Welcome to the MOXA NPort 5600 Series. NPort 5610-16/8 has 16 or 8 RS-232 ports, NPort 5630-16/8 has 16 or 8 RS-422/485 ports, and NPort 5650-16/8 have 16 or 8 RS-232/422/485 ports.
2. Package Checklist
The NPort 5600 package should contain the following items:
y 1 16-port or 8-port serial device server y NPort Documentation & Software CD y NPort 5600 Quick Installation Guide y Power cord (included with AC version of the product)
Optional Accessories
y CBL-RJ45M9-150: y CBL-RJ45F9-150: y CBL-RJ45M25-150: y CBL-RJ45F25-150:
8-pin RJ45 to Male DB9 cable, 150 cm 8-pin RJ45 to Female DB9 cable, 150 cm 8-pin RJ45 to Male DB25 cable, 150 cm 8-pin RJ45 to Female DB25 cable, 150 cm
Notify your sales rep if any of the above items are missing or damaged.
3. Hardware Introduction
The NPort 5600 Series has 12 models: NPort 5610-16, NPort 5610-8, NPort 5610-16-48V, NPort 5610-8-48V, NPort 5630-16, NPort 5630-8, NPort 5650-8, NPort 5650-16, NPort 5650-8-M-SC, NPort 5650-16-M-SC, NPort 5650-8-S-SC, and NPort 5650-16-S-SC. The front and rear panels are shown below:
Front panel of NPort 5600 Series
5610-
16
Rear panel of NPort 5610/5630/5650 (AC Power)
LAN
Serial ports
ACPOWER100-240V, 47-63Hz
12345678
910111213141516
Rear panel of NPort 5650 (Fiber Model)
Serial ports
Link
Fiber
ACPOWER100-240V, 47-63Hz
12345678
910111213141516
Rear panel of NPort 5610-16-48V (DC Power)
LAN
Serial ports
12345678
910111213141516
V+ V-
ON OFF
Reset Button—Press the Reset button continuously for 5 sec to load factory defaults: Use a pointed object to press the reset button. Release
the button after the Ready LED stops blinking. LED Indicators on the Front Panel
The front panels of NPort 5600 have several LED indicators, as described in the following table.
LED Name LED Color LED Function
Off Power is off, or power error condition exists.
Steady on: Power is on and NPort is
booting up.
Red
Blinking: Indicates an IP conflict, or that
DHCP or BOOTP server did not respond properly.
Steady on: Power is on and NPort is
functioning normally.
Ready
Green
Blinking: The NPort has been located by
NPort Administrator’s Location function.
Orange Serial port is receiving data.
Green Serial port is transmitting data.
1-16
Off
No data is being transmitted or received through the serial port.
LCM Display Panel—If the NPort is working properly, the LCM panel will be colored green. The red Ready LED will also light up, indicating that the NPort is receiving power. After the red Ready LED turns green, you will see a display similar to:
N P 5 6 1 0 - 1 6 _ 3 8 1 9 2 . 1 6 8 . 1 2 7 . 2 5 4
y NP5610-16 is the NPort’s name y 38
is the NPort’s serial number
y 192.168.127.254 is the NPort’s IP address
LCM Panel Operation—There are four buttons on NPort 5600’s front panel. These buttons are used to operate the server’s LCM panel. Going from left to right, the buttons are:
Button Action
MENU
Activates the main menu, or returns to an upper level. Scrolls up through a list of items shown on the LCM panel’s second line. Scrolls down through a list of items shown on the LCM panel’s second line.
SEL
Selects the option listed on the LCM panel’s second line.
Detailed LCM Panel Operating instructions can be found on the CD-ROM in the NPort 5600 Series User’s Manual.
Link Indicator on the Rear Panel of NPort 5650 Fiber Model
The rear panels of NPort 5600 have a link indicator, as described in the following table.
LED Name LED Color LED Function
Off Fiber is disconnected
Green
Fiber is connected and no data is being transmitted
Link
Blinking
Fiber is connected and data is being transmitted
4. Hardware Installation Procedure
STEP 1: After removing NPort 5600 from the box, the first thing you
should do is attach the power adaptor. STEP 2: Connecting the Power AC: Connect the NPort 5610/5630/5650 100 to 240 VAC power cord to
the AC connector. If the power connection is correct, the “Ready” LED will glow solid red until the system is ready, at which time the “Ready” LED will change to green.
DC: Connect NPort 5610-16/8-48V’s power cord to the DC connector,
and then perform the following:
V+ V-
ON OFF
1. Loosen the screws on the V+ and V- terminals of
NPort 5610-16/8-48V’s terminal block.
2. Connect the power cord’s 48 VDC or -48 VDC
wire to the terminal block’s V
+
terminal, and the power cord’s DC Power Ground wire to the terminal block’s V
-
terminal, and then tighten the terminal block screws. (Note: NPort 5610-16/8-48V can still operate even if the 48V/-48V and DC Power Ground are reversed.)
If the power is connected properly, the “Ready” LED will glow a solid red until the system is ready, at which time the “Ready” LED will change to green.
Grounding NPort 5610-16/8-48V:
V+ V-
SG
ON OFF
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices. The Shielded Ground (sometimes called Protected Ground) contact is the second contact from the right of the 5-pin power terminal block connector located on the rear panel of NPort 5610-16/8-48V. Connect the SG wire to the Earth ground.
STEP 3: Connect NPort 5600 to a network. Use a standard straight-through Ethernet cable to connect to a Hub or Switch. When setting up or testing NPort 5600, you might find it convenient to connect directly to your computer’s Ethernet port. In this case, use a cross-over Ethernet cable.
STEP 4: Connect NPort 5600’s serial port to a serial device. Placement Options: You can place NPort 5600 on a desktop or other
horizontal surface.
P/N: 1802056000200
— 4 — — 5 — — 6 —
5. Software Installation Information
To install NPort Administration Suite, insert the NPort Document & Software CD into your computer’s CD-ROM drive. Once the NPort Installation CD window opens, click the INSTALL UTILITY button,
and then follow the instructions on the screen. To view detailed information about NPort Administration Suite, click
the DOCUMENTS button, and then select “NPort 5600 Series User’s Manual” to open the pdf version of this user’s guide.
6. Pin Assignments and Cable Wiring
Serial Port Pinouts for NPort 5610
Serial Port Pinouts for NPort 5630
18
18
Pin RS-232
1 DSR (in) 2 RTS (out) 3 GND 4 TxD (out) 5 RxD (in) 6 DCD (in) 7 CTS (in) 8 DTR (out)
Pin
RS-422
4-wire RS-485
2-wire RS-485
1 --- --­2 --- --­3 TxD+ --­4 TxD- --­5 RxD- Data­6 RxD+ Data+ 7 GND GND 8 --- ---
Serial Port Pinouts for NPort 5650
Pin RS-232
RS-422
4-wire RS-485
2-wire
RS-485
1 DSR --- --­2 RTS TxD+ --­3 GND GND GND 4 TxD TxD- --­5 RxD RxD+ Data+ 6 DCD RxD- Data­7 CTS --- --­8 DTR --- ---
18
Serial Cables for NPort 5630 (2-wire RS-485)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5630
Serial Device
Data- 5
2 3 3 2 Data-
Data+ 6
1 1 8 8 Data+
GND 7
8 7 5 4 GND
Serial Cables for NPort 5630 (RS-422/4-wire RS-485)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5630
Serial Device
TxD+ 3
5 5 7 7 RxD+
TxD- 4
3 2 2 3 RxD-
RxD- 5
2 3 3 2 TxD-
RxD+ 6
1 1 8 8 TxD+
GND 7
8 7 5 4 GND
Serial Cables for NPort 5610/5650 (RS-232)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5610 NPort 5650
Serial Device
DSR 1
6 4 6 20 DTR
RTS 2
7 8 4 5 CTS
GND 3
5 5 7 7 GND
TxD 4
3 2 2 3 RxD
RxD 5
2 3 3 2 TxD
DCD 6
1 1 8 8 DCD
CTS 7
8 7 5 4 RTS
DTR 8
4 6 20 6 DSR
Serial Cables for NPort 5650 (RS-422/4-wire RS-485)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5650
Serial Device
TxD+ 2
7 8 4 5 RxD+
GND 3
5 5 7 7 GND
TxD- 4
3 2 2 3 RxD-
RxD+ 5
2 3 3 2 TxD+
RxD- 6
1 1 8 8 TxD-
Serial Cables for NPort 5650 (2-wire RS-485)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5650
Serial Device
GND 3
5 5 7 7 GND
Data+ 5
2 3 3 2 Data+
Data- 6
1 1 8 8 Data-
7. Environmental Specifications
LAN
Ethernet Protection
10/100 Mbps, RJ45 Built-in 1.5 KV magnetic isolation
Optical Fiber
Multi mode Single mode
Distance 0 to 2 km, 1310 nm
(62.5/125 μm, 500 MHz*km)
0 to 40 km, 1310 nm (9/125 μm, 3.5 PS/ (nm*km))
Min. TX Output -20 dBm 0 to 40 km, -5 dBm Max. TX Output -14 dBm 0 to 40 km, 0 dBm Sensitivity -34 to -30 dBm -36 to -32 dBm
Serial Interface
Interface No. of Ports Port Type Signals (RS-232) Signals (RS-422) Signals (2-wire RS-485) Signals (4-wire RS-485) Serial Line Protection RS-485 Data Direction
RS-232/422/485 16/8 8-pin RJ45 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND Tx+, Tx-, Rx+, Rx­Data+, Data-, GND Tx+, Tx-, Rx+, Rx­15 KV ESD for all signals ADDC™ (Automatic Data Direction Control)
Power requirements
Power Input
Power Consumption
NPort 5610-8/16 NPort 5610-8/16-48V NPort 5630-8/16 NPort 5650-8/16 NPort 5650-S-SC-8/16 NPort 5650-M-SC-8/16
100 to 240 VAC, 47 to 63 Hz, ±48 VDC (38 to 72 VDC, -38 to -72 VDC)
141 mA @ 100 VAC, 93 mA @ 240 VAC 135 mA @ 48 VDC 152 mA @ 100 VAC, 98 mA @ 240 VAC 158 mA @ 100 VAC, 102 mA @ 240 VAC 164 mA @ 100 VAC, 110 mA @ 240 VAC
174 mA @ 100 VAC, 113 mA @ 240 VAC Operating temp. 0 to 55°C (32 to 131°F) Operating humidity 5 to 95% RH Dimensions (W×D×H) 190 × 44.5 × 478 mm (including ears)
190 × 44.5 × 440 mm (without ears) Serial line protection 15 KV ESD for all signals Magnetic isolation 1.5 KV for Ethernet Power line protection 4 KV Burst (EFT), EN61000-4-4
2 KV Surge, EN61000-4-5 Regulatory approvals FCC Class A, CE Class A, UL, CUL, TÜV
Copyright © 2006
Moxa Technologies Co., Ltd.
All rights reserved.
Reproduction without permission is prohibited.
Tel: +886-2-8919-1230
www.moxa.com
Fax: +886-2-8919-1231
support@moxa.com.tw
Loading...