— 4 — — 5 — — 6 —
FAULT: The relay contact of the 10-pin terminal block connector are
used to detect user-configured events. The two wires attached to the
RELAY contacts form an open circuit when a user-configured event is
triggered. If a user-configured event does not occur, the RELAY circuit
will be closed.
Wiring the Redundant Power Inputs
Each IKS switch has two
sets of power inputs:
power input 1 and power input 2.
STEP 1: Insert the dual set positive/negative DC wires into PWR1 and
PWR2 terminals (+ → pins 1, 9; - → pins 2, 10), or insert the L/N AC
wires into PWR1 and PWR2 terminals (L → pin 1, 9; N → pin 2,10)
STEP 2: To keep the DC or AC wires from pulling loose, use a
screwdriver to tighten the wire-clamp screws on the front of the terminal
block connector.
LED Indicators
The front panel of the IKS switch contains several LED indicators. The
function of each LED is described in the table below.
LED Color State Description
System LEDs
On
System has passed self-diagnosis test on
boot-up and is ready to run.
GREEN
Blinking
System is undergoing the self-diagnosis
test.
STAT
RED On System failed self-diagnosis on boot-up.
On
Power is being supplied to the main
module’s power input PWR1.
PWR1 AMBER
Off
Power is not being supplied to the main
module’s power input PWR1.
On
Power is being supplied to the main
module’s power input PWR2.
PWR2 AMBER
Off
Power is not being supplied to the main
module’s power input PWR2.
On
The corresponding PORT alarm is enabled
and a user-configured event has been
triggered.
FAULT RED
Off
The corresponding PORT alarm is enabled
and a user-configured event has not been
triggered, or the corresponding PORT
alarm is disabled.
On
This IKS switch is the Master of this Turbo
Ring or the Head of this Turbo Chain.
Blinking
This IKS switch has become Ring Master
of this Turbo Ring after the Turbo Ring
was broken, or Chain Head of this Turbo
Chain after the Turbo Chain was broken..
MSTR/
HEAD
GREEN
Off
This IKS switch is neither the Master of
this Turbo Ring nor the Head of this Turbo
Chain.
On
When this IKS switch enables the coupling
or tailing function to form a back-up path.
CPLR/
TAIL
GREEN
Off
When this IKS switch disables the
coupling and tailing function.
Mode LEDs
On
The corresponding module port’s link is
active.
Blinking
The corresponding module port’s data is
being transmitted.
LNK/ACT GREEN
Off
The corresponding module port’s link is
inactive.
Off
The corresponding module port’s data is
being transmitted at 10 Mbps.
On
The corresponding module port’s data is
being transmitted at 100 Mbps.
SPEED GREEN
Blinking
The corresponding module port’s data is
being transmitted at
1000 Mbps.
On
The corresponding module port’s data is
being transmitted in full duplex mode.
FDX/HDX GREEN
Off
The corresponding module port’s data is
being transmitted in half duplex mode.
On
The corresponding module’s port is the
ring port of this IKS switch.
RING
PORT
GREEN
Off
The corresponding module’s port is not the
ring port of this IKS switch.
On
The corresponding module’s port is the
coupler port of this IKS switch.
COUPLER
PORT
GREEN
Off
The corresponding module’s port is not the
coupler port of this IKS switch.
PoE Module LEDs
On The corresponding port is supplying po wer
PoE AMBER
Off
The corresponding port is not supplying
power
Specifications
Technology
Standards IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x,
802.1D, 802.1W, 802.1Q, 802.1p, 802.1X,
802.3ad
Flow control IEEE 802.3x flow control, back pressure flow
control
Interface
Fast Ethernet Slot 1 for any combination of 4, 6, 7, or 8-port
PM-7200 fast Ethernet modules with
10/100BaseT(X) (TP/PoE/M12
interface), 100BaseFX (SC/ST connector), or
100BaseSFP
Gigabit Ethernet Slot 2 for 2-port PM-7200 Gigabit Ethernet combo
module with 10/100/1000BaseT(X), 1000Base
SFP slots (SFP slot, LC connector)
System LED
Indicators
STAT, PWR1, PWR2, FAULT, MSTR/HEAD,
CPLR/TAIL
Mode LED
Indicators
LNK/ACT, FDX/HDX, SPEED, RING PORT,
COUPLER PORT
PoE LED
Indicators
PoE
Alarm Contact One relay output with current carrying capacity of
3A @ 30 VDC or 3A @ 240 VAC
Optical Fiber (100BaseFX)
Distance Multi-mode
0 to 5 km, 1300 nm (50/125μm, 800 MHz*km)
0 to 4 km, 1300 nm (62.5/125μm, 500 MHz*km)
Single-mode
0 to 40 km, 1310 nm (9/125μm, 3.5 PS/(nm*km))
Min. TX Output Multi-mode: -20 dBm; single-mode: -5 dbm
Max. TX Output Multi-mode: -10 dBm; single-mode: 0 dbm
RX Sensitivity Multi-mode: -32 dBm; single-mode: -34 dbm
Power
Input Voltage 48VDC (44 to 57V)
Input Current Max. 3.3A @ 48VDC
Physical Characteristics
Housing IP 30 protection, metal case
Dimensions
(W x H x D)
440 x 44 x 325 mm (17.32 x 1.73 x 12.80 in.)
Weight IKS-6726-8PoE-F-48-T 4260 g
IKS-6726-8PoE-F-48-48-T 4460 g
Installation 19” rack mounting
Regulatory Approvals
Safety EN60950-1
Road Traffic NEMA TS2
Rail Traffic EN50121-4
EMI FCC Part 15, CISPR (EN55022) class A
Environmental Limits
Operating Temp. -40 to 75°C (-40 to 167°F)
Storage Temp. -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity.
5 to 95% (non-condensing)
Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty
Note: A shielded cable is required for EN50121-4.
Click here for online support:
www.moxa.com/support
The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872)
Europe: +49-89-3 70 03 99-0
Asia-Pacific: +886-2-8919-1230
China: +86-21-5258-9955 (toll-free: 800-820-5036)
© 2010 Moxa Inc., all rights reserved.
Reproduction without permission is prohibited.