Moxa Technologies MGate W5108, MGate W5208 Quick Installation Manual

P/N: 1802051080011
*1802051080011*
MGate W5108/W5208 Series
Edition 2.0, May 2017
Technical Support Contact Information
www.moxa.com/support
Moxa Americas
:
Toll
-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa China (Shanghai office)
:
Toll
-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Europe: Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa Asia-Pacific: Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
Moxa India: Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
2017 Moxa Inc. All rights reserved.
- 2 -
Overview
The MGate W5108/W5208 series of gateways come with 1 or 2 serial ports, making them an ideal choice for connecting Modbus/DNP3 serial devices to a wireless LAN. With IEEE 802.11a/b/g/n support, you can use fewer cables in difficult wiring environments, and for secure data transmission, the MGate W5108/W5208 series gateways support WEP/WPA/WPA2. The gateways’ rugged design makes them suitable for industrial applications, including oil & gas, power plant, process automation, and factory automation.
Package Checklist
Before installing the MGate W5108/W5208 gateway, verify that the package contains the following items:
1 MGate W5108 or W5208 gateway
1 antenna
Documentation and software CD
Quick installation guide (printed)
Warranty card
Optional Accessories
Mini DB9F-to-TB Adapter: DB9 female to terminal block adapter for RS-422/485 applications
WK-51-01: Wall mounting kit
DR-4524: 45W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC input
DR-75-24: 75W/3.2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC input
DR-120-24: 120W/5A DIN-rail 24 VDC power supply with 88 to 132 VAC or 176 to 264 VAC input, selected by DIP switch
Notify your sales representative if any of the above items are missing or damaged.
Hardware Introduction
As shown in the following figures, the MGate W5108 has 1 DB9 port for transmitting serial data, and the MGate W5208 has 2 DB9 ports for transmitting serial data. The MGate W5108/W5208 gateways come with 2 kV serial port isolation protection built in.
- 3 -
MGate W5108
MGate W5208
- 4 -
Reset Button—Depress the Reset button continuously for 5 sec to load factory defaults.
The reset button is used to load factory defaults. Depress the reset button for five seconds using a pointed object, such as a straightened paper clip. Release the reset button when the Ready LED stops blinking.
LED Indicators
Name
Color
Function
PWR 1,
PWR 2
Green
Power is being supplied to the power input.
Off
Power cable is not connected.
Ready
Green
Steady on: Power is on and unit is functioning normally.
Blinking: Unit is responding to DSU’s locate function.
Red
Steady on: Power is on and the unit is booting up.
Blinking: IP conflict, DHCP, or BOOTP server did not respond properly, or a relay output occurred.
Off
Power is off.
P1, P2
Green
Serial port is transmitting data.
Amber
Serial port is receiving data.
Off
Data is not being transmitted.
Ethernet
Green
Indicates a 100 Mbps Ethernet connection.
Amber
Indicates a 10 Mbps Ethernet connection.
Off
Ethernet cable is disconnected.
WLAN
Green
Steady On: Unit is properly connected with the AP.
Blinking: Unit is trying to connect to the AP.
Red
Indicates an IP conflict, or DHCP or BOOTP server is not responding properly.
RF Green
3 LEDs = signal strength is between 67% and 100%. 2 LEDs = signal strength is between 34% and 66%.
1 LED = signal strength is between 0% and 33%.
Hardware Installation Procedure
STEP 1:
After unpacking the unit, connect the power supply to the unit.
STEP 2:
Use an Ethernet cable to connect the unit to the
network.
STEP 3:
Connect your device to the desired port on the unit.
STEP 4:
Place or mount the unit. The unit may be placed on a horizontal surface such as a desktop, or mounted on the wall.
Wall or Cabinet Mounting
T
wo metal plates are provided for mounting the unit
on a wall or inside a cabinet. Attach the plates to the unit
’s rear panel with screws. With the plates
attached, use screws to mount the unit on a wall.
For each screw, the head should be 6.0 mm or less in diameter, and the shaft should be 3.5 mm or less in diameter.
Termination Resistor and Adjustable Pull High/Low Resistors
In some critical environments, you may need to add termination resistors to prevent the reflection of serial signals. When using termination
- 5 -
resistors, it is important to set the pull high/low resistors correctly so that the electrical signal is not corrupted. The MGate W5108/W5208 uses DIP switches to set the pull high/low resistor values for each serial port.
To add a 120 Ω termination resistor, set switch 3 on the port’s assigned DIP switch to ON; set switch 3 to OFF (the default setting) to disable the termination resistor.
To set the pull high/low resistors to 150 KΩ, set switches 1 and 2 on the port’s assigned DIP switch to OFF. This is the default setting.
To set the pull high/low resistors to 1 KΩ, set switches 1 and 2 on the port’s assigned DIP switch to ON.
Pull High/low Resistors for the RS-485 Port
Default
SW
1 2 3
Pull High
Pull Low
Terminator
ON
1 KΩ
1 KΩ
120 Ω
OFF
150 KΩ
150 KΩ
Software Installation Information
To configure your MGate W5108/W5208, connect the gateway’s Ethernet port directly to your computer’s Ethernet port and then log in from a web browser. The default IP address is 192.168.127.254. The MGate supports two types of accounts: admin and user. The admin account can modify all settings, whereas the user accounts can only view settings. The default password for the admin account is “moxa”.
If you forget the modified IP address of the gateway or cannot log in to the gateway via a web browser for any reason, you can access the gateway via a direct Ethernet cable connection using the Device search utility to search for the gateway.
To install Device Search Utility (DSU), insert the MGate Documentation and Software CD into your PC’s CD-ROM drive, and then run the following setup program to begin the installation process from the “Software” directory:
dsu_setup_[Version]_Build_[DateTime].exe
The filename of the latest version may have the following format:
dsu_setup_Verx.x.x_Build_xxxxxxxx.exe.
For detailed information about DSU, refer to the MGate W5108/W5208 User’s Manual, which can be found in the “Document” directory.
- 6 -
Pin Assignments
RJ45 (LAN)
Pin
LAN
1
Tx+ 2 Tx-
3
Rx+ 4 – 5 – 6 Rx- 7 – 8 –
DB9 Male (RS-232/422/485)
Pin RS-232
RS-422/
RS-485-4W
RS-485-2W
1
DCD
TxD-(A)
2
RxD
TxD+(B)
3
TxD
RxD+(B)
Data+(B)
4
DTR
RxD-(A)
Data-(A)
5
GND
GND
GND
6
DSR – –
7
RTS – –
8
CTS – – 9 – – –
Power Input and Relay Output Pinouts
V2+ V2-
V1+ V1-
DC Power
Input 2
DC Power
Input 2
N.O. Common N.C.
DC Power
Input 1
DC Power
Input 1
DI/DO Pinouts
COM
DI0
DI1
GND
DO0
DO1
Common
Digital
Input 0
Digital
Input 1
Ground
Digital
Output 0
Digital
Output 1
- 7 -
Specifications
Power Input
9 to 60 VDC
Power Consumption
495 mA @ 9 V, 202 mA @ 24 V, 114 mA @ 48 V, 99 mA @ 60 V
Operating Temperature
Standard models:
0 to 60°C (32 to 140°F) Wide temp. models:
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature
-40 to 85°C (-40 to 185°F)
Operating Humidity
5 to 95% RH
Dimensions (W x D x H)
MGate W5108:
45.8 x 105 x 134 mm (1.8 x 4.13 x 5.28 in) MGate W5208:
59.6 x 101.7 x 134 mm (2.35 x 4.0 x 5.28 in)
Magnetic Isolation
1.5 kV for Ethernet, 2 kV for serial port
Regulatory Approvals FCC Class A, CE Class A, EN 60950-1,
UL61010-2-201
Hazard Location
Class 1 Division 2, ATEX, IECEx
Fault Relay Circuit
3-pin circuit with current carrying capacity of 2 A @ 30 VDC
ATEX Information
1. Certificate number: DEMKO 16 ATEX 1641X
2. Certification string: Ex nA nC IIC T4 Gc
3. Standards covered: EN 60079-0:2012+A11:2013, EN 60079-15:2010
4. The equipment shall be installed in an enclosure that provides a degree of protection not less than IP54 in accordance with EN 60079-15 and accessible only by the use of a tool.
5. These products are for use in an area of not more than pollution degree 2 in accordance with IEC 60664-1.
Loading...