Moxa Technologies IKS-6726-8PoE Hardware Installation Manual

— 1 — — 2 — — 3 —
IKS-6726-8PoE Series
Hardware Installation Guide
Package Checklist
The Moxa IKS-6726-8PoE series industrial rackmount switches are shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance.
y 1 Moxa IKS-6726-8PoE Switch y Hardware Installation Guide y CD-ROM with User’s Manual and SNMP MIB file y Moxa Product Warranty Statement y RJ45 to DB9 console port cable y Protective caps for unused ports y 2 rack-mount ears
Panel Layouts
1
2
3
4
569
10
11
7
8 12
1. System status LEDs
2. Mode LEDs for the nterface module
3. Port LEDs for the interface module
4. Push-button switch for selecting the mode of the interface module
5. Model name
6. 10/100BaseT(X) port
7. 10/100BaseT(X) PoE port
8. Fast Ethernet / PoE interface module
9. Gigabit Ethernet interface module
10. Serial console port
11. 10-pin terminal block for power inputs and relay output
12. Rack mounting brackets
Dimensions (unit = mm)
440
44
323.5
347.8
462.6
Top View
Rear View
Side ViewSide View
Front View
Fast Ethernet / PoE Interface Modules (for slot 1)
96.8
40.7
40.7
96.8
96.8
40.7
40.7
96.8
PM-7200-8TX
PM-7200-4MSC2TX/PM-7200-4SSC2TX
PM-7200-4MST2TX PM-7200-6MST
PM-7200-6MSC/PM-7200-6SSC PM-7200-2MSC4TX/PM-7200-2SSC4TX
PM-7200-2MST4TX
PM-7200-1LSC6TX
96.8
40.7
96.8
40.7
40.7
96.8
96.8
40.7
96.8
40.7
PM-7200-8PoE
Gigabit Ethernet Interface Modules (for slot 2)
40.7
86.6
PM-7200-2GTXSFP
Rack Mounting
Use four screws to attach the switch to a standard rack.
Wiring Requirements
WARNING
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your Moxa industrial rackmount switch.
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.
Grounding the Moxa Industrial Rackmount Switch
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.
Wiring the Power Inputs
The IKS series switches support dual redundant power supplies: Power Supply 1 (PWR1) and Power Supply 2 (PWR2). The connections for
PWR1, PWR2, and the RELAY are located on the terminal block. The front view of the terminal block connectors is shown below.
Wiring the Relay Contact
Each IKS switch has one relay output. Refer to the next section for detailed instructions on how to connect the wires to the terminal block connector, and how to attach the terminal block connector to the terminal block receptor.
P/N: 1802067260020
— 4 — — 5 — — 6 —
FAULT: The relay contact of the 10-pin terminal block connector are used to detect user-configured events. The two wires attached to the RELAY contacts form an open circuit when a user-configured event is triggered. If a user-configured event does not occur, the RELAY circuit will be closed.
Wiring the Redundant Power Inputs
Each IKS switch has two sets of power inputs: power input 1 and power input 2.
STEP 1: Insert the dual set positive/negative DC wires into PWR1 and PWR2 terminals (+ pins 1, 9; - pins 2, 10), or insert the L/N AC wires into PWR1 and PWR2 terminals (L pin 1, 9; N pin 2,10)
STEP 2: To keep the DC or AC wires from pulling loose, use a screwdriver to tighten the wire-clamp screws on the front of the terminal block connector.
LED Indicators
The front panel of the IKS switch contains several LED indicators. The function of each LED is described in the table below.
LED Color State Description
System LEDs
On
System has passed self-diagnosis test on boot-up and is ready to run.
GREEN
Blinking
System is undergoing the self-diagnosis test.
STAT
RED On System failed self-diagnosis on boot-up.
On
Power is being supplied to the main module’s power input PWR1.
PWR1 AMBER
Off
Power is not being supplied to the main module’s power input PWR1.
On
Power is being supplied to the main module’s power input PWR2.
PWR2 AMBER
Off
Power is not being supplied to the main module’s power input PWR2.
On
The corresponding PORT alarm is enabled and a user-configured event has been triggered.
FAULT RED
Off
The corresponding PORT alarm is enabled and a user-configured event has not been triggered, or the corresponding PORT alarm is disabled.
On
This IKS switch is the Master of this Turbo Ring or the Head of this Turbo Chain.
Blinking
This IKS switch has become Ring Master of this Turbo Ring after the Turbo Ring was broken, or Chain Head of this Turbo Chain after the Turbo Chain was broken..
MSTR/
HEAD
GREEN
Off
This IKS switch is neither the Master of this Turbo Ring nor the Head of this Turbo Chain.
On
When this IKS switch enables the coupling or tailing function to form a back-up path.
CPLR/
TAIL
GREEN
Off
When this IKS switch disables the coupling and tailing function.
Mode LEDs
On
The corresponding module port’s link is active.
Blinking
The corresponding module port’s data is being transmitted.
LNK/ACT GREEN
Off
The corresponding module port’s link is inactive.
Off
The corresponding module port’s data is being transmitted at 10 Mbps.
On
The corresponding module port’s data is being transmitted at 100 Mbps.
SPEED GREEN
Blinking
The corresponding module port’s data is being transmitted at 1000 Mbps.
On
The corresponding module port’s data is being transmitted in full duplex mode.
FDX/HDX GREEN
Off
The corresponding module port’s data is being transmitted in half duplex mode.
On
The corresponding module’s port is the ring port of this IKS switch.
RING PORT
GREEN
Off
The corresponding module’s port is not the ring port of this IKS switch.
On
The corresponding module’s port is the coupler port of this IKS switch.
COUPLER
PORT
GREEN
Off
The corresponding module’s port is not the coupler port of this IKS switch.
PoE Module LEDs
On The corresponding port is supplying po wer
PoE AMBER
Off
The corresponding port is not supplying power
Specifications
Technology
Standards IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x,
802.1D, 802.1W, 802.1Q, 802.1p, 802.1X,
802.3ad
Flow control IEEE 802.3x flow control, back pressure flow
control
Interface
Fast Ethernet Slot 1 for any combination of 4, 6, 7, or 8-port
PM-7200 fast Ethernet modules with 10/100BaseT(X) (TP/PoE/M12 interface), 100BaseFX (SC/ST connector), or 100BaseSFP
Gigabit Ethernet Slot 2 for 2-port PM-7200 Gigabit Ethernet combo
module with 10/100/1000BaseT(X), 1000Base
SFP slots (SFP slot, LC connector) System LED Indicators
STAT, PWR1, PWR2, FAULT, MSTR/HEAD,
CPLR/TAIL
Mode LED Indicators
LNK/ACT, FDX/HDX, SPEED, RING PORT,
COUPLER PORT PoE LED Indicators
PoE
Alarm Contact One relay output with current carrying capacity of
3A @ 30 VDC or 3A @ 240 VAC Optical Fiber (100BaseFX) Distance Multi-mode
0 to 5 km, 1300 nm (50/125μm, 800 MHz*km)
0 to 4 km, 1300 nm (62.5/125μm, 500 MHz*km)
Single-mode
0 to 40 km, 1310 nm (9/125μm, 3.5 PS/(nm*km)) Min. TX Output Multi-mode: -20 dBm; single-mode: -5 dbm Max. TX Output Multi-mode: -10 dBm; single-mode: 0 dbm RX Sensitivity Multi-mode: -32 dBm; single-mode: -34 dbm
Power
Input Voltage 48VDC (44 to 57V) Input Current Max. 3.3A @ 48VDC
Physical Characteristics
Housing IP 30 protection, metal case Dimensions (W x H x D)
440 x 44 x 325 mm (17.32 x 1.73 x 12.80 in.)
Weight IKS-6726-8PoE-F-48-T 4260 g
IKS-6726-8PoE-F-48-48-T 4460 g Installation 19” rack mounting
Regulatory Approvals
Safety EN60950-1 Road Traffic NEMA TS2 Rail Traffic EN50121-4 EMI FCC Part 15, CISPR (EN55022) class A Environmental Limits Operating Temp. -40 to 75°C (-40 to 167°F) Storage Temp. -40 to 85°C (-40 to 185°F) Ambient Relative Humidity.
5 to 95% (non-condensing)
Warranty Warranty Period 5 years Details See www.moxa.com/warranty
Note: A shielded cable is required for EN50121-4.
Click here for online support:
www.moxa.com/support
The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872)
Europe: +49-89-3 70 03 99-0
Asia-Pacific: +886-2-8919-1230
China: +86-21-5258-9955 (toll-free: 800-820-5036)
© 2010 Moxa Inc., all rights reserved.
Reproduction without permission is prohibited.
Loading...