................................................. E-1
What is RADIUS? ................................................................................................................................ E-2
Definition ................................................................................................................................... E-2
Client/Server Architecture ............................................................................................................ E-2
Setting up the NPort 6000 ................................................................................................................... E-3
Setting up the RADIUS Server IP Address ....................................................................................... E-3
Serial Port Configuration .............................................................................................................. E-3
Setting up UNIX Hosts ......................................................................................................................... E-3
Setting up Windows NT Hosts ............................................................................................................... E-4
Setting up Windows 2000 Hosts ........................................................................................................... E-6
Setting up Windows 2003 Hosts ........................................................................................................... E-8
1

1. Introduction

The NPort 6000 series of secure serial device servers has many exceptional features. More than 20 models
comprise the NPort 6000 series of secure serial device servers. The main differences between the models are
the number of ports and the type of network connection employed. All instructions and information presented
for the NPort 6000 apply to all models in the series. Any differences between models will be specified. Please
refer to the Product Selection Chart section in this chapter for details on differences between models in the
series.
The following topics are covered in this chapter:
Overview
Package Checklist
NPort 6610/6650
NPort 6150, NPort 6250, and NPort 6450
Product Features
Product Selection Chart
Product Specifications
NPort 6150
NPort 6250/6250-S-SC/6250-M-SC
NPort 6450
NPort 6610/6650
NPort 6000 Series Introduction
1-2
NPort 6650-32
32

Overview

The NPort 6000 can be used to connect any serial device to an Ethernet network and supports many different
operation modes. In particular, the NPort 6000 also supports Secure TCP Server, Secure TCP Client, Secure
Pair-Connection, and Secure Real COM modes for security-critical applications, such as banking, telecom,
access control, and remote site management. Moreover, for firmware v1.14 and above, the NPort 6000 series
enhances its security level to comply with industry standard IEC 62443-4-2 at level 2 in the following focused
areas: more secure protocols supported, authentication control, more complex data encryptions, and so on.
The NPort 6000’s Any Baudrate feature, which is based on Moxa’s UART IC, allows the use of nonstandard
baudrates. For example, a baudrate of 500 kbps may be required for some special applications. Many device
servers could only be configured for a baudrate of 460.8 kbps, resulting in an error rate of 7.84%. For serial
communication, the acceptable margin of error is only 3%. The NPort 6000 allows you to configure the
baudrate more accurately, and it can be configured to transmit serial data at the rate of 491.5 kbps. This is only
a 1.7% margin of error, which is well within the acceptable margin for serial data.
For some applications, data must be delivered reliably even if communication is disrupted. The NPort 6000
provides a powerful function to ensure that data is buffered in case of a communication failure. When a
communication failure occurs, the data is stored in the NPort 6000. Upon resumption of communication, the
buffered data will be sent to the destination. The default size of the port buffer is 64 KB for each port. For the
NPort 6610, NPort 6250, NPort 6450, and NPort 6650, users may increase the buffer size by using an external
SD card.

Package Checklist

Each NPort 6000 serial device server is shipped in a separate box, which also includes a number of standard
accessories. In addition, several optional accessories can be ordered separately. When you receive your
shipment, please check the contents of the box carefully and notify your Moxa sales representative if any of the
items are missing or appear to be damaged.

NPort 6610/6650

Six models of the NPort 6610 and eleven models of the NPort 6650 are available:
Model Name Number of Serial Ports Power Requirements
NPort 6610-8 8 RS-232 100 to 240 VAC, power cord
NPort 6610-16 16
NPort 6610-32 32
NPort 6610-8-48V 8 RS-232 ±48 VDC (20 to 72 VDC, -20 to -72 VDC), terminal
NPort 6610-16-48V 16
NPort 6610-32-48V 32
NPort 6650-8/
NPort 6650-8-T
NPort 6650-16/
NPort 6650-16-T
8 RS-232/422/485 100 to 240 VAC, power cord
16
block
NPort 6650-8-48V 8 RS-232/422/485 ±48 VDC (20 to 72 VDC, -20 to -72 VDC), terminal
NPort 6650-16-48V 16
NPort 6650-32-48V 32
NPort 6650-8-HV-T 8 RS-232/422/485 88 to 300 VDC terminal block
NPort 6650-16-HV-T 16
NPort 6650-32-HV-T 32
Standard Accessories for the NPort 6610 and NPort 6650
• 1 NPort 6600 device server
block
NPort 6000 Series Introduction
1-3
• CBL-RJ45M9-150: 8-pin RJ45 to DB9 male connection cable, 150 cm
• Power cord (AC models only)
• 2 rackmount ears
• Software and documentation CD
• Quick installation guide (printed)
• Warranty card
Cable Accessories for the NPort 6610 and NPort 6650 (can be purchased separately)
• CBL-RJ45M9-150 (8-pin RJ45-to-male DB9 cable; 150 cm)
• CBL-RJ45F9-150 (8-pin RJ45-to-female DB9 cable; 150 cm)
• CBL-RJ45M25-150 (8-pin RJ45-to-male DB25 cable; 150 cm)
• CBL-RJ45F25-150 (8-pin RJ45-to-female DB25 cable; 150 cm)
Extension Modules for the NPort 6450 and NPort 6600 (can be purchased separately)
• NM-TX01/NM-TX01-T: Network module with one 10/100BaseTX Ethernet port (RJ45 connector; supports
cascade redundancy)
• NM-TX02/NM-TX02-T: Network module with two 10/100BaseTX Ethernet ports (RJ45 connector; supports
cascade redundancy)
• NM-FX01-S-SC/NM-FX01-S-SC-T: Network module with one 100BaseFX single-mode fiber port (SC
connector; supports cascade redundancy)
• NM-FX02-S-SC/NM-FX02-S-SC-T: Network module with two 100BaseFX single-mode fiber ports (SC
connectors; supports cascade redundancy)
• NM-FX01-M-SC/NM-FX01-M-SC-T: Network module with one 100BaseFX multimode fiber port (SC
connector; supports cascade redundancy)
• NM-FX02-M-SC/NM-FX02-M-SC-T: Network module with two 100BaseFX multimode fiber ports (SC
connectors; supports cascade redundancy)

NPort 6150, NPort 6250, and NPort 6450

One model of the NPort 6150, three models of the NPort 6250, and one model of the NPort 6450 are available:
Model Name Number of Serial Ports Power Requirements
NPort 6150/6150-T 1 100-240 VAC, adapter
NPort 6250/6250-T 2 100-240 VAC, adapter
NPort 6250-M-SC/6250-M-SC-T 2 100-240 VAC, adapter
NPort 6250-S-SC/6250-S-SC-T 2 100-240 VAC, adapter
NPort 6450/6450-T 4 100-240 VAC, adapter
Standard Accessories for the NPort 6150 and NPort 6250
• Software and documentation CD
• Quick installation guide
• Power adapter (standard temp. models only)
• Product warranty statement
• 2 attachable wall-mount ears
DIN-Rail Accessories for the NPort 6150, NPort 6250, and NPort 6450 (can be purchased
separately)
• DK-35A DIN-rail mounting kit (35 mm)
• DIN-rail power supply

Product Features

All models in the NPort 6000 series have the following features:
• Secure data access modes, including Secure Real COM, Secure TCP Server, Secure TCP Client, and Secure
Pair Connection
NPort 6000 Series Introduction
1-4
interface
modules
relay output
slot
RS-485
RS-485
RS-485
RS-485
6610-8
8
RS-232
100-240 VAC
SECC sheet metal (1 mm)
Ethernet
yes
yes
yes
6610-16
16
RS-232
100-240 VAC
SECC sheet metal (1 mm)
Ethernet
yes
yes
yes
6610-32
32
RS-232
100-240 VAC
SECC sheet metal (1 mm)
Ethernet
yes
yes
yes
6610-8-48V
8
RS-232
±48 VDC
SECC sheet metal (1 mm)
Ethernet
yes
yes
yes
6610-16-48V
16
RS-232
±48 VDC
SECC sheet metal (1 mm)
Ethernet
yes
yes
yes
6610-32-48V
32
RS-232
±48 VDC
SECC sheet metal (1 mm)
Ethernet
yes
yes
yes
RS-485
RS-485
RS-485
RS-485
RS-485
RS-485
RS-485
• Versatile socket-operating modes, including TCP Server, TCP Client, UDP, and Real COM driver
• Port-buffering function to prevent loss of serial data when communication is disrupted
• Enhanced remote configuration with HTTPS and SSH
• Definable multi-user account management
• High Secure Mode is supported to disable less secure protocols and cipher suites as well as enforce the
longest key length for data encryptions
• Port speeds of up to 921.6 kbps
• Redundant Ethernet Ring capability (STP, RSTP, Turbo Ring, and Turbo Ring 2)
• Any Baudrate feature for easy configuration for custom baudrates

Product Selection Chart

The following table shows the main differences between the NPort 6000 models:
Product Serial
6150/6150-T 1 RS-232,
6250/6250-T 2 RS-232,
6250-M-SC/
6250-M-SC-T
6250-S-SC/
6250-S-SC-T
6450/6450-T 4 RS-232,
6650-8/
6650-8-T
6650-16/
6650-16-T
6650-32 32 RS-232,
Serial
ports
interface
RS-422,
RS-485
RS-422,
2 RS-232,
RS-422,
2 RS-232,
RS-422,
RS-422,
8 RS-232,
RS-422,
16 RS-232,
RS-422,
RS-485
RS-422,
Power Casing Built-in
network
12 to 48 VDC Aluminum (1 mm) Ethernet
12 to 48 VDC Aluminum (1 mm) Ethernet yes
12 to 48 VDC Aluminum (1 mm) Multimode
Fiber
12 to 48 VDC Aluminum (1 mm) Si ngle-mode
Fiber
12 to 48 VDC Aluminum (1 mm) Ethernet yes yes yes
100-240 VAC SECC sheet metal (1 mm) Ethernet yes yes yes
100-240 VAC SECC sheet metal (1 mm) Ethernet yes yes yes
100-240 VAC SECC sheet metal (1 mm) Ethernet yes yes yes
Optional
network
yes
yes
Configurable
alarm LED and
SD
card
6650-8-48V 8 RS-232,
6650-16-48V 16 RS-232,
6650-32-48V 32 RS-232,
NPort
6650-8-HV-T
NPort
6650-16-HV-T
NPort
6650-32-HV-T
RS-422,
RS-422,
RS-422,
8 RS-232,
RS-422,
16 RS-232,
RS-422,
RS-485
32 RS-232,
RS-422,
±48 VDC SECC sheet metal (1 mm) Ethernet yes yes yes
±48 VDC SECC sheet metal (1 mm) Ethernet yes yes Yes
±48 VDC SECC sheet metal (1 mm) Ethernet yes yes Yes
88-300 VDC SECC sheet metal (1 mm) Ethernet yes yes Yes
88-300 VDC SECC sheet metal (1 mm) Ethernet yes yes Yes
88-300 VDC SECC sheet metal (1 mm) Ethernet yes yes Yes
NPort 6000 Series Introduction
1-5
Ethernet Interface
Number of Ports:
Speed:
Connector:
Magnetic Isolation:
Serial Interface
Number of Ports:
Serial Standards:
Connector:
RS
Console Port:
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits:
Parity:
Flow Control:
Baudrate:
Pull High/Low Resistor for RS-485: 1 KΩ, 150 KΩ
Serial Signals
RS
RS
RS
RS
Software
Network Protocols: ICMP, IPv4/v6, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1/V2c/V3, HTTP, SMTP,
ARP, PPPoE
Security Protocols:
Configuration Options:
Windows Real COM
x86/x64,
2012 x64, Embedded CE 5.0/6.0, XP Embedded
Fixed TTY Drivers:
Solaris 10, FreeBSD, AIX 5.x
Linux R
Management: SNMP MIB-II
IP Routing:
Operation Modes
Standard:
Ethernet Modem, Printer, PPP, Disabled
Secure: Secure Real COM, Secure TCP Server, Secure TCP Client, Secure Pair Connection, SSH, Reverse SSH
Applications
Terminal Sessions:
Physical Characteristics
Housing:
Weight:
Dimensions:
Without ears: 67 x 100.4 x 28 mm (2.64 x 3.95 x 1.1 in)
With ears: 90 x 100.4 x 28 mm (3.54 x 3.95 x 1.1 in)

Product Specifications

NPort 6150

1
10/100 Mbps, auto MDI/MDIX
8-pin RJ45
1.5 KV built-in
1
RS-232/422/485
DB9 male
-485 Data Direction Control: ADDC® (Automatic Data Direction Control)
Serial port doubles as RS-232 console port
1, 1.5, 2
None, Even, Odd, Space, Mark
RTS/CTS, DTR/DSR, XON/XOFF, RTS Toggle
50 bps to 921.6 kbps (supports nonstandard baudrates)
-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-422: Tx+, Tx-, Rx+, Rx-, GND
-485-4w: Tx+, Tx-, Rx+, Rx-, GND
-485-2w: Data+, Data-, GND
, HTTPS
SSLv3, TLSv1.0/1.1/1.2
Web Console, Serial Console, Telnet Console, Windows Search Utility
Drivers: Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/10
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6,
eal TTY Drivers: Linux kernel 2.4.x, 2.6.x, 3.x
Static, RIP-I, RIP-II
Real COM, TCP Server, TCP Client, UDP, Pair Connection, RFC2217, Terminal, Reverse Telnet,
8 sessions per port
Metal
700 g (1.54lb)
NPort 6000 Series Introduction
1-6
Environmental Limits
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models:
Storage Temperature:
Ambient Relative Humidity:
Power Requirements
Input Voltage:
Input Current:
Alarm Contact:
Power Line Protection:
Standards and Certifications
Safety:
EMC:
EMI:
EMS:
IEC 61000
IEC 61000
IEC 61000
IEC 61000
IEC 61000
IEC 61000-4-8 PFMF IEC 61000-4-11 DIPs
Freefall:
Vibration:
Green Product:
Reliability
Alert Tools:
Automatic Reboot Trigger:
MTBF
Time:
Standard:
Warranty
Warranty Period:
Details:
Ethernet Interface
Number of Ports:
Speed:
Connector:
Magnetic Isolation:
Optical Fiber Interface (NPort 6250-S-SC/6250-M-SC)
Fiber
Distance:
Single-mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))
Min. TX Output:
Max. TX Output:
Sensitivity:
-40 to 75°C (-40 to 167°F)
-20 to 75°C (-4 to 167°F)
5 to 95% (noncondensing)
12 to 48 VDC
285 mA @ 12 VDC
Relay output with current-carrying capacity of 1 A @ 24 VDC
1 KV burst (EN61000-4-4: EFT/B), 1 KV surge (EN61000-4-5)
UL 60950-1
55022/24
CISPR 22, FCC Part 15B Class A
-4-2 ESD: Contact: 4 kV; Air: 8 kV
-4-3 RS: 80 MHz to 1 GHz: 3 V/m
-4-4 EFT: Power 1 kV; Signal 0.5 kV
-4-5 Surge: Power 1 kV; Signal: 1 kV
-4-6 CS: 150 kHz to 80 MHz, 3 V/m; Signal: 3 V/m
IEC-68-2-6, IEC-68-2-34, IEC-68-2-32
IEC-68-2-6, IEC-68-2-34
RoHS, CRoHS, WEEE
Built-in buzzer and RTC (real-time clock)
Built-in WDT (watchdog timer)
(mean time between failures)
2,097,705 hrs
Telcordia (Bellcore) Standard TR/SR
5 years
See www.moxa.com/warranty

NPort 6250/6250-S-SC/6250-M-SC

1
10/100 Mbps, auto MDI/MDIX
8-pin RJ45
1.5 KV built-in
Port: 100BaseFX, SC connector
Multimode: 0 to 4 km, 1300 nm (62.5/125 µm, 500 MHz*km)
Multimode: -20 dBm
Single-mode: -5 dBm
Multimode: -10 dBm
Single-mode: 0 dBm
Multimode: -34 to -30 dBm
Single-mode: -36 to -32 dBm
NPort 6000 Series Introduction
1-7
Serial Interface
Number of Ports:
Serial Standards:
Connector:
RS
Console Port:
Serial Communication Parameters
Data Bits:
Stop Bits:
Parity: None, Even, Odd, Space, Mark
Flow Control:
Baudrate:
Pull High/Low Resistor for RS
Serial Signals
RS
RS
RS
RS
Memory Expansion Slot
Slot Type:
Software
Network Protocols: ICMP, IPv4/v6, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1/V2c/V3, HTTP, SMTP,
ARP, PPPoE
Security Protocols:
Configuration Options:
Windows Real COM Drivers:
x86/x64,
2012 x64, Embedded CE 5.0/6.0, XP Embedded
Fixed TTY Drivers:
Solaris 10, FreeBSD, AIX 5.x
Linux Real TTY Drivers:
Management:
IP Routing:
Operation Modes
Standard:
Ethernet Modem, Printer, PPP, Disabled
Secure: Secure Real COM, Secure TCP Server, Secure TCP Client, Secure Pair Connection, SSH, Reverse SSH
Applications
Terminal Sessions:
Physical Characteristics
Housing:
Weight:
Dimensions:
Without ears: 77 x 111
With ears: 89 x 111 x 28 mm (3.50 x 4.37 x 1.1 in)
Environmental Limits
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models:
Storage Temperature:
Ambient Relative Humidity:
Power Requirements
Input Voltage:
2
RS-232/422/485
DB9 male
-485 Data Direction Control: ADDC® (Automatic Data Direction Control)
Serial port 1 doubles as RS-232 console port
5, 6, 7, 8
1, 1.5, 2
RTS/CTS, DTR/DSR, XON/XOFF, RTS Toggle
50 bps to 921.6 kbps (supports nonstandard baudrates)
-485: 1 KΩ, 150 KΩ
-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-422: Tx+, Tx-, Rx+, Rx-, GND
-485-4w: Tx+, Tx-, Rx+, Rx-, GND
-485-2w: Data+, Data-, GND
SD socket (supports up to 2 GB)
, HTTPS
SSLv3, TLSv1.0/1.1/1.2
Web Console, Serial Console, Telnet Console, Windows Search Utility
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/10
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6,
Linux kernel 2.4.x, 2.6.x, 3.x
SNMP MIB-II
Static, RIP-I, RIP-II
Real COM, TCP Server, TCP Client, UDP, Pair Connection, RFC2217, Terminal, Reverse Telnet,
8 sessions per port
Metal
730 g (1.61lb)
x 28 mm (3.30 x 4.37 x 1.1 in)
-40 to 75°C (-40 to 167°F)
-20 to 75°C (-4 to 167°F)
5 to 95% (noncondensing)
12 to 48 VDC
NPort 6000 Series Introduction
1-8
Input Current:
NPort 6250: 333 mA @ 12 V
NPort 6250
NPort 6250
Alarm
Power Line Protection:
Standards and Certifications
Safety:
EMC:
EMI: CISPR 22, FCC Part 15B Class A
EMS:
IEC 61000
IEC 61000
IEC 61000
IEC 61000
IEC 61000
IEC 61000
Freefall:
Vibration:
Green Product: RoHS, CRoHS, WEEE
Reliability
Alert Tools:
Automatic Reboot Trigger:
MTBF (mean time between failures)
Time:
NPort 6250: 1,947,486 hrs
NPort 6250 Multi
NPort 6250 Single
Standard:
Warranty
Warranty Period:
Details:
Ethernet Interface
Number of Ports:
Speed:
Connector:
Magnetic Isolation:
Optical Fiber Interface (with network module)
Fiber Port:
Distance:
Single-mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))
Min. TX Output:
Max. TX Output:
Sensitivity:
Serial Interface
Number of Ports:
Serial Standards:
DC
-M-SC: 428 mA @ 12 VDC
-S-SC: 376 mA @ 12 VDC
Contact: Relay output with current-carrying capacity of 1 A @ 24 VDC
1 KV burst (EN61000-4-4: EFT/B), 0.5 KV surge (EN61000-4-5)
UL 60950-1
55022/24
-4-2 ESD: Contact: 4 kV; Air: 8 kV
-4-3 RS: 80 MHz to 1 GHz: 3 V/m
-4-4 EFT: Power 1 kV; Signal 0.5 kV
-4-5 Surge: Power 1 kV; Signal: 1 kV
-4-6 CS: 150 kHz to 80 MHz, 3 V/m; Signal: 3 V/m
-4-8 PFMF IEC 61000-4-11 DIPs
IEC-68-2-6, IEC-68-2-34, IEC-68-2-32
IEC-68-2-6, IEC-68-2-34
See www.moxa.com/warranty

NPort 6450

10/100 Mbps, auto MDI/MDIX
Built-in buzzer and RTC (real-time clock)
Built-in WDT (watchdog timer)
-mode fiber: 1,092,794 hrs
-mode fiber: 1,477,682 hrs
Telcordia (Bellcore) Standard TR/SR
5 years
1
8-pin RJ45
1.5 KV built-in
100BaseFX, SC connector
Multimode: 0 to 4 km, 1300 nm (62.5/125 µm, 500 MHz*km)
Multimode: -20 dBm
Single-mode: -5 dBm
Multimode: -10 dBm
Single-mode: 0 dBm
Multimode: -34 to -30 dBm
Single-mode: -36 to -32 dBm
4
RS-232/422/485
NPort 6000 Series Introduction
1-9
Connector:
RS
Console Port:
Serial Communication Parameters
Data Bits:
Stop Bits:
Parity: None, Even, Odd, Space, Mark
Flow Control:
Baudrate:
Pull High/Low Resistor for RS
Serial Signals
RS
RS
RS
RS
Memory Expansion Slot
Slot Type:
Software
Network Protocols: ICMP, IPv4/v6, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1/V2c/V3, HTTP, SMTP,
ARP, PPPoE
Security Protocols:
Configuration Options:
Windows Real COM Drivers:
x86/x64,
2012 x64, Embedde
Fixed TTY Drivers:
Solaris 10, FreeBSD, AIX 5.x
Linux Real TTY Drivers:
Management:
IP Routing:
Operation Modes
Standard:
Ethernet Modem, Printer, PPP, Disabled
Secure: Secure Real COM, Secure TCP Server, Secure TCP Client, Secure Pair Connection, SSH, Reverse SSH
Applications
Terminal Sessions:
Physical Characteristics
Housing:
Weight:
Dimensions:
Without ears: 158 x 103 x 35 mm (6.22 x 4.06 x 1.38 in)
With ears: 181 x 103 x 35 mm (7.13 x 4.06 x 1.38 in)
Environmental Limits
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models:
Storage
Ambient Relative Humidity:
Power Requirements
Input Voltage:
Input Current:
Alarm Contact:
Power Line Protection: 1 KV burst (EN61000-4-4: EFT/B), 1 KV surge (EN61000-4-5)
DB9 male
-485 Data Direction Control: ADDC® (Automatic Data Direction Control)
Serial port 1 doubles as RS-232 console port
5, 6, 7, 8
1, 1.5, 2
RTS/CTS, DTR/DSR, XON/XOFF, RTS Toggle
50 bps to 921.6 kbps (supports nonstandard baudrates)
-485: 1 KΩ, 150 KΩ
-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-422: Tx+, Tx-, Rx+, Rx-, GND
-485-4w: Tx+, Tx-, Rx+, Rx-, GND
-485-2w: Data+, Data-, GND
SD socket (supports up to 2 GB)
, HTTPS
SSLv3, TLSv1.0/1.1/1.2
Web Console, Serial Console, Telnet Console, Windows Search Utility
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/10
d CE 5.0/6.0, XP Embedded
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6,
Linux kernel 2.4.x, 2.6.x, 3.x
SNMP MIB-II
Static, RIP-I, RIP-II
Real COM, TCP Server, TCP Client, UDP, Pair Connection, RFC2217, Terminal, Reverse Telnet,
8 sessions per port
Metal, IP30 protection
1020 g (2.25 lb)
-40 to 75°C (-40 to 167°F)
Temperature: -20 to 75°C (-4 to 167°F)
5 to 95% (noncondensing)
12 to 48 VDC
730 mA @ 12 VDC
Relay output with current-carrying capacity of 1 A @ 24 VDC
NPort 6000 Series Introduction
1-10
Standards and Certifications
Safety:
EMC:
EMI:
EMS:
IEC 61000
IEC 61000
IEC 61000
IEC 61000
IEC 61000
IEC 61000
Freefall:
Vibration:
Green Product:
Reliability
Alert Tools:
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
MTBF
Time:
Standard:
Warranty
Warranty Period:
Details: See www.moxa.com/warranty
Ethernet Interface
Number of Ports:
Speed: 10/100 Mbps, auto MDI/MDIX
Connector:
Magnetic Isolation:
Optical Fiber Interface (with network module)
Serial Interface
Number of Ports:
Serial Standards:
NPort 6610:
NPort 6650: RS
Connector:
RS
Console Port:
Serial Communication Parameters
Data Bits:
UL 60950-1
55022/24
CISPR 22, FCC Part 15B Class A
-4-2 ESD: Contact: 4 kV; Air: 8 kV
-4-3 RS: 80 MHz to 1 GHz: 3 V/m
-4-4 EFT: Power 1 kV; Signal 0.5 kV
-4-5 Surge: Power 1 kV; Signal: 1 kV
-4-6 CS: 150 kHz to 80 MHz, 3 V/m; Signal: 3 V/m
-4-8 PFMF IEC 61000-4-11 DIPs
IEC-68-2-6, IEC-68-2-34, IEC-68-2-32
IEC-68-2-6, IEC-68-2-34
RoHS, CRoHS, WEEE
Built-in buzzer and RTC (real-time clock)
(mean time between failures)
850,905 hrs
Telcordia (Bellcore) Standard TR/SR
5 years

NPort 6610/6650

1
8-pin RJ45
1.5 kV built-in
Wavelength 1300 nm 1310 nm
Max. TX -10 dBm 0 dBm
Min. TX -20 dBm -5 dBm
RX Sensitivity -34 to -30 dBm -36 to -32 dBm
Link Budget 12 dB 29 dB
Typical Distance 4 kma 40 kmb
Saturation -6 dBm -3 dBm
a. 62.5/125 µm, 500 MHz*km fiber-optic cable
b. 9/125 µm, 3.5 PS/(nm*km) fiber-optic cable
-485 Data Direction Control: ADDC® (Automatic Data Direction Control)
5, 6, 7, 8
100BaseFX
Multimode Single-mode
8, 16, or 32
RS-232
-232/422/485
8-pin RJ45
Dedicated RS-232 console port on rear panel (8-pin RJ45)
NPort 6000 Series Introduction
1-11
Stop Bits:
Parity:
Flow Control:
Baudrate:
Pull High/Low Resistor for RS
Terminator for
Serial Signals
RS
RS
RS
RS
Memory Expansion Slot
Slot Type:
Software
Network Protocols: ICMP, IPv4/v6, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1/V2c/V3, HTTP, SMTP,
ARP, PPPoE
Security Protocols:
Configuration Options: Web Console, Serial Console, Telnet Console, Windows Search Utility
Windows Real COM Drivers:
(x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Fixed TTY Drivers: SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x,
HP
Linux Real TTY Drivers: Linux 2.4.x, 2.6.x, 3.x
Management:
IP Routing:
Operation Modes
Standard:
Ethernet Modem, Printer, PPP, Disabled
Secure: Secure Real COM, Secure TCP Server, Secure TCP Client, Secure Pair Connection, SSH, Reverse SSH
Applications
Terminal Sessions:
Physical Characteristics
Housing:
Weight:
NPort 6600
NPort 6600
NPort 6600
Dimensions:
Without ears: 440 x 195 x 44 mm (17.32 x 7.68 x 1.73 in)
With ears: 480 x 195 x 44 mm (18.9 x 7.68 x 1.73 in)
Environmental Limits
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models:
High
Storage
Standard Models:
Wide Temp. Models:
High
Ambient Relative Humidity:
1, 1.5, 2
None, Even, Odd, Space, Mark
RTS/CTS, DTR/DSR, XON/XOFF, RTS Toggle
50 bps to 921.6 kbps (supports nonstandard baudrates)
-485: 1 kΩ, 150 kΩ
RS-485: 120 Ω
-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-422: Tx+, Tx-, Rx+, Rx-, GND
-485-4w: Tx+, Tx-, Rx+, Rx-, GND
-485-2w: Data+, Data-, GND
SD socket (supports up to 2 GB)
, HTTPS
SSLv3, TLSv1.0/1.1/1.2
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10
-UX 11i, Mac OS X
SNMP MIB-II
Static, RIP-I, RIP-II
Real COM, TCP Server, TCP Client, UDP, Pair Connection, RFC2217, Terminal, Reverse Telnet,
8 sessions per port
Metal
-8: 3460 g (7.63 lb)
-16: 3580 g (7.89 lb)
-32: 3600 g (7.94 lb)
-40 to 75°C (-40 to 167°F)
-voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Temperature:
-40 to 75°C (-40 to 167°F)
-40 to 75°C (-40 to 167°F)
-voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
5 to 95% (noncondensing)
NPort 6000 Series Introduction
1-12
Power Requirements
Input Voltage:
AC Models: 100 to 240 VAC
DC Models:
Input Current:
AC Models:
DC Models:
Alarm Contact:
Power Line Protection:
Standards and Certifications
Safety:
EMC: 55022/24
EMI:
EMS:
NPort 6600
NPort 6600 48V models:
NPort 6650 HV models:
Freefall:
Vibration:
Green Product:
Reliability
Alert Tools:
Automatic Reboot Trigger:
140 mA @ 100 VAC (8 ports)
192 mA @ 100 VAC (16 ports)
285 mA @ 100 VAC (32 ports)
293 mA @ 48 VDC
200 mA @ 88 VDC
UL 60950-1
CISPR 22, FCC Part 15B Class A
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power 1 kV; Signal 0.5 kV
IEC 61000-4-5 Surge: Power 2kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz, 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power 1 kV; Signal 0.5 kV
IEC 61000-4-5 Surge: Power 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz, 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power 4 kV; Signal 2 kV
IEC 61000-4-5 Surge: Power 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz, 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
IEC-68-2-6, IEC-68-2-34, IEC-68-2-32
±48 VDC (20 to 72 VDC, -20 to -72 VDC), 110 VDC (88 to 300 VDC)
Relay output with current-carrying capacity of 1 A @ 24 VDC
1 kV burst (EN 61000-4-4: EFT/B), 0.5 kV surge (EN 61000-4-5)
-8/16/32:
IEC-68-2-6, IEC-68-2-34
RoHS, CRoHS, WEEE
Built-in buzzer and RTC (real-time clock)
Built-in WDT (watchdog timer)
NPort 6000 Series Introduction
1-13
MTBF (mean time between failures)
Time:
NPort 6610
NPort 6610
NPort 6610
NPort 6650
NPort 6650
NPort 6650
NPort 6650
NPort 6650
NPort 6650
Standard:
Warranty
Warranty Period:
Details:
-8: 135,891 hrs
-16: 102,373 hrs
-32: 68,707 hrs
-8: 636,600 hrs
-16: 439,673 hrs
-32: 310,078 hrs
-8-HV-T: 501,171 hrs
-16-HV-T: 380,006 hrs
-32-HV-T: 290,914 hrs
Telcordia (Bellcore) Standard TR/SR
5 years
See www.moxa.com/warranty
2

2. Getting Started

This chapter covers the hardware installation of the NPort 6000. Software installation is covered in the next
chapter.
The following topics are covered in this chapter:
Panel Layout
NPort 6150/6250
NPort 6450
NPort 6610/6650
Panel, DIN-Rail, and Rack-Mounting
Connecting the Hardware
Wiring Requirements
Connecting the NPort 6600 VDC’s Power
Grounding the NPort 6600 VDC
Connecting to the Network
Connecting to a Serial Device
LED Indicators
Adjustable Pull High/Low Resistors for the RS-485 Port
NPort 6000 Series Getting Started
2-2
NPort 6150
NPort 6250

Panel Layout

NPort 6150/6250

NPort 6450

Note: The LCD panel is only available with standard temperature models.
NPort 6000 Series Getting Started
2-3

NPort 6610/6650

NPort 6000 Series Getting Started
2-4
The NPort 6150, 6250, and 6450 device servers have built-in “ears” for attaching the device
server to a wall or the inside of a cabinet. We suggest using two screws per ear to attach the
device servers to a wall or the inside of a cabinet. The heads of the screws should be less than
6.0 mm in diameter, and the shafts should be less than 3.5 mm in diameter, as shown in the
figure at the right.

Panel, DIN-Rail, and Rack-Mounting

Wall or Cabinet Mounting

NPort 6150 NPort 6250 NPort 6450

DIN-Rail Mounting

DIN-rail attachments can be purchased separately to attach the NPort 6150, 6250, and 6450 to a DIN-rail.
When snapping the attachments to the DIN-rail, make sure that the stiff metal springs are at the top.
NPort 6150 NPort 6250 NPort 6450

Rack-Mounting

Use four screws to attach the NPort 6610/6650 to a standard rack.
NPort 6610/6650
NPort 6000 Series Getting Started
2-5
ATTENTION
Disconnect the power before installing and wiring
Disconnect the power cord before installing and/or wiring your NPort 6000.
Do not exceed the maximum current for the wiring
Determine the maximum possible current for each power wire and common wire. Observe all electrical codes
dictating the maximum current allowable for each wire size.
If the current exceeds the maximum rating, the wiring could overheat, causing serious damage to your
equipment.
Server may get hot
Use caution when handling the NPort 6000 after it has been plugged in. The internal components generate
hea
can still operate even
NOTE
You should use 8 kg
14 AWG of suitable electric wire to connect the NPort 6600
V

Connecting the Hardware

This section describes how to connect the NPort 6000 to serial devices for the first time.

Wiring Requirements

; use caution when handling
t, and the casing may get too hot to touch.
You should also heed the following guidelines:
• Use separate paths to route wiring for power and devices. If power-wiring and device-wiring paths must
cross, make sure the wires are perpendicular at the intersection point.
NOTE: Do not run signal or communication wiring and power wiring in the same wire conduit. To avoid
interference, wires with different signal characteristics should be routed separately.
• The type of signal transmitted through a wire should determine which wires should be kept separate. The
rule of thumb is that wires sharing similar electrical characteristics may be bundled together.
• Keep input wiring and output wiring separate.
• It is good practice to label the wiring to all devices in the system.

Connecting the NPort 6600 VDC’s Power

To connect the NPort 6600-32/16/8-48V’s power cord with its terminal block, follow the steps given below:
Loosen the screws on the V+ and V- terminals of the NPort 6600 VDC’s terminal
block.
Connect the power cord’s VDC wire to the terminal block’s V+ terminal and the
If the power is properly supplied, the “Ready” LED will glow solid red until the system is ready, at which time
the “Ready” LED will change to green.
DC’s power cord to its terminal block.
power cord’s DC Power Ground wire to the terminal block’s V- terminal; then,
tighten the terminal block screws. (Note: The NPort 6600 VDC
if the DC and DC Power Ground are reversed.)
-cm of screw torque and 22-
NPort 6000 Series Getting Started
2-6
The Shielded Ground (sometimes called Protected Gro
contact from the right of the 5-pin power terminal block connector located on the rear
panel of the NPort 6600
ATTENTION
This product is intended to
not
Off
The serial port is not opened by server-side software.

Grounding the NPort 6600 VDC

Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the
ground connection from the ground screw to the grounding surface before connecting devices.
und) contact is the second
VDC. Connect the SG wire to the earth ground.
be mounted to a well-grounded mounting surface such as a metal panel.

Connecting to the Network

Connect one end of the Ethernet cable to the NPort 6000’s 10/100M Ethernet port and the other end of the
cable to the Ethernet network. If you are using a fiber-port version of the NPort 6000, connect the fiber cable
from the Ethernet network to the NPort 6000’s fiber port.
If the cable is properly connected, the NPort 6000 will indicate a valid connection to the Ethernet as follows:
• The Ethernet LED glows solid green when connected to a 100 Mbps Ethernet network.
• The Ethernet LED glows solid orange when connected to a 10 Mbps Ethernet network.
• The Ethernet LED flashes when Ethernet packets are being transmitted or received.

Connecting to a Serial Device

Connect the serial data cable between the NPort 6000 and the serial device. Serial data cables are available as
optional accessories.

LED Indicators

The LED indicators on the front panel of the NPort 6000 are described in the following table.
LED Name LED Color LED Function
PWR Red Power is being supplied to the power input.
Ready Red Steady on: Power is on, and the NPort 6000 is booting up.
Blinking: An IP conflict occurs, or the DHCP or BOOTP server does
respond properly.
Green Steady on: Power is on, and the NPort 6000 is functioning normally.
Blinking: The device server has been located by NPort Search Utility.
Off Power is off, or there is a power error condition.
Link Orange The NPort 6000 is connected to a 10-Mbps Ethernet connection.
Green The NPort 6000 is connected to a 100-Mbps Ethernet connection.
Off The Ethernet cable is disconnected or has a short.
P1 to P16 in-use LED Green The serial port is opened by server-side software.
P1, P2, P3, P4
(6150/6250/6450)
P1 to P16 Tx
(6610/6650)
Orange The serial port is receiving data.
Green The serial port is transmitting data.
Off No data is being transmitted or received through the serial port.
Green The serial port is transmitting data.
Off Data is not being transmitted through the serial port.
NPort 6000 Series Getting Started
2-7
Steady on: The NPort 6000 device server is connected to an Ethernet
Ω
Ω
ATTENTION
Do not use the 1 K
232 interface. Doing so will degrade the
RS
NPort 6150
NPort 6250
LED Name LED Color LED Function
P1 to P16 Rx
(6610/6650)
The NPort 6450 and 6650 models have additional LEDs for the alarm and optional network modules:
LED Name LED Color LED Function
Module
(6450/6610/6650)
Link (on optional
network modules
NM-FX01-M-SC,
NM-FX01-S-SC)
Alarm
(6450/6610/6650)
Orange The serial port is receiving data.
Off No data is being received through the serial port.
Green The fiber-optic network module is plugged in and has been detected.
Off The fiber-optic network module is not present.
Orange
fiber connection, but the port is idle.
Blinking: The fiber port is transmitting or receiving data.
Red The relay output (DOUT) is open (exception).
Off The relay output (DOUT) is short (normal condition).

Adjustable Pull High/Low Resistors for the RS-485 Port

In some critical environments, you may need to add termination resistors to prevent the reflection of serial
signals. When using termination resistors, it is important to set the pull high/low resistors correctly so that the
electrical signal is not corrupted. The NPort 6000 uses jumper settings or DIP switches to set the pull high/low
resistor values for each serial port.
To set the pull high/low resistors to 150 K
are not shorted by jumper caps. (For the NPort 6650, make sure both of the assigned DIP switches are in the
OFF position.) This is the default setting.
To set the pull high/low resistors to 1 K
shorted by jumper caps. (For the NPort 6650, make sure both of the assigned DIP switches are in the ON
position.)
-232 signals, shorten the maximum allowed communication distance, and the Rx LED may light up.
setting on the NPort 6000 when using the RS-
, make sure that the two jumpers assigned to the serial port
, make sure that the two jumpers assigned to the serial port are
NPort 6150/6250/6450 Jumpers
NPort 6000 Series Getting Started
2-8
NPort 6450
NPort 6650 DIP Switches
SW
ON
OFF
1 2 3
Pull High Pull Low Terminator
1 K 1 K 120
150 K 150 K
3

3. Initial IP Address Configuration

When setting up the NPort 6000 for the first time, the first thing you should do is configure its IP address. This
chapter introduces the different methods that can be used.
The following topics are covered in this chapter:
Static and Dynamic IP Addresses
Factory Default IP Address
Configuration Options
Device Search Utility
Web Console
LCM Console/Front Panel (NPort 6610, 6650, and 6450 only)
ARP
Telnet Console
Serial Console
NPort 6000 Series Initial IP Address Configuration
3-2
ATTENTION
Consult your network administrator on how to reserve a fixed IP address for your NPort 6000 in the MAC-IP
mapping table when using a DHCP Server or BOOTP Server. For most applications, you should assign a fixed
IP address to your NPort 6000.

Static and Dynamic IP Addresses

Determine whether your NPort 6000 needs to use a static IP or dynamic IP address (either DHCP or
BOOTP/PPPoE application).
If your NPort 6000 is used in a static IP environment, you will assign a specific IP address, using one
of the tools described in this chapter.
If your NPort 6000 is used in a dynamic IP environment, the IP address will be assigned
automatically from over the network. In this case, set the IP configuration mode to DHCP, DHCP/BOOTP,
BOOTP, or PPPoE.

Factory Default IP Address

The NPort 6000 is configured with the following default private IP address:
192.168.127.254
Note that IP addresses that begin with “192.168” are referred to as private IP addresses. Devices configured
with a private IP address are not directly accessible from a public network. For example, you would not be able
to ping a device with a private IP address from an outside Internet connection. If your application requires
sending data over a public network, such as the Internet, your NPort 6000 will need a valid public IP address,
which can be leased from a local ISP.

Configuration Options

Device Search Utility

You may configure your NPort 6000 with the bundled Device Search Utility for Windows. Note that you will be
asked to enter the user
name and password to access the NPort 6000 device. The default username is admin and the default password
is moxa. Please refer to Chapter 13, Software Installation/Configuration, for details on how to install and use
the Device Search Utility.

Web Console

You may configure your NPort 6000 using a standard web browser. Note that you will be asked to enter the
username and password to access the NPort 6000 device. The default username is admin and the default
password is moxa. Please refer to Chapter 5, Configuration with the Web Console, for details on how to access
and use the NPort 6000 web console.

LCM Console/Front Panel (NPort 6610, 6650, and 6450 only)

The NPort 6610, 6650, and 6450 only give you the option to configure some settings through the front panel,
also known as the LCM (Liquid Crystal Module) console. The LCM console can be configured for read-only or
writeable access. Read-only access allows settings to be viewed but not changed. Factory default settings are
NPort 6000 Series Initial IP Address Configuration
3-3
ATTENTION
If the
name
and
configured for read
NOTE
Only standard temperature models come with an LCM console.
ATTENTION
In order to use the ARP setup method, both your computer and the NPort 6000 must be connected to the
same LAN. Alternatively, you may use a crossover Ethernet cable to connect the NPort 6000 directly to your
computer’s Ethernet card. Before executing the ARP command, your NPort 6000 must be configured with the
factory default IP address (192.168.127.254)
r computer and the NPort 6000 must be on the same
subnet.
for writeable access, where configuration is allowed through the LCM console to users in thevAdministration
Group only. (For account management details, please reference Chapter 10. Administration Settings)
LCM console is configured for writeable status, the LCM console will require you to enter the user
the password before allowing you access. The password will not be required if the LCM console is
-only access.
The MENU button activates the main menu. It is also used to cancel a selection and return to a previous menu.
The UP and DOWN buttons navigate between available options.
The SEL button confirms a selection or enters a submenu.
The IP environment (Static, DHCP, PPPoE, etc.) is configured under Main Menu Network setting IP
config. The IP address is configured under Main Menu Network setting IP address. After the address
has been entered, you will need to restart the NPort under Main Menu Save/Restart.
The following instructions explain how to set the NPort 6000’s IP address through the LCM console:
1. Press MENU to activate the Main Menu.
2. The first line of the display indicates the current menu and should read Main Menu. The second line
indicates the current selection and should read Server setting. Use the UP and DOWN buttons to select
Network setting. Press SEL to enter the Network setting menu.
3. In the Network setting menu, select IP config. Don’t forget to press SEL to confirm your selection.
4. In the IP config menu, use the UP and DOWN buttons to select the option that matches your IP
environment (Static, DHCP, etc.). Press SEL to confirm your choice. You may also press MENU to cancel
your selection and return to the previous submenu.
5. You should be back in the Network setting menu. From the Network setting menu, select IP address.
6. Use the UP and DOWN buttons to modify the digit currently selected by the blinking cursor. Press SEL to
move to the next digit. Continue modifying the IP address until all the digits have been entered. If you make
a mistake, press MENU to cancel all changes and return to the Network setting menu. You cannot go back
one digit.
7. Once you have finished modifying the IP address, your changes are saved but not in effect. In order for your
changes to take effect, you will need to restart the NPort. You may view and modify your changes by
selecting IP address at the Network setting menu again.
8. Press the menu button to exit the Network setting menu and return to the Main Menu. Use the UP and
DOWN buttons to select Save/Restart and press SEL. Use the UP and DOWN buttons to select Yes and
press SEL to restart.
ARP
You may use the ARP (Address Resolution Protocol) command to set up an IP address for your NPort 6000. The
ARP command tells your computer to associate the NPort 6000’s MAC address with an IP address. Afterwards,
use Telnet to access the NPort 6000, and its IP address will be reconfigured.
, and you