Moxa Technologies NPort 5110 User Manual

4.3 (3)

NPort 5110 Series User’s Manual

First Edition, December 2004

www.moxa.com/product

Moxa Technologies Co., Ltd.

Tel: +886-2-8919-1230

Fax: +886-2-8919-1231

Web: www.moxa.com

MOXA Technical Support

Worldwide:

support@moxa.com.tw

The Americas

support@moxa.com

NPort 5110 User’s Manual

The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement.

Copyright Notice

Copyright 2004 Moxa Technologies Co., Ltd.

All rights reserved.

Reproduction without permission is prohibited.

Trademarks

MOXA is a registered trademark of Moxa Technologies Co., Ltd.

All other trademarks or registered marks in this manual belong to their respective manufacturers.

Disclaimer

Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa.

Moxa provides this document “as is,” without warranty of any kind, either expressed or implied, including, but not limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the products and/or the programs described in this manual, at any time.

Information provided in this manual is intended to be accurate and reliable. However, Moxa Technologies assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use.

This product might include unintentional technical or typographical errors. Changes are periodically made to the information herein to correct such errors, and these changes are incorporated into new editions of the publication.

Table of Contents

Chapter 1

Introduction ..............................................................................................

1-1

 

Overview..........................................................................................................

1-2

 

Package Checklist ...........................................................................................

1-2

 

Product Features .............................................................................................

1-2

 

Product Specifications .....................................................................................

1-3

Chapter 2

Getting Started .........................................................................................

2-1

 

Panel Layout....................................................................................................

2-2

 

Connecting the Hardware................................................................................

2-2

 

Connecting the Power .........................................................................................

2-2

 

Connecting to the Network..................................................................................

2-3

 

Connecting to a Serial Device .............................................................................

2-3

 

LED Indicators ....................................................................................................

2-3

Chapter 3

Initial IP Address Configuration..............................................................

3-1

 

Initializing NPort 5110’s IP Address ................................................................

3-2

 

Factory Default IP Address..............................................................................

3-2

 

NPort 5110 Administration Suite .....................................................................

3-2

 

ARP .................................................................................................................

3-2

 

Telnet Console.................................................................................................

3-3

 

Serial Console (19200, n, 8, 1)........................................................................

3-6

Chapter 4

Choosing the Proper Operation Mode ...................................................

4-1

 

Overview..........................................................................................................

4-2

 

TCP Server Mode............................................................................................

4-2

 

TCP Client Mode .............................................................................................

4-2

 

UDP Mode .......................................................................................................

4-3

 

Real COM Mode..............................................................................................

4-3

 

Pair Connection Mode .....................................................................................

4-3

 

Ethernet Modem Mode ....................................................................................

4-4

Chapter 5

Web Console Configuration ....................................................................

5-1

 

Opening Your Browser ....................................................................................

5-2

 

Basic Settings..................................................................................................

5-4

 

Network Settings .............................................................................................

5-5

 

Serial Settings..................................................................................................

5-8

 

Operating Settings.........................................................................................

5-10

 

Real COM Mode ...............................................................................................

5-10

 

TCP Server Mode..............................................................................................

5-12

 

TCP Client Mode ..............................................................................................

5-15

 

UDP Mode ........................................................................................................

5-18

 

Pair Connection Slave Mode.............................................................................

5-20

 

Pair Connection Master Mode...........................................................................

5-21

 

Ethernet Modem................................................................................................

5-22

 

Accessible IP Settings ...................................................................................

5-25

 

Auto Warning Settings...................................................................................

5-26

 

Auto Warning: E-mail and SNMP Trap............................................................

5-26

 

Event Type ........................................................................................................

5-27

 

Change Password .........................................................................................

5-29

 

Load Factory Defaults ...................................................................................

5-29

Chapter 6

Configuring Windows Administrator

...................................................... 6-1

 

Overview..........................................................................................................

6-2

 

Installing Windows Administrator.....................................................................

6-2

 

Configuration ...................................................................................................

6-6

 

Broadcast Search.................................................................................................

6-7

 

Unlock Password Protection .............................................................................

6-10

 

Configuring NPort 5110....................................................................................

6-12

 

Upgrade Firmware.............................................................................................

6-14

 

Export/Import....................................................................................................

6-15

 

Monitor...........................................................................................................

6-16

 

Port Monitor ...................................................................................................

6-22

 

COM Mapping................................................................................................

6-23

 

On-line COM Mapping .....................................................................................

6-23

 

Off-line COM Mapping ....................................................................................

6-29

 

IP Location.....................................................................................................

6-30

Chapter 7

IP Serial LIB ..............................................................................................

7-1

 

Overview..........................................................................................................

7-2

 

IP Serial LIB Function Groups.........................................................................

7-3

 

Example Program............................................................................................

7-3

Appendix A Pinouts and Cable Wiring.......................................................................

A-1

Port Pinout Diagrams ......................................................................................

A-2

Ethernet Port Pinouts...........................................................................................

A-2

Serial Port Pinouts...............................................................................................

A-2

Cable Wiring Diagrams....................................................................................

A-3

Ethernet Cables ...................................................................................................

A-3

Appendix B Well Known Port Numbers .....................................................................

B-1

Appendix C SNMP Agents with MIB II & RS-232 Like Groups .................................

C-1

Appendix D Auto IP Report Protocol..........................................................................

D-1

Appendix E Service Information..................................................................................

E-1

MOXA Internet Services ..................................................................................

E-2

Problem Report Form ......................................................................................

E-3

Product Return Procedure...............................................................................

E-4

1

Introduction

Welcome to NPort 5110, an advanced, 1-port RS-232 serial device server that makes it easy to network-enable your devices.

The following topics are covered in this chapter:

!Overview

!Package Checklist

!Product Features

!Product Specifications

NPort 5110 Series User’s Manual

Introduction

Overview

NPort 5110 serial device server is designed to make your industrial serial devices Internet ready instantly, and is well-suited for POS security market applications. The compact size of NPort 5110 device server makes them the ideal choice for connecting your RS-232 serial devices, such as card reader, payment terminal, to an IP-based Ethernet LAN, making it possible for your software to access serial devices located anywhere on a local LAN, or the Internet.

NPort 5110 serial device server provides TCP Server, TCP Client, UDP Server/Client, Pair Connection, and Ethernet Modem, ensuring the compatibility of network software that uses a standard network API (Winsock, BSD Sockets). And thanks to NPort’s Real COM/TTY drivers, software that works with COM/TTY ports can now work on a TCP/IP network in no time. This excellent feature preserves your software investment and lets you enjoy the benefits of networking your serial devices instantly.

NPort 5110 device servers support automatic IP configuration protocols (DHCP, BOOTP) and manual configuration via the handy web browser console. Both methods ensure quick and effective installation. And with NPort 5110’s Windows Utility, installation is very straightforward, since all system parameters can be stored and then copied to other device servers simultaneously.

Package Checklist

NPort 5110 products are shipped with the following items:

Standard Accessories

!1 NPort 5110 serial device server

!Quick Installation Guide

!NPort Documentation and Software CD-ROM

!Power Adaptor

Optional Accessories

!DK-35A: DIN-Rail Mounting Kit (35mm)

NOTE: Notify your sales representative if any of the above items is missing or damaged.

Product Features

NPort 5110 has the following features:

!Low cost, credit card size

!Makes your serial devices Internet ready

!Easy wall and DIN-Rail mounting

!Real COM/TTY driver for Windows and Linux

!Fixed TTY driver for SCO OpenServer, SCO Unixware 7, SCO Unixware 2.1

!Versatile socket operation modes, including TCP Server, TCP Client, UDP, and Ethernet Modem modes

!Pair Connection mode for connecting two serial devices over a network without a PC

!Easy-to-use Windows Utility for mass installation

!Auto-detecting 10/100 Mbps Ethernet

!Built-in 15KV ESD protection for all serial signals

!Supports SNMP MIB-II for network management

!Configuration via web/Telnet/serial console

!Configuration utility automatically finds NPort devices on the network

1-2

NPort 5110 Series User’s Manual Introduction

Product Specifications

LAN

 

Ethernet

10/100 Mbps, RJ45

Protection

Built-in 1.5 KV magnetic isolation

NPort 5110 Serial Interface

 

Interface

RS-232

No. of Ports

1

Port Type

Male DB9

Signals

TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

Serial Line Protection

15 KV ESD for all signals

Power Line Protection

 

4 KV Burst (EFT), EN61000-4-4

2 KV Surge, EN61000-4-5

Advanced Built-in Features

Watch Dog Timer

Serial Communication Parameters

Parity

None, Even, Odd, Space, Mark

Data Bits

5, 6, 7, 8

Stop Bit

1, 1.5, 2

Flow Control

RTS/CTS, XON/XOFF, DTR/DSR

Transmission Speed

110 bps to 230.4 Kbps

Software Features

 

Protocols

ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP,

 

HTTP, SMTP

Utilities

NPort Administrator for Windows 95/98/ME/NT/2000/XP/2003

Real COM/TTY Drivers

Windows 95/98/ME/NT/2000/XP/2003 Real COM driver,

 

Linux real TTY driver, Unix fixed TTY driver

Configuration

Web Browser, Serial/Telnet Console, or Windows Utility

Power Requirements

 

Power Input

9 to 30 VDC

Power Consumption

 

Mechanical

 

Casing

Aluminum case (1 mm)

Dimensions (W × H × D)

50 × 80 × 22 mm (1.97 × 3.15 × 0.87 in)

Environmental

 

Operating Temperature

0 to 55°C (32 to 131°F), 5 to 95%RH

Storage Temperature

-20 to 85°C (-4 to 185°F), 5 to 95%RH

Regulatory Approvals

 

EMC

FCC Class A, CE Class A

Safety

UL, CUL, TÜV

WARRANTY

5 years

1-3

2

Getting Started

This chapter includes information about installing NPort 5110. The following topics are covered:

!Panel Layout

!Connecting the Hardware

"Connecting the Power

"Connecting to the Network

"Connecting to a Serial Device

"LED Indicators

NPort 5110 Series User’s Manual

Getting Started

Panel Layout

NPort 5110

Rear Panel View

RJ45 10/100M Ethernet port

Reset button

Power input

Top Panel View

RESET

10/100M

9-30VDC

Ethernet

 

5110

Serial Device Server

Ready

 

Link

 

Tx/Rx

 

Port 1 RS-232

 

DIN-Rail screw hole

Wallmount screw hole

Front Panel View

Male DB9 serial port

Stick-on pad

Connecting the Hardware

This section describes how to connect NPort 5110 to serial devices for first time testing purposes. We cover Connecting to the Network, Connecting to a Serial Device, and LED Indicators.

Connecting the Power

Connect the 9-30 VDC power cord with NPort 5110’s power input. The “Ready” LED will show a solid red color until the system is ready, at which time the “Ready” LED will change to a green color.

2-2

NPort 5110 Series User’s Manual

Getting Started

Connecting to the Network

Connect one end of the Ethernet cable to NPort 5110’s 10/100M Ethernet port and the other end of the cable to the Ethernet network. NPort 5110 will indicate a valid connection to the Ethernet in the following ways:

!The Ethernet LED maintains a solid green color when connected to a 100 Mbps Ethernet network.

!The Ethernet LED maintains a solid orange color when connected to a 10 Mbps Ethernet network.

!The Ethernet LED will flash when Ethernet packets are being transmitted or received.

Connecting to a Serial Device

Connect the serial data cable between NPort 5110 and the serial device. NPort 5110’s serial port uses the RS-232 interface to transmit data. The port uses a standard male DB9 pin assignment. Refer to Appendix A to see the signal definitions for the port.

LED Indicators

NPort 5110 has 3 LED indicators, as described in the following table.

LED Name

LED Color

 

LED Function

 

 

Steady on: Power is on and NPort 5110 is booting up.

 

Red

Blinking:

Indicates an IP conflict, or DHCP or BOOTP server

 

 

 

did not respond properly.

Ready

Green

Steady on: Power is on and NPort 5110 is functioning normally.

 

Blinking:

The device server has been located by

 

 

 

Administrator’s Location function.

 

Off

Power is off, or power error condition exists.

 

Orange

10 Mbps Ethernet connection.

Link

Green

100 Mbps Ethernet connection.

 

Off

Ethernet cable is disconnected, or has a short.

 

 

 

 

Orange

Serial port is receiving data.

Tx/Rx

 

 

Green

Serial port is transmitting data.

 

 

 

 

Off

No data is being transmitted or received through the serial port.

 

 

 

 

2-3

3

Initial IP Address Configuration

When setting up your NPort 5110 for the first time, you should first configure the IP address. This chapter introduces the method to configure the device server’s IP address. For more details about network settings, see the Network Settings section from Chapter 5, Web Console Configuration.

This chapter includes the following sections:

!Initializing NPort 5110’s IP Address

!Factory Default IP Address

!NPort 5110 Administration Suite # recommended configuration method

!ARP

!Telnet Console

!Serial Console (19200, n, 8, 1)

NPort 5110 Series User’s Manual

Initial IP Address Configuration

Initializing NPort 5110’s IP Address

1.Determine whether your NPort 5110 needs to use a Static IP or Dynamic IP (either DHCP or BOOTP application).

2.If NPort 5110 is used in a Static IP environment, you can use NPort 5110 Administration Suite, ARP, Web Console, Telnet Console, or Serial Console to configure the new IP address.

3.If NPort 5110 is used in a Dynamic IP environment, you can use NPort 5110 Administration Suite, Web Console, Telnet Console, or Serial Console to configure NPort 5110 to get an IP address dynamically with DHCP, DHCP/BOOTP, or BOOTP.

ATTENTION

Consult your network administrator on how to reserve a fixed IP address for your NPort 5110 in the MAC-IP mapping table when using a DHCP Server or BOOTP Server. In most applications, you should assign a fixed IP address to your NPort 5110.

Factory Default IP Address

NPort 5110 products are configured with the following default private IP address:

Default IP address:

192.168.127.254

(IP addresses of the form 192.168.xxx.xxx are referred to as private IP addresses, since it is not possible to directly access a device configured with a private IP address from a public network. For example, you would not be able to ping such a device from an outside Internet connection. NPort 5110 applications that require sending data over a public network, such as the Internet, require setting up the server with a valid public IP address, which can be leased from a local ISP.)

NPort 5110 Administration Suite

NPort 5110 Administration Suite consists of some useful utility programs that are used to configure and manage your NPort 5110s.

See Chapter 5 for details on how to install NPort 5110 Administration Suite, and how to use this suite of useful utilities to set up IP addresses and configure your NPort 5110 serial device servers.

ARP

You can make use of the ARP (Address Resolution Protocol) command to set up an IP address for your NPort 5110. The ARP command tells your computer to associate the NPort 5110’s MAC address with the intended IP address. You must then use Telnet to access the NPort 5110, at which point the device server’s IP address will be reconfigured.

ATTENTION

In order to use the ARP setup method, both your computer and NPort 5110 must be connected to the same LAN. Or, you may use a cross-over Ethernet cable to connect the NPort 5110 directly to your computer’s Ethernet card. Your NPort 5110 must be configured with the factory default IP address—192.168.127.254—before executing the ARP command, as described below.

3-2

NPort 5110 Series User’s Manual

Initial IP Address Configuration

Take the following steps to use ARP to configure the IP address:

1.Obtain a valid IP address for your NPort 5110 from your network administrator.

2.Obtain NPort 5110’s MAC address from the label on its bottom panel.

3.Execute the ‘arp -s’ command from your computer’s MS-DOS prompt by typing:

arp –s 192.168.200.100 00-90-E8-xx-xx-xx

This is where 192.168.200.100 is the new IP address and 00-90-E8-xx-xx-xx is the MAC address for your NPort 5110. You will need to change both numbers, as described above in items 1 and 2.

4. Next, execute a special Telnet command by typing: telnet 192.168.200.100 6000

After issuing this command, a Connect failed message will appear, as shown here. After the NPort 5110 reboots, its IP address should be updated to the new address, and you can reconnect using either Telnet, Web, or Administrator to check that the update was successful.

Telnet Console

Depending on how your computer and network are configured, you may find it convenient to use network access to set up your NPort 5110’s IP address. This can be done using Telnet.

1.From the Windows desktop, click on Start and then select Run.

2.Type telnet 192.168.127.254 (use the correct IP address if different from the default) in the Open text input box, and then click OK.

3.When the Telnet window opens, if you are prompted to input the Console password, input the password and then press Enter. Note that this page will only appear if the NPort 5110 is password protected.

3-3

NPort 5110 Series User’s Manual

Initial IP Address Configuration

4.Type 2 to select Network settings, and then press Enter.

5.Type 1 to select IP address and then press Enter.

3-4

NPort 5110 Series User’s Manual

Initial IP Address Configuration

6.Use the Backspace key to erase the current IP address, type in the new IP address, and then press Enter.

7.Press any key to continue.

3-5

NPort 5110 Series User’s Manual

Initial IP Address Configuration

8.Type m and then press Enter to return to the main menu.

9.Type s and then press Enter to Save/Restart the system.

10. Type y and then press Enter to save the new IP address and restart NPort 5110.

Serial Console (19200, n, 8, 1)

You may use the RS-232 console port to set up the IP address for NPort 5110. We suggest using PComm Terminal Emulator, which is available free of charge as part of the PComm Lite program suite (found on the Software CD that comes with the product), to carry out the installation procedure, although other similar utilities may also be used.

Before you start to configure the NPort 5110 via serial console, turn off the power and connect the serial cable from NPort 5110 to your computer’s serial port.

3-6

NPort 5110 Series User’s Manual

Initial IP Address Configuration

1.Connect NPort 5110’s serial port 1 directly to your computer’s male RS-232 serial port.

2.From the Windows desktop click on Start $ Programs $ PComm Lite $ Terminal Emulator.

3.When the PComm Terminal Emulator window opens, first click on the Port Manager menu item and select Open, or simply click on the Open icon.

4.The Property window opens automatically. From the Communication Parameter page, select the appropriate COM port for the connection, COM1 in this example, and 19200 for

Baud Rate, 8 for Data Bits, None for Parity, and 1 for Stop Bits.

5.From the Property window’s Terminal page, select ANSI or VT100 for Terminal Type and then click OK. If you select Dumb Terminal as the terminal type, some of the console functions—especially the “Monitor” function—may not work properly.

6.Press the “ ` ” key continuously and then power on the NPort 5110.

7.NPort 5110 will receive the “ ` ” string continuously and then auto switch from data mode to console mode.

3-7

NPort 5110 Series User’s Manual

Initial IP Address Configuration

8.Input the password when prompted. Note that this page will only appear when the NPort 5110 has been set up for password protection.

9.Start configuring the IP address under Network Settings. Refer to step 4 in the Telnet Console section for instructions on how to configure the rest of the IP settings.

3-8

4

Choosing the Proper Operation Mode

In this section, we describe the various NPort 5110 operation modes. The options include an operation mode that uses a driver installed on the host computer, and operation modes that rely on TCP/IP socket programming concepts. After choosing the proper operation mode in this chapter, refer to Chapter 5 for detailed configuration parameter definitions.

!Overview

!TCP Server Mode

!TCP Client Mode

!UDP Mode

!Real COM Mode

!Pair Connection Mode

!Ethernet Modem Mode

NPort 5110 Series User’s Manual

Choosing the Proper Operation Mode

Overview

NPort 5110 Serial Device Servers are used to network-enable traditional RS-232 devices. A Serial Device Server is a tiny computer equipped with a CPU, real-time OS, and TCP/IP protocols that can bi-directionally transfer data between the serial and Ethernet formats. Your computer can access, manage, and configure remote facilities and equipment over the Internet from anywhere in the world.

Traditional SCADA and data collection systems rely on serial ports (RS-232) to collect data from various kinds of instruments. Since NPort 5110 Serial Device Servers network-enable instruments equipped with an RS-232 communication port, your SCADA and data collection system will be able to access all instruments connected to a standard TCP/IP network, regardless of whether the devices are used locally or at a remote site.

NPort 5110 is an external IP-based network device that allows you to expand the number of serial ports for a host computer on demand. As long as your host computer supports the TCP/IP protocol, you won’t be limited by the host computer’s bus limitation (such as ISA or PCI), or lack of drivers for various operating systems.

In addition to providing socket access, NPort 5110 also comes with a Real COM/TTY driver that transmits all serial signals intact. This means that your existing COM/TTY-based software can be preserved, without needing to invest in additional software.

Three different Socket Modes are available: TCP Server, TCP Client, and UDP Server/Client. The main difference between the TCP and UDP protocols is that TCP guarantees delivery of data by requiring the recipient to send an acknowledgement to the sender. UDP does not require this type of verification, making it possible to offer speedier delivery. UDP also allows data to be unicast or multicast to only one IP or to different groups of IP addresses.

TCP Server Mode

In TCP Server mode, NPort 5110 is configured with a unique IP:Port address on a TCP/IP network. NPort 5110 waits passively to be contacted by the host computer, allowing the host computer to establish a connection with and get data from the serial device. This operation mode also supports up to 4 simultaneous connections, so that multiple hosts can collect data from the same serial device—at the same time.

As illustrated in the figure, data transmission proceeds as follows:

1.The host requests a connection from the NPort 5110 configured for TCP Server Mode.

2.Once the connection is established, data can be transmitted in both directions—from the host to the NPort 5110, and from the NPort 5110 to the host.

TCP Client Mode

In TCP Client mode, NPort 5110 can actively establish a TCP connection to a pre-defined host computer when serial data arrives.

After the data has been transferred, NPort 5110 can automatically disconnect from the host computer by using the TCP alive check time or Inactivity time settings. Refer to Chapter 5 for more details.

Data transmission proceeds as follows:

1.The NPort 5110 configured for TCP Client Mode requests a connection from the host.

2.Once the connection is established, data can be transmitted in both directions—from the host to the NPort 5110, and from the NPort 5110 to the host.

4-2

NPort 5110 Series User’s Manual

Choosing the Proper Operation Mode

UDP Mode

Compared to TCP communication, UDP is faster and more efficient. In UDP mode, you can unicast or multicast data from the serial device to one or multiple host computers, and the serial device can also receive data from one or multiple host computers, making this mode ideal for message display applications.

Real COM Mode

NPort 5110 comes equipped with COM drivers that work with Windows 95/98/ME/NT/2000/XP systems, and also TTY drivers for Linux systems. The driver establishes a transparent connection between host and serial device by mapping the IP:Port of the NPort 5110 port to a local COM port on the host computer. This operation mode also supports up to 4 simultaneous connections, so that multiple hosts can collect data from the same serial device at the same time.

ATTENTION

The driver used for Real COM Mode is installed automatically on your computer when you install NPort 5110 Administration Suite.

One of the major conveniences of using Real COM Mode is that Real COM Mode allows users to continue using RS-232 serial communications software that was written for pure serial communications applications. The driver intercepts data sent to the host’s COM port, packs it into a TCP/IP packet, and then redirects it through the host’s Ethernet card. At the other end of the connection, the NPort 5110 accepts the Ethernet frame, unpacks the TCP/IP packet, and then transparently sends it to the appropriate serial device attached to one of the NPort 5110’s serial ports.

ATTENTION

Real COM Mode allows several hosts to have access control of the same NPort 5110. The driver that comes with your NPort 5110 controls host access to attached serial devices by checking the host’s IP address. Refer to Accessible IP Settings in Chapter 5 for more details.

Pair Connection Mode

Pair Connection Mode employs two NPort 5110 device servers in tandem, and can be used to remove the 15-meter distance limitation imposed by the RS-232 interface. One NPort 5110 is connected from its RS-232 port to the COM port of a PC or other type of computer, such as hand-held PDAs that have a serial port, and the serial device is connected to the RS-232 port of the other NPort 5110. The two NPort 5110 are then connected to each other with a cross-over Ethernet cable, both are connected to the same LAN, or in a more advanced setup, they communicate with each other over a WAN (i.e., through one or more routers). Pair Connection Mode transparently transfers both data and modem control signals (although it cannot transmit the DCD signal) between the two NPorts.

4-3

NPort 5110 Series User’s Manual

Choosing the Proper Operation Mode

Ethernet Modem Mode

The Ethernet Modem operation mode is designed for use with legacy operating systems, such as MS-DOS, that do not support TCP/IP Ethernet. By connecting one NPort 5110’s serial port to the MS-DOS computer’s serial port, it is possible to use legacy software originally designed to transmit data via modem, but now transmit the data over the Ethernet.

4-4

5

Web Console Configuration

The Web Console is the most user-friendly method available to configure NPort 5110. This chapter introduces the Web Console function groups and function definitions.

!Opening Your Browser

!Basic Settings

!Network Settings

!Serial Settings

!Operating Settings

"Real COM Mode

"TCP Server Mode

"TCP Client Mode

"UDP Mode

"Pair Connection Slave Mode

"Pair Connection Master Mode

"Ethernet Modem

!Accessible IP Settings

!Auto Warning Settings

"Auto Warning: E-mail and SNMP Trap

"Event Type

!Change Password

!Load Factory Defaults

Moxa Technologies NPort 5110 User Manual

NPort 5110 Series User’s Manual

Web Console Configuration

Opening Your Browser

1.Open your browser with the cookie function enabled. (To enable your browser for cookies, right click on your desktop Internet Explorer icon, select Properties, click on the Security tab, and then select the three Enable options as shown in the figure below.)

2.Type 192.168.127.254 in the Address input box (use the correct IP address if different from the default), and then press Enter.

3.Input the password if prompted. The password will be transmitted with MD5 encryption over the Ethernet. Note that you will not be prompted to enter the password if the NPort 5110 is not currently password protected.

ATTENTION

If you use other web browsers, remember to Enable the functions to “allow cookies that are stored on your computer” or “allow per-session cookies.”

NPort 5110 uses cookies only for “password” transmission.

5-2

NPort 5110 Series User’s Manual

Web Console Configuration

ATTENTION

Refer to Chapter 3, “Initial IP Address Configuration,” to see how to configure the IP address. Examples shown in this chapter use the Factory Default IP address (192.168.127.254).

4.The NPort 5110 homepage will open. On this page, you can see a brief description of the Web Console’s nine function groups.

ATTENTION

If you can’t remember the password, the ONLY way to start configuring NPort 5110 is to load factory defaults by using the Reset button located near the NPort 5110’s RJ45 Ethernet port.Remember to use Windows Administrator to export the configuration file when you have finished the configuration. After using the Reset button to load factory defaults, your configuration can be easily reloaded into NPort 5110 by using the Windows Administrator Import function.If your NPort 5110 application requires using password protection, you must enable the cookie function in your browser. If the cookie function is disabled, you will not be allowed to enter the Web Console Screen.

5-3

NPort 5110 Series User’s Manual

Web Console Configuration

Basic Settings

Server name

Setting

Factory Default

Necessity

1 to 39 characters

[model name]_[Serial No.]

Optional

This option is useful for specifying the location or application of different NPort 5110s.

Web/Telnet Console

The “Disable” option for “Web Console” and “Telnet Console” is included for security reasons. In some cases, you may want to Disable one or both of these console utilities as an extra precaution to prevent unauthorized users from accessing your NPort 5110. The factory default for both Web console and Telnet console is Enable.

Web Console

Setting

Factory Default

Necessity

Enable or Disable

Enable

Required

ATTENTION

If you disable both the “Web console” and “Telnet console,” you can still use Windows Administrator to configure NPort 5110 either locally or remotely over the network. Refer to Chapter 6 for more details.

5-4

NPort 5110 Series User’s Manual

Web Console Configuration

Network Settings

You must assign a valid IP address to NPort 5110 before it will work in your network environment. Your network system administrator should provide you with an IP address and related settings for your network. The IP address must be unique within the network (otherwise, NPort 5110 will not have a valid connection to the network). First time users can refer to Chapter 3, “Initial IP Address Configuration,” for more information.

You can choose from four possible “IP configuration” modesStatic, DHCP, DHCP/BOOTP, and BOOTPlocated under the web console screen’s IP configuration drop-down box.

IP configuration

Method

Function Definition

 

 

Static

User defined IP address, Netmask, Gateway.

DHCP

DHCP Server assigned IP address, Netmask, Gateway, DNS, and Time

 

Server

DHCP/BOOTP

DHCP Server assigned IP address, Netmask, Gateway, DNS, and Time

 

Server, or BOOTP Server assigned IP address (if the DHCP Server does not

 

respond)

BOOTP

BOOTP Server assigns IP address

5-5

NPort 5110 Series User’s Manual

Web Console Configuration

 

IP address

 

 

 

 

Setting

Factory Default

Necessity

 

 

E.g., 192.168.1.1

192.168.127.254

Required

 

 

(IP addresses of the form x.x.x.0 and

 

 

 

 

x.x.x.255 are invalid.)

 

 

 

An IP address is a number assigned to a network device (such as a computer) as a permanent address on the network. Computers use the IP address to identify and talk to each other over the network. Choose a proper IP address which is unique and valid in your network environment.

Netmask

Setting

Factory Default

Necessity

E.g., 255.255.255.0

255.255.255.0

Required

A subnet mask represents all of the network hosts at one geographic location, in one building, or on the same local area network. When a packet is sent out over the network, the NPort 5110 will use the subnet mask to check whether the desired TCP/IP host specified in the packet is on the local network segment. If the address is on the same network segment as the NPort 5110, a connection is established directly from the NPort 5110. Otherwise, the connection is established through the given default gateway.

Gateway

Setting

Factory Default

Necessity

E.g., 192.168.1.1

None

Optional

A gateway is a network gateway that acts as an entrance to another network. Usually, the computers that control traffic within the network or at the local Internet service provider are gateway nodes. NPort 5110 needs to know the IP address of the default gateway computer in order to communicate with the hosts outside the local network environment. For correct gateway IP address information, consult the network administrator.

IP configuration

Setting

Factory Default

Necessity

Static

Static

Required

DHCP

 

 

DHCP/BOOTP

 

 

BOOTP

 

 

ATTENTION

In Dynamic IP environments, the firmware will retry 3 times every 30 seconds until network settings are assigned by the DHCP or BOOTP server. The Timeout for each try increases from 1 second, to 3 seconds, to 5 seconds.If the DHCP/BOOTP Server is unavailable, the firmware will use the default IP address (192.168.127.254), Netmask, and Gateway for IP settings.

DNS server 1 / DNS server 2

Setting

Factory Default

Necessity

E.g., 192.168.1.1

None

Optional

(IP addresses of the form x.x.x.0 and

 

 

x.x.x.255 are invalid.)

 

 

When the user wants to visit a particular website, the computer asks a Domain Name System (DNS) server for the website’s correct IP address, and then the computer uses the response to

5-6

NPort 5110 Series User’s Manual

Web Console Configuration

connect to the web server. DNS is the way that Internet domain names are identified and translated into IP addresses. A domain name is an alphanumeric name, such as moxa.com, that it is usually easier to remember. A DNS server is a host that translates this kind of text-based domain name into the numeric IP address used to establish a TCP/IP connection.

In order to use NPort 5110’s DNS feature, you need to configure the DNS server. Doing so allows NPort 5110 to use a host’s domain name to access the host. NPort 5110 provides DNS server 1 and DNS server 2 configuration items to configure the IP address of the DNS server. DNS Server 2 is included for use when DNS sever 1 is unavailable.

NPort 5110 plays the role of DNS client, in the sense that the NPort 5110 will actively query the DNS server for the IP address associated with a particular domain name. NPort 5110 functions that support domain name are Time server, Destination IP Address in TCP Client mode, Mail Server, SNMP trap server, and Auto report to IP.

SNMP Settings

Community name

Setting

Factory Default

Necessity

1 to 39 characters

public

Optional

(E.g., Support, 886-89191230 #300)

 

 

A community name is a plain-text password mechanism that is used to weakly authenticate queries to agents of managed network devices.

Contact

Setting

Factory Default

Necessity

1 to 39 characters

None

Optional

(E.g., Support, 886-89191230 #300)

 

 

The SNMP contact information usually includes an emergency contact name and telephone or pager number.

Location

Setting

Factory Default

Necessity

1 to 39 characters

None

Optional

(E.g., Floor 1, office 2)

 

 

Specify the location string for SNMP agents such as NPort 5110. This string is usually set to the street address where the NPort 5110 is physically located.

IP Address Report

When NPort 5110 products are used in a dynamic IP environment, users must spend more time with IP management tasks. For example, if NPort 5110 works as a server (TCP or UDP), then the host, which acts as a client, must know the IP address of the server. If the DHCP server assigns a new IP address to NPort 5110, the host must have some way of determining NPort 5110’s new IP address.

NPort 5110 products help out by periodically reporting their IP address to the IP location server, in case the dynamic IP has changed. The parameters shown below are used to configure the Auto IP report function. There are two ways to develop an “Auto IP report Server” to receive NPort 5110’s Auto IP report.

1.Use Device Server Administrator’s IP Address Report function.

2.“Auto IP report protocol”, which can automatically receive the Auto IP report on a regular basis, is also available to help you develop your own software. Refer to Appendix E for the “Auto IP report protocol”.

5-7

NPort 5110 Series User’s Manual

Web Console Configuration

 

Auto report to IP

 

 

 

 

Setting

Factory Default

Necessity

 

 

E.g., 192.168.1.1 or URL

None

Optional

 

 

(IP addresses of the form x.x.x.0 and

 

 

 

 

x.x.x.255 are invalid.)

 

 

 

 

Reports generated by the Auto report function will be automatically sent to this IP address.

 

 

Auto report to TCP port

 

 

 

 

Setting

Factory Default

Necessity

 

 

E.g., 4001

4002

Optional

 

 

Auto report period

 

 

 

 

Setting

Factory Default

Necessity

 

 

Time interval (in seconds)

10

Optional

 

Serial Settings

Click on Serial Settings, located under Main Menu, to display serial port settings for port 1.

To modify serial settings for a particular port, click on either Port 1 under Serial Settings, located under Main Menu on the left side of the browser window.

5-8

Loading...